SIST EN 4644-001:2018
(Main)Aerospace series - Connector, electrical and optical, rectangular, modular, rectangular inserts, operating temperature 175 °C (or 125 °C) continuous - Part 001: Technical specification
Aerospace series - Connector, electrical and optical, rectangular, modular, rectangular inserts, operating temperature 175 °C (or 125 °C) continuous - Part 001: Technical specification
This European Standard specifies the required characteristics, the condition for qualification, acceptance and quality assurance for electrical and optical rectangular connectors with single or multiple removable rectangular inserts for use in a temperature range from – 65 °C to 175 °C continuous for electrical contact.
This family of connectors is particularly suitable for aeronautic use in zones of severe environmental conditions on board aircraft, applying EN 2282.
Inserts for fiber optic contacts or mixing fiber optic contacts and electrical contacts are described in EN 4639-002.
Luft- und Raumfahrt - Elektrische und optische Rechtecksteckverbinder, modular, rechteckige Kontakteinsätze, Dauerbetriebstemperatur 175 °C (oder 125 °C) konstant - Teil 001: Technische Lieferbedingungen
Série aérospatiale - Connecteur, électrique et optique, rectangulaire, modulaire, à inserts rectangulaires, température de fonctionnement 175 °C (ou 125 °C) continu - Partie 001: Spécification technique
La présente Norme européeen définit les caractéristiques requises, les conditions de qualification, de reception et d’assurance qualité pour les connecteurs électriques et optiques rectangulaires avec des inserts rectangulaires, simples ou multiples, démontables pour un usage dans une plage de température de - 65 °C à 175 °C continu pour les contacts électriques.
Cette famille de connecteurs est particulièrement appropriée pour une utilisation aéronautique dans des zones aux conditions environnementales sévères à bord des aéronefs, suivant l’EN 2282.
Les inserts pour les contacts à fibre optique ou les contacts à fibre optique associés et les contacts électriques sont décrits dans l’EN 4639-002.
Aeronavtika - Konektor, električni in optični, pravokotni, modularni, pravokotni vložki, stalna delovna temperatura 175 °C (ali 125 °C) - 001. del: Tehnična specifikacija
Ta evropski standard določa zahtevane značilnosti, pogoje kvalifikacije, sprejemljivosti in zagotavljanja kakovosti za električne in optične pravokotne konektorje z enim ali več pravokotnimi vložki, ki jih je mogoče odstraniti, za uporabo pri stalni temperaturi od –65 °C do 175 °C za električni kontakt.
Ta družina konektorjev je ustrezna zlasti za aeronavtično uporabo na letalih v območjih z neugodnimi okoljskimi pogoji, pri čemer se uporablja standard EN 2282.
Vložki za kontakte iz optičnih vlaken ali mešanico kontaktov iz optičnih vlaken in električnih kontaktov so opisani v standardu EN 4639-002.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.VSHFLILNDFLMDLuft- und Raumfahrt - Elektrische und optische Rechtecksteckverbinder, modular, rechteckige Kontakteinsätze, Dauerbetriebstemperatur 175 °C (oder 125 °C) konstant - Teil 001: Technische LieferbedingungenSérie aérospatiale - Connecteur, électrique et optique, rectangulaire, modulaire, à inserts rectangulaires, température de fonctionnement 175 °C (ou 125 °C) continu - Partie 001: Spécification techniqueAerospace series - Connector, electrical and optical, rectangular, modular, rectangular inserts, operating temperature 175 °C (or 125 °C) continuous - Part 001: Technical specification49.060Aerospace electric equipment and systems31.220.10Plug-and-socket devices. ConnectorsICS:Ta slovenski standard je istoveten z:EN 4644-001:2017SIST EN 4644-001:2018en,fr,de01-februar-2018SIST EN 4644-001:2018SLOVENSKI
STANDARDSIST EN 4644-001:20121DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 4644-001
October
t r s y ICS
v {ä r x râ
v {ä r { r Supersedes EN
v x v væ r r sã t r s tEnglish Version
Aerospace series æ Connectorá electrical and opticalá rectangulará modulará rectangular insertsá operating Technical specification Série aérospatiale æ Connecteurá électrique et optiqueá rectangulaireá modulaireá à inserts rectangulairesá continu æ Partie
r r sã Spécification technique
Luftæ und Raumfahrt æ Elektrische und optische Rechtecksteckverbinderá modulará rechteckige Kontakteinsätzeá Dauerbetriebstemperatur
