EN 61010-2-032:1995
(Main)Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test
Applies to hand-held and hand-manipulated CURRENT CLAMPS. These CURRENT CLAMPS are for use in the measurement of current without interruption of the current path of the circuit in which it is measured. They may be stand-alone CURRENT CLAMPS which are themselves within the scope of part 1, or accessories to other equipment within the scope of part 1. This standard does not apply to current transformers or current transducers intended for fixed installations.
Sicherheitsbestimmungen für elektrische Meß-, Steuer-, Regel- und Laborgeräte - Teil 2-032: Besondere Anforderungen an handgehaltene Strom-Meßzangen zum elektrischen Messen und Prüfen
Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 2-032: Prescriptions particulières pour pinces ampèremétriques tenues à la main pour mesurage et essais électriques
S'applique aux PINCES AMPEREMETRIQUES tenues ou manipulées à la main. Ces PINCES AMPEREMETRIQUES sont destinées au mesurage du courant dans le circuit mesuré sans interruption de ce circuit. Il peut s'agir de PINCES AMPEREMETRIQUES simples entrant dans le domaine d'application de la partie 1, ou d'accessoires à d'autres appareils électriques entrant dans le domaine d'application de la partie 1. Cette norme ne s'applique pas aux transformateurs de courant ni aux transducteurs de courant prévus pour des installations fixes.
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test
General Information
- Status
- Withdrawn
- Publication Date
- 09-Jan-1995
- Technical Committee
- CLC/SR 66 - Safety of measuring, control, and laboratory equipment
- Drafting Committee
- IEC/TC 66 - IEC_TC_66
- Parallel Committee
- IEC/TC 66 - IEC_TC_66
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Nov-2005
- Completion Date
- 01-Nov-2005
Relations
- Effective Date
- 29-Jan-2023
- Effective Date
- 03-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard
IMP NDT d.o.o.
Non-destructive testing services. Radiography, ultrasonic, magnetic particle, penetrant, visual inspection.
Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Q Techna d.o.o.
NDT and quality assurance specialist. 30+ years experience. NDT personnel certification per ISO 9712, nuclear and thermal power plant inspections, QA/
Sponsored listings
Frequently Asked Questions
EN 61010-2-032:1995 is a standard published by CLC. Its full title is "Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test". This standard covers: Applies to hand-held and hand-manipulated CURRENT CLAMPS. These CURRENT CLAMPS are for use in the measurement of current without interruption of the current path of the circuit in which it is measured. They may be stand-alone CURRENT CLAMPS which are themselves within the scope of part 1, or accessories to other equipment within the scope of part 1. This standard does not apply to current transformers or current transducers intended for fixed installations.
Applies to hand-held and hand-manipulated CURRENT CLAMPS. These CURRENT CLAMPS are for use in the measurement of current without interruption of the current path of the circuit in which it is measured. They may be stand-alone CURRENT CLAMPS which are themselves within the scope of part 1, or accessories to other equipment within the scope of part 1. This standard does not apply to current transformers or current transducers intended for fixed installations.
EN 61010-2-032:1995 is classified under the following ICS (International Classification for Standards) categories: 19.080 - Electrical and electronic testing. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 61010-2-032:1995 has the following relationships with other standards: It is inter standard links to EN 61010-2-032:2002, EN 61557-9:1999. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 61010-2-032:1995 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 61010-2-032:1995 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-avgust-1995
Safety requirements for electrical equipment for measurement, control and
laboratory use - Part 2-032: Particular requirements for hand-held current clamps
for electrical measurement and test
Safety requirements for electrical equipment for measurement, control, and laboratory
use -- Part 2-032: Particular requirements for hand-held current clamps for electrical
measurement and test
Sicherheitsbestimmungen für elektrische Meß-, Steuer-, Regel- und Laborgeräte -- Teil 2
-032: Besondere Anforderungen an handgehaltene Strom-Meßzangen zum elektrischen
Messen und Prüfen
Règles de sécurité pour appareils électriques de mesurage, de régulation et de
laboratoire -- Partie 2-032: Prescriptions particulières pour pinces ampèremétriques
tenues à la main pour mesurage et essais électriques
Ta slovenski standard je istoveten z: EN 61010-2-032:1995
ICS:
19.080 (OHNWULþQRLQHOHNWURQVNR Electrical and electronic
SUHVNXãDQMH testing
71.040.10 Kemijski laboratoriji. Chemical laboratories.
Laboratorijska oprema Laboratory equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...