Connectors for electrical and electronic equipment - Product requirements - Part 3-106: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface

IEC 61076-3-106:2023 constitutes a detail product specification for 8-way connectors for data transmission with frequencies up to 600 MHz. It covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in the IEC 60603-7 series to IP65/IP67 rating according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms according to this document and a variety of different mounting configurations and termination types which are detailed in the IEC 60603-7 series. Common mating configurations for all variants are defined in IEC 60603-7. The mating dimensions for the housings under Clause 3 allow the mating conditions under IEC 60603-7 to be fulfilled. The fully assembled variants (connectors) described in this document incorporate fully compliant IEC 60603-7 series fixed and free connectors.

Steckverbinder für elektrische und elektronische Einrichtungen – Produktanforderungen - Teil 3-106: Rechteckige Steckverbinder - Bauartspezifikation für Schutzgehäuse für die Anwendung mit 8-poligen geschirmten und ungeschirmten Steckverbindern für industrielle Umgebungen zur Aufnahme der Schnittstelle der Reihe IEC 60603-7

Connecteurs pour équipements électriques et électroniques - Exigences de produit - Partie 3-106: Connecteurs rectangulaires - Spécification particulière pour boîtiers de protection utilisés avec des connecteurs blindés et non blindés 8 voies pour des environnements industriels incorporant l’interface série IEC 60603-7

IEC 61076-3-106: 2023 constitue une spécification détaillée pour les connecteurs 8 voies pour la transmission de données avec des fréquences allant jusqu'à 600 MHz.It couvre les boîtiers de protection pour la mise à niveau des connecteurs blindés et non blindés à 8 voies existants utilisant l'interface décrite dans la série CEI 60603-7 à IP65/IP67 selon la CEI 60529, pour une utilisation dans des environnements industriels. Les boîtiers couvrent une variété de mécanismes de verrouillage différents selon le présent document et une variété de configurations de montage et de types de terminaison différents qui sont détaillés dans la série CEI 60603-7. Les configurations d'accouplement communes pour toutes les variantes sont définies dans la CEI 60603-7. Les dimensions d'accouplement des boîtiers en vertu de l'article 3 permettent de remplir les conditions d'accouplement de la norme CEI 60603-7. Les variantes (connecteurs) entièrement assemblées décrites dans le présent document intègrent des connecteurs fixes et libres entièrement conformes à la norme CEI 60603-7.

Konektorji za električno in elektronsko opremo - Zahteve za izdelek - 3-106. del: Pravokotni konektorji - Podrobna specifikacija za zaščitna ohišja za uporabo pri 8-rednih zaslonjenih in nezaslonjenih konektorjih za industrijska okolja z vgrajenimi zaporednimi vmesniki po IEC 60603-7 (IEC 61076-3-106:2023)

Ta del standarda IEC 61076 predstavlja podrobno specifikacijo za 8-redne konektorje za prenos podatkov s frekvencami do 600 MHz.
Zajema zaščitna ohišja za nadgradnjo obstoječih 8-rednih zaslonjenih in nezaslonjenih konektorjev, ki uporabljajo vmesnik, opisan v skupini standardov IEC 60603-7, na oceno IP65/IP67 v skladu s standardom IEC 60529 za uporabo v industrijskih okoljih.
Ohišja pokrivajo vrsto različnih zaklepnih mehanizmov v skladu s tem dokumentom in vrsto različnih konfiguracij vgradnje in tipov zaključkov, ki so podrobno opisani v skupini standardov IEC 60603-7.
Splošne konfiguracije spajanja za vse različice so opredeljene v standardu IEC 60603-7. Dimenzije spajanja za ohišja po točki 3 omogočajo izpolnitev pogojev spajanja po standardu IEC 60603-7.
V celoti sestavljene različice (konektorji), ki so opisane v tem dokumentu, vključujejo fiksne in proste konektorje, v celoti skladne s skupino standardov IEC 60603-7.

