EN 61169-24:2009
(Main)Radio-frequency connectors - Part 24: Sectional specification - Radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable networks (type F)
Radio-frequency connectors - Part 24: Sectional specification - Radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable networks (type F)
IEC 61169-24:2009(E), which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with screw coupling, typically for use in 75 ohm cable networks (type F). It describes the interface dimensions with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all DS relating to type F connectors. This second edition differs from the first edition in that all drawings have been reworked and improved to allow frequency extension up to 3 GHz.
Hochfrequenzsteckverbinder - Teil 24: Rahmenspezifikation - Koaxiale Hochfrequenzsteckverbinder mit Schraubkupplung, vorzugsweise für den Einsatz in 75 Ohm Kabelnetzen (Typ F)
Connecteurs pour fréquences radioélectriques - Partie 24: Spécification intermédiaire - Connecteurs coaxiaux pour fréquences radioélectriques avec couplage vissé, spécifiquement utilisés dans les réseaux câblés 75 ohms (série F)
La CEI 61169-24:2009 est une spécification intermédiaire (SS: Sectional Specification). Elle fournit des informations et des règles pour la préparation de spécifications particulières (DS: Detail Specification) pour les connecteurs coaxiaux pour fréquences radioélectriques avec couplage vissé, typiquement utilisés dans des réseaux de distribution par câbles de 75 Ω (type F). Elle décrit les dimensions d interface avec les informations sur les calibres et les essais obligatoires, sélectionnés dans la CEI 61169-1, applicables à toutes les spécifications particulières relatives aux connecteurs de type F. La présente spécification indique les caractéristiques de performance recommandées à prendre en considération pour rédiger une spécification particulière et elle porte sur des programmes d'essai et des exigences d'inspection.
Radiofrekvenčni konektorji - 24. del: Področna specifikacija - Radiofrekvenčni koaksialni konektorji z navojnim spajanjem, tipični za uporabo v 75-ohmskih kabelskih omrežjih (tip F) (IEC 61169-24:2009)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-2009
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD5DGLRIUHNYHQþQL
NRDNVLDOQLNRQHNWRUML]QDYRMQLPVSDMDQMHPWLSLþQL]DXSRUDERYRKPVNLK
NDEHOVNLKRPUHåMLKWLS),(&
Radio-frequency connectors - Part 24: Sectional specification - Radio frequency coaxial
connectors with screw coupling typically for use in 75 ohm cable networks (type F) (IEC
61169-24:2009)
Hochfrequenzsteckverbinder - Teil 24: Rahmenspezifikation – Koaxiale
Hochfrequenzsteckverbinder mit Schraubkupplung, vorzugsweise für den Einsatz in 75
Ohm Kabelnetzen (Typ F) (IEC 61169-24:2009)
Connecteurs pour fréquences radioélectriques - Partie 24: Spécification intermédiaire -
Connecteurs coaxiaux pour fréquences radioélectriques avec couplage vissé,
spécifiquement utilisés dans les réseaux câblés 75 ohms (série F) (CEI 61169-24:2009)
Ta slovenski standard je istoveten z: EN 61169-24:2009
ICS:
31.220.10 9WLþLLQYWLþQLFHNRQHNWRUML Plug-and-socket devices.
Connectors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 61169-24
NORME EUROPÉENNE
April 2009
EUROPÄISCHE NORM
ICS 31.220.10 Supersedes EN 61169-24:2001
English version
Radio-frequency connectors -
Part 24: Sectional specification -
Radio frequency coaxial connectors with screw coupling,
typically for use in 75 ohm cable networks (type F)
(IEC 61169-24:2009)
Connecteurs Hochfrequenzsteckverbinder -
pour fréquences radioélectriques - Teil 24: Rahmenspezifikation -
Partie 24: Spécification intermédiaire - Koaxiale Hochfrequenzsteckverbinder
Connecteurs coaxiaux pour fréquences mit Schraubkupplung, vorzugsweise
radioélectriques avec couplage vissé, für den Einsatz in 75 Ohm Kabelnetzen
spécifiquement utilisés dans les réseaux (Typ F)
câblés 75 ohms (série F) (IEC 61169-24:2009)
(CEI 61169-24:2009)
This European Standard was approved by CENELEC on 2009-03-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: avenue Marnix 17, B - 1000 Brussels
© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61169-24:2009 E
Foreword
The text of document 46F/108/FDIS, future edition 2 of IEC 61169-24, prepared by SC 46F, R.F. and
microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and
was approved by CENELEC as EN 61169-24 on 2009-03-01.
