EN 61000-4-3:2006/IS1:2009
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen hochfrequente elektromagnetische Felder
Compatibilité électromagnétique (CEM) - Partie 4-3: Techniques d'essai et de mesure - Essai d'immunité aux champs électromagnétiques rayonnés aux fréquences radioélectriques
Elektromagnetna združljivost (EMC) - 4-3. del: Preskusne in merilne tehnike - Preskušanje odpornosti proti sevanim radiofrekvenčnim elektromagnetnim poljem * Tolmačenje 5. točke standarda
General Information
- Status
- Withdrawn
- Publication Date
- 25-Feb-2009
- Withdrawal Date
- 25-Aug-2009
- Technical Committee
- CLC/TC 210 - Electromagnetic Compatibility (EMC)
- Drafting Committee
- IEC/SC 77B - IEC_SC_77B
- Parallel Committee
- IEC/SC 77B - IEC_SC_77B
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 13-Oct-2023
- Completion Date
- 13-Oct-2023
Relations
- Effective Date
- 03-Nov-2020
- Effective Date
- 29-Jan-2023
Frequently Asked Questions
EN 61000-4-3:2006/IS1:2009 is a addendum published by CLC. Its full title is "Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test". This standard covers: Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
EN 61000-4-3:2006/IS1:2009 is classified under the following ICS (International Classification for Standards) categories: 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 61000-4-3:2006/IS1:2009 has the following relationships with other standards: It is inter standard links to EN IEC 61000-4-3:2020, EN 61000-4-3:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 61000-4-3:2006/IS1:2009 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EC, 2004/108/EU, 2014/30/EU; Standardization Mandates: M/490. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 61000-4-3:2006/IS1:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2009
(OHNWURPDJQHWQD]GUXåOMLYRVW(0&GHO3UHVNXVQHLQPHULOQHWHKQLNH
3UHVNXãDQMHRGSRUQRVWLSURWLVHYDQLPUDGLRIUHNYHQþQLPHOHNWURPDJQHWQLPSROMHP
7ROPDþHQMHWRþNHVWDQGDUGD
Electromagnetic compatibility (EMC) -- Part 4-3: Testing and measurement techniques -
Radiated, radio-frequency, electromagnetic field immunity test * Interpretation of Clause
Ta slovenski standard je istoveten z: EN 61000-4-3:2006/IS1:2009
ICS:
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 61000-4-3/IS1
Interpretation Sheet 1
EN 61000-4-3:2006
English version
___________
Foreword
This Interpretation Sheet to the European Standard EN 61000-4-3:2006 was prepared by the
Interpretation Panel of the Technical Committee CENELEC TC 210, Electromagnetic compatibility (EMC).
The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC
on 2008-11-14.
Clause 5 Test levels
Table 1 – Test levels
Question:
How to apply the test field strengths ?
Interpretation:
The test field strengths are to be applied as stated in Ta
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.