General Information

Status
Published
Publication Date
31-Aug-2023
Withdrawal Date
12-Jun-2022
Technical Committee
Drafting Committee
Current Stage
6060 - Document made available - Publishing
Start Date
01-Sep-2023
Completion Date
01-Sep-2023

Relations

Standard
EN IEC 61076-3-106:2023 - BARVE
English language
41 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2023
Konektorji za električno in elektronsko opremo - Zahteve za izdelek - 3-106. del:
Pravokotni konektorji - Podrobna specifikacija za zaščitna ohišja za uporabo pri 8-
rednih zaslonjenih in nezaslonjenih konektorjih za industrijska okolja z vgrajenimi
zaporednimi vmesniki po IEC 60603-7 (IEC 61076-3-106:2023)
Connectors for electrical and electronic equipment - Product requirements - Part 3-106:
Rectangular connectors - Detail specification for protective housings for use with 8-way
shielded and unshielded connectors for industrial environments incorporating the IEC
60603-7 series interface (IEC 61076-3-106:2023)
Steckverbinder für elektrische und elektronische Einrichtungen – Produktanforderungen
– Teil 3-106: Rechteckige Steckverbinder - Bauartspezifikation für Schutzgehäuse für die
Anwendung mit 8-poligen geschirmten und ungeschirmten Steckverbindern für
industrielle Umgebungen zur Aufnahme der Schnittstelle der Reihe IEC 60603-7 (IEC
61076-3-106:2023)
Connecteurs pour équipements électroniques - Exigences de produit - Partie 3-106:
Connecteurs rectangulaires - Spécification particulière pour boîtiers de protection utilisés
avec des connecteurs blindés et non blindés 8 voies pour des environnements
industriels incorporant l'interface série CEI 60603-7 (IEC 61076-3-106:2023)
Ta slovenski standard je istoveten z: EN IEC 61076-3-106:2023
ICS:
31.220.10 Vtiči in vtičnice, konektorji Plug-and-socket devices.
Connectors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 61076-3-106

NORME EUROPÉENNE
EUROPÄISCHE NORM September 2023
ICS 31.220.10 Supersedes EN 61076-3-106:2006
English Version
Connectors for electrical and electronic equipment - Product
requirements - Part 3-106: Rectangular connectors - Detail
specification for protective housings for use with 8-way shielded
and unshielded connectors for industrial environments
incorporating the IEC 60603-7 series interface
(IEC 61076-3-106:2023)
Connecteurs pour équipements électriques et électroniques Steckverbinder für elektrische und elektronische
- Exigences de produit - Partie 3-106: Connecteurs Einrichtungen - Produktanforderungen - Teil 3-106:
rectangulaires - Spécification particulière pour boîtiers de Rechteckige Steckverbinder - Bauartspezifikation für
protection utilisés avec des connecteurs blindés et non Schutzgehäuse für die Anwendung mit 8-poligen
blindés 8 voies pour des environnements industriels geschirmten und ungeschirmten Steckverbindern für
incorporant l'interface série IEC 60603-7 industrielle Umgebungen zur Aufnahme der Schnittstelle
(IEC 61076-3-106:2023) der Reihe IEC 60603-7
(IEC 61076-3-106:2023)
This European Standard was approved by CENELEC on 2023-08-23. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2023 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61076-3-106:2023 E

