Standard Specification for Joints for IPS PVC Pipe Using Solvent Cement

ABSTRACT
This specification covers requirements, testing, and performance characteristics of joints for IPS PVC pipe using solvent cement. Testing requirements for both pressure and non-pressure pipe shall include socket dimensions, burst pressure, and joint tightness tests. PVC plastics, solvent cements, primer materials, workmanship, sampling, conditioning, marking, and quality shall conform to the requirements of this specification.
SCOPE
1.1 This specification covers the socket produced for solvent cement joints on both pressure and non-pressure IPS pipe. It also covers the testing of the joints on both pressure and non-pressure pipe, and includes requirements for socket dimensions, burst pressure, and joint tightness tests of the solvent cemented joints. The tests described are not intended for routine quality control, but rather to evaluate the performance characteristics of the joint.  
Note 1: On dual marked Schedule 40 DWV and potable water pipe, the socket bells must conform to the dimensional and physical requirements for pressure socket bells.  
1.2 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.  
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
Note 2: Changes in ground, water, or air temperature will produce expansion or contraction forces in PVC piping, and these will result in longitudinal shear stresses in the solvent cement joints. These stresses must be considered in the design and operation of the system.
Note 3: See Practice D618 for information relating to this specification.  
1.4 The following safety hazards caveat pertains only to the test method portion, Section 10, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
14-Nov-2014
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D2672-14 - Standard Specification for Joints for IPS PVC Pipe Using Solvent Cement
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM D2672-14 - Standard Specification for Joints for IPS PVC Pipe Using Solvent Cement
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D2672 −14 An American National Standard
Standard Specification for
1
Joints for IPS PVC Pipe Using Solvent Cement
This standard is issued under the fixed designation D2672; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
1.1 This specification covers the socket produced for sol-
vent cement joints on both pressure and non-pressure IPS pipe.
2. Referenced Documents
It also covers the testing of the joints on both pressure and
2
2.1 ASTM Standards:
non-pressure pipe, and includes requirements for socket
D618 Practice for Conditioning Plastics for Testing
dimensions, burst pressure, and joint tightness tests of the
D1599 Test Method for Resistance to Short-Time Hydraulic
solvent cemented joints. The tests described are not intended
Pressure of Plastic Pipe, Tubing, and Fittings
for routine quality control, but rather to evaluate the perfor-
D1600 Terminology forAbbreviatedTerms Relating to Plas-
mance characteristics of the joint.
tics
NOTE 1—On dual marked Schedule 40 DWV and potable water pipe,
D1785 Specification for Poly(Vinyl Chloride) (PVC) Plastic
the socket bells must conform to the dimensional and physical require-
Pipe, Schedules 40, 80, and 120
ments for pressure socket bells.
D2122 Test Method for Determining Dimensions of Ther-
1.2 The text of this specification references notes, footnotes,
moplastic Pipe and Fittings
and appendixes which provide explanatory material. These
D2241 Specification for Poly(Vinyl Chloride) (PVC)
notesandfootnotes(excludingthoseintablesandfigures)shall
Pressure-Rated Pipe (SDR Series)
not be considered as requirements of the specification.
D2565 Practice for Xenon-Arc Exposure of Plastics In-
1.3 The values stated in inch-pound units are to be regarded tended for Outdoor Applications
D2665 Specification for Poly(Vinyl Chloride) (PVC) Plastic
as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only Drain, Waste, and Vent Pipe and Fittings
D2855 Practice for the Two-Step (Primer and Solvent Ce-
and are not considered standard.
ment) Method of Joining Poly (Vinyl Chloride) (PVC) or
NOTE 2—Changes in ground, water, or air temperature will produce
Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and
expansion or contraction forces in PVC piping, and these will result in
Piping Components with Tapered Sockets
longitudinal shear stresses in the solvent cement joints. These stresses
must be considered in the design and operation of the system. F412 Terminology Relating to Plastic Piping Systems
NOTE 3—See Practice D618 for information relating to this specifica-
F512 Specification for Smooth-Wall Poly(Vinyl Chloride)
tion.
