SIST EN 50382-1:2008
Railway applications - Railway rolling stock high temperature power cables having special fire performance -- Part 1: General requirements
- Abstract
This Part 1 of EN 50382 specifies the general requirements applicable to the cables given in EN 50382-2. It includes the detailed requirements for the insulating and sheathing materials and other components called up in EN 50382-2. In particular EN 50382-1 specifies those requirements relating to fire safety. Based on proven experience and reliability over many years these cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a conductor temperature of either 120 °C or 150 °C. NOTE This rating is based upon the polymer defined in 3.1. Before this polymer had gained widespread acceptance in the cable industry, ageing performance had been assessed via long term thermal endurance testing and had been extrapolated to 20 000 h using techniques equivalent to those in EN 60216. Subsequent experience in service has demonstrated that the predicted performance levels were correct. Where extrapolated data is used to predict lifetime in service it should be confirmed with the cable manufacturer, and should be based on a failure mode appropriate to the type of material or cable. The maximum temperature for short circuit conditions for silicone rubber is 350 °C based on a duration of 5 s. Although both of the insulating and one of the sheathing compounds specified in this standard are thermally capable of operating at 150 °C, where tinned conductors are used the maximum operating temperature is limited to 120 °C and for the same technical reason the maximum short circuit temperature, for tinned copper conductors, is limited to 250 °C. The choice of sheath may also limit the operating temperature to 120 °C. This Part 1 should be used in conjunction with EN 50382-2.
- Status
- Published
- Publication Date
- 27-Apr-2008
- Technical Committee
- IEKA - Electric cables
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 08-Apr-2008
- Due Date
- 13-Jun-2008
- Completion Date
- 28-Apr-2008
SIST EN 50382-1:2008 is the Slovenian adoption of EN 50382-1:2008 for railway applications. It specifies the general requirements for high temperature power cables for railway rolling stock with special fire performance, including fire-safety, construction, marking and test-related requirements. The standard is meant to be used together with EN 50382-2, which gives the specific cable types.
What does SIST EN 50382-1:2008 specify?
SIST EN 50382-1:2008 sets the general rules for the cables defined in EN 50382-2. It covers the insulating and sheathing materials, other cable components, and the fire-safety requirements that matter most in railway rolling stock.
The standard applies to cables designed for occasional thermal stress equivalent to long-term service at conductor temperatures of 120 °C or 150 °C. It also gives limits for short-circuit conditions and notes that tinned conductors can reduce the permitted operating and short-circuit temperatures.
The document is organized into:
- Scope, normative references and definitions
- Rated voltage
- Marking
- Construction requirements
- Electrical performance
- Reaction to fire for cables and components
- Normative annexes for halogens and measurement methods
- An informative annex for type-approval selection
| Annex | What it covers |
|---|---|
| Annex A | Requirements for halogens in extruded and non-extruded materials |
| Annex B | Elemental test method for determining halogens |
| Annex C | Sampling and calculation for insulation thickness, sheath thickness and overall diameter |
| Annex D | Guidance on selecting cables for type approval |
What are the key requirements of SIST EN 50382-1:2008?
Rated voltage and temperature limits
SIST EN 50382-1:2008 defines the rated voltage in the usual railway format and recognizes two voltage ratings for these cables: 1 800/3 000/3 600 V and 3 600/6 000/7 200 V. In alternating-current systems, the rated voltage must be at least the system nominal voltage.
For direct-current systems, the maximum voltage to earth must not exceed 1.5 times the rated voltage. In practice, this means the cable rating has to match both the electrical system and the way railway equipment is identified in service.
The scope also states that silicone rubber cables are rated for short-circuit conditions of 350 °C for 5 s. It also notes that tinned conductors limit service temperature to 120 °C and, for the same reason, limit short-circuit temperature for tinned copper conductors to 250 °C.
Marking and identification
Clause 5 requires continuous identification of origin by the manufacturer’s name, trademark or registered identification number. The marking may be printed tape, printing, indenting or embossing on the sheath, or printing on the outer surface.
