Standard Practice for Use of Qualitative Chemical Spot Test Kits for Detection of Lead in Dry Paint Films

SIGNIFICANCE AND USE
5.1 This technique is applicable to dry paint films and varnishes in a variety of forms including the intact dry paint film surface, a notched or other angular cut surface that exposes a cross section of all paint layers, a paint chip, and ground paint film.  
5.2 The response of the spot test method varies depending on the extractability of lead from a coating matrix, which may differ depending on the test kit used, the coating type tested, and the type of lead pigment (3).  
5.3 In some situations, metals and other chemical species interfere with the spot tests causing false negative or false positive results (see Section 8).  
5.4 A spot test result may be used as a negative screen for the presence of lead in paints and varnishes provided the response of the test kit is sensitive to detecting lead reliably at a given predetermined level, for example, a regulatory action level (4).  
5.5 This practice may be used in conjunction with quantitative and semi-quantitative analytical methods for lead such as anodic stripping voltammetry or spectroscopic laboratory analysis of paint chip samples, or portable X-ray fluorescence testing of in situ paint films.  
5.6 Colorblind individuals (protanomalous viewers) who are deficient in viewing red colors may have difficulty in discerning the pink or red color of a positive rhodizonate test.
SCOPE
1.1 This practice covers the use of commercial spot test kits based on either sulfide or rhodizonate for the qualitative determination of the presence of lead in dry paint films.  
1.2 This practice may also be used as a qualitative procedure for other dry coating films such as varnishes.  
1.3 This practice provides a list of the advantages and limitations of chemical spot test kits based on sulfide and rhodizonate to allow the user to choose the appropriate spot test for a given circumstance.  
1.4 This practice contains notes which are explanatory and not part of mandatory requirements.  
1.5 Methods described in this practice may not meet or be allowed by requirements or regulations established by local authorities having jurisdiction. It is the responsibility of the user of this standard to comply with all such requirements and regulations.  
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Oct-2022
Technical Committee
D22 - Air Quality

Relations

Effective Date
01-Sep-2020
Effective Date
15-Mar-2020
Effective Date
15-Dec-2018
Effective Date
01-Oct-2018
Effective Date
01-Sep-2018
Effective Date
15-Oct-2015
Effective Date
01-Jul-2015
Effective Date
01-Dec-2014
Effective Date
01-May-2014
Effective Date
15-Jan-2014
Effective Date
15-Jul-2012
Effective Date
01-Apr-2010
Effective Date
01-May-2005
Effective Date
01-Nov-2004
Effective Date
01-Dec-2003

Overview

ASTM E1753-22 is the recognized standard practice for the use of qualitative chemical spot test kits to detect lead in dry paint films. Developed by ASTM International, this standard offers comprehensive guidelines for using commercial spot test kits based on sulfide or rhodizonate chemistries for qualitative determination of lead presence in paints and varnishes. The standard helps users choose appropriate test methods, highlights safety and regulatory considerations, and ensures consistent, reliable detection of lead in building materials.

Key Topics

  • Qualitative Spot Test Kits: The standard details the procedures for using sulfide and rhodizonate-based spot test kits. Both methods are based on detectable color changes when lead is present, making rapid, on-site assessment possible.
  • Applicability: Methods can be used on intact surfaces, notched or cut surfaces exposing all paint layers, paint chips, or ground paint films. The practice also extends to other dry coating films such as varnishes.
  • Test Kit Selection: Users are provided with information about advantages and limitations of both types of kits to facilitate appropriate choice:
    • Sulfide Tests: Fast and easy, with grey/black color change, but may have non-specific reactions and hazards associated with hydrogen sulfide gas.
    • Rhodizonate Tests: More specific for lead and produce a pink/red color but may be limited by color interference and shelf life of reagents.
  • Interferences: Other metals or chemical species in paints may impact test accuracy, causing false positives or negatives. The standard outlines methods to help identify and mitigate these challenges.
  • Performance as Screening Tools: Spot tests are best used as negative screens to rule out the presence of lead when test sensitivity is sufficient for regulatory thresholds.
  • Health and Safety: The standard stresses proper handling, storage, and disposal of reagents, as well as the use of gloves and eye protection when applicable.