European foreword
The text of document 48B/3034/FDIS, future edition 2 of IEC 61076-3-106, prepared by SC 48B
"Electrical connectors" of IEC/TC 48 "Electrical connectors and mechanical structures for electrical
and electronic equipment" was submitted to the IEC-CENELEC parallel vote and approved by
CENELEC as EN IEC 61076-3-106:2023.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2024-05-23
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2026-08-23
document have to be withdrawn
This document supersedes EN 61076-3-106:2006 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 61076-3-106:2023 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standard indicated:
IEC 60512-99-001:2012 NOTE Approved as EN 60512-99-001:2012 (not modified)
IEC 60512-99-002:2022 NOTE Approved as EN IEC 60512-99-002:2022 (not modified)
IEC 61076-3-114 NOTE Approved as EN 61076-3-114
IEC 61076-3-115 NOTE Approved as EN 61076-3-115
IEC 61076-3-116 NOTE Approved as EN 61076-3-116
IEC 61076-3-117 NOTE Approved as EN 61076-3-117
ISO 14405 (series) NOTE Approved as EN ISO 14405 (series)
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the
relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cencenelec.eu.
Publication Year Title EN/HD Year
IEC 60068-1 - Environmental testing - Part 1: General EN 60068-1 -
and guidance
IEC 60068-2-14 - Environmental testing - Part 2-14: Tests - EN 60068-2-14 -
Test N: Change of temperature
IEC 60068-2-30 - Environmental testing - Part 2-30: Tests - EN 60068-2-30 -
Test Db: Damp heat, cyclic (12 h + 12 h
cycle)
IEC 60512-1-1 - Connectors for electronic equipment - EN 60512-1-1 -
Tests and measurements - Part 1-1:
General examination - Test 1a: Visual
examination
IEC 60512-1-2 - Connectors for electronic equipment - EN 60512-1-2 -
Tests and measurements - Part 1-2:
General examination - Test 1b:
Examination of dimension and mass
IEC 60512-2-1 2002 Connectors for electronic equipment - EN 60512-2-1 2002
Tests and measurements - Part 2-1:
Electrical continuity and contact resistance
tests - Test 2a: Contact resistance -
Millivolt level method
IEC 60512-2-5 - Connectors for electronic equipment - EN 60512-2-5 -
Tests and measurements - Part 2-5:
Electrical continuity and contact resistance
tests - Test 2e: Contact disturbance
IEC 60512-3-1 2002 Connectors for electronic equipment - EN 60512-3-1 2002
Tests and measurements - Part 3-1:
Insulation tests - Test 3a: Insulation
resistance
IEC 60512-4-1 2003 Connectors for electronic equipment - EN 60512-4-1 2003
Tests and measurements - Part 4-1:
Voltage stress tests - Test 4a: Voltage
proof
IEC 60512-6-3 - Connectors for electronic equipment - EN 60512-6-3 -
Tests and measurements - Part 6-3:
Dynamic stress tests - Test 6c: Shock
IEC 60512-6-4 - Connectors for electronic equipment - EN 60512-6-4 -
Tests and measurements - Part 6-4:
Dynamic stress tests - Test 6d: Vibration
(sinusoidal)
IEC 60512-8-1 2010 Connectors for electronic equipment - EN 60512-8-1 2010
Tests and measurements - Part 8-1: Static
load tests (fixed connectors) - Test 8a:
Static load, transverse
IEC 60512-9-1 2010 Connectors for electronic equipment - EN 60512-9-1 2010
Tests and measurements - Part 9-1:
Endurance tests - Test 9a: Mechanical
operation
IEC 60512-11-3 - Connectors for electronic equipment - EN 60512-11-3 -
Tests and measurements - Part 11-3:
Climatic tests - Test 11c: Damp heat,
steady state
IEC 60512-11-4 - Connectors for electronic equipment - EN 60512-11-4 -
Tests and measurements - Part 11-4:
Climatic tests - Test 11d: Rapid change of
temperature
IEC 60512-13-1 2006 Connectors for electronic equipment - EN 60512-13-1 2006
Tests and measurements - Part 13-1:
Mechanical operation tests - Test 13a:
Engaging and separating forces
- -  + corrigendum Dec. 2006
IEC 60512-13-5 - Connectors for electronic equipment - EN 60512-13-5 -
Tests and measurements - Part 13-5:
Mechanical operation tests - Test 13e:
Polarizing and keying method
IEC 60512-15-6 2008 Connectors for electronic equipment - EN 60512-15-6 2008
Tests and measurements - Part 15-6:
Connector tests (mechanical) - Test 15f:
Effectiveness of connector coupling
devices
IEC 60529 1989 Degrees of protection provided by EN 60529 1991
enclosures (IP Code)
- -  + corrigendum May 1993
IEC 60603-7 - Connectors for electronic equipment - Part EN IEC 60603-7 -
7: Detail specification for 8-way,
unshielded, free and fixed connectors
IEC 60603-7-1 - Connectors for electronic equipment - Part EN 60603-7-1 -
7-1: Detail specification for 8-way,
shielded, free and fixed connectors
IEC 60664-1 - Insulation coordination for equipment EN IEC 60664-1 -
within low-voltage supply systems - Part 1:
Principles, requirements and tests
IEC 61076-1 2006 Connectors for electronic equipment - EN 61076-1 2006
Product requirements - Part 1: Generic
specification
IEC 61156-2 - Multicore and symmetrical pair/quad - -
cables for digital communications - Part 2:
Symmetrical pair/quad cables with
transmission characteristics up to 100 MHz
- Horizontal floor wiring - Sectional
specification
IEC 61156-3 - Multicore and symmetrical pair/quad - -
cables for digital communications - Part 3:
Work area cable - Sectional specification
IEC 61156-4 - Multicore and symmetrical pair/quad - -
cables for digital communications - Part 4:
Riser cables - Sectional specification

