- Abstract
This document specifies the structural performance requirements of curtain walling under wind load, both its fixed and openable parts, under positive and negative static air pressure.
This document applies to any curtain walling product as defined in EN 13830.
- Status
- Not Published
- Publication Date
- 21-Aug-2028
- Technical Committee
- CEN/TC 33 - Doors, windows, shutters and building hardware
- Drafting Committee
- CEN/TC 33/WG 6 - Curtain walling
- Current Stage
- 4020 - Submission to enquiry - Enquiry
- Start Date
- 03-Sep-2026
- Due Date
- 11-May-2027
- Completion Date
- 03-Sep-2026
EN 13116:2024/prA1 is a CEN draft amendment to EN 13116:2024 on curtain walling resistance to wind load. It updates the performance requirement for curtain walling under positive and negative static air pressure, for curtain walling products as defined in EN 13830. In practice, it is relevant to people who need a clear acceptance criterion for wind-load behaviour in façade design, testing, and specification.
What does EN 13116:2024/prA1 specify?
EN 13116:2024/prA1 specifies one change to the structural performance requirement for curtain walling under wind load. It focuses on serviceability performance at the design wind load stage, and it applies to both fixed and openable parts of the system.
The document is organized as a European foreword and one amendment clause. Clause 1 gives the replacement text for Clause 4.2 in EN 13116:2024, so the amendment is narrowly targeted at one performance requirement rather than rewriting the whole standard.
What are the key requirements of EN 13116:2024/prA1?
EN 13116:2024/prA1 changes the serviceability limit state criterion in Clause 4.2. The key practical point is that movement of framing members at support points must be kept very small after wind loading, so the façade remains acceptable in use.
The revised displacement criterion
Clause 1 replaces the third paragraph of 4.2 with a requirement that the displacement of framing members at points of support be minimized and kept below 2 mm. The displacement is assessed as the difference between the position after removal of the peak positive load and the position after removal of the peak negative load.
For users of the standard, this means the check is not just about how much the curtain walling deflects under load, but also about how much residual movement remains after the load is removed. That matters for appearance, operability, sealing, and the long-term fit of the curtain walling.
The timing of the measurement
The amendment also sets a time limit for the measurement: the displacement is measured no later than one hour after the load is removed. This matters because the result is tied to a defined recovery period, so test results and reported values are comparable between laboratories and projects.
Positive and negative wind loading
The requirement is based on both peak positive load and peak negative load. In practice, the curtain walling must be assessed for pressure and suction effects, since both directions of wind action can control the serviceability result.
Fixed and openable parts
The scope covers both fixed and openable parts of curtain walling. That means the criterion is relevant not only to static façade panels, but also to components that can move or open and that still need to perform within the same wind-load framework.
What terms does EN 13116:2024/prA1 define?
- Curtain walling - the façade product family covered by EN 13830, used as the basis for this wind-load performance requirement.
- Serviceability limit state - the condition where the curtain walling must remain fit for use, with deformation kept within acceptable limits.
- Design wind load - the wind load level used to assess serviceability performance.
- Peak positive load - the highest pressure load acting on the curtain walling in the positive direction.
- Peak negative load - the highest suction load acting on the curtain walling in the negative direction.
- Framing members - the structural members of the curtain walling frame whose movement at support points is checked.
- Displacement - the change in position of the framing members after the wind load has been removed.
Who uses EN 13116:2024/prA1?
Curtain walling manufacturers use this amendment when setting product performance criteria and preparing evidence for wind-load behaviour. Façade engineers and specifiers use it when defining acceptance limits for projects.
Test laboratories use it when measuring post-load movement and reporting results. Quality managers and buyers use it to compare supplier documentation, check conformance claims, and make sure the wind-load criterion matches the product they are purchasing or approving.
What changed in EN 13116:2024/prA1 from the previous edition?
EN 13116:2024/prA1 modifies EN 13116:2024 by replacing the third paragraph of Clause 4.2, “Performance under design wind load (serviceability limit state)”. The new text introduces a clearer displacement limit at support points and ties the measurement to the positions after removal of the peak positive and peak negative loads.
Which standards are used with EN 13116:2024/prA1?
EN 13830 is named in the scope and defines the curtain walling product family to which this document applies. EN 13116:2024 is the base standard that this amendment modifies, so the two are used together.
What does the EN 13116:2024/prA1 document contain?
The document contains a European foreword and one amendment clause. The foreword identifies it as a draft amendment prepared by CEN/TC 33 and submitted for enquiry.
Clause 1 gives the replacement text for Clause 4.2 of EN 13116:2024. The content is focused on one serviceability requirement, so it is a short amendment intended for direct use in design checks, testing, and conformity assessment of curtain walling under wind load.
Relations
- Effective Date
- 24-Jun-2026
Get Certified
Connect with accredited certification bodies for this standard
DIBt (Deutsches Institut für Bautechnik)
German Institute for Building Technology.
DIN CERTCO
DIN Group product certification.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
Sponsored listings
Frequently Asked Questions
EN 13116:2024/prA1 is a draft published by the European Committee for Standardization (CEN). Its full title is "Curtain walling - Resistance to wind load - Performance requirements". This standard covers: This document specifies the structural performance requirements of curtain walling under wind load, both its fixed and openable parts, under positive and negative static air pressure. This document applies to any curtain walling product as defined in EN 13830.
This document specifies the structural performance requirements of curtain walling under wind load, both its fixed and openable parts, under positive and negative static air pressure. This document applies to any curtain walling product as defined in EN 13830.
EN 13116:2024/prA1 is classified under the following ICS (International Classification for Standards) categories: 91.060.10 - Walls. Partitions. Facades. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 13116:2024/prA1 has the following relationships with other standards: It is inter standard links to EN 13116:2024. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 13116:2024/prA1 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-november-2026
Obešene fasade - Odpornost proti obremenitvi z vetrom - Zahtevane lastnosti -
Dopolnilo A1
Curtain walling - Resistance to wind load - Performance requirements
Vorhangfassaden - Widerstand gegen Windlast - Leistungsanforderungen
Façades rideaux - Résistance au vent - Prescriptions de performance
Ta slovenski standard je istoveten z: EN 13116:2024/prA1
ICS:
91.060.10 Stene. Predelne stene. Walls. Partitions. Facades
Fasade
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
EN 13116:2024
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
September 2026
ICS 91.060.10
English Version
Curtain walling - Resistance to wind load - Performance
requirements
Façades rideaux - Résistance au vent - Prescriptions de Vorhangfassaden - Widerstand gegen Windlast -
performance Leistungsanforderungen
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 33.
This draft amendment A1, if approved, will modify the European Standard EN 13116:2024. If this draft becomes an amendment,
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of
this amendment into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Swit
...