Standard Specification for Concrete Pipe for Irrigation or Drainage

ABSTRACT
This specification covers nonreinforced concrete pipe to be used for the conveyance of irrigation water with working pressures, including hydraulic transients and for use in drainage. The concrete shall consist of cementitious materials, minerals, aggregates, and water. Cement shall conform to the requirements for Portland cement or shall be Portland blast-furnace slag cement, or slag modified Portland cement, or Portland-pozzolan cement conforming to the requirements except that the pozzolan constituent in the Type IP Portland-pozzolan cement shall be fly ash. The combination of cementitious materials used in the concrete shall be one of the following: Portland cement only, Portland blast furnace slag cement only, slag modified portland cement only, portland pozzolan cement only, a combination of Portland cement and fly ash, a combination of portland cement and ground-granulated blast-furnace slag or a combination of fly ash and ground granulated blast furnace slag. The specimens shall undergo external load test, absorption test and hydrostatic test. The material shall also conform to the required internal diameter and wall thickness.
SCOPE
1.1 This specification covers nonreinforced concrete pipe to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1 and for use in drainage.
1.2 A complete SI companion to Specification C118 has been developedC118M; therefore, no SI equivalents are presented in this specification.
Note 1—This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.  
TABLE 1 Standard Dimensions, Working Pressure, and Test Requirements for Standard Concrete Irrigation PipeA
   Internal Designated Diameter, in.Thickness
of Wall,
T, in.Working
Pressure,B
ftMinimum Internal Hydrostatic Test Pressure, psiMinimum
Three-Edge-Bearing
Load, lbf/linear ft  67/830501300  813050 1350 10 11/830501400 12 1¼25451500 14 13/825451600 15 1½25451650 16 1½25451700 18 1¾25451800 20 225401850 21 21/825401900 24 2¼25402000
A For hydrostatic test requirements, refer to 10.5.
B Higher working pressures are not prohibited up to a maximum of 40 ft for 6 through 8-in. diameters, 35 ft for 10 through 12-in. diameters, and 30 ft. for 14-in. through 24-in. diameters. In these cases, the strength of the pipe shall be increased to give a minimum of at least four times the design working pressure when tested as specified in 10.5.

