EN 13501-2:2023/prA1
(Amendment)Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance and/or smoke control tests, excluding ventilation services
Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance and/or smoke control tests, excluding ventilation services
This document specifies the procedure for classification of construction products and building elements using data from fire resistance and/or smoke leakage/control tests and/or mechanical tests which are within the direct field of application of the relevant test method. Classification on the basis of extended application of test results is also included in the scope of this document.
This document deals with:
a) loadbearing elements without a fire separating function:
- walls;
- floors;
- roofs;
- beams;
- columns;
- balconies;
- walkways;
- stairs.
b) loadbearing elements with a fire separating function, with or without glazing, services and fixtures:
- walls;
- floors;
- roofs;
- raised floors.
c) products and systems for protecting elements or parts of the works:
- ceilings with no independent fire resistance;
- fire protective coatings, claddings and screens;
d) non-loadbearing elements or parts of works, with or without glazing, services and fixtures:
- partitions;
- facades (curtain walls) and external walls;
- ceilings with independent fire resistance;
- raised floors;
- fire resisting doorsets, shutter assemblies and openable windows and their closing devices;
- smoke control doorsets and shutter assemblies and their closing devices;
- conveyor systems and their closures;
- penetration seals;
- linear joint seals;
- combined penetration seals;
- service ducts and shafts;
- air transfer grilles.
- chimneys.
e) wall and ceiling coverings with fire protection ability.
f) lift landing doors which are tested according to EN 81-58 are excluded from this document. Lift landing doors which are tested in accordance with EN 1634-1 are classified in accordance with 7.5.5.
Relevant test methods which have been prepared for these construction products are listed in Clauses 2 and 7.
Klassifizierung von Bauprodukten und Bauteilen zu ihrem Brandverhalten - Teil 2: Klassifizierung mit den Ergebnissen aus den Feuerwiderstandsprüfungen und/oder Rauchschutzprüfungen, mit Ausnahme von Lüftungsanlagen
Classement au feu des produits et éléments de construction - Partie 2 : Classement à partir des données d’essais de résistance au feu et/ou de contrôle des fumées à l’exclusion des produits utilisés dans les systèmes de ventilation
Požarna klasifikacija gradbenih proizvodov in elementov stavb - 2. del: Klasifikacija na podlagi podatkov iz preskusov požarne odpornosti in/ali dimotesnosti, izvzete so prezračevalne naprave - Dopolnilo A1
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2026
Požarna klasifikacija gradbenih proizvodov in elementov stavb - 2. del:
Klasifikacija na podlagi podatkov iz preskusov požarne odpornosti in/ali
dimotesnosti, izvzete so prezračevalne naprave - Dopolnilo A1
Fire classification of construction products and building elements - Part 2: Classification
using data from fire resistance and/or smoke control tests, excluding ventilation services
Klassifizierung von Bauprodukten und Bauteilen zu ihrem Brandverhalten - Teil 2:
Klassifizierung mit den Ergebnissen aus den Feuerwiderstandsprüfungen und/oder
Rauchschutzprüfungen, mit Ausnahme von Lüftungsanlagen
Classement au feu des produits et éléments de construction - Partie 2 : Classement à
partir des données d’essais de résistance au feu et/ou de contrôle des fumées à
l’exclusion des produits utilisés dans les systèmes de ventilation
Ta slovenski standard je istoveten z: EN 13501-2:2023/prA1
ICS:
13.220.50 Požarna odpornost Fire-resistance of building
gradbenih materialov in materials and elements
elementov
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
EN 13501-2:2023
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
November 2025
ICS
English Version
Fire classification of construction products and building
elements - Part 2: Classification using data from fire
resistance and/or smoke control tests, excluding
ventilation services
Classement au feu des produits et éléments de Klassifizierung von Bauprodukten und Bauteilen zu
construction - Partie 2 : Classement à partir des ihrem Brandverhalten - Teil 2: Klassifizierung mit den
données d'essais de résistance au feu et/ou de contrôle Ergebnissen aus den Feuerwiderstandsprüfungen
des fumées à l'exclusion des produits utilisés dans les und/oder Rauchschutzprüfungen, mit Ausnahme von
systèmes de ventilation Lüftungsanlagen
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 127.
