oSIST prEN ISO 11495:2026
(Main)Jewellery and precious metals - Determination of palladium - ICP-OES method using an internal standard element (ISO/DIS 11495:2026)
- Abstract
This document describes an analytical procedure for the determination of palladium in palladium alloys with a nominal content up to 990 ? (parts per thousand), including alloys according to ISO 9202.
- Status
- Not Published
- Public Enquiry End Date
- 14-Oct-2026
- Technical Committee
- I13 - Imaginarni 13
- Current Stage
- 4020 - Public enquire (PE) (Adopted Project)
- Start Date
- 12-Aug-2026
- Due Date
- 30-Dec-2026
- Completion Date
- 16-Oct-2026
oSIST prEN ISO 11495:2026 is a SIST standard for determining palladium in jewellery and precious metals by ICP-OES using an internal standard element. It specifies an analytical procedure for homogeneous palladium alloys with a nominal content up to 990 ‰, including alloys according to ISO 9202, and it is written for laboratories that need to measure palladium content in a controlled way.
What does oSIST prEN ISO 11495:2026 specify?
oSIST prEN ISO 11495:2026 specifies a laboratory method for palladium determination in palladium alloys. The preferred sample range is 50 ‰ to 990 ‰, and lower contents can also be analysed by reference to the method. For contents above 990.0 ‰, the document points to ISO 15093.
The document is organized into Scope, Normative references, Terms and definitions, Principle, Reagents, Apparatus, Sampling, Procedure, Calculation and expression of results, and Test report. It also includes two informative annexes that give technical background and interlaboratory testing information.
| Annex | What it covers |
|---|---|
| A | Technical background for ICP-OES, including instrument parts and viewing modes |
| B | Interlaboratory testing data and performance results |
What are the key requirements of oSIST prEN ISO 11495:2026?
Sample preparation and measurement
oSIST prEN ISO 11495:2026 requires at least two accurately weighed samples to be dissolved in aqua regia, made up to an exactly weighed mass, mixed with the internal standard, and brought to the measuring volume. In practice, this means the result is based on prepared solutions, not direct metal reading, so weighing and solution handling affect the result.
Clause 8 also requires the acid concentration of calibration solutions and sample solutions to be consistent. This matters because matrix differences can shift the ICP-OES signal and change the comparison between standards and samples.
Calibration and bracketing
The method uses ICP-OES comparison of palladium and internal standard emission intensity ratios. Clause 8.2 requires a preliminary linearity check with at least three calibration standards, and the regression coefficient for the linear calibration curve must be greater than 0.9999.
For routine measurement, the method uses bracketing with two calibration standards around the expected sample content. The sequence alternates low standard and high standard with the sample, and each solution needs stabilization, integration time, and repeated integrations. For the user, this means the instrument program and standard range must be set before testing starts.
Internal standard and special alloy cases
Clause 8.1 specifies an internal standard solution based on elements such as In, Lu, Ge, Sc or Y, with the concentration adjusted to instrument sensitivity. The internal standard is used to correct for instrument drift and matrix effects, so it helps keep the ratio measurement stable.
Clause 8.3.1 gives special preparation for alloys containing ruthenium, iridium or tungsten. In some of these cases, pressure dissolution or a preliminary alloying stage with palladium-free copper is needed, and tungsten requires orthophosphoric acid. This matters because some alloy matrices need extra preparation to dissolve properly and to avoid biased results.
Calculation, repeatability and reporting
Clause 9 calculates palladium content from corrected intensity ratios and the measured masses used in the standards and sample solution. The method requires the relative standard deviation of the measured quotients and of the final mass result to stay within the stated limit, and duplicate determinations must differ by less than 3 ‰ for palladium.
Clause 10 requires the test report to identify the sample, sampling procedure, method reference, palladium content as single and mean values, deviations from the method, unusual observations, test date, laboratory identification, and signatures. For buyers and quality managers, this is the part that shows what must be documented with the result.
What terms does oSIST prEN ISO 11495:2026 define?
- Calibration solution - A solution used to calibrate the instrument from a stock solution or certified reference material, with acids, buffer, reference elements and salt added as needed.
- Bracketing - A measurement approach where the sample signal is bracketed by two calibration standards of neighbouring concentrations.
- Laboratory sample - The sample intended for laboratory inspection or testing.
- Test portion - The portion taken from the laboratory sample after pretreatment, in the amount needed for analysis.
- Test sample solution - The solution prepared after extraction or digestion of the test sample.
- Internal standard - A compound added in a fixed amount to help correct for instrument drift and matrix interference.
- Linearity - The straight-line relationship between the mean measurement result and analyte concentration.
- Linear calibration curve - The relation between instrument indication and the corresponding measured quantity value.
Who uses oSIST prEN ISO 11495:2026?