IEC 61076-3-106 ®
Edition 2.0 2023-07
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Connectors for electrical and electronic equipment – Product requirements –

Part 3-106: Rectangular connectors – Detail specification for protective

housings for use with 8-way shielded and unshielded connectors for industrial

environments incorporating the IEC 60603-7 series interface

Connecteurs pour équipements électriques et électroniques – Exigences de

produit –
Partie 3-106: Connecteurs rectangulaires – Spécification particulière pour

boîtiers de protection utilisés avec des connecteurs blindés et non blindés

8 voies pour des environnements industriels incorporant l’interface série

IEC 60603-7
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 31.220.10  ISBN 978-2-8322-7023-3

– 2 – IEC 61076-3-106:2023 © IEC 2023
CONTENTS
FOREWORD . 5
INTRODUCTION . 7
1 Scope . 8
2 Normative references . 8
3 Terms and definitions . 10
4 Dimensional information . 10
4.1 Common features. 10
4.2 General . 10
4.3 Contact arrangement of all connector types . 10
4.4 IP65/IP67 sealing . 10
4.5 Industrial IEC 60603-7 variant 01 – bayonet coupling . 11
4.5.1 Industrial IEC 60603-7 variant 01, fixed connector . 11
4.5.2 Industrial IEC 60603-7 variant 01, free connector . 12
4.5.3 Mounting information for variant 01, fixed connector . 12
4.6 Industrial IEC 60603-7 variant 04 – snap-in coupling . 14
4.6.1 Industrial IEC 60603-7 variant 04, fixed connector . 14
4.6.2 Industrial IEC 60603-7 variant 04, free connector . 15
4.6.3 Mounting information for variant 04, fixed connector . 16
4.7 Industrial IEC 60603-7 variant 05 – locking lever coupling . 17
4.7.1 Industrial IEC 60603-7 variant 05, fixed connector . 17
4.7.2 Industrial IEC 60603-7 variant 05, free connector . 18
4.7.3 Mounting information for variant 05, fixed connector . 19
4.8 Industrial IEC 60603-7 variant 06 – snap-in coupling . 20
4.8.1 Industrial IEC 60603-7 variant 06, fixed connector . 20
4.8.2 Industrial IEC 60603-07 variant 06, free connector . 21
4.8.3 Mounting information for variant 06, fixed connector . 22
4.9 Industrial IEC 60603-7 variant 07 – locking lever coupling . 23
4.9.1 Industrial IEC 60603-7 variant 07, fixed connector side . 23
4.9.2 Industrial IEC 60603-7 variant 07, free connector . 24
4.9.3 Mounting information for variant 07, fixed connector . 25
4.10 Termination information . 25
5 Gauges – Connectors for the IEC 60603-7 interface . 25
6 Characteristics . 25
6.1 Climatic category . 25
6.2 Electrical . 26
6.2.1 Clearance and creepage distances . 26
6.2.2 Voltage proof . 26
6.2.3 Current-carrying capacity . 27
6.2.4 Mating cycles with power applied . 27
6.2.5 Initial contact resistance . 27
6.2.6 Input to output resistance . 28
6.2.7 Resistance unbalance. 28
6.2.8 Initial insulation resistance . 28
6.3 Transmission characteristics . 28
6.4 Mechanical . 28
6.4.1 Mechanical operation . 28

