ISS SPL.GPO - Building construction
Standardization of general terminology for buiding and civil engineering, general geometric requirements for building and building elements, general rules for joints, tolerances and other performance requirements for building and building elements.
Gradnja stavb
Standardizacija splošne terminologije za gradbeništvo, geometrijske zahteve za objekte in elemente, splošna pravila za stike, odstopanja in druge zahteve glede obnašanja objektov in elementov objektov.
General Information
This European Standard specifies product characteristics for demountable stands at permanent or temporary entertainment venues including sports stadiums, sport halls and indoor and outdoor facilities. This standard is not applicable to stands of a moveable type where last row of places for spectators is under 1 m height from the ground.
NOTE Amusement parks are covered by EN 13814, Fairground and amusement park machinery and structures - Safety.
- Standard22 pagesEnglish language
sales 10% off- e-Library read for1 day
- Draft22 pagesEnglish language
sales 10% off- e-Library read for1 day
This European Standard specifies principles and requirements for the mechanical resistance and stability,
serviceability and durability for design and construction of commercial production greenhouse structures
irrespective of material, including their foundations, for the professional production of plants and crops.
Fire resistance-related aspects are not covered in this standard.
- Standard96 pagesEnglish language
sales 10% off- e-Library read for1 day
- Draft92 pagesEnglish language
sales 10% off- e-Library read for1 day
This document contains the terms and definitions of general concepts to establish a vocabulary
applicable to buildings and civil engineering works.
It comprises:
a) fundamental concepts, which can be the starting point for other, more specific, definitions;
b) more specific concepts, used in several areas of construction and frequently used in standards,
regulations and contracts.
- Standard128 pagesEnglish language
sales 15% off- Standard133 pagesEnglish language
sales 10% off- e-Library read for1 day
This European Standard specifies design and management requirements for spectator facilities at permanent or temporary entertainment venues including sport stadia, sport halls, indoor and outdoor facilities for the purpose of enabling their functionality.
This European Standard is not applicable to other permanent venues such as theatres, cinemas, opera houses, auditoriums, lecture halls and similar places where persons congregate.
NOTE Provisions for media facilities are not included in this ...view more
- Standard32 pagesEnglish language
sales 10% off- e-Library read for1 day
This European Standard specifies design requirements for layout and product characteristics for separating elements within spectator accommodation at permanent or temporary entertainment venues including sport stadia, sport halls, indoor and outdoor facilities for the purpose of enabling their functionality.
Other permanent venues such as theatres, cinemas, opera houses, lecture halls and similar are excluded from this standard.
Elements and barriers included in this standard are:
a) barrier ...view more
- Standard28 pagesEnglish language
sales 10% off- e-Library read for1 day
This document specifies the definition and calculation of surface area and volume indicators.
In defining area measurement, this document uses three measurement concepts:
a) the intra-muros and extra-muros concept used in many parts of the world;
b) the wall centre method of measurement used in many parts of the world;
c) variations on these methods to comply with certain national laws or for particular types of
buildings.
The surface area and volume indicators defined in this document are...view more
- Standard23 pagesEnglish language
sales 15% off- Standard28 pagesEnglish language
sales 10% off- e-Library read for1 day
This document specifies a method for the determination of the change of mass and the change of volume of self-levelling and non-sagging sealants used in joints in building construction.
NOTE This test procedure is not intended to determine the absolute maximum value of loss of volume of a tested sealant, but it is an indicative measurement of the loss of volume under specified parameters.
- Draft7 pagesEnglish language
sales 10% off- e-Library read for1 day
- Standard11 pagesEnglish language
sales 10% off- e-Library read for1 day
This European standard specifies general characteristics regarding infrastructure and safety management in spectator facilities.
It specifies the layout and the planning of the management, the criteria to maintain this planning before, during and after any event.
