ASTM F2058-07(2021)
(Specification)Standard Specification for Candle Fire Safety Labeling
Standard Specification for Candle Fire Safety Labeling
ABSTRACT
This specification covers requirements for fire safety information to be placed on candle units of sale. It also includes requirements that retailers and distributors shall follow. Fire safety warnings will help ensure that information concerning the safe use of candles is presented to consumers to help prevent fires. The fire safety warning must be placed on the unit of sale and shall be visible to the consumer at the point of sale. The fire safety warning shall not be covered, obstructed, or removed by the manufacturer, distributor or retailer. The text-only fire safety warning shall consist of the safety alert symbol followed immediately by the signal word “WARNING” in uppercase boldface letters. The text-and-pictogram fire safety warning shall consist of the safety alert symbol followed immediately by the pictograms.
SIGNIFICANCE AND USE
5.1 Fire safety warnings will help ensure that information concerning the safe use of candles is presented to consumers to help prevent fires.
SCOPE
1.1 This specification covers requirements for fire safety information to be placed on candle units of sale. It also includes requirements that retailers and distributors shall follow. It is not the intent of this specification to address any other labeling requirements.2
1.2 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
- Status
- Published
- Publication Date
- 31-Jan-2021
- Technical Committee
- F15 - Consumer Products
- Drafting Committee
- F15.45 - Candle Products
Relations
- Refers
ASTM F1972-19 - Standard Guide for Terminology Relating to Candles and Associated Accessory Items - Effective Date
- 01-Apr-2019
- Refers
ASTM F1972-16 - Standard Guide for Terminology Relating to Candles and Associated Accessory Items - Effective Date
- 01-May-2016
- Refers
ASTM F1972-13 - Standard Guide for Terminology Relating to Candles and Associated Accessory Items - Effective Date
- 01-Sep-2013
- Refers
ASTM F1972-05 - Standard Guide for Terminology Relating to Candles and Associated Accessory Items - Effective Date
- 01-Sep-2005
- Refers
ASTM F1972-05e1 - Standard Guide for Terminology Relating to Candles and Associated Accessory Items - Effective Date
- 01-Sep-2005
- Refers
ASTM F1972-99 - Standard Guide for Terminology Relating to Candles and Associated Accessory Items - Effective Date
- 10-Jun-1999
Overview
ASTM F2058-07(2021): Standard Specification for Candle Fire Safety Labeling establishes the requirements for placing fire safety information on candle products sold to consumers. Published by ASTM International, this standard ensures that all candles are accompanied by clear, visible fire safety warnings to help prevent accidental fires. The scope encompasses both the labeling of individual candle units as well as requirements that apply to manufacturers, retailers, and distributors. Key measures include specification of mandatory safety symbols, warning statements, and minimum label size requirements, thereby supporting consumer safety and regulatory compliance in the candle industry.
Key Topics
- Fire Safety Warning Content: The standard requires fire safety information featuring the safety alert symbol, signal word "WARNING" in bold uppercase, and essential safety instructions.
- Label Placement and Visibility: Fire safety warnings must be placed on the top or sides of the candle or its packaging and be visible at the point of sale. Labels cannot be covered or removed by any party in the supply chain.
- Label Options:
- Text-Only Option: Warnings stating "Burn within sight," "Keep away from things that catch fire," and "Keep away from children" in a clear, legible format.
- Text and Pictogram Option: Warnings use internationally recognized graphic symbols (pictograms) to convey key safety messages alongside text.
- Size Requirements: The minimum size for labels, symbols, and letters is determined by the surface area of the warning panel and is detailed in tabular requirements within the standard.
- Applicability: The specification applies to consumer candles except birthday candles and those used in places of worship, commercial, or industrial settings.
- International Compliance: Developed in line with World Trade Organization (WTO) Technical Barriers to Trade (TBT) principles for global acceptance.
Applications
ASTM F2058-07(2021) is crucial for:
- Candle Manufacturers: Ensuring that all products include compliant fire safety labeling before distribution, reducing legal risks, and demonstrating commitment to consumer safety.
- Retailers and Distributors: Verifying that fire safety warnings remain visible and unobstructed on products at the point of sale, maintaining legal and regulatory compliance.
- Product Safety Professionals: Implementing fire safety labeling as part of risk management and quality assurance processes in consumer goods.
- Importers and Exporters: Facilitating market access by meeting internationally recognized candle labeling requirements, particularly for products destined for regions with strict fire safety regulations.
- Consumer Education: Helping end-users understand and adhere to proper candle use, minimizing fire hazards in homes and businesses.