This standard is used by analytical laboratories working in jewellery and precious metals, especially those measuring palladium alloys. It is relevant to assay laboratories, quality control teams, producers, refiners, and buyers who need a documented palladium content for acceptance, processing, or product verification.
It is also useful for technicians who prepare samples, calibrate ICP-OES instruments, and report test results in a form that can be compared between laboratories.
What changed in oSIST prEN ISO 11495:2026 from the previous edition?
oSIST prEN ISO 11495:2026 cancels and replaces ISO 11495:2014. The foreword states these main changes:
- the definition of bracketing in Clause 3 was removed
- the recommended lines in Clause 4 were removed
- reagents and internal standard requirements were updated
- preparation of the internal standard solution in 8.1 was changed
- calibration standards, their linearity check, and the choice of low and high standards in 8.2 were changed
- aliquot-based preparation in 8.2 and 8.3 was removed
- preparation of standard and sample solutions was changed
- bracketing and recommended lines were added in 8.4
- formulas in 9.1 were adapted
- the emission line was removed from the test report information
- the document was editorially revised
Which standards are used with oSIST prEN ISO 11495:2026?
- ISO 11596 - gives the sampling procedure for precious metals and precious metal alloys.
- ISO 15093 - is the method named for determining high-purity gold, platinum and palladium by difference when fineness is above 990.0 ‰.
- ISO 19376-1 - supplies vocabulary used for terms such as laboratory sample, test portion and internal standard.
- EN ISO 1042 - is cited for one-mark volumetric flasks used in the apparatus section.
What does the oSIST prEN ISO 11495:2026 document contain?
The document contains a full analytical workflow: principle, reagents, apparatus, sampling, solution preparation, measurement, calculation, repeatability and reporting. It also gives the internal standard solution, calibration solution preparation, and sample solution preparation, including special handling for ruthenium, iridium and tungsten-containing alloys.
Table 1 lists recommended palladium and internal standard wavelengths for ICP-OES. Clause 9 gives the calculation steps and formulas for corrected intensity ratios and palladium content, and Clause 10 defines what must be recorded in the test report.
Annex A explains the ICP-OES instrument setup and operation in technical terms, including plasma viewing options. Annex B summarizes interlaboratory testing data used to support the method performance.
Relations
- Effective Date
- 18-Jun-2025
Frequently Asked Questions
oSIST prEN ISO 11495:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Jewellery and precious metals - Determination of palladium - ICP-OES method using an internal standard element (ISO/DIS 11495:2026)". This standard covers: This document describes an analytical procedure for the determination of palladium in palladium alloys with a nominal content up to 990 ? (parts per thousand), including alloys according to ISO 9202.
This document describes an analytical procedure for the determination of palladium in palladium alloys with a nominal content up to 990 ? (parts per thousand), including alloys according to ISO 9202.
oSIST prEN ISO 11495:2026 is classified under the following ICS (International Classification for Standards) categories: 39.060 - Jewellery. The ICS classification helps identify the subject area and facilitates finding related standards.
oSIST prEN ISO 11495:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 11495:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
oSIST prEN ISO 11495:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 calibration solution
- 3.2 bracketing
- 3.3 laboratory sample
- 3.4 test portion
- 3.5 test sample solution
- 3.6 internal standard
- 3.7 linearity
- 3.8 linear calibration curve
- 4 Principle
- 5 Reagents
- 6 Apparatus
- 6.1 Customary laboratory apparatus
- 6.2 Inductively coupled argon plasma optical emission spectrometer (ICP-OES), capable of
- 7 Sampling
- 8 Procedure
- 8.1 Internal standard solution
- 8.2 Calibration solutions
- 8.3 Sample solutions
- 8.4 Measurement
- 9 Calculation and expression of results
- 9.1 Calculation
- 9.2 Repeatability
- 10 Test report
- Annex A
- Annex B
- Bibliography
1 Scope
This document specifies an analytical method for the determination of palladium on a material considered homogeneous. The palladium content of the samples lies preferably between 50 ‰ (parts per thousand) and 990 ‰ (parts per thousand). Fineness above 990,0 ‰ can be determined using a spectroscopy method by difference ISO 15093.