Applications

ASTM E1753-22 is valuable for professionals involved in lead hazard assessment, abatement, and compliance:

  • Lead Hazard Assessment: Building inspectors, environmental consultants, and abatement contractors use the standard to rapidly screen for the presence of lead in paints during surveys or prior to renovation.
  • Residential and Commercial Properties: Ensures compliance with local, state, or federal regulations, especially in pre-1978 buildings or facilities where lead-based paints were commonly used.
  • Industrial and Marine Settings: Applicable for identifying lead-containing paints, especially those with lead chromate pigments.
  • Support for Laboratory Analysis: Spot test results may prompt more detailed quantitative or semi-quantitative analyses using portable X-ray fluorescence (XRF), anodic stripping voltammetry, or laboratory paint chip analysis.

Related Standards

  • ASTM D1356: Terminology Relating to Sampling and Analysis of Atmospheres
  • ASTM E1605: Terminology Relating to Lead in Buildings
  • Other Related Methods: Portable XRF testing, laboratory spectroscopic methods, and standardized quality control practices for chemical test kits

Keywords: ASTM E1753-22, lead detection, paint testing, spot test kits, sulfide test, rhodizonate test, qualitative analysis, lead in paint, building inspection, lead abatement, hazard assessment.

Buy Documents

Standard

ASTM E1753-22 - Standard Practice for Use of Qualitative Chemical Spot Test Kits for Detection of Lead in Dry Paint Films

English language (5 pages)
sale 15% off
sale 15% off
Standard

REDLINE ASTM E1753-22 - Standard Practice for Use of Qualitative Chemical Spot Test Kits for Detection of Lead in Dry Paint Films

English language (5 pages)
sale 15% off
sale 15% off

Frequently Asked Questions

ASTM E1753-22 is a standard published by ASTM International. Its full title is "Standard Practice for Use of Qualitative Chemical Spot Test Kits for Detection of Lead in Dry Paint Films". This standard covers: SIGNIFICANCE AND USE 5.1 This technique is applicable to dry paint films and varnishes in a variety of forms including the intact dry paint film surface, a notched or other angular cut surface that exposes a cross section of all paint layers, a paint chip, and ground paint film. 5.2 The response of the spot test method varies depending on the extractability of lead from a coating matrix, which may differ depending on the test kit used, the coating type tested, and the type of lead pigment (3). 5.3 In some situations, metals and other chemical species interfere with the spot tests causing false negative or false positive results (see Section 8). 5.4 A spot test result may be used as a negative screen for the presence of lead in paints and varnishes provided the response of the test kit is sensitive to detecting lead reliably at a given predetermined level, for example, a regulatory action level (4). 5.5 This practice may be used in conjunction with quantitative and semi-quantitative analytical methods for lead such as anodic stripping voltammetry or spectroscopic laboratory analysis of paint chip samples, or portable X-ray fluorescence testing of in situ paint films. 5.6 Colorblind individuals (protanomalous viewers) who are deficient in viewing red colors may have difficulty in discerning the pink or red color of a positive rhodizonate test. SCOPE 1.1 This practice covers the use of commercial spot test kits based on either sulfide or rhodizonate for the qualitative determination of the presence of lead in dry paint films. 1.2 This practice may also be used as a qualitative procedure for other dry coating films such as varnishes. 1.3 This practice provides a list of the advantages and limitations of chemical spot test kits based on sulfide and rhodizonate to allow the user to choose the appropriate spot test for a given circumstance. 1.4 This practice contains notes which are explanatory and not part of mandatory requirements. 1.5 Methods described in this practice may not meet or be allowed by requirements or regulations established by local authorities having jurisdiction. It is the responsibility of the user of this standard to comply with all such requirements and regulations. 1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

SIGNIFICANCE AND USE 5.1 This technique is applicable to dry paint films and varnishes in a variety of forms including the intact dry paint film surface, a notched or other angular cut surface that exposes a cross section of all paint layers, a paint chip, and ground paint film. 5.2 The response of the spot test method varies depending on the extractability of lead from a coating matrix, which may differ depending on the test kit used, the coating type tested, and the type of lead pigment (3). 5.3 In some situations, metals and other chemical species interfere with the spot tests causing false negative or false positive results (see Section 8). 5.4 A spot test result may be used as a negative screen for the presence of lead in paints and varnishes provided the response of the test kit is sensitive to detecting lead reliably at a given predetermined level, for example, a regulatory action level (4). 5.5 This practice may be used in conjunction with quantitative and semi-quantitative analytical methods for lead such as anodic stripping voltammetry or spectroscopic laboratory analysis of paint chip samples, or portable X-ray fluorescence testing of in situ paint films. 5.6 Colorblind individuals (protanomalous viewers) who are deficient in viewing red colors may have difficulty in discerning the pink or red color of a positive rhodizonate test. SCOPE 1.1 This practice covers the use of commercial spot test kits based on either sulfide or rhodizonate for the qualitative determination of the presence of lead in dry paint films. 1.2 This practice may also be used as a qualitative procedure for other dry coating films such as varnishes. 1.3 This practice provides a list of the advantages and limitations of chemical spot test kits based on sulfide and rhodizonate to allow the user to choose the appropriate spot test for a given circumstance. 1.4 This practice contains notes which are explanatory and not part of mandatory requirements. 1.5 Methods described in this practice may not meet or be allowed by requirements or regulations established by local authorities having jurisdiction. It is the responsibility of the user of this standard to comply with all such requirements and regulations. 1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM E1753-22 is classified under the following ICS (International Classification for Standards) categories: 87.040 - Paints and varnishes. The ICS classification helps identify the subject area and facilitates finding related standards.