s y w
¹C Lieferbedingungen This European Standard was approved by CEN on
s t June
t r s yä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
t r s y CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
v x v væ r r sã t r s y ESIST EN 4644-001:2018
Page European foreword . 3 Introduction . 4 1 Scope . 4 2 Normative references . 4 3 Terms and definitions . 5 4 Description . 6 5 Design . 18 6 Dimensions and masses . 20 7 Tests . 80 8 Quality assurance . 93 9 Designation and marking . 98 10 Delivery conditions . 99 11 Packaging . 99 12 Storage . 99
disconnect aligning housing cavity DNC :
disconnect non aligning housing cavity N : extremity of insert retention clip reference plane P : front face of hard insert R : vertical axis of housing backshell interface RAC :
rack & panel aligning housing cavity RNC :
rack & panel non-aligning housing cavity S : horizontal axis of housing backshell interface T : backshell bottoming reference plane on housing X : horizontal axis of insert Y : vertical axis of insert
1) Published by: DoD National (US) Mil. Department of Defense http://www.defenselink.mil/ 2) Published by: SAE National (US) Society of Automotive Engineers http://www.sae.org/ SIST EN 4644-001:2018
These connectors use different types of contacts (signal, power, coaxial, triaxial, quadrax, etc) see EN 3155-002 and optical contacts see EN 4639-002. 4.2 Female housing 4.2.1 General For disconnect application, the following housings are described:
size 1 housing has quarter turn fasteners and 2 polarization keys that can take 4 positions to polarize the housing. Size 1 female housing is panel mount connector.
size 2 housing has a central coupling mechanism which can take 12 positions to polarize the housing. Size 2 female housing are either panel mount connector or cable connector.
size 2 housing has 3 polarization keys, each of them can take 4 positions to prevent mismating between male and female housing.
size 3 housing has 3 polarization keys, each of them can take 4 positions to prevent mismating between male and female housing.
size 4 housing has 3 polarization keys, each of them can take 4 positions to prevent mismating between male and female housing. Rack and panel female housing shall be installed on the aircraft side and are cable connectors. No grounding block option is available for rack and panel housings. The insert cavities are identified on the female housing by letters A, B, C, D for size 4, letters A, B, C for size 3 letters, A, B for size 2 and no letter for size 1. The insert cavities are polarized by either one (A polarizing position) or two keyways (B polarizing position) location. Housing size 1, 3 and 4 insert cavities have one keyway. Housing size 2 insert cavity identified with letter A has one keyway and insert cavity identified with letter B has two keyways. Each insert cavity has 2 insert retaining devices allowing rear insertion and rear release of the insert. Each female housing has a grounding device ensuring electrical continuity between housings before contact mating. For each female housing, some cavities are aligning cavities and other cavities are non-aligning. Aligning cavities guaranty not only the alignment between male and female housing but also guarantee the shell to shell bottoming. Non-aligning female housing cavities have a circular location tolerance. In order to define how alignment of the female and male housing is achieved, a dimension line between the 2 housing aligning cavities is defined. SIST EN 4644-001:2018
Key 1 Dimensions for housing size 1 2 Dimension for housing size n (n > 1) 3 Dimension of grounding device (optional) Figure 1 — Disconnect panel female aligning cavity (DAC) SIST EN 4644-001:2018
Key 1 Dimension of grounding device (optional) Figure 2 — Disconnect panel female non-aligning cavity (DNC) SIST EN 4644-001:2018
Key 1 Dimension for grounding device Figure 3 — Rack and panel female aligning cavity (RAC) SIST EN 4644-001:2018
Key 1 Dimension for grounding device (optional) Figure 4 — Rack and panel female non-aligning cavity (RNC) SIST EN 4644-001:2018
size 1 male housing has quarter turn fasteners and 2 polarization post that can take 4 positions to polarize the housing. Size 1 male housing is cable connector.
