EN 15254-3:2019
(Main)Extended application of results from fire resistance tests - Non-loadbearing walls - Part 3: Lightweight partitions
Extended application of results from fire resistance tests - Non-loadbearing walls - Part 3: Lightweight partitions
This document provides guidance and, where appropriate, defines procedures for variations of certain parameters and factors associated with the design of lightweight partitions, which have been tested in accordance with EN 1364-1, and classified according to EN 13501-2.
This document only applies to non-loadbearing lightweight partitions with a single steel framework, provided with a lining on both sides of the steel framework. The lightweight partition can be insulated with a mineral wool insulation within the partition cavity or not be insulated.
This document does not apply to any other types of non-loadbearing lightweight partitions considered in EN 1364-1.
Erweiterter Anwendungsbereich der Ergebnisse von Feuerwiderstandsprüfungen - Nichttragende Wände - Teil 3: Leichte Trennwände
Dieses Dokument enthält eine Anleitung für Änderungen bestimmter Parameter und Faktoren, die die Gestaltung von nach EN 1364-1 geprüften und nach EN 13501-2 klassifizierten leichten Trennwänden betreffen. Weiterhin definiert dieses Dokument, sofern zutreffend, die entsprechenden Verfahren.
Dieses Dokument gilt nur für nichttragende leichte Trennwände mit einem Einfachständerwerk aus Stahl, das auf beiden Seiten des Stahlständerwerks mit einer Beplankung versehen ist. Der Hohlraum der leichten Trennwand kann über eine Wärmedämmung aus Mineralwolle verfügen.
Dieses Dokument gilt nicht für jegliche anderen, in EN 1364-1 behandelten Arten von nichttragenden leichten Trennwänden.
Extension du champ d’application des résultats des essais de résistance au feu - Éléments non-porteurs - Partie 3 : Cloisons légères
Le présent document fournit des recommandations et, le cas échéant, définit des procédures pour les variations de certains paramètres et facteurs liés à la conception de cloisons légères qui ont été soumises à essai conformément à l’EN 1364‐1, et classées conformément à l’EN 13501‐2.
Le présent document s’applique uniquement aux cloisons légères avec une ossature en acier unique et munies d’un parement des deux côtés de l’ossature en acier. L’intérieur de la cavité de la cloison légère peut être isolé ou non avec de la laine minérale.
Le présent document ne s’applique pas aux autres types de cloisons légères traités dans l’EN 1364‐1.
Razširjena uporaba rezultatov preskusov požarne odpornosti - Nenosilne stene - 3. del: Lahke predelne stene
Ta dokument podaja smernice in, kjer je to primerno, določa postopke za spremembe nekaterih parametrov in dejavnikov, povezanih z načrtovanjem lahkih predelnih sten, ki so bile preskušene v skladu s standardom EN 1364-1 in razvrščene v skladu s standardom EN 13501-2.
Ta dokument se uporablja samo za nenosilne lahke predelne stene z enim jeklenim okvirjem, ki ima na obeh straneh oblogo. Lahka predelna stena je lahko izolirana z mineralno volno ali ne.