ASTM E1753-22 has the following relationships with other standards: It is inter standard links to ASTM D1356-20a, ASTM D1356-20, ASTM E1605-18b, ASTM E1605-18a, ASTM E1605-18, ASTM D1356-15a, ASTM D1356-15, ASTM D1356-14b, ASTM D1356-14a, ASTM D1356-14, ASTM E1605-04(2012), ASTM D1356-05(2010), ASTM D1356-05, ASTM E1605-04, ASTM E1605-03e1. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ASTM E1753-22 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E1753 − 22
Standard Practice for
Use of Qualitative Chemical Spot Test Kits for Detection of
Lead in Dry Paint Films
This standard is issued under the fixed designation E1753; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2.1 ASTM Standards:
1.1 Thispracticecoverstheuseofcommercialspottestkits
D1356Terminology Relating to Sampling and Analysis of
based on either sulfide or rhodizonate for the qualitative
Atmospheres
determination of the presence of lead in dry paint films.
E1605Terminology Relating to Lead in Buildings
1.2 This practice may also be used as a qualitative proce-
dure for other dry coating films such as varnishes. 3. Terminology
3.1 For definitions of terms relating to this practice that do
1.3 This practice provides a list of the advantages and
not appear here, refer to Terminologies D1356 and E1605.
limitations of chemical spot test kits based on sulfide and
rhodizonatetoallowtheusertochoosetheappropriatespottest
3.2 Definitions of Terms Specific to This Standard:
for a given circumstance. 3.2.1 core sample—a fragment of the entire dry paint film
removed from the substrate with a coring tool which is
1.4 This practice contains notes which are explanatory and
designed to remove a specified area (for example, a square
not part of mandatory requirements.
centimetre) of dry paint film.
1.5 Methods described in this practice may not meet or be
3.2.2 negative screen—a spot test for which a negative
allowed by requirements or regulations established by local
result indicates a low probability of lead being present in the
authorities having jurisdiction. It is the responsibility of the
test specimen above a predetermined level; for example, a
user of this standard to comply with all such requirements and regulatory action level.
regulations.
3.2.3 negative test—the absence of the characteristic color
change within a specified time limit, usually within a few
1.6 The values stated in SI units are to be regarded as
minutes.
standard. No other units of measurement are included in this
3.2.4 paint chip sample—a fragment of a dry paint film
standard.
removed from the substrate.
1.7 This standard does not purport to address all of the
3.2.5 positive test—the observation of the characteristic
safety concerns, if any, associated with its use. It is the
colorchangewithinaspecifiedtimelimit,usuallywithinafew
responsibility of the user of this standard to establish appro-
minutes,althoughspecificproceduresforsometestkitsinclude
priate safety, health, and environmental practices and deter-
observing the characteristic color change after an overnight
mine the applicability of regulatory limitations prior to use.
waiting period.
1.8 This international standard was developed in accor-
3.2.6 rhodizonate spot test method—for lead detection, the
dance with internationally recognized principles on standard-
use of a dilute solution of rhodizonate ion to test a painted
ization established in the Decision on Principles for the
surface or paint chip for the qualitative presence of lead (1).
Development of International Standards, Guides and Recom-
3.2.6.1 Discussion—A characteristic color change of the
mendations issued by the World Trade Organization Technical
reagent from yellow/orange to pink or red indicates the
Barriers to Trade (TBT) Committee.
presence of lead above the level of detection of the test kit.
1 2
ThispracticeisunderthejurisdictionofASTMCommitteeD22onAirQuality For referenced ASTM standards, visit the ASTM website, www.astm.org, or
and is the direct responsibility of Subcommittee D22.12 on Sampling andAnalysis contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
of Lead for Exposure and Risk Assessment. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Nov. 1, 2022. Published November 2022. Originally the ASTM website.
approved in 1995. Last previous edition approved in 2019 as E1753–19. DOI: The boldface numbers in parentheses refer to a list of references at the end of
10.1520/E1753-22. this practice.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
E1753 − 22
3.2.7 sulfide spot test method—for lead detection,theuseof 6.1.1 Sulfide Based Spot Test Kit (usually consists of a 5%
a dilute solution of sulfide ion to test a painted surface or paint to 8% solution of sodium sulfide in a dropper bottle).
chip for the qualitative presence of lead (2). 6.1.2 Disposable Plastic or Latex Gloves.
