Information technology - Data centre facilities and infrastructures - Part 4-2: Power Usage Effectiveness

This Amendment will update EN 50600-4-2 requirements to re-align with the recent findings of JTC 1/SC 39 on this KPI.

Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 4-2: Kennzahl zur eingesetzten Energie

Technologie de l'information - Installation et infrastructures de centres de traitement de données - Partie 4-2 : Efficacité de l'utilisation de l'énergie

Informacijska tehnologija - Naprave in infrastruktura podatkovnih centrov - 4-2. del: Učinkovitost porabe energije - Dopolnilo A1

General Information

Status
Published
Public Enquiry End Date
31-Oct-2018
Publication Date
14-May-2019
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
19-Apr-2019
Due Date
24-Jun-2019
Completion Date
15-May-2019

Relations

Effective Date
01-Jun-2019

Overview

SIST EN 50600-4-2:2017/A1:2019 is an important amendment to the European standard EN 50600-4-2:2016, published by the CLC (European Committee for Electrotechnical Standardization). This standard focuses on the Power Usage Effectiveness (PUE) metric within information technology data centre facilities and infrastructures. The amendment realigns the requirements to incorporate the latest findings from JTC 1/SC 39, ensuring improved accuracy and applicability of the PUE Key Performance Indicator (KPI).

PUE is a critical metric used worldwide to measure energy efficiency in data centres by comparing the total facility energy consumption with the IT equipment energy usage. This update refines measurement techniques, energy consumption calculations, and PUE computation methods to better support sustainable and energy-efficient data centre operations.

Key Topics

  • Energy Consumption Measurement
    The standard mandates metering of gaseous and liquid fuels in kilowatt-hours (kWh), converting the energy based on heat combustion values to ensure consistent reporting. Default values for diesel, natural gas, hydrogen, and bioethanol are provided for use where local data or regulations are absent.

  • Thermal Energy Conversion
    Energy used for cooling via fluids must be measured by heat meters, which record flow rates and temperature differentials. For converting thermal energy to electrical equivalents, suppliers' conversion factors are recommended, with a default value of 0.4 if none is available.

  • IT Load Measurement
    The measurement point for IT power load is standardized at the Power Distribution Unit (PDU) outputs. This ensures accurate, intermediate resolution energy readings that reflect real IT equipment consumption, whether or not transformers are involved.

  • Flexible PUE Calculation Methods
    The amendment introduces detailed annexes showing multiple PUE calculation scenarios, including data centres using different combinations of energy sources like electricity, chilled water, natural gas, cogeneration systems, and absorption type chillers. These examples aid operators in applying standardized calculation methods across diverse infrastructure configurations.

  • Scope and Compliance
    National bodies within CENELEC member countries are required to adopt the amendment as a national standard by January 29, 2020, withdrawing conflicting standards by January 29, 2022. Compliance ensures interoperability and helps unify energy efficiency reporting across European data centres.

Applications

  • Data Centre Energy Efficiency Optimization
    SIST EN 50600-4-2:2017/A1:2019 helps data centre operators accurately monitor and optimize energy consumption, lowering operational costs and reducing environmental impact.

  • Sustainability Reporting
    Utilizing this standard enables transparent and comparable sustainability reports based on standardized PUE metrics, supporting corporate social responsibility and regulatory compliance.

  • Infrastructure Design and Management
    Facilities engineers, architects, and managers use the standard to design and maintain energy-efficient data centre infrastructures, selecting measurement instruments and energy management systems aligned with best practices.

  • Technology Procurement
    Purchasing decisions for cooling systems, power equipment, and energy supply contracts benefit from understanding PUE implications, aiding in choosing solutions with favorable energy usage profiles.

Related Standards

  • EN 50600 Series
    SIST EN 50600-4-2:2017/A1:2019 fits within the broader EN 50600 series covering network infrastructure, security, and environmental criteria for data centres, providing a comprehensive framework for data centre design and operation excellence.

  • JTC 1/SC 39 Guidelines
    This amendment aligns with the latest KPIs developed by the ISO/IEC Joint Technical Committee 1, Subcommittee 39, focusing on energy efficiency metrics for data centres.

  • National and International Energy Standards
    Works alongside standards such as ISO 50001 (Energy Management Systems) and regional regulations targeting data centre energy consumption and carbon footprints.


Keywords: EN 50600-4-2 amendment, Power Usage Effectiveness, PUE metric, data centre energy efficiency, energy consumption measurement, data centre standards, CENELEC, JTC 1/SC 39, thermal energy conversion, data centre infrastructure, sustainable IT facilities, energy performance indicator, cooling systems energy usage.

Amendment

SIST EN 50600-4-2:2017/A1:2019

English language
7 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 50600-4-2:2017/A1:2019 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Information technology - Data centre facilities and infrastructures - Part 4-2: Power Usage Effectiveness". This standard covers: This Amendment will update EN 50600-4-2 requirements to re-align with the recent findings of JTC 1/SC 39 on this KPI.

This Amendment will update EN 50600-4-2 requirements to re-align with the recent findings of JTC 1/SC 39 on this KPI.

SIST EN 50600-4-2:2017/A1:2019 is classified under the following ICS (International Classification for Standards) categories: 35.110 - Networking. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 50600-4-2:2017/A1:2019 has the following relationships with other standards: It is inter standard links to SIST EN 50600-4-2:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 50600-4-2:2017/A1:2019 is associated with the following European legislation: Standardization Mandates: M/462. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 50600-4-2:2017/A1:2019 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2019
Informacijska tehnologija - Naprave in infrastruktura podatkovnih centrov - 4-2.
del: Učinkovitost porabe energije - Dopolnilo A1
Information technology - Data centre facilities and infrastructures - Part 4-2: Power
Usage Effectiveness
Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 4-2:
Kennzahl zur eingesetzten Energie
Technologie de l'information - Installation et infrastructures de centres de traitement de
données - Partie 4-2 : Efficacité de l'utilisation de l'énergie
Ta slovenski standard je istoveten z: EN 50600-4-2:2016/A1:2019
ICS:
35.110 Omreževanje Networking
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 50600-4-2:2016/A1

NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2019
ICS 35.020; 35.110; 35.160
English Version
Information technology - Data centre facilities and infrastructures
- Part 4-2: Power Usage Effectiveness
Technologie de l'information - Installation et infrastructures Informationstechnik - Einrichtungen und Infrastrukturen von
de centres de traitement de données - Partie 4-2 : Efficacité Rechenzentren - Teil 4-2: Kennzahl zur eingesetzten
de l'utilisation de l'énergie Energie
This amendment A1 modifies the European Standard EN 50600-4-2:2016; it was approved by CENELEC on 2019-01-29. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50600-4-2:2016/A1:2019 E

Contents
European foreword . 3
1 Modification to the Introduction . 4
2 Modification to 5.2, Total data centre energy consumption . 4
3 Modification to 6.2.3, Category 2 (PUE2) – intermediate resolution . 5
4 Modification to Annex B, Calculation of PUE using various energy supplies. 5