Abstract

This document describes an analytical procedure for the determination of platinum in platinum alloys with a nominal content up to 990 ‰ (parts per thousand), including alloys according to ISO 9202.

Status
Not Published
Public Enquiry End Date
14-Oct-2026
Technical Committee
I13 - Imaginarni 13
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
12-Aug-2026
Due Date
30-Dec-2026
Completion Date
16-Oct-2026

Buy Documents

Draft

oSIST prEN ISO 11494:2026

English language (15 pages)
Preview
Preview
e-Library read for
×1 day

oSIST prEN ISO 11494:2026 is a SIST standard for determining platinum in homogeneous platinum alloys by inductively coupled argon plasma optical emission spectrometer (ICP-OES) with an internal standard element. It specifies an analytical procedure for platinum alloys with nominal platinum content up to 990 ‰ by mass, including alloys according to ISO 9202. It is written for laboratories that need a repeatable assay method for jewellery and precious metals.

What does oSIST prEN ISO 11494:2026 specify?

oSIST prEN ISO 11494:2026 specifies the scope, the analytical principle, the working materials and the calculation route for platinum determination in platinum alloys. It is organized into Clauses 1 to 10, followed by two informative annexes.

The method applies to homogeneous material and prefers samples with platinum content between 50 ‰ and 990 ‰ by mass. Platinum above 990.0 ‰ by mass is handled by ISO 15093, while lower contents can also be analysed by referring to this method.

AnnexWhat it covers
Annex ATechnical background for ICP-OES
Annex BInterlaboratory testing

What are the key requirements of oSIST prEN ISO 11494:2026?

oSIST prEN ISO 11494:2026 requires a controlled ICP-OES procedure with internal standardization, bracketing calibration, and duplicate sample preparation. In practice, the method depends on clean reagents, matched matrices, stable instrument settings, and calculation from intensity ratios.

  • Principle, Clause 4 - At least two accurately weighed samples are dissolved in aqua regia, brought to exact mass, mixed with an internal standard, and measured by ICP-OES against calibration solutions. This means the analyst works from prepared solutions, not direct solid measurement, and must keep the calibration and sample treatment aligned.
  • Reagents, Clause 5 - Reagents must be of recognized analytical grade, water must be distilled or equivalent, and all reagents except platinum must be platinum free. This matters because trace contamination can bias a precious-metal assay.
  • Internal standard and matrix control, Clauses 5 and 8.1 - The internal standard solution uses elements such as Yttrium, Scandium, Indium, Germanium or Lutetium, and the chosen element must not be present in the alloy. This reduces drift and matrix effects, so the signal ratio remains meaningful.
  • Equipment, Clause 6 - The ICP-OES must measure platinum and internal standard lines simultaneously with at least 0.02 nm optical resolution, and the balance must read to 0.01 mg. Clean vessels and argon of purity at least 99.995 % are required. That level of control supports traceable weighing and stable plasma conditions.
  • Sampling and sample solutions, Clauses 7 and 8.3 - Sampling follows ISO 11596, and each sample is prepared as two test sample solutions. The document also calls for consistent acid concentration between calibration and sample solutions. That consistency is important because mismatched chemistry can change the measured signal.
  • Special alloy handling, Clause 8.3.1 - Alloys containing more than 5 % ruthenium, iridium or tungsten may need pressure dissolution or a preliminary alloying stage with platinum-free copper, and tungsten requires orthophosphoric acid. This is the part the laboratory uses when the alloy composition makes ordinary dissolution unreliable.
  • Measurement and quality checks, Clause 8.4 - A preliminary calibration uses three standards to check linearity, with a regression coefficient greater than 0.9999, and bracketing then runs low standard - sample - high standard in cycles. Each solution needs at least 60 s stabilization, at least 15 s integration, and at least three integrations, with RSD not larger than 0.3 %.
  • Calculation, repeatability and reporting, Clause 9 and 10 - Results are calculated from corrected intensity quotients and the actual platinum mass in the standards; other algorithms must be validated. Duplicate determinations must differ by less than 3 ‰ by mass, and the test report must identify the sample, sampling, method reference, result, deviations, unusual features, date, laboratory, manager and operator signatures.

What terms does oSIST prEN ISO 11494:2026 define?

oSIST prEN ISO 11494:2026 defines the key terms used in the procedure so that laboratories read the method in the same way.

  • calibration solution - A solution used to calibrate the instrument, prepared from a stock solution or from certified reference material with added acids, buffer, reference elements and salts as needed.
  • bracketing - A measurement approach where the sample signal is placed between two calibration solutions of neighboring concentrations in the working range.
  • laboratory sample - The sample intended for laboratory inspection or testing.
  • test portion - The portion taken from the laboratory sample for analysis after suitable pretreatment.
  • test sample solution - The solution prepared after extraction or digestion of the test sample.
  • internal standard - A compound added in fixed amount to correct for instrument drift and matrix interference.
  • linearity - A straight-line relation between mean measurement result and analyte concentration.
  • linear calibration curve - The expression of the relation between instrument indication and measured quantity value.