3.2.7.1 Discussion—A characteristic color change of the
6.2 For Rhodizonate Spot Tests:
reagent from colorless to grey or black indicates the presence
6.2.1 Rhodizonate Based Spot Test Kit (usually consists of
of lead above the level of detection of the spot test.
rhodizonate reagent and an acid extraction solution).
6.2.2 Absorbent Applicators, (that is, swabs, filter papers)
4. Summary of Practice
for applying spot test reagents or for extracting and collecting
4.1 A dry paint film sample (a painted surface, paint chip, the lead from the painted surface, which may or may not be
ground paint powder, or core sample) is tested for lead provided with a purchased test kit.
qualitatively through the use of a spot test. Spot tests kits are
6.3 For Both Sulfide and Rhodizonate Spot Tests:
2+
based on the reaction of Lead II (Pb ) ion with either sulfide
6.3.1 Non-Abrasive Cleaning Solution.
2− 2−
ion (S ) or rhodizonate ion [C O ], resulting in the charac-
6 6
6.3.2 Towels, Towelette, or Sponge.
teristic color change (See 3.2.6 and 3.2.7).
6.3.3 Cutting Tool, used to cut into the dry paint film. A
4.1.1 Prior to performing the spot test, the dry paint film
cutting tool may or may not be provided with the kit.
surfaceisfirstcleaned.Exceptforsurfacetests,thefilmisthen
Acceptable cutting tools include a clean cutting knife with a
prepared by either cutting a notch or an angular cut in situ or
fine, sharp edge, razor knife, thin scalpel blade, or coring tool.
by removing a paint chip or core sample.
6.3.4 Mortar and Pestle, for grinding paint chip sample, if
4.1.2 The test is performed by applying the spot test
necessary.
reagents(directlyorwiththeuseofanadsorbentapplicator)to
6.3.5 Magnifying Glass (at least 4× power).
the prepared dry paint sample and observing the characteristic
6.3.6 Flashlight, to examine color change under incandes-
color change after a specified time, usually within a few
cent white light in dimly lit areas.
minutes.
7. Reagents
4.1.3 Aninterpretationofthepresenceorabsenceofleadin
the dry paint sample is made based on the observation of the
7.1 Reagents as Provided by the Spot Test Kit—Reagents
presence or absence of the characteristic color change.
and materials kept beyond the preparer’s expiration date or
recommended shelf life shall be discarded. Store spot test kits
5. Significance and Use
at room temperature away from direct sunlight or room light.
Freshly prepared rhodizonate reagents require storage in a
5.1 This technique is applicable to dry paint films and
refrigerator to retard the rate of hydrolysis of the rhodizonate
varnishes in a variety of forms including the intact dry paint
dye.
film surface, a notched or other angular cut surface that
exposes a cross section of all paint layers, a paint chip, and
7.2 Dispose of reagents according to applicable regulations
ground paint film.
promulgated by authorities having jurisdiction.
5.2 The response of the spot test method varies depending
8. Advantages and Disadvantages of Different Chemical
on the extractability of lead from a coating matrix, which may
Spot Tests
differ depending on the test kit used, the coating type tested,
8.1 Sulfide Test—A clear solution of sodium sulfide reacts
and the type of lead pigment (3).
with lead in situ or on paint chips to produce a grey or black
5.3 In some situations, metals and other chemical species
color (lead sulfide, PbS).
interfere with the spot tests causing false negative or false
8.1.1 Sulfide Test Advantages:
positive results (see Section 8).
8.1.1.1 Sulfide-based tests are rapid, easy, and relatively
5.4 A spot test result may be used as a negative screen for
inexpensive to use.
the presence of lead in paints and varnishes provided the
8.1.1.2 Sodium sulfide reacts with most lead containing
response of the test kit is sensitive to detecting lead reliably at
pigments in paint, including lead chromate pigments, within 2
a given predetermined level, for example, a regulatory action
min.
level (4). 8.1.2 Sulfide Test Disadvantages:
8.1.2.1 Sulfide solutions emit a toxic, potentially hazardous
5.5 This practice may be used in conjunction with quanti-
gas (H S) which has an unpleasant odor (rotten eggs). The
tativeandsemi-quantitativeanalyticalmethodsforleadsuchas
generationofhazardouslevelsofH Sinthefield,however,can
anodic stripping voltammetry or spectroscopic laboratory
beminimizedbygoodventilation,byusinglowconcentrations
analysis of paint chip samples, or portable X-ray fluorescence
ofsodiumsulfide(nottoexceed5%to8%),byrestrictingthe
testing of in situ paint films.
volume of sodium sulfide solution used per test to a drop, and
5.6 Colorblind individuals (protanomalous viewers) who
by carrying only small amounts of sodium sulfide solutions
are deficient in viewing red colors may have difficulty in