The marks must remain legible and durable, and the standard defines how far apart repeated markings may be. For a buyer or inspector, this means the cable can be traced back to its maker and checked in the field after installation.
Cable construction
Clause 6 requires tin-coated or plain annealed copper conductors, with conductor construction to EN 60228 and conductor resistance to the relevant class in that standard. Insulation and sheath materials are tied to the compound types defined in the standard, and the insulation and sheath are applied by extrusion to form a smooth, closely fitting body.
The insulation and sheath thicknesses, and the overall diameter, must stay within the limits given for each cable type and size. Annex C gives the sampling and calculation method, so users know how conformity is checked rather than relying on visual judgment alone.
Fire performance and material safety
Clause 8 sets the cable reaction-to-fire checks. Single cables are tested for vertical flame propagation to EN 60332-1-2, bunched cables of different diameters are tested to EN 50266-2-4 or EN 50266-2-5, and smoke emission is checked to EN 61034-2 with a minimum light transmission requirement.
Clause 9 and Annex A require halogen assessment on insulation, sheath and applicable fillers and tapes. The standard also limits toxicity by reference to EN 50305 and uses the toxicity index (ITC) approach for the whole cable when non-extruded elements are present. In practice, these requirements are there to limit corrosive gases, smoke and toxic effects in a train fire.
Material requirements for insulating and sheathing compounds
Tables 2 and 3 define the compound types used in EN 50382-2. For insulation, the standard covers EI 111 and EI 112; for sheaths, it covers EM 105, EM 106 and EM 107.
These tables combine mechanical tests, ageing, hot set, ozone resistance, mineral oil resistance, low-temperature behaviour, halogen content and toxicity. For a manufacturer, this means the material has to pass both electrical and environmental checks before it can be used in the cable design.
What terms does SIST EN 50382-1:2008 define?
- Cross-linked silicone rubber (SiR) - A poly-siloxane based compound that has been cross-linked and meets the relevant specification requirements.
- Cross-linked ethylene copolymers - A compound based on an ethylene copolymer such as EVA that has been cross-linked and meets the relevant specification requirements.
- Type of compound - A category assigned by one or more properties measured in specific tests, not simply by chemical recipe.
- Halogen-free material - A combustible material that complies with Annexes A and B.
- Type tests (T) - Tests performed before a cable type is placed on the market to show that the design performs as intended.
- Sample tests (S) - Tests performed on finished cable samples or components to confirm the product matches the design specification.
- Routine tests (R) - Tests performed on every complete cable length to show integrity.
- Toxicity index (ITC) - The value used to assess toxicity performance of cable materials and, where needed, the whole cable.
Who uses SIST EN 50382-1:2008?
SIST EN 50382-1:2008 is used by cable manufacturers, test laboratories, railway rolling stock designers, approval bodies, quality managers and buyers who specify cables for trains and other rolling stock. It is relevant to anyone selecting, testing, approving or receiving high-temperature power cables for railway use.
In practice, these users rely on it to choose the right cable construction, verify fire performance, check halogen and toxicity performance, and set up type approval or production control.
Which standards are used with SIST EN 50382-1:2008?
- EN 50382-2 - Gives the specific cable types covered by this general part.
- EN 50305 - Supplies special test methods used for resistance, durability, ageing and toxicity-related checks.
- EN 60228 - Defines conductor construction and resistance classes.
- EN 60332-1-2 - Provides the single-cable vertical flame propagation test.
- EN 50266-2-4 and EN 50266-2-5 - Provide the bunched-cable flame spread tests for the diameter ranges used here.
- EN 61034-2 - Provides the smoke density test for burning cables.
- EN 50267-2-1 and EN 50267-2-2 - Provide the gas and acidity methods used for halogen assessment.
- EN 60684-2 - Provides the fluorine-content method used in halogen testing.
- EN 60811-1-1, EN 60811-1-2, EN 60811-1-3, EN 60811-1-4 and EN 60811-2-1 - Provide the common material test methods used for thickness, ageing, low temperature, hot set, water absorption and mineral oil resistance.
- EN 10002-1 - Provides the tensile test method for conductor wire elongation.
