Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Amandma A2:2011 je dodatek k standardu SIST EN 61000-4-3:2006.
This part of IEC 61000 is applicable to the immunity requirements of electrical and electronic equipment to radiated electromagnetic energy. It establishes test levels and the required test procedures. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to radiated, radio-frequency electromagnetic fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. NOTE 1 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products. This part deals with immunity tests related to the protection against RF electromagnetic fields from any source. Particular considerations are devoted to the protection against radio-frequency emissions from digital radiotelephones and other RF emitting devices. NOTE 2 Test methods are defined in this part for evaluating the effect that electromagnetic radiation has on the equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for quantitative determination of effects. The test methods defined are structured for the primary objective of establishing adequate repeatability of results at various test facilities for qualitative analysis of effects. This standard is an independent test method. Other test methods may not be used as substitutes for claiming compliance with this standard.

Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen hochfrequente elektromagnetische Felder

Compatibilité électromagnétique (CEM) - Partie 4-3: Techniques d'essai et de mesure - Essai d'immunité aux champs électromagnétiques rayonnés aux fréquences radioélectriques

Elektromagnetna združljivost (EMC) - 4-3. del: Preskusne in merilne tehnike - Preskušanje odpornosti proti sevanim radiofrekvenčnim elektromagnetnim poljem - Dodatek A2 (IEC 61000-4-3:2006/A2:2010)

Amandma A2:2011 je dodatek k standardu SIST EN 61000-4-3:2006.
Ta del IEC 61000 velja za zahteve za odpornost električne in elektronske opreme proti sevani elektromagnetni energiji. Vzpostavlja preskusne ravni in potrebne preskusne postopke. Namen tega standarda je vzpostaviti splošno referenco za vrednotenje odpornosti električne in elektronske opreme, ko nanjo delujejo sevana radiofrekvenčna elektromagnetna polja. Preskusna metoda, dokumentirana v tem delu IEC 61000, opisuje dosledno metodo za ocenjevanje odpornosti opreme ali sistema proti opredeljenemu pojavu. OPOMBA 1: Kot je opisano v Vodilu IEC 107, je to osnovna objava EMC, ki jo uporabljajo odbori za proizvode IEC. Kot je prav tako navedeno v Vodilu 107, so odbori IEC za proizvode odgovorni za ugotavljanje, ali naj se preskusi odpornosti uporabijo ali ne, in če se, so odgovorni za določevanje ustreznih preskusnih ravni in izvedbenih meril. TC 77 in njegovi pododbori so pripravljeni sodelovati z odbori za proizvode pri ocenjevanju vrednosti posameznih preskusov odpornosti za proizvode. Ta del obravnava preskuse odpornosti, povezane z zaščito proti RF-elektromagnetnim poljem iz katerega koli vira. Posebna pozornost je namenjena zaščiti pred radiofrekvenčnimi emisijami iz digitalnih radiotelefonov in drugih naprav, ki oddajajo radiofrekvenčno sevanje. OPOMBA 2: Preskusne metode v tem delu standarda so opredeljene za vrednotenje učinka elektromagnetnega sevanja na zadevno opremo. Simulacija in merjenje elektromagnetnega sevanja nista dovolj natančna za kvantitativno določevanje učinkov. Opredeljene preskusne metode so strukturirane za primarni cilj ugotavljanja zadostne ponovljivosti rezultatov v različnih preskuševalnih ustanovah za kvalitativno analizo učinkov. Ta standard je neodvisna preskusna metoda. Druge preskusne metode se ne smejo uporabiti kot nadomestki v skladu s tem standardom.

General Information

Status
Withdrawn
Publication Date
08-Jul-2010
Withdrawal Date
30-Jun-2013
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
13-Oct-2023
Completion Date
13-Oct-2023