(30mLorless).Also,sinceacidconditionsincreasetherelease
discerning the pink or red color of a positive rhodizonate test.
of H S gas, do not use a strong acid or an acidic solution to
clean the test location either before or after the sulfide test is
6. Apparatus and Materials
performed. The user is cautioned to minimize breathing in the
6.1 For Sulfide Spot Tests: H S fumes. In addition, since sulfide solutions are alkaline, it
E1753 − 22
is recommended that the user consider wearing gloves and eye 8.2 Rhodizonate Test—A yellow/orange solution of rhodi-
protection. Sulfide solutions are poisonous and are to be kept zonate reacts with lead to produce a pink or red complex
out of the reach of children. (PbC O ) under acid conditions.
6 6
8.2.1 Rhodizonate Test Advantages:
8.1.2.2 Sulfide based tests are not specific for lead. In
additiontolead,sulfideionreactswithseveralothermetalions 8.2.1.1 Rhodizonate is more specific for lead in paint than
sulfide. Under acid conditions, only lead reacts with the
to give a black color including iron, nickel, cobalt, copper,
mercury, and molybdenum (1, 5). Except for iron, the concen- yellow/orange rhodizonate solution to give a pink to red color
(1, 6).
tration of these metals in paint is usually less than 1%, which
is too low to be detected by a 5% to 8% solution of sodium
NOTE 2—If the pH of the rhodizonate reagent is neutral or basic, the
sulfide (2). Iron-containing pigments, oxides, and iron blue are
characteristic color change for lead is from yellow/orange to blue or
found in paints. Oxides are used primarily in exterior paints to
violet.However,underneutralorbasicconditions,theblueorvioletcolor
provide deep earth-toned colors. Although sodium sulfide change is not specific for lead (1, 6).
solution does not cause a color change with all iron oxide
8.2.1.2 Rhodizonate based tests are rapid, easy, and rela-
pigments, positive sulfide spot test results on deep earth-toned
tively inexpensive to use.
or blue colored paints are to be considered suspect. In these
8.2.2 Rhodizonate Disadvantages:
cases,theuseofothertestproceduresforleadisrecommended.
8.2.2.1 Rhodizonatebasedspottestsshallnotbeusedonred
8.1.2.3 Testingpaintdirectlyonmetalsurfacescomposedof
or pink paint that rubs off or bleeds color. However, rhodizon-
iron, copper, or nickel (for example, pipes and radiators) is
ate based spot tests that use absorbent applicators to apply the
discouraged as it may lead to false positive results. An
test reagents may be used on red or pink paint that does not
immediate dark color is formed on the surface of some treated
bleed color.
steels, for example, phosphate treatment.
NOTE 3—It may be determined if red or pink paint does bleed by
8.1.2.4 Metals other than lead and iron found in large
dippingacottonswabintotheleachingsolutionsuppliedbythetestkitor,
quantitiesinpaintincludezinc,titanium,andbarium,butnone
if none is provided, dipping a cotton swab into household vinegar and
of these metals produces a black color with sulfide (2). Zinc
rubbing the cotton swab over the surface of the red or pink paint. If a red
or pink color is observed on the cotton swab, rhodizonate based tests
sulfidesarecolorless;titaniumsulfidescanberedorevengrey,
should not be used to test these painted surfaces. Instead, it is recom-
and barium sulfides are yellow/green (1). However, these
mended that a sodium sulfide spot test or other acceptable test method be
sulfides are rarely observed when testing paint with sodium
used to determine the presence of lead.
sulfide spot tests because of the low solubility of the metal
8.2.2.2 Rhodizonate ion will react with barium ion to form
species in the sodium sulfide solution.
an orange color. Barium sulfate was sometimes added to
8.1.2.5 Sulfide can react with some non-lead containing
householdpaintsasanextender,butbecauseoftheinsolubility
paints used today to produce a grey color; however, most
of barium sulfate, barium ion and, hence, the orange color, is
non-lead containing paints do not react with the 5% to 8%
only rarely detected. However, since it is possible for a strong
solutions of sodium sulfide to give a grey color.
orange color to mask a weak pink color due to lead, it is
8.1.2.6 It is difficult to discern a black color against dark
recommended that paints providing an orange color with
paints such as black, brown, dark green, or dark blue. For dark
rhodizonate be further tested with a sodium sulfide test kit or
paints other than black, the use of a magnifying glass, white
other acceptable lead detection method (for example, labora-
tissue, or commercial cotton swab to take up the black color
tory analysis of a paint chip sample).
mayaidinthedeterminationofthetestresult.Resultsobserved
NOTE 4—A rhodizonate test can be performed at a notched or angular
at the te
...