IEC 61076-3-106:2023 © IEC 2023 – 3 –
6.4.2 Effectiveness of connector coupling devices transversal . 28
6.4.3 Effectiveness of connector coupling devices . 28
6.4.4 Engaging and separating forces . 29
7 Test schedule . 29
7.1 General . 29
7.2 Test procedures and measuring methods . 29
7.3 Preconditioning . 29
7.4 Wiring and mounting of specimens . 29
7.4.1 Wiring . 29
7.4.2 Mounting . 30
7.5 Arrangement for contact resistance test . 30
7.6 Arrangement for dynamic stress tests . 30
7.7 Basic (minimum) test schedule. 30
7.8 Full test schedule . 30
7.8.1 General . 30
7.8.2 Test group P – Preliminary . 31
7.8.3 Test group AP – Dynamic/climatic . 32
7.8.4 Test Group BP – Mechanical . 34
7.8.5 Test group CP – Continuity . 35
7.8.6 Test Group DP . 35
7.8.7 Test Group EP . 35
Bibliography . 36

Figure 1 – Variant 01, fixed connector . 11
Figure 2 – Variant 01, free connector . 12
Figure 3 – Variant 01, style 1 mounting drawing . 13
Figure 4 – Variant 01, style 2 mounting drawing . 13
Figure 5 – Variant 04, fixed connector . 14
Figure 6 – Variant 04, free connector . 15
Figure 7 – Variant 04 mounting drawing . 16
Figure 8 – Variant 05, fixed connector . 17
Figure 9 – Variant 05, free connector . 18
Figure 10 – Variant 05 mounting drawing . 19
Figure 11 – Variant 06, fixed connector . 20
Figure 12 – Variant 06, free connector . 21
Figure 13 – Variant 06 mounting drawing . 22
Figure 14 – Variant 07, fixed connector . 23
Figure 15 – Variant 07, free connector . 24
Figure 16 – Variant 07 mounting drawing . 25
Figure 17 – Connector derating curve . 27
Figure 18 – Vibration and shock test arrangement . 30

Table 1 – Dimensions for fixed connector variant 01 . 11
Table 2 – Dimensions for free connector variant 01 . 12
Table 3 – Variant 01, style 1 mounting information . 13
Table 4 – Variant 01, style 2 mounting information . 13

– 4 – IEC 61076-3-106:2023 © IEC 2023
Table 5 – Dimensions for fixed connector variant 04 . 14
Table 6 – Dimensions for free connector variant 04 . 15
Table 7 – Variant 04 mounting information . 16
Table 8 – Dimensions for fixed connector variant 05 . 17
Table 9 – Dimensions for free connector variant 05 . 18
Table 10 – Variant 05 mounting information . 19
Table 11 – Dimensions for fixed connector variant 06 . 20
Table 12 – Dimensions for free connector variant 06 . 21
Table 13 – Variant 06 mounting information . 22
Table 14 – Dimensions fixed connector variant 07 . 23
Table 15 – Dimensions for free connector variant 07 . 24
Table 16 – Variant 07 mounting information . 25
Table 17 – Climatic categories – selected values for environmental performance
level A . 26
Table 18 – Creepage and clearance . 26
Table 19 – Test group P . 31
Table 20 – Test group AP – Dynamic/climatic . 32
Table 21 – Test Group BP – Mechanical . 34
Table 22 – Test group CP – Continuity . 35

IEC 61076-3-106:2023 © IEC 2023 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
CONNECTORS FOR ELECTRICAL AND ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 3-106: Rectangular connectors – Detail specification for protective
housings for use with 8-way shielded and unshielded connectors for
industrial environments incorporating the IEC 60603-7 series interface

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
rights. IEC shall not be held responsible for identifying any or all such patent rights.
IEC 61076-3-106 has been prepared by subcommittee 48B: Electrical connectors, of IEC
technical committee 48: Electrical connectors and mechanical structures for electrical and
electronic equipment. It is an International Standard.
This second edition cancels and replaces the first edition published in 2006. This edition
constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) improvement of drawings and addition of dimensions.