Who uses oSIST prEN ISO 11494:2026?

oSIST prEN ISO 11494:2026 is used by analytical laboratories, assay laboratories, and quality control teams working with jewellery and precious metals. It also supports manufacturers, refiners, and buyers who need a documented platinum content for platinum alloys.

In practice, users apply it for incoming inspection, process control, product release, and dispute testing. The test report format also makes it useful for certification and audit records.

What changed in oSIST prEN ISO 11494:2026 from the previous edition?

oSIST prEN ISO 11494:2026 cancels and replaces ISO 11494:2014 and is technically revised. The stated changes include:

  • the definition of bracketing was removed from Clause 3;
  • the recommended lines were removed from Clause 4;
  • reagents and the internal standard requirements were updated;
  • the preparation of the internal standard solution changed;
  • the list of calibration standards, the linearity check, and the choice of low and high standards changed;
  • aliquot-based preparation for standard and sample solutions was removed;
  • the preparation of standard and sample solutions was changed;
  • acid quantities for pressure dissolution were added;
  • bracketing and recommended lines were added in 8.4;
  • the calculation formulae were adapted;
  • the emission line no longer has to be stated in the test report;
  • the document was editorially revised.

Which standards are used with oSIST prEN ISO 11494:2026?

oSIST prEN ISO 11494:2026 refers to several other standards that support sampling, terminology and alternative platinum analysis.

  • ISO 11596 - Used for sampling of precious metals and precious metal alloys.
  • ISO 15093 - Used for the difference method when platinum content is above 990 ‰ by mass.
  • ISO 19376-1 - Supplies vocabulary terms used in the document, including precious metals, units, internal standard and test portion.
  • EN ISO 1042 - Named for grade A one-mark volumetric flasks used in the equipment list.

What does the oSIST prEN ISO 11494:2026 document contain?

oSIST prEN ISO 11494:2026 contains the full analytical workflow from sample preparation to reporting. Clause 8 includes the preparation of internal standard solution, calibration solutions, sample solutions, and the measurement sequence.

Clause 9 provides the calculation route, including corrected intensity quotients and the repeatability check, while Table 1 lists recommended wavelengths for platinum and internal standard elements and notes likely spectral interferences. Annex A explains the ICP-OES instrument arrangement and viewing modes, and Annex B summarizes interlaboratory testing data used to confirm performance.

Relations

Effective Date
18-Jun-2025

Buy Documents

Draft

oSIST prEN ISO 11494:2026

English language (15 pages)
Preview
Preview
e-Library read for
×1 day

Frequently Asked Questions

oSIST prEN ISO 11494:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Jewellery and precious metals - Determination of platinum - ICP-OES method using an internal standard element (ISO/DIS 11494:2026)". This standard covers: This document describes an analytical procedure for the determination of platinum in platinum alloys with a nominal content up to 990 ‰ (parts per thousand), including alloys according to ISO 9202.

This document describes an analytical procedure for the determination of platinum in platinum alloys with a nominal content up to 990 ‰ (parts per thousand), including alloys according to ISO 9202.

oSIST prEN ISO 11494:2026 is classified under the following ICS (International Classification for Standards) categories: 39.060 - Jewellery. The ICS classification helps identify the subject area and facilitates finding related standards.

oSIST prEN ISO 11494:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 11494:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

oSIST prEN ISO 11494:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 calibration solution
  • 3.2 bracketing
  • 3.3 laboratory sample
  • 3.4 test portion
  • 3.5 test sample solution
  • 3.6 internal standard
  • 3.7 linearity
  • 3.8 linear calibration curve
  • 4 Principle
  • 5 Reagents
  • 6 Equipment
  • 6.2 Inductively coupled argon plasma optical emission spectrometer (ICP-OES), capable of
  • 7 Sampling
  • 8 Procedure
  • 8.1 Internal standard solution
  • 8.2 Calibration solutions
  • 8.3 Sample solutions
  • 8.4 Measurement
  • 9 Calculation and expression of results
  • 9.1 Calculation
  • 9.2 Repeatability
  • 10 Test report
  • Annex A
  • Annex B
  • Bibliography

1 Scope

This document specifies an analytical method for the determination of platinum on a material considered homogeneous. The platinum content of the samples lies preferably between 50 ‰ (parts per thousand by mass) and 990 ‰ (parts per thousand by mass). Fineness above 990,0 ‰ (parts per thousand by mass) can be determined using a spectroscopy method by difference ISO 15093. NOTE Lower contents of platinum can be analysed referring to this method.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 11596, Jewellery and precious metals — Sampling of precious metals and precious metal alloys ISO 15093, Jewellery and precious metals — Determination of high purity gold, platinum and palladium — Difference method using ICP-OES ISO 19376-1, Jewellery and precious metals — Vocabulary — Part 1: Precious metals and units

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at http:// www .electropedia .org/

3.1 calibration solution

solution used to calibrate the instrument, prepared from stock solution or solution prepared with certified reference material by adding acid, buffer, reference elements and salt as needed