Ta dokument se ne uporablja za nobene druge vrste nenosilnih sten, ki so obravnavane v standardu EN 1364-1.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-oktober-2019
Razširjena uporaba rezultatov preskusov požarne odpornosti - Nenosilne stene -
3. del: Lahke predelne stene
Extended application of results from fire resistance tests - Non-loadbearing walls - Part
3: Lightweight partitions
Erweiterter Anwendungsbereich der Ergebnisse von Feuerwiderstandsprüfungen -
Nichttragende Wände - Teil 3: Leichte Trennwände
Extension du champ d'application des résultats des essais de résistance au feu -
Éléments non-porteurs - Partie 3 : Cloisons légères
Ta slovenski standard je istoveten z: EN 15254-3:2019
ICS:
13.220.50 Požarna odpornost Fire-resistance of building
gradbenih materialov in materials and elements
elementov
91.060.10 Stene. Predelne stene. Walls. Partitions. Facades
Fasade
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 15254-3
EUROPEAN STANDARD
NORME EUROPÉENNE
August 2019
EUROPÄISCHE NORM
ICS 13.220.50; 91.060.10
English Version
Extended application of results from fire resistance tests -
Non-loadbearing walls - Part 3: Lightweight partitions
Extension du champ d'application des résultats des Erweiterter Anwendungsbereich der Ergebnisse von
essais de résistance au feu - Éléments non-porteurs - Feuerwiderstandsprüfungen - Nichttragende Wände -
Partie 3 : Cloisons légères Teil 3: Leichte Trennwände
This European Standard was approved by CEN on 7 July 2019.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 15254-3:2019 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Principles . 6
4.1 General principles . 6
4.2 Use of test evidence . 7
5 General rules . 7
5.1 Fire performance classification . 7
5.2 Combination of modifications . 7
5.3 Reference test . 7
6 Specific changes to the components of the lightweight partition . 8
6.1 Lining . 8
6.2 Metal framework . 8
6.3 Mineral wool insulation . 9
6.4 Lightweight partition (system) . 10
Bibliography . 12
European foreword
This document (EN 15254-3:2019) has been prepared by Technical Committee CEN/TC 127
“Fire safety in buildings”, the secretariat of which is held by BSI.
This European Standard shall be given the status of a national standard, either by publication of
an identical text or by endorsement, at the latest by February 2020, and conflicting national
standards shall be withdrawn at the latest by February 2020.
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights. CEN shall not be held responsible for identifying any or all such patent
rights.
This document has been prepared under a mandate given to CEN by the European Commission
and the European Free Trade Association.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of
the following countries are bound to implement this European Standard: Austria, Belgium,
Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain,
Sweden, Switzerland, Turkey and the United Kingdom.
1 Scope
This document provides guidance and, where appropriate, defines procedures for variations of
certain parameters and factors associated with the design of lightweight partitions, which have
been tested in accordance with EN 1364-1, and classified according to EN 13501-2.
This document only applies to non-loadbearing lightweight partitions with a single steel
framework, provided with a lining on both sides of the steel framework. The lightweight
partition can be insulated with a mineral wool insulation within the partition cavity or not be
insulated.
This document does not apply to any other types of non-loadbearing lightweight partitions
considered in EN 1364-1.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their
content constitutes requirements of this document. For dated references, only the edition cited
applies. For undated references, the latest edition of the referenced document (including any
amendments) applies.
EN 14195, Metal framing components for gypsum board systems — Definitions, requirements and
test methods
EN 13162, Thermal insulating products for buildings — Factory made mineral wool (MW)
products — Specification
EN 15725, Extended application reports on the fire performance of construction products and
building elements
EN 1363-1, Fire resistance tests — Part 1: General Requirements
EN 1363-2, Fire resistance tests — Part 2: Alternative and additional procedures
EN 1364-1, Fire resistance tests for non-loadbearing elements — Part 1: Walls
EN 13501-1, Fire classification of construction products and building elements — Part 1:
Classification using data from reaction to fire tests
EN 13501-2, Fire classification of construction products and building elements — Part 2:
Classification using data from fire resistance tests, excluding ventilation services
3 Terms and definitions
For the purposes of this document the terms and definitions given in EN 1363-1, EN 1363-2,
EN 1364-1, EN 15725 and EN 13501-2, together with the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
— IEC Electropedia: available at http://www.electropedia.org/
— ISO Online browsing platform: available at http://www.iso.org/obp
3.1
lightweight partition
non-loadbearing wall that comprises a single steel framework, provided with a lining on both
sides of the steel framework
Note 1 to entry: The lightweight partition cavity can be insulated with a mineral wool insulation within
the partition cavity or not be insulated.
