This document defines terms used in ultrasonic testing with arrays. This includes phased array technology and signal processing technology using arrays, e. g. the full-matrix capture (FMC) (3.3.1.28) and the total focusing technique (TFM) (3.3.1.35).

    • sale 15% off
    • Standard
      20 pages
      French language
    • sale 15% off
    • Draft
      22 pages
      French language
    • sale 15% off
    • Standard
      20 pages
      English language
    • sale 15% off
    • Draft
      20 pages
      English language
    • sale 15% off
    • Draft
      19 pages
      French language
    • sale 15% off
    • Draft
      17 pages
      English language

This document provides general principles for thermoelastic stress measuring method of infrared thermographic testing in the field of industrial non-destructive testing (NDT).

    • sale 15% off
    • Standard
      9 pages
      English language
    • sale 15% off
    • Draft
      9 pages
      English language
    • sale 15% off
    • Draft
      8 pages
      English language

This document describes the test method for determining residual stresses in polycrystalline materials
by neutron diffraction. It is applicable to both homogeneous and inhomogeneous materials including
those containing distinct phases.
The principles of the neutron diffraction technique are outlined. Suggestions are provided on:
— the selection of appropriate diffracting lattice planes on which measurements should be made for
different categories of materials,
— the specimen directions in ...
view more

    • sale 10% off
    • Standard
      55 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      52 pages
      English language
    • e-Library read for
      1 day

This International Standard covers probes used for ultrasonic testing in the following categories with centre frequencies in the range 0,5 MHz to 15 MHz, focusing and without focusing means:
a) single or dual-transducer contact probes generating longitudinal or transverse waves;
b) single-transducer immersion probes generating longitudinal waves.

    • sale 10% off
    • Standard
      64 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      59 pages
      English language
    • e-Library read for
      1 day

This International Standard specifies methods and acceptance criteria for assessing the electrical performance of analogue and digital ultrasonic instruments for pulse operation using A-scan display, employed for manual ultrasonic non-destructive testing with single or dual-transducer probes operating within the centre frequency range 0,5 MHz to 15 MHz. Ultrasonic instruments for continuous waves are not included in this standard. This standard may partly be applicable to ultrasonic instruments ...view more

    • sale 10% off
    • Standard
      48 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      46 pages
      English language
    • e-Library read for
      1 day

This document specifies methods, tolerances and acceptance criteria for verifying the performance of combined ultrasonic test equipment (i.e. instrument, probes and cables connected) by the use of appropriate standard calibration blocks. These methods are specifically intended for manual test equipment, i.e. ultrasonic instruments according to ISO 22232-1, and for manual ultrasonic non-destructive testing with single- or dual-transducer probes according to ISO 22232-2. This document is also appl...view more

    • sale 15% off
    • Draft
      10 pages
      French language
    • sale 15% off
    • Standard
      10 pages
      English language
    • sale 15% off
    • Standard
      11 pages
      French language
    • sale 15% off
    • Draft
      10 pages
      English language

This document specifies the characteristics of probes used for non-destructive ultrasonic testing in the following categories with centre frequencies in the range of 0,5 MHz to 15 MHz, focusing or without focusing means: a) single- or dual-transducer contact probes generating longitudinal and/or transverse waves; b) single-transducer immersion probes. Where material-dependent ultrasonic values are specified in this document they are based on steels having a sound velocity of (5 920 ± 50) m/s for...view more

    • sale 15% off
    • Standard
      56 pages
      English language
    • sale 15% off
    • Standard
      56 pages
      French language
    • sale 15% off
    • Draft
      56 pages
      French language
    • sale 15% off
    • Draft
      56 pages
      English language

This document specifies methods and acceptance criteria within the frequency range of 0,5 MHz to 15 MHz, for assessing the electrical performance of digital ultrasonic instruments for pulse operation using A-scan display, for manual ultrasonic non-destructive testing with single- or dual-transducer probes. This document is also applicable for multi-channel instruments. This document can partly be applicable to ultrasonic instruments in automated systems, but other tests can be needed to ensure s...view more

    • sale 15% off
    • Standard
      40 pages
      English language
    • sale 15% off
    • Standard
      42 pages
      French language
    • sale 15% off
    • Draft
      40 pages
      English language

This document is used for non-destructive testing by the gamma ray scanning method for troubleshooting and testing process columns in industries. This document is applicable to the testing of all kinds of separation processes columns and pipes. This includes columns with different tray configurations and with packed beds.