3.2 bracketing

analytical method consisting of bracketing the measured emission line intensity of the sample between two measurements made on calibration solutions of neighbouring concentrations within the optimum working range Note 1 to entry: Running of standards and samples in the following sequence: low standard – sample – high standard – sample – low standard – sample – high standard … [SOURCE: ISO 19376-1, 3.3.7]

3.3 laboratory sample

sample intended for laboratory inspection or testing

oSIST prEN ISO 11494:2026 ISO/DIS 11494:2026(en)

3.4 test portion

portion of material, resulting from the laboratory sample by means of an appropriate method of sample pretreatment, and having the size (volume/mass) necessary for the desired testing or analysis [SOURCE: ISO 19376-1:2025, identical]

3.5 test sample solution

solution prepared after extraction or digestion of the test sample according to appropriate specification

3.6 internal standard

compound added to a sample in a fixed amount that has similar properties to the target analyte used to correct for instrument drift and matrix interference [SOURCE: ISO 19376-1, 3.3.8]

3.7 linearity

straight-line relationship between the mean result of measurement and the quantity (concentration) of the analyte

3.8 linear calibration curve

expression of the relation between indication and corresponding measured quantity value

4 Principle

At least two accurately weighed samples are individually dissolved in aqua regia and made up to an exactly weighed mass. These sample solutions are mixed with an exact amount of internal standard and made up to the standard measuring volume.

Using ICP-OES, the platinum content of the sample solution is measured by comparison of the ratio intensities of the spectral emission of platinum and appropriate internal standard line(s) with the ratio for solutions containing known masses of platinum and internal standard using the bracketing method. Minor modifications are required when the alloy contains ruthenium, rhodium, iridium, or tungsten.

5 Reagents

During the analysis, unless otherwise stated, use only reagents of recognized analytical grade and only distilled water or water of equivalent purity. All reagents, excepting platinum, shall be platinum free. 5.1 Hydrochloric acid (HCl), approximately 30 % to 37 % HCl (mass fraction). 5.2 Nitric acid (HNO ), approximately 65 % to 70 % HNO (mass fraction). 3 3 5.3 Platinum (Pt) of 999,9 ‰ (parts per thousand by mass) minimum purity; if a lower platinum content (e.g. 999,5 ‰ (parts per thousand by mass)) is used, appropriate corrections shall be applied. 5.4 Internal standard element, e.g. Yttrium, Scandium, Indium, Germanium or Lutetium, single element standard.

The adequate specification of single element standard stock solutions shall state the acid used. Singleelement standard stock solutions can be made from high purity metals. 5.5 Copper of 999,9 ‰ (parts per thousand by mass) minimum purity.

oSIST prEN ISO 11494:2026 ISO/DIS 11494:2026(en) 5.6 Orthophosphoric acid (H PO ), 85 % (mass fraction).

3 4 5.7 Copperchloride (CuCl -H O).

2 2 5.8 Sodium nitrate (NaNO ).

6 Equipment

All equipment shall be carefully cleaned.

6.1 Customary laboratory apparatus.

6.2 Inductively coupled argon plasma optical emission spectrometer (ICP-OES), capable of

simultaneously measuring the platinum and the internal standard emission lines with a minimum optical resolution of 0,02 nm.

NOTE Annex A gives some technical background on ICP-OES.

6.3 Analytical balance, with a reading accuracy of 0,01 mg.

6.4 Sample container, preferably made of plastic. Vessels made of glass, quartz, polyethylene, polypropylene or poly-tetra-fluoroethylene (PFA or FEP) are suitable. 6.5 Argon gas, purity ≥99,995 %.

6.6 Volumetric flasks (grade A), e.g. 1 000 ml. Flasks made of glass, quartz, polyethylene, polypropylene [1] or poly-tetra-fluoroethylene (PFA, FEP) are suitable. EN ISO 1042

7 Sampling

The sampling procedure should be performed in accordance with ISO 11596.

8 Procedure

Warning — Suitable health and safety procedures should be followed.

8.1 Internal standard solution

A solution with a concentration of about 300 mg/l of In and/or Lu and/or Ge and/or 100 mg/l Sc and/or Y is prepared. Taking into account the sensitivity of the instrument, the concentration may be changed to optimize the performance. Other elements may also be used as internal standard, as long as they cannot be contained in the alloy.

8.2 Calibration solutions

The bracketing sequence requires the use of only two calibration standards, which shall cover the content of platinum sample. It is recommended to prepare a set of at least three calibration standards to check the linearity of the calibration in a preliminary test.

Weigh, for example each of about 50 mg, 75 mg and 100 mg of platinum (5.3) , reading to 0,01 mg digit in 3 beakers.

NOTE 1 The concentration of the 3 calibration standards can be adapted to the expected concentration of the alloy.

oSIST prEN ISO 11494:2026 ISO/DIS 11494:2026(en) Gently heat the sample in a glass beaker covered with a watch glass in a mixture of 100 ml HCl 5.1 and 30 ml HNO 5.2 until complete dissolution and continue to heat to expel the nitrogen oxides. Transfer the solution

in a 1 000 ml flask 6.6.

...