EN ISO 11357-6:2013
(Main)Plastics - Differential scanning calorimetry (DSC) - Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) (ISO 11357-6:2008)
Plastics - Differential scanning calorimetry (DSC) - Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) (ISO 11357-6:2008)
ISO 11357-6:2008 specifies methods for the determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) of polymeric materials by means of differential scanning calorimetry (DSC). It is applicable to polyolefin resins that are in a fully stabilized or compounded form, either as raw materials or finished products. It may be applicable to other plastics.
Kunststoffe - Dynamische Differenz-Thermoanalyse (DSC) - Teil 6: Bestimmung der Oxidations-Induktionszeit (isothermische OIT) und Oxidations-Induktionstemperatur (dynamische OIT) (ISO 11357-6:2008)
Dieser Teil von ISO 11357 legt Verfahren für die Bestimmung der Oxidations-Induktionszeit (isothermische OIT) und Oxidations-Induktionstemperatur (dynamische OIT) von polymeren Werkstoffen mittels Dynamischer Differenz-Thermoanalyse (DSC) (Dynamischer Differenzkalorimetrie) fest. Er ist anwendbar auf Polyolefinharze, die in einer vollständig stabilisierten oder compoundierten Form entweder als Rohmaterialien oder als Fertigerzeugnisse vorliegen. Er darf auf andere Kunststoffe angewendet werden.
Plastiques - Analyse calorimétrique différentielle (DSC) - Partie 6: Détermination du temps d'induction à l'oxydation (OIT isotherme) et de la température d'induction à l'oxydation (OIT dynamique) (ISO 11357-6:2008)
L'ISO 11357-6:2008 spécifie des méthodes de détermination du temps d'induction à l'oxydation (OIT isotherme) et de la température d'induction à l'oxydation (OIT dynamique) des matériaux polymères au moyen de l'analyse calorimétrique différentielle (DSC). Elle s'applique aux résines polyoléfines sous forme totalement stabilisée ou sous forme de composition, soit comme matières premières, soit comme produits finis. Elle peut s'appliquer à d'autres plastiques.
Umetne mase - Diferenčna dinamična kalorimetrija (DSC) - 6. del: Ugotavljanje časa indukcijske oksidacije (izotermični OIT) in temperature indukcijske oksidacije (izodinamični OIT) (ISO 11357-6:2008)
Ta del standarda ISO 11357 navaja metode za ugotavljanje časa indukcijske oksidacije (izotermični OIT) in temperature indukcijske oksidacije (izodinamični OIT) polimernih materialov z diferenčno dinamično kalorimetrijo (DSC). Uporablja se za poliolefinske smole, ki so v popolnoma stabilni ali sestavljeni obliki, v obliki surovin ali končnih izdelkov. Lahko se uporablja za druge umetne mase.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-2013
8PHWQHPDVH'LIHUHQþQDGLQDPLþQDNDORULPHWULMD'6&GHO8JRWDYOMDQMH
þDVDLQGXNFLMVNHRNVLGDFLMHL]RWHUPLþQL2,7LQWHPSHUDWXUHLQGXNFLMVNHRNVLGDFLMH
L]RGLQDPLþQL2,7,62
Plastics - Differential scanning calorimetry (DSC) - Part 6: Determination of oxidation
induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) (ISO
11357-6:2008)
Kunststoffe - Dynamische Differenz-Thermoanalyse (DSC) - Teil 6: Oxidations-
Induktionszeit (isothermische OIT) oder - Temperatur (isodynamische OIT) (ISO 11357-
6:2008)
Plastiques - Analyse calorimétrique différentielle (DSC) - Partie 6: Détermination du
temps d'induction à l'oxydation (OIT isotherme) et de la température d'induction à
l'oxydation (OIT dynamique) (ISO 11357-6:2008)
Ta slovenski standard je istoveten z: EN ISO 11357-6:2013
ICS:
17.200.10 Toplota. Kalorimetrija Heat. Calorimetry
83.080.01 Polimerni materiali na Plastics in general
splošno
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN ISO 11357-6
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2013
ICS 83.080.01
English Version
Plastics - Differential scanning calorimetry (DSC) - Part 6:
Determination of oxidation induction time (isothermal OIT) and
oxidation induction temperature (dynamic OIT) (ISO 11357-
6:2008)
Plastiques - Analyse calorimétrique différentielle (DSC) - Kunststoffe - Dynamische Differenz-Thermoanalyse (DSC)
Partie 6: Détermination du temps d'induction à l'oxydation - Teil 6: Oxidations-Induktionszeit (isothermische OIT) oder
(OIT isotherme) et de la température d'induction à - Temperatur (isodynamische OIT) (ISO 11357-6:2008)
l'oxydation (OIT dynamique) (ISO 11357-6:2008)
This European Standard was approved by CEN on 22 December 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2013 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 11357-6:2013: E
worldwide for CEN national Members.