This European Standard supersedes EN 61169-24:2001.
to allow frequency extension up to 3 GHz.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2009-12-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2012-03-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61169-24:2009 was approved by CENELEC as a European
Standard without any modification.
__________
- 3 - EN 61169-24:2009
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
1) 2)
IEC 60068-2-52 - Environmental testing - EN 60068-2-52 1996
Part 2: Tests - Test Kb: Salt mist, cyclic
(sodium chloride solution)
IEC 61169-1 1992 Radio-frequency connectors - EN 61169-1 1994
A1 1996 Part 1: Generic specification - General A1 1996
A2 1997 requirements and measuring methods A2 1997
1)
Undated reference.
2)
Valid edition at date of issue.
IEC 61169-24 ®
Edition 2.0 2009-02
INTERNATIONAL
STANDARD
Radio-frequency connectors –
Part 24: Sectional specification – Radio frequency coaxial connectors with screw
coupling, typically for use in 75 Ω cable networks (type F)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
S
ICS 31.220.10 ISBN 2-8318-1031-2
– 2 – 61169-24 © IEC:2009(E)
CONTENTS
FOREWORD.4
1 Scope.6
2 Normative references .6
3 Interface dimensions .6
3.1 Dimensions .6
3.1.1 Connector “F” type female socket (indoor) physical dimensions.7
3.1.2 Connector “F” type male plug (indoor) physical dimensions .8
3.2 Mechanical gauges.9
3.2.1 Mating socket centre conductor acceptance diameter test .9
3.2.2 Mating port centre conductor acceptance electrical test.10
3.2.3 Reference plane electrical contact.10
4 Quality assessment procedures.10
4.1 General .10
4.2 Ratings and characteristics .10
4.3 Environmental characteristics for outdoor sockets (see Annex A) .12
4.4 Test schedule and inspection requirements .12
4.4.1 Acceptance tests .12
4.4.2 Periodic tests .13
4.5 Procedures.14
4.5.1 Quality conformance inspection .14
4.5.2 Qualification approval and its maintenance.14
5 Instructions for preparation of detail specifications .14
5.1 General .14
5.2 Identification of the detail specification .15
5.3 Identification of the component.15
5.4 Performance.15
5.5 Marking, ordering information and related matters .15
5.6 Selection of tests, test conditions and severities.15
5.7 Blank detail specification pro-forma for type F connector.16
Annex A (informative) Recommended outdoor “F” type socket / Plug physical
dimensions .21
Figure 1 – Connector “F” type female socket (indoor) (for dimensions, see Table 1) .7
Figure 2 – Connector “F” type male plug (indoor) (for dimensions, see Table 2).8
Figure 3 – Gauge for the centre socket conductor.9
Figure A.1 – Outdoor female “F” socket (for dimensions, see Table A.1).21
Figure A.2 – Outdoor “F” type male plug (for dimensions, see Table A.2).22
61169-24 © IEC:2009(E) – 3 –
Table 1 – Connector “F” type female socket (indoor).7
Table 2 – Connector “F” type male plug (indoor) .8
Table 3 – Test sequence for the centre socket conductor.9
Table 4 – Ratings and characteristics .10
Table 5 – Acceptance tests.12
Table 6 – Periodic tests .13
Table A.1 – Outdoor female “F” socket dimensions .21
Table A.2 – Outdoor “F” type male plug dimensions.22
– 4 – 61169-24 © IEC:2009(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________
RADIO-FREQUENCY CONNECTORS –
Part 24: Sectional specification –
Radio frequency coaxial connectors
with screw coupling, typically for use
in 75 Ω cable networks (type F)
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.