91.060.30 - Ceilings. Floors. Stairs
Ceilings. Floors. Stairs
Decken. Fuszboden. Treppen
Plafonds. Planchers. Escaliers
Stropi. Tla. Stopnice
General Information
This document specifies procedures to determine the impact sound insulation using sound pressure measurements with an impact source operating on a floor or stairs in a building. These procedures are intended for room volumes in the range from 10 m3 to 250 m3 in the frequency range from 50 Hz to 5 000 Hz. The test results can be used to quantify, assess and compare the impact sound insulation in unfurnished or furnished rooms where the sound field may or may not approximate to a diffuse field.
- Standard44 pagesEnglish language
sale 15% off- Standard45 pagesFrench language
sale 15% off- Draft44 pagesEnglish language
sale 15% off
This document specifies the characteristics of individual hardwood boards and pre-assembled hardwood boards with grooves and/or tongues for internal use as flooring. This document covers hardwood boards with or without surface coating.
This document does not cover solid parquet elements. (See Annex C).
- Standard25 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft25 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies a method, derived from the test, for determining the resistance to indentation of wood flooring.
- Standard10 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft9 pagesEnglish language
sale 10% off- e-Library read for1 day
This Europen Standard specifies test methods for the determination of the fundamental frequency, damping, unit point load deflection and acceleration of timber or wood based composite beams and flooring systems.
- Standard24 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies test methods for the determination of natural frequencies, damping, unit point load deflection and acceleration of floors composed of sawn timber, engineered wood products, and mass timber beams or slabs (e.g. cross laminated timber CLT, glued laminated timber GL, nail laminated timber), with or without concrete screeds, as well as for timber-concrete composite floors.
- Standard24 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of ISO 9705 specifies the test method to evaluate the reaction of wall and ceiling products to
fire when installed at the surface of a small room and exposed directly to a specified ignition source.
The test represents a fire scenario, which starts under well-ventilated conditions in a corner of a
specified room with a single open doorway.
Tests performed in accordance with the method specified in this part of ISO 9705 provide data
for the early stages of a fire from ignition up t...view more
- Standard45 pagesFrench language
sale 15% off- Standard42 pagesEnglish language
sale 15% off- Standard45 pagesFrench language
sale 15% off- Standard48 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a laboratory measurement method to determine noise radiated from a floor covering on a standard concrete floor when excited by a standard tapping machine.
- Standard18 pagesEnglish language
sale 10% off- e-Library read for1 day
This document defines rules for extended applications, provides guidance, and, where appropriate, specifies procedures, for variations of certain parameters and factors associated with the design of internal non-loadbearing ceilings constructed of metal faced sandwich panels that have been tested in accordance with EN 1364-2, which could generate a classification in accordance with EN 13501-2.
This document applies to self-supporting, double skin metal faced sandwich panels, which have an insul...view more
- Standard23 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of EN1364 specifies a method for determining the fire resistance of ceilings, which in themselves possess fire resistance independent of any building element above them. This standard is used in conjunction with EN 1363-1.
The method is applicable to ceilings, which are either suspended by hangers or fixed directly to a supporting frame or construction, and to self supporting ceilings.
Within this test method, the ceiling is exposed to fire, with the exposure being applied either:
...view more
- Standard24 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of EN 1364 specifies a method for determining the fire resistance of ceilings, which in themselves possess fire resistance independent of any building element above them. This European Standard is used in conjunction with EN 1363-1.
The method is applicable to ceilings, which are either suspended by hangers or fixed directly to a supporting frame or construction, and to self-supporting ceilings.
Within this test method, the ceiling is exposed to fire, with the exposure being applied ...view more
- Standard24 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the requirements for light transmitting single skin profiled plastics sheets for internal and external walls, roofs and ceilings. It is applicable to single skin sheets which are used as a single layer or when assembled to form a multiple layer construction.
It also specifies the test methods and provides for the evaluation of conformity and marking of the sheets.
- Standard58 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies additional necessary information how to carry out efficiently and under standardized conditions the determination of the sound absorption coefficients according to EN ISO 354 “Measurement of sound absorption in a reverberation room”. It specifies the additional requirements of the sound absorption measurements and the operating and mounting conditions that shall be used for the test. Observe that all demands in EN ISO 354 still must be fulfilled. The results obta...view more
- Standard18 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a method for determining the fire resistance of:
- floor constructions, without cavities or with unventilated cavities;
- roof constructions, with or without cavities (ventilated or unventilated);
- floor and roof constructions incorporating glazing;
with fire exposure from the underside.
This standard is used in conjunction with EN 1363-1.
- Standard28 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies additional necessary information on how to carry out efficiently and under standardized conditions the determination of the sound absorption coefficients according to EN ISO 354 “Measurement of sound absorption in a reverberation room”. It specifies the additional requirements of the sound absorption measurements and the operating and mounting conditions that should be used for the test. Observe that all demands in EN ISO 354 still should be fulfilled. The result...view more
- Standard18 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a method for determining the fire resistance of:
- floor constructions, without cavities or with unventilated cavities;
- roof constructions, with or without cavities (ventilated or unventilated);
- floor and roof constructions incorporating glazing;
with fire exposure from the underside.
This European Standard is used in conjunction with EN 1363-1.
- Standard28 pagesEnglish language
sale 10% off- e-Library read for1 day
This standard sets up a laboratory measurement method to determine the impact noise reduction of a floor covering when laid on a standard concrete floor mock-up and excited by a standard tapping machine. The method is restricted to floorings, which transmit impact sound mainly "locally" into the floor, i.e. through the area close to the points of excitation, so that the size of the flooring specimen does not have an influence on the results. Examples for such floors are carpets, PVC floorings, l...view more
- Standard18 pagesEnglish language
sale 10% off- e-Library read for1 day
EN 16481 constitutes a frame standard for the design of timber stairs as well as wood- and wood based components used in stairs by calculation methods. Some calculation methods can be derived from testing results, for example CEN/TS 15680.This document specifies the design and the requirements for materials and components to be used in these calculation methods. It may be complemented by national application documents based on this standard. This European Standard applies to coated and uncoated ...view more
- Standard58 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard constitutes a frame standard for the design of timber stairs as well as wood and wood-based components used in stairs by calculation methods. Some calculation methods can be derived from testing results, for example CEN/TS 15680. This document specifies the design and the requirements for materials and components to be used in these calculation methods. It may be complemented by national application documents based on this European Standard.
This European Standard applies...view more
- Standard58 pagesEnglish language
sale 10% off- e-Library read for1 day
EN 14076 defines general terms relating to timber stairs or to timber in prefabricated stairs, including wood-based materials for dwellings and buildings other than dwellings for permanent use.
- Standard28 pagesEnglish, French and German language
sale 10% off- e-Library read for1 day
This European Standard covers membranes, individual substructure components, substructure kits and suspended ceiling kits intended to be placed on the market. It covers suspended ceilings sold as a complete kit, substructures placed on the market as kits, individual components (products) of such substructures, and membrane components. It includes test methods and methods of assessment, as well as provisions for the evaluation of conformity and for the marking of the products to the requirements ...view more
- Standard129 pagesEnglish language
sale 10% off- e-Library read for1 day