Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents

This European Standard specifies general requirements for the performance of procedures for the determination of the concentration of chemical agents in workplace atmospheres as required by the Chemical Agents Directive 98/24/EC (see reference [9]). The requirements given apply to all measuring procedures, irrespective of the physical form of the chemical agent (gas, vapour, airborne particles), the sampling method and the analytical method used.
This European Standard is applicable to
-   all steps of a measuring procedure,
-   measuring procedures with separate sampling and analysis steps, and
-   direct-reading devices.

Exposition am Arbeitsplatz - Allgemeine Anforderungen an die Leistungsfähigkeit von Verfahren zur Messung chemischer Arbeitsstoffe

Diese Europäische Norm legt allgemeine Anforderungen an die Leistungsfähigkeit von Messverfahren zur Bestimmung der Konzentration chemischer Arbeitsstoffe in der Arbeitsplatzatmosphäre fest, wie seitens der Richtlinie über chemische Arbeitsstoffe 98/24/EG (siehe Literaturhinweis [7]) gefordert. Diese Anforderungen gelten für alle Messverfahren, unabhängig vom physikalischen Zustand des chemischen Arbeitsstoffes (Gas, Dampf, luftgetragene Partikel), vom Probenahmeverfahren und vom eingesetzten Analyseverfahren. Diese Europäische Norm gilt für
- alle Schritte eines Messverfahrens,
- Messverfahren mit voneinander unabhängigen Probenahme- und Analyseschritten, und
- direkt anzeigende Messgeräte.

Exposition sur les lieux de travail - Exigences générales concernant les performances des procédures de mesure des agents chimiques

La présente Norme européenne stipule les exigences générales de performances pour les procédures
servant à déterminer la concentration des agents chimiques dans les atmosphères des lieux de travail comme
demandé dans la Directive relative aux agents chimiques 98/24/CE (voir référence [7]). Ces exigences sont
applicables à toutes les procédures de mesure, indépendamment de la forme physique de l’agent chimique
(gaz, vapeur, particules en suspension dans l'air), de la méthode de prélèvement ou d’analyse employée.
La présente Norme européenne est applicable :
- à toutes les étapes d’une procédure de mesure ;
- aux procédures de mesure pour lesquelles le prélèvement et l’analyse sont deux étapes distinctes ; et
- aux dispositifs à lecture directe.

Izpostavljenost na delovnem mestu - Splošne zahteve za izvajanje meritev kemičnih agensov

Ta evropski standard določa splošne zahteve za izvajanje meritev kemičnih agensov v ozračju na delovnem mestu v skladu z zahtevami Direktive Sveta 98/24/ES o kemičnih dejavnikih (glejte sklic [9]). Podane zahteve se nanašajo na vse merilne postopke, ne glede na fizično obliko kemičnega agensa (plin, para, lebdeči delci) ter uporabljeno metodo vzorčenja in analitično metodo.
Ta evropski standard se uporablja za:
– vse faze merilnega postopka,
– merilne postopke z ločenimi fazami vzorčenja in analize ter
– naprave, ki omogočajo neposredno odčitavanje.

General Information

Status
Withdrawn
Publication Date
20-Oct-2015
Withdrawal Date
20-Jan-2026
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
17-Mar-2021
Completion Date
21-Jan-2026

Relations

Effective Date
19-Jan-2023
Effective Date
18-Jan-2023
Effective Date
21-Feb-2018
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026

Get Certified

Connect with accredited certification bodies for this standard

NSF International

Global independent organization facilitating standards development and certification.

ANAB United States Verified

Kiwa BDA Testing

Building and construction product certification.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

EN 482:2012+A1:2015 is a standard published by the European Committee for Standardization (CEN). Its full title is "Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents". This standard covers: This European Standard specifies general requirements for the performance of procedures for the determination of the concentration of chemical agents in workplace atmospheres as required by the Chemical Agents Directive 98/24/EC (see reference [9]). The requirements given apply to all measuring procedures, irrespective of the physical form of the chemical agent (gas, vapour, airborne particles), the sampling method and the analytical method used. This European Standard is applicable to - all steps of a measuring procedure, - measuring procedures with separate sampling and analysis steps, and - direct-reading devices.

This European Standard specifies general requirements for the performance of procedures for the determination of the concentration of chemical agents in workplace atmospheres as required by the Chemical Agents Directive 98/24/EC (see reference [9]). The requirements given apply to all measuring procedures, irrespective of the physical form of the chemical agent (gas, vapour, airborne particles), the sampling method and the analytical method used. This European Standard is applicable to - all steps of a measuring procedure, - measuring procedures with separate sampling and analysis steps, and - direct-reading devices.