- EN 50343 and EN 50355 - Are named in the introduction as guides for cable selection, installation and current ratings.
What does the SIST EN 50382-1:2008 document contain?
The standard contains a table of rated voltages, marking rules with an example figure, and construction requirements for conductors, insulation, sheaths, tapes and non-metallic components. It also includes compound requirement tables for EI 111, EI 112, EM 105, EM 106 and EM 107.
Its annexes provide the practical test content: Annex A sets the halogen requirements, Annex B gives the sodium-fusion elemental test, and Annex C explains how to sample and calculate thickness and diameter results. Annex D gives a cable-selection guide for type approval, which is useful when planning qualification testing for a family of railway cables.
Relations
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Refers
SIST EN IEC 60684-2:2025 - Flexible insulating sleeving - Part 2: Methods of test (IEC 60684-2:2025) - Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.
IRIS Certification (UNIFE)
International Railway Industry Standard certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.
Sponsored listings
Frequently Asked Questions
SIST EN 50382-1:2008 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Railway applications - Railway rolling stock high temperature power cables having special fire performance -- Part 1: General requirements". This standard covers: This Part 1 of EN 50382 specifies the general requirements applicable to the cables given in EN 50382-2. It includes the detailed requirements for the insulating and sheathing materials and other components called up in EN 50382-2. In particular EN 50382-1 specifies those requirements relating to fire safety. Based on proven experience and reliability over many years these cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a conductor temperature of either 120 °C or 150 °C. NOTE This rating is based upon the polymer defined in 3.1. Before this polymer had gained widespread acceptance in the cable industry, ageing performance had been assessed via long term thermal endurance testing and had been extrapolated to 20 000 h using techniques equivalent to those in EN 60216. Subsequent experience in service has demonstrated that the predicted performance levels were correct. Where extrapolated data is used to predict lifetime in service it should be confirmed with the cable manufacturer, and should be based on a failure mode appropriate to the type of material or cable. The maximum temperature for short circuit conditions for silicone rubber is 350 °C based on a duration of 5 s. Although both of the insulating and one of the sheathing compounds specified in this standard are thermally capable of operating at 150 °C, where tinned conductors are used the maximum operating temperature is limited to 120 °C and for the same technical reason the maximum short circuit temperature, for tinned copper conductors, is limited to 250 °C. The choice of sheath may also limit the operating temperature to 120 °C. This Part 1 should be used in conjunction with EN 50382-2.
This Part 1 of EN 50382 specifies the general requirements applicable to the cables given in EN 50382-2. It includes the detailed requirements for the insulating and sheathing materials and other components called up in EN 50382-2. In particular EN 50382-1 specifies those requirements relating to fire safety. Based on proven experience and reliability over many years these cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a conductor temperature of either 120 °C or 150 °C. NOTE This rating is based upon the polymer defined in 3.1. Before this polymer had gained widespread acceptance in the cable industry, ageing performance had been assessed via long term thermal endurance testing and had been extrapolated to 20 000 h using techniques equivalent to those in EN 60216. Subsequent experience in service has demonstrated that the predicted performance levels were correct. Where extrapolated data is used to predict lifetime in service it should be confirmed with the cable manufacturer, and should be based on a failure mode appropriate to the type of material or cable. The maximum temperature for short circuit conditions for silicone rubber is 350 °C based on a duration of 5 s. Although both of the insulating and one of the sheathing compounds specified in this standard are thermally capable of operating at 150 °C, where tinned conductors are used the maximum operating temperature is limited to 120 °C and for the same technical reason the maximum short circuit temperature, for tinned copper conductors, is limited to 250 °C. The choice of sheath may also limit the operating temperature to 120 °C. This Part 1 should be used in conjunction with EN 50382-2.