– 6 – IEC 61076-3-106:2023 © IEC 2023
The text of this International Standard is based on the following documents:
Draft Report on voting
48B/3034/FDIS 48B/3045/RVD
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
A list of all parts in the IEC 61076 series, published under the general title Connectors for
electrical and electronic equipment – Product requirements, can be found on the IEC website.
Future standards in this series will carry the new general title as cited above. Titles of existing
standards in this series will be updated at the time of the next edition.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The "colour inside" logo on the cover page of this document indicates
that it contains colours which are considered to be useful for the correct understanding
of its contents. Users should therefore print this document using a colour printer.

IEC 61076-3-106:2023 © IEC 2023 – 7 –
INTRODUCTION
This document, originally issued in 2006 and including 10 variants, describes now 5 variants of
connector housing with different geometries (rectangular or circular) and locking systems
(locking lever, snap-in, bayonet coupling) suitable for all the connector interfaces of the
IEC 60603-7 series, either shielded or unshielded.
The purpose of this set of variants, now reduced to reflect their market relevance, is to provide
several competing ways to upgrade the degree of protection of the resulting data transmission
connectors, to IP65/IP67, mainly in view of their use in industrial environments, while
maintaining all the original performance of the housed IEC 60603-7 compliant connectors,
which can be of different source than these 5 variants of connector housings.
Each variant may be available on the market by multiple sources and based on different
materials (i.e. either metallic or thermoplastic insulating, particularly for the main part of the
housing, but also regarding the locking means) to suit the needs of various industrial
applications.
Some of these variants have been endorsed by other IEC technical committees and/or by
external consortia as the reference interface for specific applications.
Being the basic interface of series IEC 60603-7 a rectangular one, this standard document was
originally issued as a Part 106 detail product specifications under the IEC 61076-3 sectional
specification covering rectangular connectors for electrical and electronic equipment, although
half of the original variants described in this document (variants 01, 03, 08, 09 and 10), currently
only variant 01 is included in this document – own a circular connector interface, all the variants
having nonetheless in common the purpose to upgrade the IP degree of protection to IP65/IP67,
and the incorporated IEC 60603-7 series connector interface.
NOTE It is worthwhile to inform users of this document that further variants 11 through 14 referring this document
were successively published from 2007 to 2009 as IEC 61076-3-114 trough IEC 61076-3-117. Among these variants,
for which reference should be made to the relevant publication (see Bibliography), variants 11 and 12 have circular
geometry, while variants 13 and 14 have square (rectangular geometry).

– 8 – IEC 61076-3-106:2023 © IEC 2023
CONNECTORS FOR ELECTRICAL AND ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 3-106: Rectangular connectors – Detail specification for protective
housings for use with 8-way shielded and unshielded connectors for
industrial environments incorporating the IEC 60603-7 series interface