Related Standards
For comprehensive product safety and labeling, the following related ASTM standards are referenced:
- ASTM F1972 - Guide for Terminology Relating to Candles and Associated Accessory Items: Provides essential definitions used in candle safety and labeling.
- Worldwide Principles - Developed in accordance with internationally recognized standardization principles established by the WTO TBT Committee.
By adhering to ASTM F2058-07(2021), stakeholders across the candle industry promote safer consumer experiences, reduce fire risks, and ensure products meet both national and international safety expectations. For more information on candle fire safety pictograms, visit candles.org/pictograms.
Buy Documents
ASTM F2058-07(2021) - Standard Specification for Candle Fire Safety Labeling
Get Certified
Connect with accredited certification bodies for this standard

ECOCERT
Organic and sustainability certification.

NSF International
Global independent organization facilitating standards development and certification.
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.
Sponsored listings
Frequently Asked Questions
ASTM F2058-07(2021) is a technical specification published by ASTM International. Its full title is "Standard Specification for Candle Fire Safety Labeling". This standard covers: ABSTRACT This specification covers requirements for fire safety information to be placed on candle units of sale. It also includes requirements that retailers and distributors shall follow. Fire safety warnings will help ensure that information concerning the safe use of candles is presented to consumers to help prevent fires. The fire safety warning must be placed on the unit of sale and shall be visible to the consumer at the point of sale. The fire safety warning shall not be covered, obstructed, or removed by the manufacturer, distributor or retailer. The text-only fire safety warning shall consist of the safety alert symbol followed immediately by the signal word “WARNING” in uppercase boldface letters. The text-and-pictogram fire safety warning shall consist of the safety alert symbol followed immediately by the pictograms. SIGNIFICANCE AND USE 5.1 Fire safety warnings will help ensure that information concerning the safe use of candles is presented to consumers to help prevent fires. SCOPE 1.1 This specification covers requirements for fire safety information to be placed on candle units of sale. It also includes requirements that retailers and distributors shall follow. It is not the intent of this specification to address any other labeling requirements.2 1.2 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ABSTRACT This specification covers requirements for fire safety information to be placed on candle units of sale. It also includes requirements that retailers and distributors shall follow. Fire safety warnings will help ensure that information concerning the safe use of candles is presented to consumers to help prevent fires. The fire safety warning must be placed on the unit of sale and shall be visible to the consumer at the point of sale. The fire safety warning shall not be covered, obstructed, or removed by the manufacturer, distributor or retailer. The text-only fire safety warning shall consist of the safety alert symbol followed immediately by the signal word “WARNING” in uppercase boldface letters. The text-and-pictogram fire safety warning shall consist of the safety alert symbol followed immediately by the pictograms. SIGNIFICANCE AND USE 5.1 Fire safety warnings will help ensure that information concerning the safe use of candles is presented to consumers to help prevent fires. SCOPE 1.1 This specification covers requirements for fire safety information to be placed on candle units of sale. It also includes requirements that retailers and distributors shall follow. It is not the intent of this specification to address any other labeling requirements.2 1.2 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM F2058-07(2021) is classified under the following ICS (International Classification for Standards) categories: 13.200 - Accident and disaster control; 71.100.99 - Other products of the chemical industry. The ICS classification helps identify the subject area and facilitates finding related standards.
ASTM F2058-07(2021) has the following relationships with other standards: It is inter standard links to ASTM F1972-19, ASTM F1972-16, ASTM F1972-13, ASTM F1972-05, ASTM F1972-05e1, ASTM F1972-99. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ASTM F2058-07(2021) is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:F2058 −07 (Reapproved 2021)
Standard Specification for
Candle Fire Safety Labeling
This standard is issued under the fixed designation F2058; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 3.1.1 Certain candle-related terminology is addressed in
Guide F1972, and the reader is directed to that guide for
1.1 This specification covers requirements for fire safety
definitions not found in the following:
information to be placed on candle units of sale. It also
3.1.2 filled candle, n—a candle produced and used within
includes requirements that retailers and distributors shall fol-
the same vessel.
low.Itisnottheintentofthisspecificationtoaddressanyother
3.1.3 fire safety warning, n—precautionary information on
labeling requirements.
the label, consisting of the safety alert symbol, the signal word
1.2 This international standard was developed in accor-
(ifpresent),thefiresafetywarningstatement(s)andpictograms
dance with internationally recognized principles on standard-
(if present) required by this standard to appear on the unit of
ization established in the Decision on Principles for the
sale.
