EN 15254-7:2012
(Main)Extended application of results from fire resistance tests - Non-loadbearing ceilings - Part 7: Metal sandwich panel construction
Extended application of results from fire resistance tests - Non-loadbearing ceilings - Part 7: Metal sandwich panel construction
This European Standard defines rules for extended applications, provides guidance, and, where appropriate, specifies procedures, for variations of certain parameters and factors associated with the design of internal non-load-bearing ceilings constructed of metal sandwich panels that have been tested in accordance with EN 1364-2.
This European Standard applies to self-supporting, double skin metal faced sandwich panels which have an insulating core bonded to both facings.
Erweiterter Anwendungsbereich der Ergebnisse von Feuerwiderstandsprüfungen - Nichttragende Unterdecken - Teil 7: Sandwichelemente in Metallbauweise
Diese Europäische Norm definiert Regeln für erweiterte Anwendungsbereiche, enthält Leitlinien, und legt, falls erforderlich, Verfahren zur Änderung von bestimmten Parametern und Faktoren fest, die mit der Bauweise von nichttragenden Innendecken aus Sandwichelementen in Metallbauweise, die nach EN 1364 2 geprüft wurden, zusammenhängen.
Diese Europäische Norm gilt für selbsttragende Sandwichelemente mit beidseitigen Metalldeckschichten und einem Kern aus Wärmedämmstoff, der auf beiden Seiten verklebt ist.
Application étendue des résultats d´essais de résistance au feu - Plafonds non porteurs - Partie 7: Panneaux sandwiches métalliques pour la construction
La présente Norme européenne définit des règles pour des applications étendues, fournit des lignes
directrices et, le cas échéant, définit des modes opératoires, pour les variations de certains paramètres et
facteurs associés à la conception de plafonds intérieurs non porteurs constitués de panneaux sandwich
métalliques et soumis à essai conformément à l'EN 1364-2.
La présente Norme européenne s'applique aux panneaux sandwich autoportants double peau à parements
métalliques ayant une âme isolante collées aux deux parements.
Razširjena uporaba rezultatov preskusov požarne odpornosti - Nenosilne stene - 7. del: Stene iz kovinskih sendvič panelov
Ta evropski standard določa pravila za razširjeno uporabo, zagotavlja navodila in po potrebi določa postopke za odstopanja nekaterih parametrov in faktorjev, povezanih z obliko notranjih nenosilnih sten, zgrajenih iz kovinskih sendvič panelov, preskušenih v skladu s standardom EN 1364-2. Ta evropski standard velja za samonosilne dvoslojne kovinske sendvič panele z izoliranim jedrom, vezanim na obe strani.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Erweiterter Anwendungsbereich der Ergebnisse von Feuerwiderstandsprüfungen - Nichttragende Unterdecken - Teil 7: Sandwichelemente in MetallbauweiseApplication étendue des résultats d´essais de résistance au feu - Plafonds non porteurs
Panneaux sandwiches métalliques pour la construction - Partie 7 : Panneaux sandwiches métalliques pour la constructionExtended application of results from fire resistance tests - Non-loadbearing ceilings — Part 7: Metal sandwich panel construction91.060.10Stene. Predelne stene. FasadeWalls. Partitions. Facades13.220.50Požarna odpornost gradbenih materialov in elementovFire-resistance of building materials and elementsICS:Ta slovenski standard je istoveten z:EN 15254-7:2012SIST EN 15254-7:2012en,fr,de01-november-2012SIST EN 15254-7:2012SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 15254-7
June 2012 ICS 13.220.50; 91.060.30 English Version
Extended application of results from fire resistance tests - Non-loadbearing ceilings - Part 7: Metal sandwich panel construction Application étendue des résultats d´essais de résistance au feu - Plafonds non porteurs - Partie 7: Panneaux sandwiches métalliques pour la construction
Erweiterter Anwendungsbereich der Ergebnisse von Feuerwiderstandsprüfungen - Nichttragende Unterdecken -Teil 7: Sandwichelemente in Metallbauweise This European Standard was approved by CEN on 4 May 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15254-7:2012: ESIST EN 15254-7:2012
EN 1364-2. This European Standard applies to self-supporting, double skin metal faced sandwich panels which have an insulating core bonded to both facings. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1363-1:2012, Fire resistance tests — Part 1: General requirements EN 1363-2, Fire resistance tests — Part 2: Alternative and additional procedures EN 1364-2:1999, Fire resistance tests for non-loadbearing elements — Part 2: Ceilings EN 1993-1-2, Eurocode 3. Design of steel structures — Part 1-2: General rules — Structural fire design EN 13501-2, Fire classification of construction products and building elements — Part 2: Classification using data from fire resistance tests, excluding ventilation services EN 14509:2006, Self-supporting double skin metal faced insulating panels — Factory made products — Specifications 3 Terms, definitions, symbols and abbreviations 3.1 Terms and definitions For the purpose of this document, the terms and definitions given in EN 14509:2006, EN 1364-2:1999, EN 1363-1:2012 and the following apply.
3.1.1 direct field of application of test results outcome of a process (involving the application of defined rules) whereby a test result is deemed to be equally valid for variations in one or more of the product properties and/or intended end use applications 3.1.2 extended field of application of test results outcome of a process (involving the application of defined rules that may incorporate calculation procedures) that predicts, for a variation of a product property and/or its intended end use application(s), a test result on the basis of one or more test results to the same test standard 3.1.3 factor one of the possible variations that may be applied to a parameter SIST EN 15254-7:2012
catenary force acting on the fasteners
Fv
vertical force due at g acting at the fastener FEd1
catenary force acting at the fastener at maximum temperature in the test
FEd2
catenary force acting at the fastener at temperature for the increased span
Fv1
vertical force due at g acting at the fastener at maximum temperature in the test
vertical force due at g acting at the fastener at temperature for the increased span
L
span length
T
temperature b
width of panel g
panel weight per square meter n
number of fasteners p
relative end movement in the fastener w
deflection of the ceiling α
linear coefficient of thermal expansion 4 Establishing the field of extended application 4.1 General An extended application analysis is required when the application differs i
...
Questions, Comments and Discussion