EN 482:2012+A1:2015 is classified under the following ICS (International Classification for Standards) categories: 13.040.30 - Workplace atmospheres. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 482:2012+A1:2015 has the following relationships with other standards: It is inter standard links to EN 482:2012/FprA1, EN 482:2012, EN 482:2021, EN 771-6:2000, EN 481:1993, EN 13205-1:2014. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 482:2012+A1:2015 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.PHULWHYExposition am Arbeitsplatz - Allgemeine Anforderungen an die Leistungsfähigkeit von Verfahren zur Messung chemischer ArbeitsstoffeExposition sur les lieux de travail - Exigences générales concernant les performances des procédures de mesure des agents chimiquesWorkplace exposure - General requirements for the performance of procedures for the measurement of chemical agents13.040.30Kakovost zraka na delovnem mestuWorkplace atmospheresICS:Ta slovenski standard je istoveten z:EN 482:2012+A1:2015SIST EN 482:2012+A1:2016en,fr,de01-januar-2016SIST EN 482:2012+A1:2016SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 482:2012+A1
October
t r s w ICS
s uä r v rä u r Supersedes EN
v z tã t r s tEnglish Version
Workplace exposure æ General requirements for the performance of procedures for the measurement of chemical agents Exposition sur les lieux de travail æ Exigences générales concernant les performances des procédures de mesure des agents chimiques
Exposition am Arbeitsplatz æ Allgemeine Anforderungen an die Leistungsfähigkeit von Verfahren zur Messung chemischer Arbeitsstoffe This European Standard was approved by CEN on
{ March
t r s t and includes Amendment
s approved by CEN on
s w August
t r s wä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey andUnited Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
t r s w CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
v z tã t r s t ªA sã t r s w ESIST EN 482:2012+A1:2016

Structure of a method description . 12 Annex B (informative)
Calculation of uncertainty of measurement. 13 B.1 General . 13 B.2 Uncertainty associated with sampled air volume or mass uptake . 14 B.2.1 Pumped sampling. 14 B.2.1.1 Sources of uncertainty . 14 B.2.1.2 Flow rate measurement . 14 B.2.1.3 Pump flow stability . 15 SIST EN 482:2012+A1:2016

5 min; for variation of concentration in space
¶ 15 min), c) measuring range that is fit for purpose (see 4.3), and d) expanded uncertainty that is fit for purpose (see 4.3). 5.4 Measurements for comparison with limit values and periodic measurements 5.4.1 Unambiguity A measuring procedure shall produce an unambiguous result for the concentration of the chemical agent being measured in the specified measuring range, i.e. an analytically determined value shall correspond to one concentration only. 5.4.2 Selectivity The measuring procedure shall contain appropriate information about the nature and magnitude of any interference. NOTE Selectivity requirements vary from case to case, depending on what is known in advance about the workplace air. If the identity of all contaminants present is not known in advance then the measuring procedure will need to have a high selectivity. If the identity of all contaminants is known prior to measurement and there are no interferents present, then it might be possible to use a measurement procedure with a low selectivity. Procedures for measuring chemical agents present as airborne particles shall prescribe a method for sampling the particle size fraction, as defined in EN 481, for which the limit value for the chemical agent is set. If different limit values are set for different species of a chemical agent, then the measuring procedure shall determine the individual species concerned. 5.4.3 Averaging time The averaging time is equal to the sampling time, which shall be less than or equal to the limit value reference period. SIST EN 482:2012+A1:2016

limit value
¶ 50 %
¶ 50 % long-term 0,1 times to < 0,5 times limit value
¶ 50 %
¶ 50 % long-term 0,5 times to 2 times limit value
¶ 30 %
¶ 50 % NOTE Variation of exposure to chemical agents in the workplace can be significantly greater than indicated by the uncertainty of a single measurement calculated according to this European Standard. This is due to the temporal and spatial variability of workplace exposure. ! 5.4.6 Chemical agents with low limit values In exceptional cases, the limit value of a chemical agent can be so low that at present no measuring procedure is available which meets the requirements given in 5.4.4 and 5.4.5. Until a measuring procedure which fulfils these requirements is available, a measuring procedure should be used whose performance is closest to the specified requirements. NOTE
A list of published measuring procedures is available from GESTIS Analytical methods database [11] which is updated regularly. These measuring procedures are rated according to their compliance with this European Standard and EN 838, EN 1076, EN 13890 and EN 13936." 5.5 Composite procedures The performance requirements detailed in 5.2, 5.3 and 5.4 shall be fulfilled for the whole measuring procedure even if the measuring procedure consists of several distinct steps, e.g. sampling, transport and storage, sample preparation and analysis. In the latter case, each step of the measuring procedure may be tested individually as an alternative to testing the measuring procedure as a whole. 5.6 Transport and storage Transport and storage of samples, if appropriate, shall be carried out in such a way that the physical and chemical integrity is maintained between sampling and analysis. SIST EN 482:2012+A1:2016
...