It covers the following:
- the safety personnel;
- Safety Policy - A document developed, reviewed and monitored by the event organiser or senior management;
- Safety Procedures - An operational and emergency plan, containing roles ...view more
- Standard43 pagesEnglish language
sales 10% off- e-Library read for1 day
This part of ISO 15686 describes procedures that facilitate service life predictions of building components, based on technical and functional performance. It provides a general framework, principles and requirements for conducting and reporting such studies. It does not cover limitation of service life due to obsolescence or other non-measurable or unpredictable performance states.
- Standard26 pagesFrench language
sales 15% off- Standard25 pagesEnglish language
sales 15% off- Standard30 pagesEnglish language
sales 10% off- e-Library read for1 day
EN 13200-7 specifies safety and design characteristics of entry and exit elements of passage that are used in spectator facilities, either singularly or in combination, to provide a route.
- Standard35 pagesEnglish language
sales 10% off- e-Library read for1 day
This European Standard covers membranes, individual substructure components, substructure kits and suspended ceiling kits intended to be placed on the market. It covers suspended ceilings sold as a complete kit, substructures placed on the market as kits, individual components (products) of such substructures, and membrane components. It includes test methods and methods of assessment, as well as provisions for the evaluation of conformity and for the marking of the products to the requirements ...view more
- Standard129 pagesEnglish language
sales 10% off- e-Library read for1 day
This International Standard specifies a range of requirements and recommendations for many of the elements of construction, assemblies, components and fittings which comprise the built environment. These requirements relate to the constructional aspects of access to buildings, to circulation within buildings, to egress from buildings in the normal course of events and evacuation in the event of an emergency. An informative annex is also included which deals with aspects of accessibility manageme...view more
- Standard164 pagesFrench language
sales 15% off- Standard152 pagesEnglish language
sales 15% off- Standard162 pagesEnglish language
sales 10% off- e-Library read for1 day
- Standard – translation157 pagesSlovenian language
sales 10% off- e-Library read for1 day
This International Standard defines technical terms for self levelling, gun grade (gunnable) sealants for above ground structures exposed. These sealants do not include sealants used in roads and airfields, sealants for water retaining structures, or structural glazing sealants.
- Standard32 pagesEnglish, French and German language
sales 10% off- e-Library read for1 day
2010-11-09 EMA: // final draft provided to ISO/CS according to notification received in dataservice on 2010-11-09.
- Amendment7 pagesEnglish language
sales 10% off- e-Library read for1 day
TC - EN implementation of ISO Corrigendum ISO 9047:2001/Cor 1:2009.
- Corrigendum3 pagesEnglish language
sales 10% off- e-Library read for1 day
This Technical Report gives guidelines for a recommended strategy for efficiently combating the different types of crime liable to be committed against petrol stations.
- Technical report50 pagesEnglish language
sales 10% off- e-Library read for1 day
The purpose of this document is to describe the consequences and risks of the criminal use of motor vehicles against buildings or sites in order to better assess the threats and to establish a security analysis:
a) identification of possible attack methods,
b) recommendation of technical elements in the field of protection,
c) description of a set of physical protective measures to reinforce the security of public and private buildings,
d) recommendation of organizational measures.
This doc...view more
- Technical report48 pagesEnglish language
sales 10% off- e-Library read for1 day
This document sets out guidelines to the methods of assessing the exogenous and endogenous risks of crime and/or perceived insecurity and proposes measures designed to preclude or reduce these risks. The objective is to strengthen the overall security of land-based public transport, such as : bus stop, bus station, train station, train stops/halts, modal interchanges, open access underground and tramway systems, controlled access underground and tramway systems, taxi ranks, station car parks, ri...view more
- Technical report21 pagesEnglish language
sales 10% off- e-Library read for1 day
This Technical Report gives certain design solutions on how a spectator viewing area should be designed in order to cover people with disabilities and special needs.
- Technical report22 pagesEnglish language
sales 10% off- e-Library read for1 day
Specifies a method for the determination of the adhesion cohesion properties of sealants with predominantly elastic behaviour which are used in joints in building construction.
- Standard11 pagesEnglish language