SIST EN 13116:2024/oprA1:2026
(Amendment)Curtain walling - Resistance to wind load - Performance requirements
- Abstract
This document specifies the structural performance requirements of curtain walling under wind load, both its fixed and openable parts, under positive and negative static air pressure.
This document applies to any curtain walling product as defined in EN 13830.
- Status
- Not Published
- Public Enquiry End Date
- 19-Nov-2026
- Technical Committee
- ISTP - Doors and windows
- Current Stage
- 4020 - Public enquire (PE) (Adopted Project)
- Start Date
- 02-Oct-2026
- Due Date
- 19-Feb-2027
SIST EN 13116:2024/oprA1:2026 is the Slovenian draft amendment to EN 13116:2024 on curtain walling resistance to wind load. It specifies structural performance requirements for curtain walling under positive and negative static air pressure, including fixed and openable parts, and is aimed at people who design, test, specify, or verify curtain walling products defined in EN 13830.
What does SIST EN 13116:2024/oprA1:2026 specify?
SIST EN 13116:2024/oprA1:2026 is a draft amendment to the wind-load performance standard for curtain walling. It keeps the focus on structural performance under wind load and updates the serviceability requirement in clause 4.2.
The document is organized as a European foreword and one modification clause. The foreword identifies the responsible CEN committee and states that the draft amendment will modify EN 13116:2024 if approved.
What are the key requirements of SIST EN 13116:2024/oprA1:2026?
SIST EN 13116:2024/oprA1:2026 applies to any curtain walling product as defined in EN 13830. In practice, that means the scope follows the curtain walling product definition used across the European façade field.
The standard covers structural performance under wind load for both fixed and openable parts. For a project team, that means the whole curtain walling system has to be considered, not only the non-opening areas.
It addresses both positive and negative static air pressure. This matters because the façade must be checked for wind pushing inward and pulling outward, not just one loading direction.
Clause 4.2, “Performance under design wind load (serviceability limit state),” is the point changed by this amendment. The revised paragraph requires the displacement of framing members at points of support to be kept very small and to stay below the stated limit, measured as the difference between the position after removal of the peak positive load and the position after removal of the peak negative load.
The same clause also fixes how the measurement is taken. The positions are to be recorded no later than one hour after load removal, which matters for test planning and for comparing results between laboratories or product configurations.
Because the requirement sits in the serviceability limit state part of the standard, the concern is usable performance under load rather than ultimate failure. For manufacturers and specifiers, this means the acceptance check is about residual movement and service behavior after wind loading.
What terms does SIST EN 13116:2024/oprA1:2026 define?
Curtain walling is the façade product covered by this standard and is the product type defined in EN 13830.
Wind load is the action from wind that produces pressure on the curtain walling system.
Positive static air pressure is the pressure direction that pushes the façade inward.
Negative static air pressure is the pressure direction that pulls the façade outward.
Serviceability limit state is the performance condition used here to judge whether the curtain walling remains suitably usable under load.
Framing members are the structural members of the curtain walling frame whose movement is checked in clause 4.2.
Who uses SIST EN 13116:2024/oprA1:2026?
SIST EN 13116:2024/oprA1:2026 is used by curtain wall manufacturers, façade designers, testing laboratories, project engineers, quality managers, and purchasers who need a clear wind-load performance requirement. It is also relevant to specifiers and conformity assessment teams that must document how a curtain walling product behaves under design wind load.
What changed in SIST EN 13116:2024/oprA1:2026 from the previous edition?
Compared with EN 13116:2024, this draft amendment changes the third paragraph of clause 4.2. The update refines the serviceability requirement by defining how displacement at support points is judged after peak positive and negative loading and by keeping the post-load measurement window tied to one hour after load removal.
Which standards are used with SIST EN 13116:2024/oprA1:2026?
EN 13830 provides the product definition that sets the scope of this standard. EN 13116:2024 is the base standard that this amendment modifies, so readers need it alongside this document to apply the updated clause 4.2.
What does the SIST EN 13116:2024/oprA1:2026 document contain?
The document contains a European foreword and one modification instruction. The foreword identifies CEN/TC 33 and states that the draft is under CEN enquiry.
The body gives the replacement wording for the third paragraph of clause 4.2. In practice, it is a focused update to one wind-load serviceability requirement rather than a full rewrite of the standard.
It is used together with EN 13116:2024 when reviewing façade design, test reports, or product performance claims.
Relations
- Effective Date
- 24-Jun-2026
Get Certified
Connect with accredited certification bodies for this standard
DIBt (Deutsches Institut für Bautechnik)
German Institute for Building Technology.
DIN CERTCO
DIN Group product certification.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
Sponsored listings
Frequently Asked Questions
SIST EN 13116:2024/oprA1:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Curtain walling - Resistance to wind load - Performance requirements". This standard covers: This document specifies the structural performance requirements of curtain walling under wind load, both its fixed and openable parts, under positive and negative static air pressure. This document applies to any curtain walling product as defined in EN 13830.
This document specifies the structural performance requirements of curtain walling under wind load, both its fixed and openable parts, under positive and negative static air pressure. This document applies to any curtain walling product as defined in EN 13830.
SIST EN 13116:2024/oprA1:2026 is classified under the following ICS (International Classification for Standards) categories: 91.060.10 - Walls. Partitions. Facades. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 13116:2024/oprA1:2026 has the following relationships with other standards: It is inter standard links to SIST EN 13116:2024. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 13116:2024/oprA1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-november-2026
Obešene fasade - Odpornost proti obremenitvi z vetrom - Zahtevane lastnosti -
Dopolnilo A1
Curtain walling - Resistance to wind load - Performance requirements
Vorhangfassaden - Widerstand gegen Windlast - Leistungsanforderungen
Façades rideaux - Résistance au vent - Prescriptions de performance
Ta slovenski standard je istoveten z: EN 13116:2024/prA1
ICS:
91.060.10 Stene. Predelne stene. Walls. Partitions. Facades
Fasade
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
EN 13116:2024
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
September 2026
ICS 91.060.10
English Version
Curtain walling - Resistance to wind load - Performance
requirements
Façades rideaux - Résistance au vent - Prescriptions de Vorhangfassaden - Widerstand gegen Windlast -
performance Leistungsanforderungen
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 33.
This draft amendment A1, if approved, will modify the European Standard EN 13116:2024. If this draft becomes an amendment,
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of
this amendment into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Swit
...