This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E1753 − 19 E1753 − 22
Standard Practice for
Use of Qualitative Chemical Spot Test Kits for Detection of
Lead in Dry Paint Films
This standard is issued under the fixed designation E1753; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This practice covers the use of commercial spot test kits based on either sulfide or rhodizonate for the qualitative determination
of the presence of lead in dry paint films.
1.2 This practice may also be used as a qualitative procedure for other dry coating films such as varnishes.
1.3 This practice provides a list of the advantages and limitations of chemical spot test kits based on sulfide and rhodizonate to
allow the user to choose the appropriate spot test for a given circumstance.
1.4 This practice contains notes which are explanatory and not part of mandatory requirements.
1.5 Methods described in this practice may not meet or be allowed by requirements or regulations established by local authorities
having jurisdiction. It is the responsibility of the user of this standard to comply with all such requirements and regulations.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2.1 ASTM Standards:
D1356 Terminology Relating to Sampling and Analysis of Atmospheres
E1605 Terminology Relating to Lead in Buildings
This practice is under the jurisdiction of ASTM Committee D22 on Air Quality and is the direct responsibility of Subcommittee D22.12 on Sampling and
Analysis,Analysis of Lead,Lead for Exposure and Risk Assessment.
Current edition approved Jan. 1, 2019Nov. 1, 2022. Published February 2019November 2022. Originally approved in 1995. Last previous edition approved in 20182019
as E1753–18a.–19. DOI: 10.1520/E1753–19.10.1520/E1753-22.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
E1753 − 22
3. Terminology
3.1 For definitions of terms relating to this practice that do not appear here, refer to TerminologyTerminologies D1356 and E1605.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 core sample—a fragment of the entire dry paint film removed from the substrate with a coring tool which is designed to
remove a specified area (for example, a square centimetre) of dry paint film.
3.2.2 negative screen—a spot test for which a negative result indicates a low probability of lead being present in the test specimen
above a predetermined level; for example, a regulated federal or state abatement regulatory action level.
3.2.3 negative test—the absence of the characteristic color change within a specified time limit, usually within a few minutes.
3.2.4 paint chip sample—a fragment of a dry paint film removed from the substrate.
3.2.5 positive test—the observation of the characteristic color change within a specified time limit, usually within a few minutes,
although specific procedures for some test kits include observing the characteristic color change after an overnight waiting period.
3.2.6 rhodizonate spot test method—for lead detection, the use of a dilute solution of rhodizonate ion to test a painted surface or
paint chip for the qualitative presence of lead (1).
3.2.6.1 Discussion—
A characteristic color change of the reagent from yellow/orange to pink or red indicates the presence of lead above the level of
detection of the test kit.
3.2.7 sulfide spot test method—for lead detection, the use of a dilute solution of sulfide ion to test a painted surface or paint chip
for the qualitative presence of lead (2).
3.2.7.1 Discussion—
A characteristic color change of the reagent from colorless to grey or black indicates the presence of lead above the level of
detection of the spot test.
4. Summary of Practice
4.1 A dry paint film sample (a painted surface, paint chip, ground paint powder, or core sample) is tested for lead qualitatively
2+ 2−
through the use of a spot test. Spot tests kits are based on the reaction of Lead II (Pb ) ion with either sulfide ion (S ) or
2−
rhodizonate ion [C O ], resulting in the characteristic color change (See 3.2.6 and 3.2.7).
6 6
4.1.1 Prior to performing the spot test, the dry paint film surface is first cleaned. Except for surface tests, the film is then prepared
by either cutting a notch or an angular cut in situ or by removing a paint chip or core sample.
4.1.2 The test is performed by applying the spot test reagents (directly or with the use of an adsorbent applicator) to the prepared
dry paint sample and observing the characteristic color change after a specified time, usually within a few minutes.