General Information

Status
Historical
Publication Date
31-Aug-2011
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C118-11 - Standard Specification for Concrete Pipe for Irrigation or Drainage
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C118-11 - Standard Specification for Concrete Pipe for Irrigation or Drainage
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C118 −11
StandardSpecification for
1
Concrete Pipe for Irrigation or Drainage
This standard is issued under the fixed designation C118; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 4. Classification
4.1 Pipe manufactured according to this specification shall
1.1 This specification covers nonreinforced concrete pipe to
be known as “ASTM Standard Concrete Irrigation Pipe,”
be used for the conveyance of irrigation water with working
“ASTM Standard Concrete Drainage Pipe,” or “ASTM Heavy-
pressures, including hydraulic transients, as shown in Table 1
Duty Concrete Drainage Pipe.”
and for use in drainage.
1.2 A complete SI companion to Specification C118 has
5. Basis of Acceptance
been developed—C118M; therefore, no SI equivalents are
5.1 The acceptability of the pipe shall be determined by the
presented in this specification.
results of the tests prescribed in this specification, if and when
NOTE 1—This specification is for manufacturing and purchase only and
required and by inspection to determine whether the pipe
does not include requirements for bedding, backfill, installation, or field
conforms to this specification as to design and freedom from
repairs.Theowneriscautionedthathemustcorrelatefieldconditionswith
defects.
the characteristics of the pipe specified and provide inspection during
installation.
6. Materials
2. Referenced Documents
6.1 Concrete—The concrete shall consist of cementitious
2
materials, mineral, aggregates, and water.
2.1 ASTM Standards:
C33 Specification for Concrete Aggregates
6.2 Cementitious Materials:
C150 Specification for Portland Cement
6.2.1 Cement—Cement shall conform to the requirements
C497 Test Methods for Concrete Pipe, Manhole Sections, or
for portland cement of Specification C150 or shall be portland
Tile
blast-furnace slag cement, or slag modified portland cement, or
C595 Specification for Blended Hydraulic Cements
portland-pozzolan cement conforming to the requirements of
C618 Specification for Coal Fly Ash and Raw or Calcined
Specification C595, except that the pozzolan constituent in the
Natural Pozzolan for Use in Concrete
Type IP portland-pozzolan cement shall be fly ash.
C822 Terminology Relating to Concrete Pipe and Related
6.2.2 Fly Ash—Fly ash shall conform to the requirements of
Products
Specification C618, Class F or Class C.
C989 Specification for Slag Cement for Use in Concrete and
6.2.3 Ground Granulated Blast Furnace Slag (GGBFS)—
Mortars
GGBFS shall conform to the requirements of Grade 100 or 120
C1116/C1116M Specification for Fiber-Reinforced Concrete
of Specification C989.
6.2.4 Allowable Combinations of Cementitious Materials—
3. Terminology
Thecombinationofcementitiousmaterialsusedintheconcrete
3.1 Definitions—Fordefinitionsoftermsrelatingtoconcrete shall be one of the following:
pipe, see Terminology C822. 6.2.4.1 Portland cement only,
6.2.4.2 Portland blast furnace slag cement only,
6.2.4.3 Slag modified portland cement only,
1
6.2.4.4 Portland pozzolan cement only,
This specification is under the jurisdiction of ASTM Committee C13 on
Concrete Pipe and is the direct responsibility of Subcommittee C13.01 on
6.2.4.5 A combination of portland cement and fly ash,
Non-Reinforced Concrete Sewer, Drain and Irrigation Pipe.
6.2.4.6 A combination of portland cement and ground
Current edition approved Sept. 1, 2011. Published October 2011. Originally
granulated blast-furnace slag, or
approved in 1935. Last previous edition approved in 2005 as C118 – 05a. DOI:
10.1520/C0118-11.
6.2.4.7 A combination of portland cement, fly ash (not to
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
exceed 25 % of the total cementitious weight) and ground
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
granulated blast furnace slag (not to exceed 25 % of the total
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. cementitious weight).
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C118−11
TABLE 1 Standard Dimensions, Working Pressure, and Test
7.2 Modified Design—Manufacturers shall submit to the
A
Requirements for Standard Concrete Irrigation Pipe
owner for approval prior to manufacture, wall thicknesses
Minimum Minimum
other than those shown in Table 1 or Table 2. Such pipe shall
Internal Thickness Internal Three-Edge-Bearing
Working
B meet all of the test and performance requirements specified by
Designated of Wall, Hydrostatic Load, lbf/linear ft
P
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C118–05a Designation: C118 – 11
Standard Specification for
1
Concrete Pipe for Irrigation or Drainage
This standard is issued under the fixed designation C118; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers nonreinforced concrete pipe to be used for the conveyance of irrigation water with working
pressures, including hydraulic transients, as shown in Table 1 and for use in drainage.
1.2 A complete SI companion to Specification C118 has been developed—C118M; therefore, no SI equivalents are presented
in this specification.
NOTE 1—Thisspecificationisformanufacturingandpurchaseonlyanddoesnotincluderequirementsforbedding,backfill,installation,orfieldrepairs.
The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.
2. Referenced Documents
2
2.1 ASTM Standards:
C33 Specification for Concrete Aggregates
C150 Specification for Portland Cement
C497 Test Methods for Concrete Pipe, Manhole Sections, or Tile
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C822 Terminology Relating to Concrete Pipe and Related Products
C989 Specification for Slag Cement for Use in Concrete and Mortars
C1116/C1116M Specification for Fiber-Reinforced Concrete
3. Terminology
3.1 Definitions—For definitions of terms relating to concrete pipe, see Terminology C822.
4. Classification
4.1 Pipe manufactured according to this specification shall be known as “ASTM Standard Concrete Irrigation Pipe,” “ASTM
Standard Concrete Drainage Pipe,” or “ASTM Heavy-Duty Concrete Drainage Pipe.”
5. Basis of Acceptance
5.1 The acceptability of the pipe shall be determined by the results of the tests prescribed in this specification, if and when
required and by inspection to determine whether the pipe conforms to this specification as to design and freedom from defects.
6. Materials
6.1 Concrete—The concrete shall consist of cementitious materials, mineral, aggregates, and water.
6.2 Cementitious Materials:
6.2.1 Cement—Cement shall conform to the requirements for portland cement of Specification C150 or shall be portland
blast-furnace slag cement, or slag modified portland cement, or portland-pozzolan cement conforming to the requirements of
Specification C595, except that the pozzolan constituent in the Type IP portland-pozzolan cement shall be fly ash.
6.2.2 Fly Ash—Fly ash shall conform to the requirements of Specification C618, Class F or Class C.
6.2.3 Ground Granulated Blast Furnace Slag (GGBFS)—GGBFS shall conform to the requirements of Grade 100 or 120 of
Specification C989.
1
This specification is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.01 on Non-Reinforced
Concrete Sewer, Drain and Irrigation Pipe.
Current edition approved Dec.Sept. 1, 2005.2011. Published January 2006.October 2011. Originally approved in 1935. Last previous edition approved in 2005 as
C118 – 05a. DOI: 10.1520/C0118-05A.10.1520/C0118-11.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C118 – 11
TABLE 1 Standard Dimensions, Working Pressure, and Test
A
Requirements for Standard Concrete Irrigation Pipe
Minimum Minimum
Internal Thickness Working Internal Three-Edge-Bearing
B
Designated of Wall, Pressure, Hydrostatic Load, lbf/linear ft
Diameter, in. T,in. ft Test Pressure,
psi
7
6 ⁄8 30 50 1300
8 1 30 50 1350
1
10 1 ⁄8 30 50 1400
1
12 1 ⁄4 25 45 1500
3
14 1 ⁄8 25 45 1600
1
15 1 ⁄2 25 45 1650
1
16 1 ⁄2 25 45 1700
3
18 1 ⁄4 25 45 1800
20 2 25 40 1850
1
21 2 ⁄8 25 40 1900
1
24 2 ⁄4 25 40 2000
A
For hydrostatic test requirements, refer to 10.5.
B
Higher working pressures are not prohibited up to a maximum of 40 ft for 6
through 8-in. diameters, 35 ft for 10 through 12-in. diameters, and 30 ft. for 14-in.
through 24-in. diameters. In these cases, the strength
...

Questions, Comments and Discussion