SIST EN 60061-3:2000/A1:1999
(Amendment)Lamp caps and holders together with gauges for the control of interchangeability and safety -- Part 3: Gauges
Lamp caps and holders together with gauges for the control of interchangeability and safety -- Part 3: Gauges
Subscribe to IEC 60061 Database to access the full and updated content of the series.
Lampensockel und -fassungen sowie Lehren zur Kontrolle der Austauschbarkeit und Sicherheit -- Teil 3: Lehren
Culots de lampes et douilles ainsi que calibres pour le contrôle de l'interchangeabilité et de la sécurité -- Partie 3: Calibres
Subscribe to IEC 60061 Database to access the full and updated content of the series.
Vznožki in okovi žarnic in sijalk skupaj s kalibri za kontrolo medsebojne zamenljivosti in varnosti – 3. del: Kalibri (IEC 60061-3N:1994)
General Information
- Status
- Published
- Publication Date
- 30-Jun-1999
- Technical Committee
- IESV - Lamps and related equipment
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Jul-1999
- Due Date
- 01-Jul-1999
- Completion Date
- 01-Jul-1999
Relations
- Effective Date
- 01-Jul-1999
Overview
EN 60061-3:1993/A1:1995 (CLC) - "Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges" is a harmonized European adoption of the IEC 60061 Part 3 document. This Part focuses on the gauges used to verify the mechanical interchangeability and safety of lamp caps and lamp holders. The full and updated content of the EN/IEC 60061 series is available via subscription to the IEC 60061 Database.
Key topics
- Scope and purpose: Establishes the role of gauges as control tools for ensuring lamps and holders meet interchangeability and safety intent of the EN/IEC 60061 series.
- Types of gauges: Defines categories of gauges used for dimensional and functional checks (note: for detailed gauge types and drawings see the official IEC/EN document).
- Usage and test principles: Describes how gauges are applied to check lamp caps and holders for correct fit, retention and basic safety aspects.
- Marking and identification: Requirements for marking gauges and traceability so measurement and compliance are auditable.
- Calibration and maintenance: Guidance on calibration intervals and maintenance practices to keep gauges reliable for quality control.
- Reference to series: Integrates with other parts of the EN/IEC 60061 series that cover lamp cap dimensions, holder requirements and safety performance.
Applications
EN 60061-3 is practical for organizations involved in lighting component production, testing and compliance:
- Lamp and lamp cap manufacturers - for production inspection and final acceptance checks.
- Lamp holder and luminaire manufacturers - to ensure correct mating, retention and safe operation.
- Testing and calibration laboratories - to apply standardized gauge methods when verifying conformity.
- Quality assurance teams - for incoming inspection, statistical process control and supplier audits.
- Regulatory bodies and market surveillance - to assess interchangeability and safety claims.
- Importers and distributors - to confirm products conform to EU/CENELEC expectations before market placement.
Related standards
- EN/IEC 60061 series (other parts covering dimensions, definitions and safety requirements)
- National adoptions and amendments (e.g., SIST EN 60061-3:2000/A1:1999 as a Slovenian national standard)
For exact gauge dimensions, drawings, tolerances and test procedures consult the complete EN/IEC 60061 Part 3 text available through the IEC 60061 Database or your national standards body.
Frequently Asked Questions
SIST EN 60061-3:2000/A1:1999 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Lamp caps and holders together with gauges for the control of interchangeability and safety -- Part 3: Gauges". This standard covers: Subscribe to <a href="http://webstore.iec.ch/webstore/webstore.nsf/Artnum_PK/34192?opendocument">IEC 60061 Database to access the full and updated content of the series.
Subscribe to <a href="http://webstore.iec.ch/webstore/webstore.nsf/Artnum_PK/34192?opendocument">IEC 60061 Database to access the full and updated content of the series.
SIST EN 60061-3:2000/A1:1999 is classified under the following ICS (International Classification for Standards) categories: 29.140.10 - Lamp caps and holders. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 60061-3:2000/A1:1999 has the following relationships with other standards: It is inter standard links to SIST EN 60061-3:2000. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 60061-3:2000/A1:1999 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 60061-3:2000/A1:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-1999
Vznožki in okovi žarnic in sijalk skupaj s kalibri za kontrolo medsebojne
zamenljivosti in varnosti – 3. del: Kalibri (IEC 60061-3N:1994)
Lamp caps and holders together with gauges for the control of interchangeability and
safety -- Part 3: Gauges
Lampensockel und -fassungen sowie Lehren zur Kontrolle der Austauschbarkeit und
Sicherheit -- Teil 3: Lehren
Culots de lampes et douilles ainsi que calibres pour le contrôle de l'interchangeabilité et
de la sécurité -- Partie 3: Calibres
Ta slovenski standard je istoveten z: EN 60061-3:1993/A1:1995
ICS:
29.140.10 Grla in držala žarnic Lamp caps and holders
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
SIST EN 60061-3:2000/A1:199
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...