This draft amendment A1, if approved, will modify the European Standard EN 13501-2:2023. If this draft becomes an
amendment, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for
inclusion of this amendment into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13501-2:2023/prA1:2025 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
1 Modification to “Introduction” . 4
2 Modification to Clause 2, "Normative References" . 4
3 Modification to Clause 4, "Fire Scenarios" . 4
4 Modification to Clause 5, "Resistance to fire performance characteristics" . 4
5 Modification to Clause 6, "Classification of characteristics related to fire resistance
performance”. 5
6 Modification to Clause 7, "Classification procedure for fire resistance” . 5
7 Modification to Clause A.1, “A.1 General” . 8
8 Modification to Clause A.2, “A.2 Content and Format”. 8
9 Modification to Table B.2, “Table B.2 – Example of tabulated data”. 9
European foreword
This document (EN 13501-2:2023/prA1:2025) has been prepared by Technical Committee CEN/TC 127
“Fire safety in buildings”, the secretariat of which is held by BSI.
This document is currently submitted to the CEN Enquiry.
1 Modification to “Introduction”
Replace
“CEN, CENELEC and EOTA committees preparing technical specifications which contain performance
requirements against fire resistance tests are expected to refer to the fire resistance classification given
in this document and not refer directly to any specific fire test method.”
with
“Commission delegated regulation (EU) 2024/1681 of 6 March 2024 specifies performance and classes
regarding fire resistance. These classes are identified by designation letters, each of which refers to an
important characteristic of fire resistance behaviour.”
2 Modification to Clause 2, "Normative References"
Replace
“EN 12604, Industrial, commercial and garage doors and gates — Mechanical aspects — Requirements and
test methods”
with
“EN 12605: 2000, Industrial, commercial and garage doors and gates —Mechanical aspects — Test
methods”
3 Modification to Clause 4, "Fire Scenarios"
Replace the word “doors” with “doorsets” throughout Clause 4.
In clause 4.6 bullet point 1 replace “leakage” with “air flow”.
In clause 4.6 bullet point 2 replace “leakage” with “air flow”.
At end of section 4.6 add the following note:
“NOTE Instead of air flow rate, the term leakage rate was used to describe the evaluation of ambient and medium
temperature for smoke control doorsets in former versions of this document.”
4 Modification to Clause 5, "Resistance to fire performance characteristics"
In clause 5.1, at end of second sentence, add “/control” after “smoke leakage”.
In clause 5.2.2.1 in second sentence of first paragraph replace “may” with “can”
In clause 5.2.3.3 replace the word “doorsests” with “doorsets”.
In clause 5.2.4 in the last sentence replace “thermal insulation” with “radiation”
In clause 5.2.7, after the first sentence, delete all text and replace with the following:
“S is the classification related to the air flow rate at ambient temperature and in the case the doorset
a3
was tested with the bottom gap taped over.
S is the classification related to the air flow rate at ambient temperature and in the case the doorset was
a4
tested without the bottom gap taped over.
S is the classification for the air flow rate at both ambient temperature and at 200°C.
S is the classification for the air flow rate at both ambient temperature and at 200°C and may be used
200L
for large industrial doorsets only. Large industrial doorsets have an overall door leaf area of more than
9m .
NOTE 1 The classification S is defined in previous versions of this document.
a
NOTE 2 The classification S is defined in previous versions of this document.”
m
5 Modification to Clause 6, "Classification of characteristics related to fire
resistance performance”
In clause 6.6.2 replace the text for S definition with the following:
“for elements with particular limitations on smoke leakage/control;
For fire resistant elements the S shall be added to the fire resistance classification (e.g. EI 60-
S ). Where no fire resistance classification is relevant, the element shall simply be classified S
as defined in this document for the particular product and classification;”
6 Modification to Clause 7, "Classification procedure for fire resistance”
In clause 7.1.1 a) “load level (see 3.26)” is to be a separate bullet point
In clause 7.1.1 c) replace the word “doorsests” with “doorsets”.
In clause 7.1.1 d) add “/control” after “smoke leakage” and “/air flow” after “limiting leakage” and before
“rate”.
In clause 7.2.2.3 replace the word “both” with “one”.
In section 7.3.2.4 move “With external fire exposure, the classification shall be given as REI 30-ef, or
REI 60-ef (o→i).” to the end of the paragraph above.
nd
In table 4 in clause 7.3.4.4 delete the 10-minute classification column (2 column) for both RE and REI.
In clause 7.5.2.1 delete “EN 15254-6 and”.
In clause 7.5.2.2 delete “and EN 15254- 6” and insert “EN 15254-3” between “EN 15254-2” and “EN 15254-
4”, and insert “and” between “EN 15254-4” and “EN 15254
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.