Electromagnetic compatibility - Basic immunity standard - Surge immunity test

This standard EN 61000-4 relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environmental and installation conditions. These requirements are developed for and applicable to electrical and electronic equipment. The object of this section of standard EN 61000-4 is to establish a common reference for evaluating the performance of equipment when subjected to high energy disturbances on the power and interconnection lines. The standard defines: - range of test levels; - test equipment; - test set-up; - test procedure. The task of the described laboratory test is to find the reaction of the EUT under specified operational conditions caused by surge voltages from switching and lightning effects at certain threat-levels. It is not intended to test the capability of the insulation to withstand high voltage stress. Direct lightning is not considered in this standard.

Elektromagnetische Verträglichkeit - Störfestigkeits-Grundnorm - Störfestigkeit gegen Stoßspannungen

Compatibilité électromagnétique - Publication fondamentale d'immunité - Prescriptions relatives à l'immunité aux ondes de choc

Electromagnetic compatibility - Basic immunity standard - Surge immunity test

General Information

Status
Withdrawn
Publication Date
20-Oct-1994
Withdrawal Date
21-Mar-1995
Drafting Committee
IEC/SC 77B - IEC_SC_77B
Parallel Committee
IEC/SC 77B - IEC_SC_77B
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
22-Mar-1995
Completion Date
22-Mar-1995

Relations

Effective Date
09-Feb-2026
Standardization document

ENV 50142:1997

English language
38 pages
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

Intertek Testing Services NA Inc.

Intertek certification services in North America.

ANAB United States Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Sponsored listings

Frequently Asked Questions

ENV 50142:1994 is a standardization document published by CLC. Its full title is "Electromagnetic compatibility - Basic immunity standard - Surge immunity test". This standard covers: This standard EN 61000-4 relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environmental and installation conditions. These requirements are developed for and applicable to electrical and electronic equipment. The object of this section of standard EN 61000-4 is to establish a common reference for evaluating the performance of equipment when subjected to high energy disturbances on the power and interconnection lines. The standard defines: - range of test levels; - test equipment; - test set-up; - test procedure. The task of the described laboratory test is to find the reaction of the EUT under specified operational conditions caused by surge voltages from switching and lightning effects at certain threat-levels. It is not intended to test the capability of the insulation to withstand high voltage stress. Direct lightning is not considered in this standard.

This standard EN 61000-4 relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environmental and installation conditions. These requirements are developed for and applicable to electrical and electronic equipment. The object of this section of standard EN 61000-4 is to establish a common reference for evaluating the performance of equipment when subjected to high energy disturbances on the power and interconnection lines. The standard defines: - range of test levels; - test equipment; - test set-up; - test procedure. The task of the described laboratory test is to find the reaction of the EUT under specified operational conditions caused by surge voltages from switching and lightning effects at certain threat-levels. It is not intended to test the capability of the insulation to withstand high voltage stress. Direct lightning is not considered in this standard.

ENV 50142:1994 is classified under the following ICS (International Classification for Standards) categories: 29.020 - Electrical engineering in general. The ICS classification helps identify the subject area and facilitates finding related standards.

ENV 50142:1994 has the following relationships with other standards: It is inter standard links to EN 1776:1998. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ENV 50142:1994 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-marec-1997
Electromagnetic compatibility - Basic immunity standard - Surge immunity test
Electromagnetic compatibility - Basic immunity standard - Surge immunity test
Elektromagnetische Verträglichkeit - Störfestigkeits-Grundnorm - Störfestigkeit gegen
Stoßspannungen
Compatibilité électromagnétique - Publication fondamentale d'immunité - Prescriptions
relatives à l'immunité aux ondes de choc
Ta slovenski standard je istoveten z: ENV 50142:1994
ICS:
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

SIST ENV 5
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.