Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization

Applies to electrically powered laboratory atomic spectrometers with thermal atomization, including atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively coupled plasma spectrometers, microwave coupled plasma spectrometers, and mass spectrometers, all with thermal atomization and ionization (including tubing and connectors which are provided by the manufacturer for connection to external supplies). This publication has the status of a group safety publication in accordance with IEC Guide 104.

Sicherheitsbestimmungen für elektrische Meß-, Steuer-, Regel- und Laborgeräte - Teil 2-061: Besondere Anforderungen an Labor-Atomspektrometer mit thermischer Atomisierung und Ionisation

Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 2-061: Prescriptions particulières pour spectromètres de laboratoire avec vaporisation et ionisation thermique

S'applique aux spectromètres de laboratoire équipés d'une alimentation électrique et d'une vaporisation thermique, y compris les spectromètres à absorption atomique, les photomètres de flamme, les spectromètres à fluorescence atomique, les spectromètres à plasma couplé par induction, les spectromètres à plasma couplé par micro-onde, les spectromètres de masse, tous avec vaporisation et ionisation thermiques, y compris les tuyaux et connecteurs des équipements qui sont fournis par le constructeur pour connexion aux alimentations externes. A le statut d'une publication groupée de sécurité conformément au Guide 104.

Safety requirements for electrical equipment for measurement, control, and laboratory use -- Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization (IEC 61010-2-061:1995)

General Information

Status
Withdrawn
Publication Date
09-Jan-1996
Drafting Committee
IEC/TC 66 - IEC_TC_66
Parallel Committee
IEC/TC 66 - IEC_TC_66
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Oct-2006
Completion Date
01-Oct-2006

Relations

Effective Date
29-Jan-2023

Get Certified

Connect with accredited certification bodies for this standard

IMP NDT d.o.o.

Non-destructive testing services. Radiography, ultrasonic, magnetic particle, penetrant, visual inspection.

SA Slovenia Verified

Inštitut za kovinske materiale in tehnologije

Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.

SA Slovenia Verified

Q Techna d.o.o.

NDT and quality assurance specialist. 30+ years experience. NDT personnel certification per ISO 9712, nuclear and thermal power plant inspections, QA/

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

EN 61010-2-061:1996 is a standard published by CLC. Its full title is "Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization". This standard covers: Applies to electrically powered laboratory atomic spectrometers with thermal atomization, including atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively coupled plasma spectrometers, microwave coupled plasma spectrometers, and mass spectrometers, all with thermal atomization and ionization (including tubing and connectors which are provided by the manufacturer for connection to external supplies). This publication has the status of a group safety publication in accordance with IEC Guide 104.

Applies to electrically powered laboratory atomic spectrometers with thermal atomization, including atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively coupled plasma spectrometers, microwave coupled plasma spectrometers, and mass spectrometers, all with thermal atomization and ionization (including tubing and connectors which are provided by the manufacturer for connection to external supplies). This publication has the status of a group safety publication in accordance with IEC Guide 104.

EN 61010-2-061:1996 is classified under the following ICS (International Classification for Standards) categories: 19.080 - Electrical and electronic testing. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 61010-2-061:1996 has the following relationships with other standards: It is inter standard links to EN 61010-2-061:2003. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 61010-2-061:1996 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 61010-2-061:1996 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...