3.2
fire performance classification
classification of the lightweight partition in accordance with EN 13501-2 with only taking into
account the E and/or EI-classification
3.3
lining
layer(s) of boards fixed at each side to the steel framework of the lightweight partition
3.4
board
product with an A1 or A2 classification according to EN 13501-1 of rectangular shape and cross-
section in which the thickness is uniform and substantially smaller than the other dimensions,
and where the product is covered by a Technical Specification as defined in the CPR
3.5
mineral wool insulation
mineral wool as specified in EN 13162
3.6
metal framework
framework comprising steel profiles as specified in EN 14195
3.7
single steel framework
steel framework comprising only one row of steel studs
3.8
reference test
fire resistance test in accordance with EN 1363-1 (or EN 1363-2 when applicable) and
EN 1364-1, providing primary evidence, on which the extended application is to be based
3.9
additional test evidence
fire resistance test in accordance with EN 1363-1 (or EN 1363-2 when applicable) and
EN 1364-1, providing secondary evidence, on which the extended application is supported
3.10
overrun time
time of fire resistance in minutes beyond the fire performance classification time achieved in
the test
3.11
shape of the profiles of the metal framework
type of profile designated by the prefix-letter (e.g. C- or U-shaped)
4 Principles
4.1 General principles
Extended application is the outcome of a process (involving the application of defined rules that
may incorporate calculation procedures) that predicts, for a variation of a product property
and/or its intended end use application(s), a test result on the basis of one or more test results
to the same standard.
The extended application of the lightweight partition shall be based on the reference fire test
results performed according to EN 1364-1. Extended application reports shall be prepared
according to EN 15725.
When performing extended applications for a tested partition changes can occur either in
materials and/or in the construction. Both are dealt with in this standard. Table 1 gives an
overview of the changes which may be made in accordance with this extended application
standard.
Table 1 — Modifications and rules for lightweight partition walls
Modification Rule see clauses
Linings
Exchange of linings 6.1.1
Increase/decrease of the number of layers of boards 6.1.2
Increase/decrease of the dimensions of the boards 6.1.3
Change in board orientation 6.1.4
Change of position of layers of the boards 6.1.5
Metal framework
Change in shape of the steel profiles 6.2.2
Increase/decrease of the nominal thickness of the steel profiles 6.2.3
Increase/decrease of the nominal steel profiles depth (web) 6.2.4
Increase/decrease of the nominal steel profiles width (flange) 6.2.5
Increase/decrease of the stud spacing 6.2.6
Mineral wool insulation
Addition of mineral wool 6.3.2
Removal of mineral wool 6.3.3
Exchange of mineral wool 6.3.4
Increase/decrease of the tested density of the mineral wool 6.3.5
Increase/decrease of the thickness of the mineral wool 6.3.6
Lightweight partition (system)
Increase of height of the lightweight partition 6.4.1
Increase of width of the lightweight partition 6.4.2
4.2 Use of test evidence
4.2.1 General
The applicant for the extended application shall either be the “owner” (i.e. sponsor) of the
reference test and additional test evidence being submitted for the extension, or have written
permission from the owner to use the submitted test evidence.
4.2.2 Use of additional test evidence
Additional test evidence may be used to support extended application, for instance to evaluate
the influence of a particular component.
5 General rules
5.1 Fire performance classification
In the extended application, an increase in the classification time (e.g. from 30 min to 45 min)
shall not be permitted.
5.2 Combination of modifications
A combination of modifications mentioned in Table 1 is allowed.
5.3 Reference test
5.3.1 General
The basis for any extension is the reference test.
In case of an extended application described in Clause 6, the reference test shall have an
overrun time and/or a deflection less than the maximum allowed deflection if mentioned in the
relevant clause.
5.3.2 Overrun time
For some extended applications an overrun time is required. The required overrun time
depends on the intended classification time as shown in Table 2 below.
Table 2 — Required overrun time
Classification time Overrun time required
min
≤ 30 ≥ 3 min
> 30 and ≤ 60 ≥ 6 min
> 60 ≥ 10 % of the classification time
5.3.3 Maximum deflection
The maximum deflection of the lightweight partition is not in excess of h/30 with h being the
height of the tested lightweight partition.
6 Specific changes to the components of the lightweight parti
...
Questions, Comments and Discussion