Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods

This European Standard specifies performance requirements and test methods for portable, transportable and fixed electrical apparatus for the measurement of the oxygen concentration in gas mixtures indicating up to 25 % (v/v). This European Standard applies to apparatus intended for commercial and industrial safety applications, including integral sampling systems of aspirated apparatus. In the case of inert gas purging, this European Standard applies also to apparatus with an oxygen measuring function for explosion protection. It does not apply to external sampling systems, nor laboratory, scientific or medical equipment nor those which are used exclusively for process control. NOTE: The most commonly used oxygen sensors in commercial equipment for industrial application are: paramagnetic sensors; electrochemical sensors (aqueous and solid electrolytes)

Elektrische Geräte für die Detektion und die Messung von Sauerstoff - Anforderungen an das Betriebsverhalten und Prüfmethoden

Appareils électriques de détection et de mesure d'oxygène - Règles de fonctionnement et méthodes d'essais

Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods

General Information

Status
Withdrawn
Publication Date
09-Jul-1998
Withdrawal Date
31-Dec-1998
Parallel Committee
IEC/SC 31L - IEC_SC_31L
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Feb-2005
Completion Date
01-Feb-2005

Relations

Effective Date
29-Jan-2023

Frequently Asked Questions

EN 50104:1998 is a standard published by CLC. Its full title is "Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods". This standard covers: This European Standard specifies performance requirements and test methods for portable, transportable and fixed electrical apparatus for the measurement of the oxygen concentration in gas mixtures indicating up to 25 % (v/v). This European Standard applies to apparatus intended for commercial and industrial safety applications, including integral sampling systems of aspirated apparatus. In the case of inert gas purging, this European Standard applies also to apparatus with an oxygen measuring function for explosion protection. It does not apply to external sampling systems, nor laboratory, scientific or medical equipment nor those which are used exclusively for process control. NOTE: The most commonly used oxygen sensors in commercial equipment for industrial application are: paramagnetic sensors; electrochemical sensors (aqueous and solid electrolytes)

This European Standard specifies performance requirements and test methods for portable, transportable and fixed electrical apparatus for the measurement of the oxygen concentration in gas mixtures indicating up to 25 % (v/v). This European Standard applies to apparatus intended for commercial and industrial safety applications, including integral sampling systems of aspirated apparatus. In the case of inert gas purging, this European Standard applies also to apparatus with an oxygen measuring function for explosion protection. It does not apply to external sampling systems, nor laboratory, scientific or medical equipment nor those which are used exclusively for process control. NOTE: The most commonly used oxygen sensors in commercial equipment for industrial application are: paramagnetic sensors; electrochemical sensors (aqueous and solid electrolytes)

EN 50104:1998 is classified under the following ICS (International Classification for Standards) categories: 19.080 - Electrical and electronic testing. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 50104:1998 has the following relationships with other standards: It is inter standard links to EN 50104:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 50104:1998 is associated with the following European legislation: EU Directives/Regulations: 94/9/EC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 50104:1998 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2000
Electrical apparatus for the detection and measurement of oxygen - Performance
requirements and test methods
Electrical apparatus for the detection and measurement of oxygen - Performance
requirements and test methods
Elektrische Geräte für die Detektion und die Messung von Sauerstoff - Anforderungen an
das Betriebsverhalten und Prüfmethoden
Appareils électriques de détection et de mesure d'oxygène - Règles de fonctionnement
et méthodes d'essais
Ta slovenski standard je istoveten z: EN 50104:1998
ICS:
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
29.260.20 (OHNWULþQLDSDUDWL]D Electrical apparatus for
HNVSOR]LYQDR]UDþMD explosive atmospheres
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...