Relations

Buy Standard

Amendment
EN 61000-4-3:2006/A2:2011
English language
8 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-maj-2011
(OHNWURPDJQHWQD]GUXåOMLYRVW (0& GHO3UHVNXVQHLQPHULOQHWHKQLNH
3UHVNXãDQMHRGSRUQRVWLSURWLVHYDQLPUDGLRIUHNYHQþQLPHOHNWURPDJQHWQLPSROMHP
'RGDWHN$ ,(&$
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques -
Radiated, radio-frequency, electromagnetic field immunity test
Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung
der Störfestigkeit gegen hochfrequente elektromagnetische Felder
Compatibilité électromagnétique (CEM) - Partie 4-3: Techniques d'essai et de mesure -
Essai d'immunité aux champs électromagnétiques rayonnés aux fréquences
radioélectriques
Ta slovenski standard je istoveten z: EN 61000-4-3:2006/A2:2010
ICS:
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 61000-4-3/A2
NORME EUROPÉENNE
July 2010
EUROPÄISCHE NORM
ICS 33.100.20
English version
Electromagnetic compatibility (EMC) -
Part 4-3: Testing and measurement techniques -
Radiated, radio-frequency, electromagnetic field immunity test
(IEC 61000-4-3:2006/A2:2010)
Compatibilité électromagnétique (CEM) - Elektromagnetische Verträglichkeit
Partie 4-3: Techniques d'essai (EMV) -
et de mesure - Teil 4-3: Prüf- und Messverfahren -
Essai d'immunité aux champs Prüfung der Störfestigkeit
électromagnétiques rayonnés gegen hochfrequente elektromagnetische
aux fréquences radioélectriques Felder
(CEI 61000-4-3:2006/A2:2010) (IEC 61000-4-3:2006/A2:2010)

This amendment A2 modifies the European Standard EN 61000-4-3:2006; it was approved by CENELEC on
2010-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61000-4-3:2006/A2:2010 E

Foreword
The text of document 77B/626/FDIS, future amendment 2 to IEC 61000-4-3:2006, prepared by SC 77B,
High frequency phenomena, of IEC TC 77, Electromagnetic compatibility, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as amendment A2 to EN 61000-4-3:2006
on 2010-07-01.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the amendment has to be
implemented at national level by publication of
an identical national standard or by endorsement (dop) 2011-04-01
– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2013-07-01
__________
Endorsement notice
The text of amendment 2:2010 to the International Standard IEC 61000-4-3:2006 was approved by
CENELEC as an amendment to the European Standard without any modification.
__________
IEC 61000-4-3 ®
Edition 3.0 2010-03
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
BASIC EMC PUBLICATION
PUBLICATION FONDAMENTALE EN CEM
AMENDMENT 2
AMENDEMENT 2
Electromagnetic compatibility (EMC) –
Part 4-3: Testing and measurement techniques – Radiated, radio-frequency,
electromagnetic field immunity test

Compatibilité électromagnétique (CEM) –
Partie 4-3: Techniques d'essai et de mesure – Essai d'immunité aux champs
électromagnétiques rayonnés aux fréquences radioélectriques

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
F
CODE PRIX
ICS 33.100.20 ISBN 978-2-88910-373-7
– 2 – 61000-4-3 Amend. 2 © IEC:2010
FOREWORD
This amendment has been prepared by subcommittee 77B: High frequency phenomena, of
IEC technical committee 77: Electromagnetic compatibility.
The text of this amendment is based on the following documents:
FDIS Report on voting
77B/626/FDIS 77B/629/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the stability date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________
CONTENTS
Add the title of Annex J as follows:
Annex J (informative) Measurement uncertainty due to test instrumentation

Add, after Annex I, the following new Annex J:

61000-4-3 Amend. 2 © IEC:2010 – 3 –
Annex J
(informative)
Measurement uncertainty due to test instrumentation

J.1 General
This annex gives information related to measurement uncertainty (MU) of the test level setting
according to the particular needs of the test method contained in the main body of the
standard. Further information can be found in [1, 2] .
This annex shows an example of how an uncertainty budget can be prepared based upon
level setting. Other parameters of the disturbance quantity such as modulation frequency and
modulation depth, harmonics produced by the amplifier may also need to be considered in an
appropriate way by the test laboratory. The methodology shown in this annex is considered to
be applicable to all parameters of the disturbance quantity.
The uncertainty contribution for field homogeneity including test site effects is under
consideration.
J.2 Uncertainty budgets for level setting
J.2.1 Definition of the measurand
The measurand is the hypothetical test electric field strength (without an EUT) at the point of
the UFA selected according to the process of 6.2.1 step a) and 6.2.2 step a) of this standard.
J.2.2 MU contributors of the measura
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.