(PVC) Conduit and Fittings for Underground Installation
1.4 The following safety hazards caveat pertains only to the
F656 Specification for Primers for Use in Solvent Cement
test method portion, Section 10, of this specification. This
Joints of Poly(Vinyl Chloride) (PVC) Plastic Pipe and
standard does not purport to address all of the safety concerns,
Fittings
if any, associated with its use. It is the responsibility of the user
2.2 NSF Standard:
of this standard to establish appropriate safety, health, and
Standard No. 14 for Plastic Piping Components and Related
3
environmental practices and determine the applicability of
Materials
regulatory limitations prior to use.
3. Terminology
1.5 This international standard was developed in accor-
dance with internationally recognized principles on standard-
3.1 Definitions—Definitions are in accordance with Termi-
ization established in the Decision on Principles for the
nology F412 and abbreviations are in accordance with Termi-
Development of International Standards, Guides and Recom-
nology D1600, unless otherwise specified.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Piping Systems and is the direct responsibility of Subcommittee F17.20 on Joining. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Nov. 15, 2014. Published February 2015. Originally the ASTM website.
3
approved in 1968. Last previous edition approved in 2009 as D2672 – 96a(2009). Available from NSF International, P.O. Box 130140, 789 N. Dixboro Rd.,Ann
DOI: 10.1520/D2672-14. Arbor, MI 48113-0140, http://www.nsf.org.
*A Summary of Changes sect
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D2672 − 96a (Reapproved 2009) D2672 − 14
Standard Specification for
1
Joints for IPS PVC Pipe Using Solvent Cement
This standard is issued under the fixed designation D2672; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope Scope*
1.1 This specification covers the socket produced for solvent cement joints on both pressure and non-pressure IPS pipe. It also
covers the testing of the joints on both pressure and non-pressure pipe, and includes requirements for socket dimensions, burst
pressure, and joint tightness tests of the solvent cemented joints. The tests described are not intended for routine quality control,
but rather to evaluate the performance characteristics of the joint.
NOTE 1—On dual marked Schedule 40 DWV and potable water pipe, the socket bells must conform to the dimensional and physical requirements for
pressure socket bells.
1.2 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes
and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
NOTE 2—Changes in ground, water, or air temperature will produce expansion or contraction forces in PVC piping, and these will result in longitudinal
shear stresses in the solvent cement joints. These stresses must be considered in the design and operation of the system.
NOTE 3—See Practice D618 for information relating to this specification.
1.4 The following safety hazards caveat pertains only to the test method portion, Section 10, of this specification.This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D1599 Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1785 Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80, and 120
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2241 Specification for Poly(Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series)
D2565 Practice for Xenon-Arc Exposure of Plastics Intended for Outdoor Applications
D2665 Specification for Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings
D2855 Practice for Making Solvent-Cemented Joints with Poly(Vinyl Chloride) (PVC) Pipe and Fittings
F412 Terminology Relating to Plastic Piping Systems
F512 Specification for Smooth-Wall Poly(Vinyl Chloride) (PVC) Conduit and Fittings for Underground Installation
F656 Specification for Primers for Use in Solvent Cement Joints of Poly(Vinyl Chloride) (PVC) Plastic Pipe and Fittings
2.2 NSF Standard:
3
Standard No. 14 for Plastic Piping Components and Related Materials
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.20 on Joining.
Current edition approved Aug. 1, 2009Nov. 15, 2014. Published September 2009February 2015. Originally approved in 1968. Last previous edition approved in 20032009
as D2672 – 96a(2003).(2009). DOI: 10.1520/D2672-96AR09.10.1520/D2672-14.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from NSF International, P.O. Box 130140, 789 N. Dixboro Rd., Ann Arbor, MI 48113-0140, http://www.nsf.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Pag
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.