NOTE Lower contents of palladium can be analysed referring to this method.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 11596, Jewellery and precious metals — Sampling of precious metals and precious metal alloys ISO 15093, Jewellery and precious metals — Determination of high purity gold, platinum and palladium — Difference method using ICP-OES ISO 19376-1, Jewellery and precious metals — Vocabulary — Part 1: Precious metals and units
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at http:// www .electropedia .org/
3.1 calibration solution
solution used to calibrate the instrument, prepared from stock solution or solution prepared with certified reference material by adding acid, buffer, reference elements and salt as needed
3.2 bracketing
analytical method consisting of bracketing the measured emission line intensity of the sample between two measurements made on calibration solutions of neighbouring concentrations within the optimum working range Note 1 to entry: Running of standards and samples in the following sequence: low standard – sample – high standard – sample – low standard – sample – high standard … [SOURCE: ISO 19376-1, 3.3.7]
3.3 laboratory sample
sample intended for laboratory inspection or testing
oSIST prEN ISO 11495:2026 ISO/DIS 11495:2026(en)
3.4 test portion
portion of material, resulting from the laboratory sample by means of an appropriate method of sample pretreatment, and having the size (volume/mass) necessary for the desired testing or analysis [SOURCE: ISO 19376-1, 3.6.7, identical]
3.5 test sample solution
solution prepared after extraction or digestion of the test sample according to appropriate specification
3.6 internal standard
compound added to a sample in a fixed amount that has similar properties to the target analyte used to correct for instrument drift and matrix interference [SOURCE: ISO 19376-1, 3.3.8, identical]
3.7 linearity
straight-line relationship between the mean result of measurement and the quantity (concentration) of the analyte
3.8 linear calibration curve
expression of the relation between indication and corresponding measured quantity value
4 Principle
At least two accurately weighed samples are individually dissolved in aqua regia and made up to an exactly weighed mass. These sample solutions are mixed with the internal standard and made up to the standard measuring volume.
Using ICP-OES, the palladium content of the sample solution is measured by comparison of the ratio intensities of the spectral emission of palladium and appropriate internal standard line(s) with the ratios for solutions containing known masses of palladium and internal standard using the bracketing method. Minor modifications are required when the alloy contains ruthenium, rhodium, iridium, or tungsten.
5 Reagents
During the analysis, unless otherwise stated, use only reagents of recognised analytical grade and only distilled water or water of equivalent purity. All reagents, excepting palladium, shall be palladium free. 5.1 Hydrochloric acid (HCl), approximately 30 % to 37 % HCl (mass fraction). 5.2 Nitric acid (HNO ), approximately 65 % to 70 % HNO (mass fraction). 3 3 5.3 Palladium (Pd) of 999,9 ‰ minimum purity; if a lower palladium content (e.g. 999,5 ‰) is used, appropriate corrections shall be applied.
5.4 Internal standard element, e.g. Yttrium, Scandium, Indium, Germanium or Lutetium, single element standard.
The adequate specification of single element standard stock solutions shall state the acid used. Singleelement standard stock solutions can be made from high purity metals. 5.5 Copper of 999,9 ‰ minimum purity.
oSIST prEN ISO 11495:2026 ISO/DIS 11495:2026(en) 5.6 Orthophosphoric acid (H PO ), 85 % (mass fraction).
3 4 5.7 Copper chloride (CuCl -H O).
2 2 5.8 Sodium nitrate (NaNO ).
6 Apparatus
All equipment shall be carefully cleaned.
6.1 Customary laboratory apparatus
6.2 Inductively coupled argon plasma optical emission spectrometer (ICP-OES), capable of
simultaneously measuring the palladium and the internal standard emission lines with a minimum optical resolution of 0,02 nm.
NOTE Annex A gives some technical background on ICP-OES.
6.3 Analytical balance, with a reading accuracy of 0,01 mg.
6.4 Sample container, preferably made of plastic. Vessels made of glass, quartz, polyethylene, polypropylene or poly-tetra-fluoroethylene (PFA or FEP) are suitable. 6.5 Argon gas, purity ≥99,996 %.
6.6 Volumetric flasks (grade A), e.g. 1 000 ml. Flasks made of glass, quartz, polyethylene, polypropylene [1] or poly-tetra-fluoroethylene (PFA, FEP) are suitable. EN ISO 1042
7 Sampling
The sampling procedure shall be performed in accordance with ISO 11596.
8 Procedure
Warning — Suitable health and safety procedures should be followed.
8.1 Internal standard solution
A solution with a concentration of about 300 mg/l of In and/or Lu and/or Ge and/or 100 mg/l Sc and/or Y is prepared. Taking into account the sensitivity of the instrument, the concentration may be changed to optimize the performance. Other elements may also be used as internal standard, as long as they cannot be contained in the alloy.
8.2 Calibration solutions
The bracketing sequence requires the use of only two calibration standards, which shall cover the content of palladium sample. It is recommended to prepare a set of at least three calibration standards to check the linearity of the calibration in a preliminary test.
Weigh, for example each of about 50 mg, 75 mg and 100 mg of palladium 5.3, reading to 0,01 mg digit in 3 beakers.
NOTE 1 The concentration of the 3 calibration standards can be adapted to the expected concentration of the alloy.
oSIST prEN ISO 11495:2026 ISO/DIS 11495:2026(en) Gently heat the sample in a glass beaker covered with a watch glass in a mixture of 100 ml HCl 5.1 and 30 ml HNO 5.2 until complete dissolution and continue to heat to expel the nitrogen oxides. Transfer the solution
in a 1 000 ml flask 6.6.
...