1 Scope
This part of IEC 61076 constitutes a detail product specification for 8-way connectors for data
transmission with frequencies up to 600 MHz.
It covers protective housings for upgrading existing 8-way shielded and unshielded connectors
utilizing the interface described in the IEC 60603-7 series to IP65/IP67 rating according to
IEC 60529, for use in industrial environments.
The housings cover a variety of different locking mechanisms according to this document and
a variety of different mounting configurations and termination types which are detailed in the
IEC 60603-7 series.
Common mating configurations for all variants are defined in IEC 60603-7. The mating
dimensions for the housings under Clause 3 allow the mating conditions under IEC 60603-7 to
be fulfilled.
The fully assembled variants (connectors) described in this document incorporate fully
compliant IEC 60603-7 series fixed and free connectors.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60068-1, Environmental testing – Part 1: General and guidance
IEC 60068-2-14, Environmental testing – Part 2-14: Tests – Test N: Change of temperature
IEC 60068-2-30, Environmental testing – Part 2-30: Tests – Test Db: Damp heat, cyclic (12 h +
12 h cycle)
IEC 60512-1-1, Connectors for electronic equipment – Tests and measurements – Part 1-1:
General examination – Test 1a: Visual examination
IEC 60512-1-2, Connectors for electronic equipment – Tests and measurements – Part 1-2:
General examination – Test 1b: Examination of dimension and mass
IEC 60512-2-1:2002, Connectors for electronic equipment – Tests and measurements –
Part 2-1: Electrical continuity and contact resistance tests – Test 2a: Contact resistance –
Millivolt level method
IEC 61076-3-106:2023 © IEC 2023 – 9 –
IEC 60512-2-5, Connectors for electronic equipment – Tests and measurements – Part 2-5:
Electrical continuity and contact resistance tests – Test 2e: Contact disturbance
IEC 60512-3-1:2002, Connectors for electronic equipment – Tests and measurements –
Part 3-1: Insulation tests – Test 3a: Insulation resistance
IEC 60512-4-1:2003, Connectors for electronic equipment – Tests and measurements –
Part 4-1: Voltage stress tests – Test 4a: Voltage proof
IEC 60512-6-3, Connectors for electronic equipment – Tests and measurements – Part 6-3:
Dynamic stress tests – Test 6c: Shock
IEC 60512-6-4, Connectors for electronic equipment – Tests and measurements – Part 6-4:
Dynamic stress tests – Test 6d: Vibration (sinusoidal)
IEC 60512-8-1:2010, Connectors for electronic equipment – Tests and measurements –
Part 8-1: Static load tests (fixed connectors) – Test 8a: Static load, transverse
IEC 60512-9-1:2010, Connectors for electronic equipment – Tests and measurements –
Part 9-1: Endurance tests – Test 9a: Mechanical operation
IEC 60512-11-3, Connectors for electronic equipment – Tests and measurements – Part 11-3:
Climatic tests – Test 11c: Damp heat, steady state
IEC 60512-11-4, Connectors for electronic equipment – Tests and measurements – Part 11-4:
Climatic tests – Test 11d: Rapid change of temperature
IEC 60512-13-1:2006 Connectors for electronic equipment – Tests and measurements –
Part 13-1: Mechanical operation tests – Test 13a: Engaging and separating forces
IEC 60512-13-5, Connectors for electronic equipment – Tests and measurements – Part 13-5:
Mechanical operation tests – Test 13e: Polarizing and keying method
IEC 60512-15-6:2008, Connectors for electronic equipment – Tests and measurements –
Part 15-6: Connector tests (mechanical) – Test 15f: Effectiveness of connector coupling devices
IEC 60529:1989, Degrees of protection provided by enclosures (IP Code)
IEC 60603-7, Connectors for electronic equipment – Part 7: Detail specification for 8-way,
unshielded, free and fixed connectors
IEC 60603-7-1, Connectors for electronic equipment – Part 7-1: Detail specification for 8-way,
shielded, free and fixed connectors
IEC 60664-1, Insulation coordination for equipment within low-voltage supply systems – Part 1:
Principles, requirements and tests
IEC 61076-1:2006, Connectors for electronic equipment – Product requirements – Part 1:
Generic specification
IEC 61156-2, Multicore and symmetrical pair/quad cables for digital communications – Part 2:
Symmetrical pair/quad cables with transmission characteristics up to 100 MHz – Horizontal floor
wiring – Sectional specification
IEC 61156-3, Multicore and symmetrical pair/quad cables for digital communications – Part 3:
Work area cable – Sectional specification

