EN 61008-1:2004/IS1:2007
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's) - Part 1: General rules
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's) - Part 1: General rules
TC 23E advice: ISH to be published unchanged * Superseded by EN 61008-1:2012
Fehlerstrom-/Differenzstrom-Schutzschalter ohne eingebauten Überstromschutz (RCCBs) für Hausinstallationen und für ähnliche Anwendungen - Teil 1: Allgemeine Anforderungen
Interrupteurs automatiques à courant différentiel résiduel pour usages domestiques et analogues sans dispositif de protection contre les surintensités incorporées (ID) - Partie 1: Règles générales
Odklopniki na preostali (diferenčni) tok brez vgrajene nadtokovne zaščite za gospodinjstva in podobne namene (RCCB's) - 1. del: Splošna pravila
Ta mednarodni standard se uporablja za odklopnike na preostali (residualni) tok, ki so funkcionalno neodvisni ali odvisni od linijske napetosti, za gospodinjsko in podobno rabo, brez vgrajene nadtokovne zaščite (v nadaljnjem besedilu: RCCB), za nazivne napetosti do vključno 440 V izmenične napetosti, pri čemer nazivna frekvenca dosega 50 Hz, 60 Hz ali 50/60 Hz in nazivni tok ne presega 125 A in ki so namenjeni predvsem zaščiti pred električnim udarom. Te naprave so namenjene zaščiti oseb pred posrednim stikom, pri čemer so izpostavljeni prevodni deli inštalacije povezani z ustreznim ozemljilom. Uporabljajo se lahko za zaščito pred požarom zaradi stalnega ozemljitvenega okvarnega toka brez naprave za nadtokovno zaščito. Tudi odklopniki na preostali (residualni) tok (RCCB) z nazivnim preostalim obratovalnim tokom do vključno 30 mA se uporabljajo kot dodatna zaščita v primeru odpovedi zaščitnega sredstva pred električnim udarom. Ta standard se uporablja za naprave, ki hkrati izvajajo funkcije zaznavanja preostalega (residualnega) toka, primerjanja vrednosti tega toka s preostalo obratovalno vrednostjo in odprtja zaščitenega tokokroga, kadar preostali tok preseže to vrednost. Odklopniki RCCB so namenjeni uporabi v okolju s stopnjo onesnaženja 2. Primerni so za izolacijo. Odklopniki RCCB, ki so skladni s tem standardom, razen odklopnikov z neprekinjeno nevtralno točko, so primerni za uporabo v sistemih IT. Posebni zaščitni ukrepi (npr. prenapetostni odvodniki) so lahko potrebni, kadar lahko na strani dobave nastane prekomerna prenapetost (na primer v primeru dobave prek nadzemnih vodov) (glejte standard 60364-4-44). Odklopniki RCCB splošnega tipa se ne morejo po nesreči odklopiti, tudi kadar previsoka napetost (zaradi prehodnih preklapljanj ali udara strele) povzroči obremenilne tokove v inštalaciji brez nastanka preboja. Odporniki RCCB tipa S naj bi v zadostni meri ščitili pred neželenim odklopom, celo kadar previsoka napetost povzroči preboj in nastane nadaljnji tok. Posebne zahteve so potrebne za: – odklopnike na preostali (residualni) tok z vgrajeno nadtokovno zaščito (glejte standard IEC 61009-1); – odklopnike RCCB, vgrajene v vtiče ali namenjene le uporabi z vtiči in vtičnicami ali s spojkami naprav za gospodinjsko ali podobno splošno rabo; – odpornike RCCB, namenjene uporabi pri frekvencah, ki niso 50 Hz ali 60 Hz. Zahteve tega standarda se uporabljajo za običajne okoljske pogoje (glejte točko 7.1). Dodatne zahteve so lahko potrebne za odklopnike RCCB, ki se uporabljajo na lokacijah z neugodnimi okoljskimi pogoji. Ta standard ne zajema odklopnikov RCCB z akumulatorji.
General Information
- Status
- Withdrawn
- Publication Date
- 09-Aug-2007
- Withdrawal Date
- 10-Feb-2008
- Technical Committee
- CLC/TC 23E - Circuit breakers and similar devices for household and similar applications
- Drafting Committee
- IEC/SC 23E - IEC_SC_23E
- Parallel Committee
- IEC/SC 23E - IEC_SC_23E
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 18-Jun-2017
- Completion Date
- 18-Jun-2017
Relations
- Effective Date
- 29-Jan-2023
- Effective Date
- 29-Jan-2023
Get Certified
Connect with accredited certification bodies for this standard

UL Solutions
Global safety science company with testing, inspection and certification.
CEPREI Certification Center (Guangzhou Saibao)
Pioneer of third-party certification, subsidiary of Electronic Fifth Research Institute.
CESI Beijing Certification (Saisi)
Subsidiary of China Electronics Standardization Institute (CESI), established 1963.
Sponsored listings
Frequently Asked Questions
EN 61008-1:2004/IS1:2007 is a addendum published by CLC. Its full title is "Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's) - Part 1: General rules". This standard covers: TC 23E advice: ISH to be published unchanged * Superseded by EN 61008-1:2012
TC 23E advice: ISH to be published unchanged * Superseded by EN 61008-1:2012
EN 61008-1:2004/IS1:2007 is classified under the following ICS (International Classification for Standards) categories: 29.120.50 - Fuses and other overcurrent protection devices. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 61008-1:2004/IS1:2007 has the following relationships with other standards: It is inter standard links to EN 61008-1:2012, EN 61008-1:2004. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 61008-1:2004/IS1:2007 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2008
2GNORSQLNLQDSUHRVWDOLGLIHUHQþQLWRNEUH]YJUDMHQHQDGWRNRYQH]DãþLWH]D
JRVSRGLQMVWYDLQSRGREQHQDPHQH5&&%
VGHO6SORãQDSUDYLOD
Residual current operated circuit-breakers without integral overcurrent protection for
household and similar uses (RCCB's) - Part 1: General rules
Fehlerstrom-/Differenzstrom-Schutzschalter ohne eingebauten Überstromschutz
(RCCBs) für Hausinstallationen und für ähnliche Anwendungen - Teil 1: Allgemeine
Anforderungen
Interrupteurs automatiques a courant différentiel résiduel pour usages domestiques et
analogues sans dispositif de protection contre les surintensités incorporées (ID) - Partie
1: Regles générales
Ta slovenski standard je istoveten z: EN 61008-1:2004/IS1:2007
ICS:
29.120.50 9DURYDONHLQGUXJD Fuses and other overcurrent
PHGWRNRYQD]DãþLWD protection devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 61008-1/IS1
Interpretation Sheet 1
EN 61008-1:2004
English version
___________
Foreword
This Interpretation Sheet to the European Standard EN 61008-1:2004 was prepared by the Interpretation
Panel of the Technical Committee CENELEC TC 23E, Circuit breakers and similar devices for household
an
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...