SIST EN 50382-1:2008 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products; 29.060.20 - Cables; 45.060.01 - Railway rolling stock in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 50382-1:2008 has the following relationships with other standards: It is inter standard links to SIST EN 60811-1-4:1999, SIST EN IEC 60228:2024, SIST EN IEC 60332-3-25:2018, SIST EN IEC 60332-3-24:2018, SIST EN 50267-2-1:1999, SIST EN 60332-1-2:2005, SIST EN 60811-1-2:1999, SIST EN 50267-2-2:1999, SIST EN IEC 60684-2:2025, SIST EN 60811-1-1:1999, SIST EN 61034-2:2005, SIST EN 60811-1-3:1999, SIST EN 60811-2-1:2000, SIST EN 45545-2:2020, SIST EN 45545-2:2013. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 50382-1:2008 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-2008
äHOH]QLãNHQDSUDYH9LVRNRWHPSHUDWXUQLPRþQRVWQLNDEOL]DåHOH]QLãNDYR]QD
VUHGVWYDNLLPDMRSRVHEQHSRåDUQHODVWQRVWLGHO6SORãQH]DKWHYH
Railway applications - High temperature power cables for railway rolling stock and having
special fire performance - Part 1: General requirements
Bahnanwendungen - Hochtemperaturkabel und -leitungen für Schienenfahrzeuge mit
verbessertem Verhalten im Brandfall - Teil 1: Allgemeine Anforderungen
Applications ferroviaires - Câbles pour matériel roulant ferroviaire ayant des
performances particulières de comportement au feu - Partie 1: Prescriptions générales
Ta slovenski standard je istoveten z: EN 50382-1:2008
ICS:
13.220.40 Sposobnost vžiga in Ignitability and burning
obnašanje materialov in behaviour of materials and
proizvodov pri gorenju products
29.060.20 Kabli Cables
45.060.01 Železniška vozila na splošno Railway rolling stock in
general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 50382-1
NORME EUROPÉENNE
March 2008
EUROPÄISCHE NORM
ICS 13.220.40; 29.060.20; 45.060.01
English version
Railway applications -
Railway rolling stock high temperature power cables
having special fire performance -
Part 1: General requirements
Applications ferroviaires - Bahnanwendungen -
Câbles pour matériel roulant ferroviaire Hochtemperaturkabel und -leitungen
ayant des performances particulières für Schienenfahrzeuge mit verbessertem
de comportement au feu - Verhalten im Brandfall -
Partie 1: Prescriptions générales Teil 1: Allgemeine Anforderungen
This European Standard was approved by CENELEC on 2008-02-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50382-1:2008 E
Foreword
This European Standard was prepared for the Technical Committee CENELEC TC 20, Electric cables, by
Working Group 12, Railway Cables, as part of the overall programme of work in the Technical Committee
CENELEC TC 9X, Electrical and electronic applications for railways.
The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50382-1 on
2008-02-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2009-02-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2011-02-01
––––––––––––
– 3 – EN 50382-1:2008
Contents
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Definitions . 6
4 Rated voltage . 7
5 M arking . 8
5.1 Indication of origin . 8
5.2 Continuity of marks . 8
5.3 Durability . 8
5.4 Legibility . 9
5.5 Additional marking. 9
5.6 Use of the name CENELEC . 9
6 General requirements for the construction of cables . 9
6.1 Conductors . 9
6.2 Insulation system . 10
6.3 Tapes . 10
6.4 Sheath . 11
6.5 Overall diameter . 11
6.6 Non-metallic components . 11
7 Electrical performance . 12
8 Reaction to fire – Cables . 12
8.1 Flame propagation (flame spread) – Single vertical cable . 12
8.2 Flame propagation (flame spread) – Bunched cables . 12
8.3 Smoke emi s s i on . 12
9 Reaction to fire – Components . 12
9.1 Assessment of halogens . 12
9.2 Toxicity . 12
Annex A (normative) Requirements for halogens . 19
Annex B (normative) Determination of halogens – Elemental test . 21
Annex C (normative) Thickness and overall diameter – Selection of samples and
calculation of results . 23
Annex D (informative) Guidance on selection of cables for type approval . 24
Bibliography . 25
Figures
Figure 1 – Example of marking . 8
Tables
Table 1 – Rated voltages . 8
Table 2 – Requirements for the tests for halogen free insulating compounds for Part 2 . 13
Table 3 – Requirements for the tests for halogen free sheathing compounds for Part 2 . 16
Table A.1 – Type test . 19
Table A.2 – Sample test . 19
Table D.1 – Selection of cables for type approval . 24
Introduction
The railway industry is generally concerned with the movement of people as well as goods. It is therefore
essential that a high level of safety is achieved, even when failures occur which may involve fire, howsoever
caused, affecting railway rolling stock.