– 10 – IEC 61076-3-106:2023 © IEC 2023
IEC 61156-4, Multicore and symmetrical pair/quad cables for digital communications – Part 4:
Riser cables – Sectional specification
3 Terms and definitions
No terms and definitions are listed in this document.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
4 Dimensional information
4.1 Common features
The industrial connectors described in this document are composed of IEC 60603-7 style fixed
and free connectors, either shielded or unshielded, housed in unique, industrial rated connector
hood (shell) or housing.
NOTE Usually, an adapter is also employed to fit the IEC 60603-7 fixed or free connector in the relevant connector
hood (shell) or housing.
The mating information and contact requirements of the IEC 60603-7 interface portion of these
industrial connectors shall be compliant with the appropriate clauses of the relevant part of the
IEC 60603-7 series.
The following requirements apply to the complete connector comprised of both the free and
fixed connectors in one of the described variant shells/outer housing.
4.2 General
Dimensions are given in millimeters, drawings are shown in first/third angle projection. The
shape of connectors may deviate from those shapes given in the following figures as long as
the specified dimensions are not influenced.
4.3 Contact arrangement of all connector types
Contact arrangements shall be in accordance with the relevant parts of IEC 60603-7.
4.4 IP65/IP67 sealing
Connectors meant to comply with IP ratings per IEC 60529 require sealing of the components
in order to meet the requirements detailed in the test schedules in 7.8.

IEC 61076-3-106:2023 © IEC 2023 – 11 –
4.5 Industrial IEC 60603-7 variant 01 – bayonet coupling
4.5.1 Industrial IEC 60603-7 variant 01, fixed connector
Figure 1 shows a fixed connector with female contacts and Table 1 shows the related
dimensions.
Figure 1 – Variant 01, fixed connector
Table 1 – Dimensions for fixed connector variant 01
Dimensions in millimetres
Letter Minimum Nominal Maximum
AA2 5,46 - -
AB2 2,74 3,15 3,56
AC2 11,78 11,91 12,03
AD2 1,40 1,52 1,65
AE2 6,68 6,90 7,11
AF2 3,88 4,01 4,14
AG2 1,35 1,47 1,57
AH2 17,3 17,45 17,6
AI2 24,46 24,55 24,64
AJ2 - - 10,69
AK2 13,33 13,46 13,58
AL2 8,25 8,38 8,50
AM2 2,75 2,95 3,15
AN2 0,152 0,229 0,304
AO2 7,62 - -
– 12 – IEC 61076-3-106:2023 © IEC 2023
4.5.2 Industrial IEC 60603-7 variant 01, free connector
Figure 2 shows a free connector with male contacts and Table 2 shows the related dimensions.

Figure 2 – Variant 01, free connector
Table 2 – Dimensions for free connector variant 01
Dimensions in millimetres
Letter Minimum Nominal Maximum
AO2 - - 5,08
AP2 7,85 7,98 8,1
AQ2 16,8 16,94 17,1
AR2 24,74 24,87 25,0
AS2 2,49 2,54 2,59
AT2 11,58 11,68 11,78
AU2 1,75 2,01 2,25
AX2 1,04 1,17 1,30
AY2 3,89 4,01 4,14
AZ2 6,35 6,48 6,60
BA2 10,19 - -
AV2 239° - 241°
AW2 119° - 121°
NOTE AT2 centred on AQ2.
4.5.3 Mounting information for variant 01, fixed connector
4.5.3.1 General
There are two types of mounting dimensions for variant 01.

IEC 61076-3-106:2023 © IEC 2023 – 13 –
4.5.3.2 Mounting style 1 for variant 01
Figure 3 shows the mounting and Table 3 shows the related dimensions.

Figure 3 – Variant 01, style 1 mounting drawing
Table 3 – Variant 01, style 1 mounting information
Dimensions in millimetres
Letter Minimum Nominal Maximum
AA3 12,34 12,56 12,77
AB3 26,92 27,41 27,89
AC3 2,49 2,55 2,69
4.5.3.3 Mounting style 2 for variant 01
Figure 4 shows the mounting and Table 4 shows the related dimensions.

Figure 4 – Variant 01, style 2 mounting drawing
Table 4 – Variant 01, style 2 mounting information
Dimensions in millimetres
Letter Minimum Nominal Maximum
AC4 - 30,55 -
AD4 - 32,26 -
AE4 - 4,37 -
– 14 – IEC 61076-3-106:2023 © IEC 2023
4.6 Industrial IEC 60603-7 variant 04 – snap-in coupling
4.6.1 Industrial IEC 60603-7 variant 04, fixed connector
Figure 5 shows a fixed connector with female contacts and Table 5 shows the related
dimensions.
Figure 5 – Variant 04, fixed connector
Tab
...