Development of International Standards, Guides and Recom-
3.1.4 fire safety warning statement(s), n—specific warning
mendations issued by the World Trade Organization Technical
message(s) required by this standard.
Barriers to Trade (TBT) Committee.
3.1.5 freestanding candle, n—rigid candle (for example,
2. Referenced Documents
pillar-shaped,column-shaped,orfigurine)thatisintendedtobe
burned only on a heat-resistant, noncombustible surface or on
2.1 ASTM Standards:
F1972Guide for Terminology Relating to Candles and a heat-resistant, noncombustible candle accessory.
Associated Accessory Items
3.1.6 label, n—display of textual or graphic matter on the
unit of sale.
3. Terminology
3.1.7 packaging, n—external container, such as a box, case,
3.1 Definitions of Terms Specific to This Standard:
bag or sleeve in which a candle(s) is sold. Packaging does not
include the vessel of a filled candle.
This specification is under the jurisdiction of ASTM Committee F15 on
3.1.8 pictogram, n—graphic symbol intended to convey a
Consumer Products and is the direct responsibility of Subcommittee F15.45 on
message without the use of words.
Candle Products.
3.1.9 safety alert symbol, n—graphic symbol consisting of
Current edition approved Feb. 1, 2021. Published February 2021. Originally
approved in 2000. Last previous edition approved in 2014 as F2058–07(2014).
an exclamation point inside of an equilateral triangle with the
DOI: 10.1520/F2058-07R21.
point of the triangle oriented upward (see 4.1).
It is possible that labels for use or distribution in certain countries, states,
communitiesorlocationswillrequireotherinformationnotcoveredinthisstandard 3.1.10 signal word, n—thewordWARNINGasitappearsin
or additional language(s). It is the responsibility of the manufacturer to determine
the fire safety warning.
what additional information is necessary to comply with other applicable labeling
3.1.11 unit of sale, n—thecandle,orcandleanditscontainer
regulations.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
or package, as purchased by the consumer.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3.1.12 warning panel, n—entire surface of the panel on
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. which the fire safety warning appears on the unit of sale.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F2058−07 (2021)
4. Graphic Symbols Specific To This Standard (1)The fire safety warning shall appear on the top or sides
of the packaging, or must be otherwise attached to the
4.1 Safety Alert Symbol:
packaging (such as a tag). It cannot be on the bottom of the
package as intended for display at retail unless the statement
“See bottom panel for safety information” or its practical
equivalent appears on the top or a side of the packaging with
a minimum letter height of 1.5 mm (0.06 in.) based on the
height of a capital or upper case letter.
(2) For free standing and filled candles (excluding
4.2 Pictogram for “Burn within sight”:
tealights), the fire safety warning must appear on the top,
bottom, or a side of the candle as well as on the packaging.
(3)When the sole packaging consists of a transparent
material (such as a clear shrink wrap) and the fire safety
warningisvisibleonthetop,bottomorasideofthecandle,the
fire safety warning and the statement “See bottom panel for
safety information” is not required on the packaging.
4.3 Pictogram for “Keep away from things that catch fire”:
6.2.2 The fire safety warning shall be in distinct contrast
from its background. Its message(s) shall be in a legible
sans-serif font, such as Helvetica, Century Gothic, or equiva-
lent typeface, in combinations of uppercase and lowercase
letters unless otherwise specified.
6.2.3 The fire safety warning need not be limited to a
4.4 Pictogram for “Keep away from children”: specific shape. It can conform to the shape of the overall label
to allow for the most efficient use of available space. It is
permissible to outline the fire safety warning with a border.
6.2.4 There are two fire safety warning options. One is a
text-onlyoption(see6.3)andtheotherisatext-and-pictogram
option(see6.4).Allunitsofsaleshallcomplywithoneofthese
two labeling options.
6.2.5 The fire safety warning statement(s) specified in this
5. Significance and Use
standard represent minimum fire safety warning requirements.
5.1 Fire safety warnings will help ensure that information
Additionalappropriatemanufacturers’warningsorinstructions
concerningthesafeuseofcandlesispresentedtoconsumersto
are permitted. These warnings or instructions can precede or
help prevent fires.
follow the fire safety warning or appear elsewhere on the unit
of sale, but cannot interrupt the fire safety warning.
6. Requirements
6.2.6 Thetotalsurfaceareaofthewarningpaneldetermines
6.1 Exclusions—Thisspecificationdoesnotpertaintobirth-
the minimum letter height, graphic symbol size and content of
day candles or candles intended for places of worship, com-
thefiresafetywarning.Guidanceonhowtodeterminethetotal
mercial institutions, or industrial use.
surface area of the warning panel is shown in Appendix X1.
