EN 60695-2-2:1994
(Main)Fire hazard testing - Part 2: Test methods - Section 2: Needle-flame test
Fire hazard testing - Part 2: Test methods - Section 2: Needle-flame test
Specifies a needle-flame test to stimulate the effect of small flames which may result from fault conditions within the equipment, in order to assess by a simulation technique the fire hazard. Has the status of a basic safet y publication in accordance with IEC Guide 104.
Prüfungen zur Beurteilung der Brandgefahr - Teil 2: Prüfverfahren - Hauptabschnitt 2: Prüfung mit der Nadelflamme
Essais relatifs aux risques du feu - Partie 2: Méthodes d'essai - Section 2: Essai au brûleur-aiguille
Prescrit un essai au brûleur-aiguille pour simuler l'effet de petites flammes qui peuvent provenir de défaillances à l'intérieur du matériel, afin d'évaluer de façon simulée le risque du feu. A le statut d'une publication fondamentale de sécurité conformément au Guide 104.
Fire hazard testing - Part 2: Test methods – Section 2: Needle-flame test (IEC 60695-2-2:1991)
General Information
- Status
- Withdrawn
- Publication Date
- 25-Jan-1994
- Withdrawal Date
- 25-Jul-1994
- Technical Committee
- CLC/SR 89 - Fire hazard testing
- Drafting Committee
- IEC/TC 89 - IEC_TC_89
- Parallel Committee
- IEC/TC 89 - IEC_TC_89
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Feb-2008
- Completion Date
- 01-Feb-2008
Relations
- Effective Date
- 29-Jan-2023
- Effective Date
- 29-Jan-2023
Frequently Asked Questions
EN 60695-2-2:1994 is a standard published by CLC. Its full title is "Fire hazard testing - Part 2: Test methods - Section 2: Needle-flame test". This standard covers: Specifies a needle-flame test to stimulate the effect of small flames which may result from fault conditions within the equipment, in order to assess by a simulation technique the fire hazard. Has the status of a basic safet y publication in accordance with IEC Guide 104.
Specifies a needle-flame test to stimulate the effect of small flames which may result from fault conditions within the equipment, in order to assess by a simulation technique the fire hazard. Has the status of a basic safet y publication in accordance with IEC Guide 104.
EN 60695-2-2:1994 has the following relationships with other standards: It is inter standard links to EN 60695-11-5:2005, EN 60695-2-2:1994/A1:1995. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 60695-2-2:1994 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 60695-2-2:1994 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Fire hazard testing - Part 2: Test methods – Section 2: Needle-flame test (IEC 60695-2-2:1991)Prüfungen zur Beurteilung der Brandgefahr -- Teil 2: Prüfverfahren -- Hauptabschnitt 2: Prüfung mit der NadelflammeEssais relatifs aux risques du feu -- Partie 2: Méthodes d'essai -- Section 2: Essai au brûleur-aiguilleFire hazard testing -- Part 2: Test methods -- Section 2: Needle-flame test29.020Elektrotehnika na splošnoElectrical engineering in general13.220.40Sposobnost vžiga in obnašanje materialov
...