Hence it is necessary to provide cables for use in railway environments which minimise the hazard to people
when a fire may damage the cable, irrespective of whether the fire is caused by an external source or from
within the electrical system.
EN 50382 specifies cables for power and associated circuits which, in the event of fire, will limit the risk to
people and improve the safety on railways in general. It covers cables, for use in railway rolling stock, and
having standard wall thickness of insulation, based on materials that allow them to operate at high
temperature and which are also halogen free. In the event of a fire affecting cables to EN 50382 they will
have a limited flame spread and limited emission of toxic gases. In addition these cables when burnt produce
limited amounts of smoke. This last characteristic will minimise loss of visibility in the event of a fire and will
aid reduced evacuation times.
The objects of this standard are
– to standardise cables that are safe and reliable when properly used,
– to state the characteristics, performance, and construction requirements directly or indirectly bearing on
safety,
– to specify methods for checking conformity with these requirements.
EN 50382, which covers a range of cables rated at up to 3,6/6 kV with conductor sizes 1,5 mm² up to
400 mm², is divided into 2 parts:
– Part 1: General requirements;
– Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C.
These cables are intended for a limited number of applications.
Information regarding selection and installation of cables including current ratings can be found in EN 50355
and EN 50343. The procedure for selection of cable cross-sectional area, including reduction factors for
ambient temperature and installation type, are described in EN 50343.
NOTE Current ratings for inclusion in EN 50355 are under development for the next amendment.
Special test methods referred to in EN 50382 are given in EN 50305.
– 5 – EN 50382-1:2008
1 Scope
This Part 1 of EN 50382 specifies the general requirements applicable to the cables given in EN 50382-2. It
includes the detailed requirements for the insulating and sheathing materials and other components called up
in EN 50382-2. In particular EN 50382-1 specifies those requirements relating to fire safety.
Based on proven experience and reliability over many years these cables are rated for occasional thermal
stresses causing ageing equivalent to continuous operational life at a conductor temperature of either 120 °C
or 150 °C.
NOTE This rating is based upon the polymer defined in 3.1. Before this polymer had gained widespread acceptance in the cable
industry, ageing performance had been assessed via long term thermal endurance testing and had been extrapolated to 20 000 h using
techniques equivalent to those in EN 60216. Subsequent experience in service has demonstrated that the predicted performance levels
were correct.
Where extrapolated data is used to predict lifetime in service it should be confirmed with the cable manufacturer, and should be based
on a failure mode appropriate to the type of material or cable.
The maximum temperature for short circuit conditions for silicone rubber is 350 °C based on a duration of 5 s.
Although both of the insulating and one of the sheathing compounds specified in this standard are thermally
capable of operating at 150 °C, where tinned conductors are used the maximum operating temperature is
limited to 120 °C and for the same technical reason the maximum short circuit temperature, for tinned copper
conductors, is limited to 250 °C. The choice of sheath may also limit the operating temperature to 120 °C.