Contents Page
Foreword .3
Foreword
The text of ISO 11357-6:2008 has been prepared by Technical Committee ISO/TC 61 “Plastics” of the
International Organization for Standardization (ISO) and has been taken over as EN ISO 11357-6:2013 by
Technical Committee CEN/TC 249 “Plastics” the secretariat of which is held by NBN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by July 2013, and conflicting national standards shall be withdrawn at the
latest by July 2013.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Endorsement notice
The text of ISO 11357-6:2008 has been approved by CEN as a EN ISO 11357-6:2013 without any
modification.
INTERNATIONAL ISO
STANDARD 11357-6
Second edition
2008-06-15
Corrected version
2008-11-15
Plastics — Differential scanning
calorimetry (DSC) —
Part 6:
Determination of oxidation induction time
(isothermal OIT) and oxidation induction
temperature (dynamic OIT)
Plastiques — Analyse calorimétrique différentielle (DSC) —
Partie 6: Détermination du temps d'induction à l'oxydation
(OIT isotherme) et de la température d'induction à l'oxydation
(OIT dynamique)
Reference number
ISO 11357-6:2008(E)
©
ISO 2008
ISO 11357-6:2008(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2008
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2008 – All rights reserved
ISO 11357-6:2008(E)
Contents Page
Foreword. iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions. 2
4 Principle. 2
5 Apparatus and materials. 3
6 Test specimens . 4
7 Test conditions and specimen conditioning . 5
8 Calibration . 5
9 Procedure . 5
10 Expression of results . 8
11 Precision and bias . 10
12 Test report . 10
Bibliography . 12
ISO 11357-6:2008(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11357-6 was prepared by Technical Committee ISO/TC 61, Plastics, Subcommittee SC 5, Physical-
chemical properties.
This second edition cancels and replaces the first edition (ISO 11357-6:2002), which has been technically
revised. The most important changes in the revision are the following:
⎯ a dynamic OIT method, i.e. the measurement of oxidation induction temperature, has been included;
⎯ it is now possible to perform measurements in air as well as in oxygen;
⎯ the range of specimen sizes has been narrowed and specimen size has been redefined in terms of
thickness instead of mass;
⎯ the possibility of making single-point routine measurements with reduced accuracy has been included.
It also cancels and replaces ISO/TR 10837:1991.
ISO 11357 consists of the following parts, under the general title Plastics — Differential scanning calorimetry
(DSC):
⎯ Part 1: General principles
⎯ Part 2: Determination of glass transition temperature
⎯ Part 3: Determination of temperature and enthalpy of melting and crystallization
⎯ Part 4: Determination of specific heat capacity
⎯ Part 5: Determination of characteristic reaction-curve temperatures and times, enthalpy of reaction and
degree of conversion
⎯ Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature
(dynamic OIT)
⎯ Part 7: Determination of crystallization kinetics
In this corrected version, the sixth paragraph in the Foreword has been modified to reflect the fact that the
second edition replaces not only the first edition but also ISO/TR 10837:1991, Determination of the thermal
stability of polyethylene (PE) for use in gas pipes and fittings.
iv © ISO 2008 – All rights reserved
ISO 11357-6:2008(E)
Introduction
It should be noted that the measurement of oxidation induction time or temperature described in this part of
ISO 11357 provides a tool to assess the conformity of the material tested to a given formulation of plastics
compounds, but it is not intended to provide the concentration of antioxidant. Different antioxidants may have
different oxidation induction times or temperatures. Due to interaction of the antioxidant with other substances
in the formulation, different oxidation induction times or temperatures may result even with products having
the same type and concentration of antioxidant.
INTERNATIONAL STANDARD ISO 11357-6:2008(E)
Plastics — Differential scanning calorimetry (DSC) —
Part 6:
Determination of oxidation induction time (isothermal OIT) and
oxidation induction temperature (dynamic OIT)
SAFETY STATEMENT — Persons using this document should be familiar with normal laboratory
practice, if applicable. This document does not purport to address all of the safety concerns, if any,
associated with its use. It is the responsibility of the user to establish appropriate safety and health
practices and to ensure compliance with any regulatory requirements.
1 Scope
This part of ISO 11357 specifies methods for the determination of oxidation induction time (isothermal OIT)
and oxidation induction temperature (dynamic OIT) of polymeric materials by means of differential scanning
calorimetry (DSC). It is appl
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.