6.2.7 Example labels are provided in Appendix X2.
6.2 General:
6.2.1 The fire safety warning must be placed on the unit of
6.3 Fire Safety Warning (Text-Only Option):
sale and shall be visible to the consumer at the point of sale.
6.3.1 The text-only fire safety warning shall consist of the
The fire safety warning shall not be covered, obstructed, or
safety alert symbol followed immediately by the signal word
removed by the manufacturer, distributor or retailer.
“WARNING” in uppercase boldface letters, after which the
6.2.1.1 When the unit of sale consists solely of a candle
following fire safety warning statements or their practical
(including its vessel if present), the fire safety warning shall
equivalents shall appear in this order:
appear on the top, bottom, or a side of the candle, or be
Burn within sight.
attached to the candle (such as a tag).
Keep away from things that catch fire.
6.2.1.2 When the unit of sale consists of a candle and its
Keep away from children.
packaging:
It is permissible for these statements to appear in stacked
format or in paragraph form.
2 2
4 6.3.2 For candles with warning panels of 21 cm (3.3 in. )
The fire-safety pictograms in Section 4 were created by the National Candle
or less, and for all individually labeled taper candles, manu-
Association for the express purpose of developing universally recognized graphic
symbols depicting important candle fire-safety precautions. The National Candle
facturers have the option of using an abbreviated text-only fire
Association has granted to the public the free, universal, and unrestricted rights to
safety warning consisting solely of the safety alert symbol and
use these candle fire-safety symbols without its permission or consideration.
the single fire safety warning statement “Burn within sight” or
Reproduction-quality images of the fire-safety pictograms can be accessed by the
public, without charge, at www.candles.org/pictograms. its practical equivalent.
F2058−07 (2021)
TABLE 1 Minimum Size Requirements for the Components of the
Text-Only Fire Safety Warning Option
Surface Area Minimum Height of Minimum Height of
of the Warning the Safety Alert Symbol Fire Safety Warning
Panel and the Signal Word Statements
“WARNING”
2 2 B
21 cm (3.3 in. ) 1.5 mm (0.06 in.) 1.3 mm (0.05 in.)
A
or less
B
Greater than 1.5 mm (0.06 in.) 1.3 mm (0.05 in.)
2 2
21 cm (3.3 in. )
but less than
2 2
60 cm (9.3 in. )
2 2 B
60 cm (9.3 in. ) 1.8 mm (0.07 in.) 1.5 mm (0.06 in.)
or greater
A
This size label qualifies for the abbreviated text-only fire safety warning option.
See 6.3.2.
B
Minimum height of letters is based on the height of a capital or upper case letter.
TABLE 2 Minimum Size Requirements for the Components of the Text-and-Pictogram Fire Safety Warning Option
Surface Area of Minimum Height of Minimum Diameter of Minimum Height of
the Warning Panel the Safety Alert Symbol the Pictograms the Fire Safety Warning
Statements
2 2 A B C
21 cm (3.3 in. )orless 4mm(0.15 in.) 8 mm (0.31 in.) 1.3 mm (0.05 in.)
2 2 B C
Greater than 21 cm (3.3 in. ) 5mm(0.20 in.) 10 mm (0.39 in.) 1.3 mm (0.05 in.)
2 2
but less than 60 cm (9.3 in. )
2 2 B C
60 cm (9.3 in. ) or greater 8 mm (0.31 in.) 16 mm (0.63 in.) 1.5 mm (0.06 in.)
A
This size label qualifies for the abbreviated text-and-pictogram fire safety warning option. See 6.4.2.
B
The minimum height of the safety alert symbol must always be at least half the height of the pictogram(s). If the pictogram(s) is larger than the minimum size, the safety
alert symbol must be enlarged to at least half of the pictogram’s height.
C
Minimum height of letters is based on the height of a capital or upper case letter.
2 2
6.3.3 The minimum size requirements for components of 6.4.2 Forcandleswithwarningpanelsof21cm (3.3in. )or
the text-only fire safety warning (including the abbreviated less, and for all individually labeled taper candles, manufac-
text-only fire safety warning) are indicated in Table 1.
turers have the option of using an abbreviated text-and-
pictogram fire safety warning consisting solely of the safety
6.4 Fire Safety Warning (Text-and-Pictogram Option):
alert symbol followed by the “Burn within sight” pictogram
6.4.1 The text-and-pictogram fire safety warning shall con-
(see 4.2) and the fire safety warning statement “Burn within
sist of the safety alert symbol followed immediately by the
sight” or its prac
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...