Fixed firefighting systems - Components for gas extinguishing systems - Part 10: Requirements and test methods for pressure gauges and pressure switches

This European Standard specifies requirements and describes test methods for pressure gauges and pressure switches. Pressure gauges are used e.g. for monitoring of pilot, control, alarm and storage containers of fire extinguishing systems filled with non-liquefied inert gases or pressurized halocarbon gases. Pressure switches are used e.g. for monitoring of pilot, control, alarm and storage containers of fire extinguishing systems filled with non-liquefied inert gases or pressurized halocarbon gases and remote indication of leakage.

Ortsfeste Brandbekämpfungsanlagen - Bauteile für Löschanlagen mit gasförmigen Löschmitteln - Teil 10: Anforderungen und Prüfverfahren für Druckmessgeräte und Druckschalter

Diese Europäische Norm legt Anforderungen und Prüfverfahren für Druckmessgeräte und Druckschalter fest.
Diese Europäische Norm gilt für Druckmessgeräte für die Überwachung von Pilot-, Steuer-, Alarm- und Löschmittelbehältern von Löschanlagen, die mit nichtverflüssigten Inertgasen oder druckbeaufschlagten halogenierten Kohlenwasserstoffen gefüllt sind.
Diese Europäische Norm gilt für Druckschalter für die Überwachung von Pilot-, Steuer-, Alarm- und Löschmittelbehältern von Löschanlagen, die mit nichtverflüssigten Inertgasen oder druckbeaufschlagten halogenierten Kohlenwasserstoffen gefüllt sind, und zur Weitermeldung von Schwund.
Diese Europäische Norm gilt nicht für Druckschalter zur Weitermeldung von Beginn oder Ende der Flutung.

Installations fixes de lutte contre l'incendie - Eléments constitutifs pour installations d'extinction à gaz - Partie 10: Exigences et méthodes d'essai pour manomètres et contacts à pression

La présente Norme européenne spécifie les exigences et décrit les méthodes d'essais applicables aux manomètres et aux manocontacts.
La présente Norme européenne s'applique aux manomètres utilisés pour la surveillance des réservoirs pilotes, de commande, d'alarme et de stockage des systèmes d'extinction d'incendie remplis de gaz inertes non liquéfiés ou de gaz inhibiteurs pressurisés.
La présente Norme européenne s'applique aux manocontacts utilisés pour la surveillance des réservoirs pilotes, de commande, d'alarme et de stockage des systèmes d'extinction d'incendie remplis de gaz inertes non liquéfiés ou de gaz inhibiteurs pressurisés et équipés de dispositifs de signalisation à distance des fuites.
La présente Norme européenne ne couvre pas les manocontacts indicateurs de décharge.

Vgrajeni gasilni sistemi – Sestavni deli sistemov za gašenje s plinom – 10. del: Zahteve in preskusne metode za merilnike tlaka in tlačna stikala

General Information

Status
Published
Publication Date
22-Apr-2003
Withdrawal Date
29-Apr-2006
Current Stage
9060 - Closure of 2 Year Review Enquiry - Review Enquiry
Start Date
02-Dec-2023
Completion Date
02-Dec-2023
Standard
EN 12094-10:2003
English language
19 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Ortsfeste Brandbekämpfungsanlagen - Bauteile für Löschanlagen mit gasförmigen Löschmitteln - Teil 10: Anforderungen und Prüfverfahren für Druckmessgeräte und DruckschalterInstallations fixes de lutte contre l'incendie - Eléments constitutifs pour installations d'extinction a gaz - Partie 10: Exigences et méthodes d'essai pour manometres et contacts a pressionFixed firefighting systems - Components for gas extinguishing systems - Part 10: Requirements and test methods for pressure gauges and pressure switches17.100Merjenje sile, teže in tlakaMeasurement of force, weight and pressure13.220.10Gašenje požaraFire-fightingICS:Ta slovenski standard je istoveten z:EN 12094-10:2003SIST EN 12094-10:2003en01-september-2003SIST EN 12094-10:2003SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 12094-10April 2003ICS 13.220.20English versionFixed firefighting systems - Components for gas extinguishingsystems - Part 10: Requirements and test methods for pressuregauges and pressure switchesInstallations fixes de lutte contre l'incendie - Elémentsconstitutifs pour installations d'extinction à gaz - Partie 10:Exigences et méthodes d'essai pour manomètres etcontacts à pressionOrtsfeste Brandbekämpfungsanlagen - Bauteile fürLöschanlagen mit gasförmigen Löschmitteln - Teil 10:Anforderungen und Prüfverfahren für Druckmessgeräte undDruckschalterThis European Standard was approved by CEN on 13 February 2003.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and UnitedKingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2003 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 12094-10:2003 ESIST EN 12094-10:2003

Clauses of this European Standard addressing the provisions of the EUConstruction Products Directive.15Bibliography.19SIST EN 12094-10:2003

1)under preparationSIST EN 12094-10:2003

and testsNOTESee 5.1.3 and EN 837-1.5.1.2 Compliance and conformityA visual and measurement check shall be made with one sample to determine that the component corresponds to thedescription in the drawings, parts lists, description of functions, operating and installation instructions.5.1.3 CorrosionOne sample shall be conditioned in accordance with 5.2.8 followed by an accuracy check in accordance withEN 837-1.SIST EN 12094-10:2003

C and (++5002) °C after conditioning at the testtemperature for (2 ± 0,5) h.5.2.8 CorrosionA specimen shall be suspended freely in its normal installation attitude.The test set-up comprises a container 5 l in volume, made of heat-resistant glass and with a corrosion-resistantcover which is shaped to prevent condensate dripping onto the specimen. (If a container 10 l in volume is used, thequantities of chemicals given below shall be doubled.) The container is heated electrically and the side walls arecooled with water. A thermostat regulates the heating so as to maintain a temperature of approximately 45 °Cinside the container. During testing water is passed through a cooling coil wrapped around the container, it shallflow fast enough that its temperature at the discharge point is below 30 °C.The combination of heating and cooling is designed to ensure that vapours will condense on the surface of thespecimen. The sulphur dioxide atmosphere is generated in the 5-litre container with a solution of 20 g of sodiumthiosulphate (Na2S2O3 x 5H2O) in 500 cm3 of distilled water, to which 20 cm3 of dilute sulphuric acid is addeddaily. The dilute sulphuric acid comprises 128 cm3 of one molar sulphuric acid (H2SO4) dissolved in 1 l of distilledwater. The test specimen shall be removed from the container after 8 days; the container shall be cleaned. Thenthe procedure described above is repeated for a further period of 8 days.After a total of 16 days, the specimen is removed from the container and allowed to dry for seven days at atemperature of (20 ± 5) °C at maximum relative humidity of 70 %.6 MarkingPressure gauges shall be marked in accordance with EN 837-1:1996, 9.6.7.Pressure switches shall be marked with:a) name or trademark of the manufacturer or supplier;b) model designation (type);c) some mark(s) or code(s) (e.g. serial number or batch code), by which, at least, the date or batch and place ofmanufacture (if several places of manufacture) can be identified by the manufacturer; andd) set-point pressure.The markings shall be non-detachable, non-flammable, permanent and legible.Where the requirements of ZA.3 give the same information as above, the requirements of this clause 6 have beenmet.SIST EN 12094-10:2003
...