This Part 1 should be used in conjunction with EN 50382-2.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 10002-1 Metallic materials – Tensile testing – Part 1: Method of test (at ambient
temperature)
EN 50266-2-4 Common test methods for cables under fire conditions – Test for vertical
flame spread of vertically-mounted bunched wires or cables – Part 2-4:
Procedures – Category C
EN 50266-2-5 Common test methods for cables under fire conditions – Test for vertical
flame spread of vertically-mounted bunched wires or cables – Part 2-5:
Procedures – Small cables – Category D
EN 50267-2-1 Common test methods for cables under fire conditions – Tests on gases
evolved during combustion of materials from cables – Part 2–1: Procedures –
Determination of the amount of halogen acid gas
EN 50267-2-2 Common test methods for cables under fire conditions – Tests on gases
evolved during combustion of materials from cables – Part 2–2: Procedures –
Determination of degree of acidity of gases for materials by measuring pH
and conductivity
EN 50305:2002 Railway applications – Railway rolling stock cables having special fire
performance – Test methods
EN 50382-2 Railway applications – Railway rolling stock high temperature power cables
having special fire performance – Part 2: Single core silicone rubber insulated
cables for 120 °C or 150 °C
EN 60228 Conductors of insulated cables (IEC 60228)
EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions – Part 1-2: Test
for vertical flame propagation for a single insulated wire or cable – Procedure
for 1 kW pre-mixed flame (IEC 60332-1-2)
EN 60684-2 Flexible insulating sleeving – Part 2: Methods of test (IEC 60684-2)
EN 60811-1-1:1995 Insulating and sheathing materials of electric and optical cables – Common
test methods – Part 1-1: General application – Measurement of thickness and
overall dimensions – Tests for determining the mechanical properties
(IEC 60811-1-1:1993)
EN 60811-1-2:1995 Insulating and sheathing materials of electric cables – Common
test methods – Part 1–2: General application – Thermal ageing methods
(IEC 60811-1-2:1985 + A1:1989 + corr. May 1986)
EN 60811-1-3:1995 Insulating and sheathing materials of electric and optical cables – Common
test methods – Part 1-3: General application – Methods for determining the
density – Water absorption tests – Shrinkage test (IEC 60811-1-3:1993)
EN 60811-1-4:1995 Insulating and sheathing materials of electric and optical cables – Common
test methods – Part 1–4: General application – Tests at low temperature
(IEC 60811-1-4:1985 + A1:1993 + corr. May 1986)
EN 60811-2-1:1998 Insulating and sheathing materials of electric and optical cables – Common
test methods – Part 2–1: Methods specific to elastomeric compounds –
Ozone resistance, hot set and mineral oil immersion tests
(IEC 60811-2-1:1998)
EN 61034-2 Measurement of smoke density of cables burning under defined conditions –
Part 2: Procedure and requirements (IEC 61034-2)
3 Definitions
For the purposes of all parts of EN 50382, the following terms and definitions apply. The types or combination
of insulating and sheathing compounds covered in this EN are listed below.
3.1
cross-linked silicone rubber (SiR)
compound based on a poly-siloxane polymer which, when cross-linked, meets with the requirements given in
the particular specification
3.2
cross-linked ethylene copolymers
compound in which the characteristic constituent is a copolymer of ethylene such as EVA or other, which,
when cross-linked, complies with the requirements given in the particular specifications
3.3
type of compound
category, designated by one or several characteristics, in which a compound is placed according to its
properties, as determined by specific tests
NOTE The type designation is not directly related to the composition of the compound. See also 6.2.1 and 6.4.1.
3.4
halogen-free material
combustible material which complies with the requirements of Annexes A and B
– 7 – EN 50382-1:2008
3.5
variation
difference between the median value after treatment and the median value without treatment, expressed as a
percentage of the latter
3.6
type tests (symbol T)
tests required to be made before supplying a type of cable covered by this standard on a general commercial
basis in order to demonstrate satisfactory performance characteristics to meet the intended application
NOTE These tests are of such a nature that, after they have been made, they need not be repeated unless changes are made in the
cable materials, design or type of manufacturing process which might change the performance characteristics.
3.7
sample tests (symbol S)
tests made on samples of completed cable, or components taken from a completed cable adequate to verify
that the finished product meets the design specification
3.8
routine tests (symbol R)
tests made on all complete cable lengths to demonstrate their integrity
4 Rated voltage
The rated voltage of a cable is the reference voltage for which the cable is designed, and which serves to
define the electrical tests.
The rated voltage V is expressed by the combination of the following values (in volts):
U /U (U )
o m
where
U is the r.m.s. value between any insulated conductor and earth, i.e. metal covering of the cable or the
surrounding medium, e.g. U = 1 800 V;
U is the r.m.s. value between any two phase-conductors of a multicore cable or of a system of single-
core cables, e.g. U = 3 000 V;
U is the maximum r.m.s. value of the "highest system voltage" for which the equipment may be used,
m
e.g. U = 3 600 V.
m
In an alternating current system, the rated voltage of a cable shall be at least equal to the nominal voltage of
the system for which it is intended.
