EN 866-5:1999
(Main)Biological systems for testing sterilizers and sterilization processes - Part 5: Particular systems for use in low temperature steam and formaldehyde sterilizers
Biological systems for testing sterilizers and sterilization processes - Part 5: Particular systems for use in low temperature steam and formaldehyde sterilizers
This part of EN 866 specifies requirements for inoculated carriers and biological indicators intended for use in assessing the performance of sterilizers employing low temperature steam and formaldehyde as the sterilant over a sterilizing temperature range of 55° C to 80° C.
Biologische Systeme für die Prüfung von Sterilisatoren und Sterilisationsverfahren - Teil 5: Spezielle Systeme für den Gebrauch in Sterilisatoren mit Niedertemperatur-Dampf und Formaldehyd
Dieser Teil von EN 866 legt die Anforderungen an beimpfte Keimträger und biologische Indikatoren fest, die für die Beurteilung der Leistungsfähigkeit von Sterilisatoren vorgesehen sind, die mit Niedertemperatur-Dampf und Formaldehyd als Sterilisiermittel bei Sterilisationstemperaturen zwischen 55° C und 80° c arbeiten.
Systèmes biologiques pour l'essai des stérilisateurs et les procédés de stérilisation - Partie 5: Systèmes particuliers destinés à être utilisés dans des stérilisateurs à la vapeur d'eau et au formaldéhyde à basse température
La présente partie de la norme EN 866 spécifie les exigences pour les porte-germes inoculés et les indicateurs biologiques dont l'utilisation est prévue pour l'évaluation de la performance de stérilisateurs employant de la vapeur et du formaldéhyde à basse température comme agent de stérilisation sur une plage de température de stérilisation comprise entre 55° C et 80 °C.
Biološki sistemi za preskušanje sterilizatorjev in sterilizacijskih postopkov - 5. del: Posebni sistemi za uporabo sterilizacije s paro nizke temperature in s formaldehidom
General Information
- Status
- Withdrawn
- Publication Date
- 07-Dec-1999
- Withdrawal Date
- 30-Jun-2006
- Technical Committee
- CEN/TC 102 - Sterilizers for medical purposes
- Drafting Committee
- CEN/TC 102/WG 7 - Biological and chemical indicators
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Jul-2006
- Completion Date
- 01-Jul-2006
Relations
- Effective Date
- 22-Dec-2008
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

TÜV Rheinland
TÜV Rheinland is a leading international provider of technical services.

TÜV SÜD
TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.
Sponsored listings
Frequently Asked Questions
EN 866-5:1999 is a standard published by the European Committee for Standardization (CEN). Its full title is "Biological systems for testing sterilizers and sterilization processes - Part 5: Particular systems for use in low temperature steam and formaldehyde sterilizers". This standard covers: This part of EN 866 specifies requirements for inoculated carriers and biological indicators intended for use in assessing the performance of sterilizers employing low temperature steam and formaldehyde as the sterilant over a sterilizing temperature range of 55° C to 80° C.
This part of EN 866 specifies requirements for inoculated carriers and biological indicators intended for use in assessing the performance of sterilizers employing low temperature steam and formaldehyde as the sterilant over a sterilizing temperature range of 55° C to 80° C.
EN 866-5:1999 is classified under the following ICS (International Classification for Standards) categories: 11.080 - Sterilization and disinfection. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 866-5:1999 has the following relationships with other standards: It is inter standard links to EN ISO 11138-5:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 866-5:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-2000
Biološki sistemi za preskušanje sterilizatorjev in sterilizacijskih postopkov - 5. del:
Posebni sistemi za uporabo sterilizacije s paro nizke temperature in s
formaldehidom
Biological systems for testing sterilizers and sterilization processes - Part 5: Particular
systems for use in low temperature steam and formaldehyde sterilizers
Biologische Systeme für die Prüfung von Sterilisatoren und Sterilisationsverfahren - Teil
5: Spezielle Systeme für den Gebrauch in Sterilisatoren mit Niedertemperatur-Dampf
und Formaldehyd
Systemes biologiques pour l'essai des stérilisateurs et les procédés de stérilisation -
Partie 5: Systemes particuliers destinés a etre utilisés dans des stérilisateurs a la vapeur
d'eau et au formaldéhyde a basse température
Ta slovenski standard je istoveten z: EN 866-5:1999
ICS:
11.080.10 Sterilizacijska oprema Sterilizin
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...