Non-destructive testing - Thermographic testing - Part 2: Equipment

This European Standard describes properties and requirements of infrared cameras used for thermographic testing for non-destructive testing.
This document gives also examples of excitation sources, the properties and requirements are described in application standards for active thermography.

Zerstörungsfreie Prüfung - Thermografische Prüfung - Teil 2: Geräte

Diese Europäische Norm legt Eigenschaften von und Anforderungen an Infrarot-Kameras (IR-Kameras) fest, die bei der thermografischen Untersuchung im Rahmen der zerstörungsfreien Prüfung eingesetzt werden.
Dieses Dokument liefert auch Beispiele für Anregungsquellen, deren Eigenschaften und Anforderungen in den Anwendungsnormen für die aktive Thermografie beschrieben sind.

Essais non destructifs - Examen par thermographie - Partie 2 : Équipement

Neporušitveno preskušanje - Termografsko preskušanje - 2. del: Oprema

Ta standard opisuje lastnosti in zahteve naprav, ki se uporabljajo za termografijo neporušitvenega preskušanja.

General Information

Status
Published
Publication Date
09-Aug-2016
Withdrawal Date
27-Feb-2017
Current Stage
9060 - Closure of 2 Year Review Enquiry - Review Enquiry
Start Date
04-Mar-2022
Completion Date
04-Mar-2022

Buy Standard

Standard
EN 16714-2:2016
English language
18 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Neporušitveno preskušanje - Termografsko preskušanje - 2. del: OpremaZerstörungsfreie Prüfung - Thermografische Prüfung - Teil 2: GeräteEssais non destructifs - Essais thermographiques - Partie 2: EquipementNon-destructive testing - Thermographic testing - Part 2: Equipment19.100Neporušitveno preskušanjeNon-destructive testingICS:Ta slovenski standard je istoveten z:EN 16714-2:2016SIST EN 16714-2:2016en,fr,de01-november-2016SIST EN 16714-2:2016SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 16714-2
August
t r s x ICS
s {ä s r r English Version
Nonædestructive testing æ Thermographic testing æ Part
tã Equipment Essais non destructifs æ Analyses thermographiques æ Partie
tã Equipement
Zerstörungsfreie Prüfung æ Thermografische Prüfung æ Teil
tã Geräte This European Standard was approved by CEN on
t w June
t r s xä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
t r s x CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s x y s væ tã t r s x ESIST EN 16714-2:2016

wavelength between approx. 2,0 µm and 5,0 µm; — long Wave, LW: wavelength between approx. 8,0 µm and 14,0 µm. 4.2.2 Temperature range The temperature range is the interval between lowest and highest measurable temperature. The range should be specified for black-body temperatures (emissivity = 1). NOTE 1 Temperature range means the total temperature range, which can consist of several partial measurement ranges that can be adjusted separately at the device. NOTE 2 The use of optical components like spectral filters can alter the measurable temperature range. 4.2.3 Thermal resolution The thermal resolution describes the ability of an IR camera to resolve small temperature differences. The thermal resolution is commonly described by the noise equivalent temperature difference (NETD, see A.5). The thermal resolution depends among others on: — the object temperature; — the integration time or response time; — the temperature range. Therefore, it shall be specified at least with indication of these values. The required thermal resolution depends strongly on the application. SIST EN 16714-2:2016
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.