    • sale 15% off
    • Standard
      27 pages
      English language
    • sale 15% off
    • Draft
      27 pages
      English language

ISO 16526-2:2011 specifies a constancy check of a X-ray system where mainly the X-ray voltage is checked and also the tube current and the constitution of the target which can be changing due to ageing of the tube.
The thick filter method is based on a measurement of the dose rate behind a defined thick filter using defined distances between the X-ray tube, the filter and the measuring device.
This method is very sensitive to changes of the voltage, but it does not provide an absolute value fo...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      10 pages
      English language
    • e-Library read for
      1 day

ISO 16526-1:2011 specifies a method for the direct and absolute measurement of the average high voltage of constant potential (DC) X-ray systems on the secondary side of the high voltage generator. The intention is to check the correspondence with the indicated high voltage value on the control unit of the X-ray system.
This method is applied to assure a reproducible operation of X-ray systems because the voltage influences particularly the penetration of materials and the contrast of X-ray ima...
view more

    • sale 10% off
    • Standard
      10 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      7 pages
      English language
    • e-Library read for
      1 day

ISO 14096-1:2005 specifies procedures for the evaluation of basic performance parameters of the radiographic film digitisation process such as spatial resolution and spatial linearity, density range, density contrast sensitivity and characteristic transfer curve. They can be integrated into the system software and together with a standard reference film used for quality control of the digitisation process. This reference film provides a series of test targets for performance evaluation. The test...view more

    • sale 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      17 pages
      English language
    • e-Library read for
      1 day

ISO 16526-3:2011 specifies the test method for a non-invasive measurement of X-ray tube voltages using the energy spectrum of X-rays (spectrometric method). It covers the voltage range from 10 kV to 500 kV.
The intention is to check the correspondence of the actual voltage with the indicated value on the control panel of the X-ray unit. It is intended to measure the maximum energy only and not the complete X-ray spectrum.
The procedure is applicable for tank type and constant potential X-ray u...
view more

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      11 pages
      English language
    • e-Library read for
      1 day

ISO 14096-2:2005 specifies three film-digitisation quality classes for the requirements of non-destructive testing. The selected class depends on the radiation energy, penetrated material thickness and the quality level of the original radiographic film. ISO 14096-2:2005 does not address signal processing, display and storage of the digitised data.

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      10 pages
      English language
    • e-Library read for
      1 day

This document is applicable to testing of rails installed in track for detecting rail surface cracks. This part of this European Standard applies to testing equipment in inspection-trains or reprofiling machines and manual systems. This document specifies the requirement for testing principles and systems in order to produce comparable results in respect to the location and the characteristic of surface cracks. This document is not aiming to give any guidelines for managing the result of eddy cu...view more

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      32 pages
      English language
    • e-Library read for
      1 day

ISO 16526-1:2011 specifies a method for the direct and absolute measurement of the average high voltage of constant potential (DC) X-ray systems on the secondary side of the high voltage generator. The intention is to check the correspondence with the indicated high voltage value on the control unit of the X-ray system.
This method is applied to assure a reproducible operation of X-ray systems because the voltage influences particularly the penetration of materials and the contrast of X-ray ima...
view more

    • sale 10% off
    • Standard
      10 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      7 pages
      English language
    • e-Library read for
      1 day

ISO 16526-3:2011 specifies the test method for a non-invasive measurement of X-ray tube voltages using the energy spectrum of X-rays (spectrometric method). It covers the voltage range from 10 kV to 500 kV.
The intention is to check the correspondence of the actual voltage with the indicated value on the control panel of the X-ray unit. It is intended to measure the maximum energy only and not the complete X-ray spectrum.
The procedure is applicable for tank type and constant potential X-ray u...
view more

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      11 pages
      English language
    • e-Library read for
      1 day

ISO 16526-2:2011 specifies a constancy check of a X-ray system where mainly the X-ray voltage is checked and also the tube current and the constitution of the target which can be changing due to ageing of the tube.
The thick filter method is based on a measurement of the dose rate behind a defined thick filter using defined distances between the X-ray tube, the filter and the measuring device.
This method is very sensitive to changes of the voltage, but it does not provide an absolute value fo...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      10 pages
      English language
    • e-Library read for
      1 day

This document specifies the requirements for penetrant testing of metallic materials for aerospace applications. It is limited to the direction of surface breaking defects, e.g. cracks, laps, seams and inclusions.
It shall be applied when referred to in the EN technical specification or material standard unless otherwise specified on the drawing, order or inspection schedule.

    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day

This document describes the test method for determining residual stresses in polycrystalline materials by neutron diffraction. It is applicable to both homogeneous and inhomogeneous materials including those containing distinct phases. The principles of the neutron diffraction technique are outlined. Suggestions are provided on: — the selection of appropriate diffracting lattice planes on which measurements should be made for different categories of materials, — the specimen directions in which ...view more

    • sale 15% off
    • Standard
      45 pages
      English language
    • sale 15% off
    • Standard
      47 pages
      French language