2004-01-5945 - Pravilnik o grafičnih znakih za izdelavo prilog študij požarne varnosti in požarnih redov
Pravilnik o grafičnih znakih za izdelavo prilog študij požarne varnosti in požarnih redov
Pravilnik o grafičnih znakih za izdelavo prilog študij požarne varnosti in požarnih redov
General Information
Frequently Asked Questions
An EU Regulation is a binding legislative act that must be applied in its entirety across the European Union. Unlike directives, regulations do not need to be transposed into national law and are directly applicable in all member states. Regulations are used when uniform application across all EU countries is essential.
Slovenian Regulation 2004-01-5945 covers "Pravilnik o grafičnih znakih za izdelavo prilog študij požarne varnosti in požarnih redov". There are 5 standards associated with this slovenian regulation.
Harmonized standards under 2004-01-5945 are European standards (ENs) developed by CEN, CENELEC, or ETSI in response to a mandate from the European Commission. When these standards are cited in the Official Journal of the European Union, products manufactured in conformity with them benefit from a presumption of conformity with the essential requirements of 2004-01-5945, facilitating CE marking and free movement within the European Economic Area.
IEC 60079-10-1:2020 is concerned with the classification of areas where flammable gas or vapour hazards may arise and may then be used as a basis to support the proper design, construction, operation and maintenance of equipment for use in hazardous areas.
It is intended to be applied where there may be an ignition hazard due to the presence of flammable gas or vapour, mixed with air, but it does not apply to:
a) mines susceptible to firedamp;
b) the processing and manufacture of explosives;
c) catastrophic failures or rare malfunctions which are beyond the concept of normality dealt with in this standard;
d) rooms used for medical purposes;
e) domestic premises;
f) where a hazard may arise due to the presence of combustible dusts or combustible flyings but the principles may be used in assessment of a hybrid mixture.
Flammable mists may form or be present at the same time as flammable vapour. In such case the strict application of the details in this document may not be appropriate. Flammable mists may also form when liquids not considered to be a hazard due to the high flash point are released under pressure. In these cases the classifications and details given in this document do not apply.
For the purpose of this document, an area is a three-dimensional region or space.
Atmospheric conditions include variations above and below reference levels of 101,3 kPa (1 013 mbar) and 20 °C (293 K), provided that the variations have a negligible effect on the explosion properties of the flammable substances.
In any site, irrespective of size, there may be numerous sources of ignition apart from those associated with equipment. Appropriate precautions will be necessary to ensure safety in this context. This standard is applicable with judgement for other ignition sources but in some applications other safeguards may also need to be considered. E.g. larger distances may apply for naked flames when considering hot work permits.
This document does not take into account the consequences of ignition of an explosive atmosphere except where a zone is so small that if ignition did occur it would have negligible consequences.
This third edition of IEC 60079-10-1 cancels and replaces the second edition, published in 2015, and constitutes a technical revision, see foreword for further details.
- Standard115 pagesEnglish languagee-Library read for1 day
- Standard30 pagesEnglish languagee-Library read for1 day
Ta slovenski standard predpisuje obliko, velikost, barve, izvedbo in namestitev varnostnih
znakov za ozna~itev smeri evakuacijskih poti in izhodov ter znakov za ozna~itev naprav za
ga{enje in ro~nih javljalnikov po`ara.
- Standard13 pagesSlovenian languagee-Library read for1 day
- Corrigendum1 pageSlovenian languagee-Library read for1 day
- Corrigendum1 pageSlovenian languagee-Library read for1 day
Establishes symbols to be used in architectural, engineering, building and allied design fields to provide details of equipment for fire protection, fire-fighting and means of escape on drawings for design, construction, renovation or fire certification purposes.
- Standard12 pagesEnglish languagesale 15% off
- Standard10 pagesEnglish and French languagee-Library read for1 day
- Standard10 pagesEnglish and French languagee-Library read for1 day