In a direct current system, the cables shall have a maximum voltage against earth (V ) not exceeding
1,5 times the rated voltage (U ) of the cable, where
V is the d.c. value between any insulated conductor and earth, i.e. metal covering of the cable or the
surrounding medium, e.g. V = 2 700 V.
The rated voltage recognized for the purposes of all parts of EN 50382 shall be as given in Table 1.
NOTE In the railway industry it is common practice to identify cables and systems by the value of U , not the more usual practice of U.
o
Table 1 – Rated voltages
Rated voltage
V
U U U V
o m o
1 800 3 000 3 600 2 700
3 600 6 000 7 200 5 400
NOTE See Guide to use (EN 50355) for further information.
5 Marking
5.1 Indication of origin
Cables shall be provided with an identification of origin consisting of the continuous marking of the
manufacturer’s name, trademark, or registered identification number, by one of the following methods:
1) a printed tape within the cable;
2) printing, indenting or embossing on the outer surface of sheathed cable;
3) printing on the outer surface of the cable.
NOTE Additional markings may be specified in EN 50382-2.
5.2 Continuity of marks
Each specified mark shall be regarded as continuous if the distance between the end of the mark and the
beginning of the next identical mark does not exceed
a) 550 mm if the marking is on the outer surface of the cable,
b) 275 mm if the marking is on the insulation or on a tape.
NOTE 1 A "specified mark" is any mandatory mark covered by this Part of EN 50382 or by the particular requirements of Part 2.
NOTE 2 An example of marking on the outer surface of the cable is given in Figure 1.
Figure 1 – Example of marking
Compliance shall be checked by visual examination and measurement.
5.3 Durability
Printed markings shall be durable.
Compliance shall be checked by the test given in EN 50305, 10.1.
– 9 – EN 50382-1:2008
5.4 Legibility
All markings shall be legible.
Printed markings shall be in contrasting colours.
5.5 Additional marking
Additional marking, specific to the individual cable type, shall be given in EN 50382-2.
5.6 Use of the name CENELEC
The name CENELEC, in full or abbreviated, shall not be directly marked on, or in, the cables.
6 General requirements for the construction of cables
6.1 Conductors
6.1.1 Material
The conductors shall be tin coated or plain annealed copper.
When tested in accordance with EN 10002-1 the minimum average elongation of wires from the conductors
shall be 15 %, with a minimum value of 10 % for an individual wire.
6.1.2 Construction
Conductors shall be in accordance with EN 60228.
NOTE The classes of the conductors relevant to the various types of cables are given in EN 50382-2.
6.1.3 Check of construction
Conformity with the requirements of 6.1.1 and 6.1.2 shall be checked by inspection and by measurement.
6.1.4 Electrical resistance
The resistance of each conductor at 20 °C shall be in accordance with the requirements of EN 60228 for the
given class of conductor.
Compliance shall be checked by the test given in EN 50305, 6.1.
6.1.5 Separator tape
It is permitted to place a non-hygroscopic separator tape of coloured material between the conductor and
insulation. If used, the separator tape shall be easily removable from the conductor.
6.1.6 Conductor screening
Where specified in EN 50382-2 the conductor screening shall consist of a semiconducting tape, a layer of
extruded semi-conducting compound, or a combination of both.
It shall be easily removable from the conductor.
6.2 Insulation system
6.2.1 Material
The insulation system shall be manufactured from materials as defined in 3.1 of this part. It shall conform to
the requirements given in Table 2 and as specified for each type of cable in EN 50382-2.
Insulation types available are
a) for unsheathed cables:
– Type EI 111: extra low temperature resistant, oil resistant;
b) for sheathed cables:
– Type EI 111: extra low temperature resistant, oil resistant;
– Type EI 112: extra low temperature resistant.
NOTE Compound Type EI 112 is not oil resistant.
6.2.2 Application
The insulation sy
...