4.1.3 An interpretation of the presence or absence of lead in the dry paint sample is made based on the observation of the presence
or absence of the characteristic color change.
5. Significance and Use
5.1 This technique is applicable to dry paint films and varnishes in a variety of forms including the intact dry paint film surface,
a notched or other angular cut surface that exposes a cross section of all paint layers, a paint chip, and ground paint film.
5.2 The response of the spot test method varies depending on the extractability of lead from a coating matrix, which may differ
depending on the test kit used, the coating type tested, and the type of lead pigment (3).
The boldface numbers in parentheses refer to a list of references at the end of this practice.
E1753 − 22
5.3 In some situations, metals and other chemical species interfere with the spot tests causing false negative or false positive
results (see Section 8).
5.4 A spot test result may be used as a negative screen for the presence of lead in paints and varnishes provided the response of
the test kit is sensitive to detecting lead reliably at a given predetermined level, for example, a federal or state regulated abatement
regulatory action level (4).
5.5 This practice may be used in conjunction with quantitative and semi-quantitative analytical methods for lead such as portable
X-ray fluorescence, anodic stripping voltammetry,voltammetry or fixed-sitespectroscopic laboratory analysis of paint chip
samples.samples, or portable X-ray fluorescence testing of in situ paint films.
5.6 Colorblind individuals (protanomalous viewers) who are deficient in viewing red colors may have difficulty in discerning the
pink or red color of a positive rhodizonate test.
6. Apparatus and Materials
6.1 For Sulfide Spot Tests:
6.1.1 Sulfide Based Spot Test Kit (usually consists of a 55 % to 8 % solution of sodium sulfide in a dropper bottle).
6.1.2 Disposable Plastic or Latex Gloves.
6.2 For Rhodizonate Spot Tests:
6.2.1 Rhodizonate Based Spot Test Kit (usually consists of rhodizonate reagent and an acid extraction solution).
6.2.2 Absorbent Applicators, (that is, swabs, filter papers) for applying spot test reagents or for extracting and collecting the lead
from the painted surface. Absorbent applicators (that is, swabs, filter paper) surface, which may or may not be provided with a
purchased test kit.
6.3 For Both Sulfide and Rhodizonate Spot Tests:
6.3.1 Non-Abrasive Cleaning Solution.
6.3.2 Towels, Towelette, or Sponge.
6.3.3 Cutting Tool, used to cut into the dry paint film. A cutting tool may or may not be provided with the kit. Acceptable cutting
tools include a clean cutting knife with a fine, sharp edge, razor knife, thin scalpel blade, or coring tool.
6.3.4 Mortar and Pestle, for grinding paint chip sample, if necessary.
6.3.5 Magnifying Glass (at least 4× power).
6.3.6 Flashlight, to examine color change under incandescent white light in dimly lit areas.
7. Reagents
7.1 Reagents as Provided by the Spot Test Kit—Reagents and materials kept beyond the preparer’s expiration date or
recommended shelf life shall be discarded. Store spot test kits at room temperature away from direct sunlight or room light. Freshly
prepared rhodizonate reagents require storage in a refrigerator to retard the rate of hydrolysis of the rhodizonate dye.
7.2 Dispose of reagents according to applicable regulations promulgated by authorities having jurisdiction.
E1753 − 22
8. Advantages and Disadvantages of Different Chemical Spot Tests
8.1 Sulfide Test—A clear solution of sodium sulfide reacts with lead in situ or on paint chips to produce a grey or black color (lead
sulfide, PbS).
8.1.1 Sulfide Test Advantages:
8.1.1.1 Sulfide-based tests are rapid, easy, and relatively inexpensive to use.
8.1.1.2 Sodium sulfide reacts with most lead containing pigments in paint, including lead chromate pigments, within 1 or 2 min.
8.1.2 Sulfide Test Disadvantages:
8.1.2.1 Sulfide solutions emit a toxic, potentially hazardous gas (H S) which has an unpleasant odor (rotten eggs). The generation
of hazardous levels of H S in the field, however, can be minimized by good ventilation, by using low concentrations of sodium
sulfide (not to exceed 55 % to 8 %), by restricting the volume of sodium sulfide solution used per test to a drop, and by carrying
only small amounts of sodium sulfide solutions (30 mL or less). Also, since acid conditions increase the release of H S gas, do
not use a strong acid or an acidic solution to clean the test location either before or after the sulfide test is performed. The user
