ECISS/TC 29/SC 4/WG 4 - External liquid epoxy, resin based coatings epoxy and polyurethane pitches
Standardization of the application and requirements for external coatings obtained by liquid epoxy and liquid polyurethane termosetting resins.
External liquid epoxy, resin based coatings epoxy and polyurethane pitches
Standardization of the application and requirements for external coatings obtained by liquid epoxy and liquid polyurethane termosetting resins.
General Information
Frequently Asked Questions
ECISS/TC 29/SC 4/WG 4 is a Subcommittee within the European Committee for Standardization (CEN). It is named "External liquid epoxy, resin based coatings epoxy and polyurethane pitches" and is responsible for: Standardization of the application and requirements for external coatings obtained by liquid epoxy and liquid polyurethane termosetting resins. This committee has published 2 standards.
ECISS/TC 29/SC 4/WG 4 develops CEN standards. The scope of work includes: Standardization of the application and requirements for external coatings obtained by liquid epoxy and liquid polyurethane termosetting resins. Currently, there are 2 published standards from this subcommittee.
The European Committee for Standardization (CEN) is a public standards organization that brings together the national standardization bodies of 34 European countries. CEN provides a platform for developing European Standards (ENs) and other technical documents in relation to various products, materials, services, and processes, supporting the European Single Market.
A Subcommittee (SC) in CEN operates under a Technical Committee and focuses on a specific subset of the TC's scope. Subcommittees develop standards and technical specifications in their specialized area, reporting to their parent Technical Committee. They may also have working groups for detailed technical work.
The standard defines the reqiurements of liquid applied external coating, epoxy (EP) and epoxy-modified (EP-MOD), for the corrosion protection of tubes and pipeline fittings.
The coating in this standard can be applied to longitudinally or spirally welded and to seamless steel tubes and fittings used for the construction of pipelines for conveying liquids or gases.
If the component has to be cold bent the coating shall be applied after bending unless otherwise approved by the purchaser.
The coating shall consist normally of one layer of liquid product, applied by brush or by spray airless technique. Other application methods can be recommended by the product manufacturer, in accordance with the kind of product.
This coating can be used for the protection of buried or submerged steel tubes for service at the following temperatures and with three thickness classes A (400 *m), B (800 *m) and C(1500 *m) based on the following combination:
- type 1 : - 20 °C to 40 °C, thickness class A or B or C
- type 2 : - 20 °C to 60 °C, thickness class B or C
- type 3 : - 20 °C to 80 °C, thickness class C
Other temperatures can be agreed ; in this case, tests shall be carried out at the required temperature.
In this standard the word components is used for tubes and fittings.
Frequencies of tests on fittings shall be agreed by the parties at the ordering stage.
Components coated with these types of coatings may be further protected by means of cathodic protection.
- Standard41 pagesEnglish languagee-Library read for1 day
The standard defines the requirements of liquid applied external coating, polyurethane (PUR) and polyurethane-modified (PUR-MOD), for the corrosion protection of tubes and pipeline fittings.
The coating in this standard can be applied to longitudinally or spirally welded and to seamless steel tubes and fittings used for the construction of pipelines for conveying liquids or gases.
In accordance with the elongation properties, if the component has to be cold bent the coating shall be applied after bending unless otherwise approved by the purchaser.
The coating shall consist normally of one layer of liquid product, applied by brush or by an airless spray technique.
Other application methods can be recommended by the product manufacturer, in accordance with the kind of product (spatula, injection, spreading, etc.).
This coating can be used for the protection of buried or submerged steel tubes for service at the following temperatures and with two thickness classes A (1000 *m) and B (1500 *m) based on the following combination.
Lower thickness can be agreed between the coating manufacturer and the purchaser.
- type 1 : - 20 °C to 40 °C, thickness class A or B
- type 2 : - 20 °C to 60 °C, thickness class B
- type 3 : - 20 °C to 80 °C, thickness class B
Other temperatures can be agreed; in this case, tests shall be carried out at the required temperature.
In this standard the word components is used for tubes and fittings.
Frequencies of tests on fittings shall be agreed by the parties at the ordering stage.
Components coated with these types of coatings may be further protected by means of cathodic protection.
- Standard44 pagesEnglish languagee-Library read for1 day