is cautioned to minimize breathing in the H S fumes. In addition, since sulfide solutions are alkaline, it is recommended that the
user consider wearing gloves and eye protection. Sulfide solutions are poisonous and are to be kept out of the reach of children.
8.1.2.2 Sulfide based tests are not specific for lead. In addition to lead, sulfide ion reacts with several other metal ions to give a
black color including iron, nickel, cobalt, copper, mercury, and molybdenum (1, 5). Except for iron, the concentration of these
metals in paint is usually less than 1 %, which is too low to be detected by a 55 % to 8 % solution of sodium sulfide (2).
Iron-containing pigments, oxides, and iron blue are found in paints. Oxides are used primarily in exterior paints to provide deep
earth-toned colors. Although sodium sulfide solution does not cause a color change with all iron oxide pigments, positive sulfide
spot test results on deep earth-toned or blue colored paints are to be considered suspect. In these cases, the use of other test
procedures for lead is recommended.
8.1.2.3 Testing paint directly on metal surfaces composed of iron, copper, or nickel (for example, pipes and radiators) is
discouraged as it may lead to false positive results. An immediate dark color is formed on the surface of some treated steels, for
example, phosphate treatment.
8.1.2.4 Metals other than lead and iron found in large quantities in paint include zinc, titanium, and barium, but none of these
metals produces a black color with sulfide (2). Zinc sulfides are colorless; titanium sulfides can be red or even grey, and barium
sulfides are yellow/green (1). However, these sulfides are rarely observed when testing paint with sodium sulfide spot tests because
of the low solubility of the metal species in the sodium sulfide solution.
8.1.2.5 Sulfide can react with some non-lead containing paints used today to produce a grey color; however, most non-lead
containing paints do not react with the 55 % to 8 % solutions of sodium sulfide to give a grey color.
8.1.2.6 It is difficult to discern a black color against dark paints such as black, brown, dark green, or dark blue. For dark paints
other than black, the use of a magnifying glass, white tissue, or commercial cotton swab to take up the black color may aid in the
determination of the test result. Results observed at the test location shall be compared to a similarly prepared control test location
prepared a few centimetres away from the test location and wetted with water. If there is no difference in appearance between the
control test location and the test location, the test result is considered negative. Alternatively, for black paint and other dark colored
paints, the use of a rhodizonate based test kit that uses absorbent applicators or other acceptable procedures is recommended.
8.1.2.7 Once exposed to air, 55 % to 8 % solutions of sodium sulfide have a limited shelf life. Do not use sodium sulfide solutions
beyond their expiration date.
NOTE 1—Shelf life depends upon storage, temperature, light conditions, and other use factors.
8.1.2.8 If a sulfide spot test that is first conducted on a notch cut into the test surface yields a negative results, re-conduct the test
on a chip removed from the surface. Research has indicated that some sulfide test kits have increased sensitivity when used on a
chip removed from the surface than on a notch cut into the surface (4).
E1753 − 22
8.2 Rhodizonate Test—A yellow/orange solution of rhodizonate reacts with lead to produce a pink or red complex (PbC O ) under
6 6
acid conditions.
8.2.1 Rhodizonate Test Advantages:
8.2.1.1 Rhodizonate is more specific for lead in paint than sulfide. Under acid conditions, only lead reacts with the yellow/orange
rhodizonate solution to give a pink to red color (1, 6).
NOTE 2—If the pH of the rhodizonate reagent is neutral or basic, the characteristic color change for lead is from yellow/orange to blue or violet. However,
under neutral or basic conditions, athe blue or violet color change is not specific for lead (1, 6).
8.2.1.2 Rhodizonate based tests are rapid, easy, and relatively inexpensive to use.
8.2.2 Rhodizonate Disadvantages:
8.2.2.1 Rhodizonate based spot tests shall not be used on red or pink paint that rubs off or bleeds color. However, rhodizonate
based spot tests that use absorbent applicators to apply the test reagents may be used on red or pink paint that does not bleed color.
NOTE 3—It may be
...