size 2 male housing has a central coupling mechanism which can take 12 positions to polarize the housing. Size 2 male housing is panel mount connector or cable connector. Size 1 and 2 male housings are available with (class B and F) or without grounding block (class A, C and E) allowing grounding of a cable braid with a pigtail. For rack and panel application, the following housings are described:
size 2 male housing has three polarization posts, each of them can take 4 positions to prevent mismating between male and female housing.
size 3 male housing has three polarization posts, each of them can take 4 positions to prevent mismating between male and female housing.
size 4 male housing has three polarization post, each of them can take 4 positions to prevent mismating between male and female housing. Male housing shall be installed on equipment side and can be connected to PCB or cable harness.
No grounding block option is available for rack and panel housings. The insert cavities are identified on the male housing by letters A, B, C, D for size 4, letters A, B, C for size 3, letters, A, B for size 2 and no letter for size 1. The insert cavities are polarized by either one or two keyways location. Housing size 1, 3 and 4 insert cavities have one keyway. Housing size 2 insert cavity identified with letter A has one keyway and insert cavity identified with letter B has two keyways. Each insert cavity has 2 insert retaining devices allowing rear insertion and rear release of the insert. All male housing have a minimum of 1 (for single cavity connectors) and a maximum of 2 aligning housing cavities (see Figure 5 and Figure 7); the remaining housing cavities are non-aligning cavities (see Figure 6 and Figure 8). This principle is not valid for size 4 male housing because it can be mated with 2 size 2 female housings. Aligning cavities guaranty not only the alignment between male and female housing but also guarantee the shell to shell bottoming. Non-aligning housing cavities have a circular location. In order to define how alignment of the female and male housing is achieved, a clinging dimension line between the 2 housing aligning cavities is defined. SIST EN 4644-001:2018
Key 1 Dimension for housing size 1 2 Dimension for housing size n (n > 1) Figure 5 — Disconnect panel male aligning cavity (DAC) SIST EN 4644-001:2018
Figure 6 — Disconnect panel male non-aligning cavity (DNC) SIST EN 4644-001:2018
Figure 7 — Rack and panel male aligning cavity (RAC) SIST EN 4644-001:2018
Figure 8 — Rack and panel male non-aligning cavity (RNC)
4.4 Rear accessories See EN 4644-002. 4.5 Inserts The insert assembly shall be single-bloc type design complete with contact retention systems and appropriate seals. The female inserts use female contacts and male inserts use male contacts. These inserts use contacts of size 22, 20, 16, 12, 5 and 8. The inserts are rear release rear removable from the housing. Male and female inserts can be installed either in the male or female housing. There are inserts with one polarizing rib (A polarizing position) and inserts with two polarizing ribs (B polarizing position). This means that there are inserts dedicated to housing cavities with one keyway and inserts dedicated to housing cavities with two keyways. See Table 1 below. SIST EN 4644-001:2018
A blank insert is installed in a housing cavity where no contact is required. This blank insert has no polarizing rib and the same dimensions as an insert for pin contacts. It can be installed in any male or female housing cavity. This blank insert can mate without causing any interference with an insert for male contacts or with an insert for female contacts. The blank insert does not provide sealing. 4.6 Keying mechanism Keying mechanism for disconnect connectors:
Size 1 housings have a polarizing system using polarizing posts having a L shape cross section and polarizing keys having a L shape cavity to mate with the polarizing posts. Each polarizing post and key provides 4 polarizing positions. Each post and key is retained in the housing by a special shape which allows them to be clipped in the housing. Size 1 housings have 2 polarizing pins offering 16 polarizing positions.
The size 2 housing has either a centre coupling screw or coupling nut which ensures also the polarizing function. The coupling screw has a coding peg and the coupling nut has a coding slot. The centre coupling screw and nut have an hexagonal shoulder which slides in an hexagonal print in the housing, consequently, the coupling screw or nut can take 6 positions. The coding peg on the coupling screw and the slot on the coupling nut can be vertically aligned with an angle or a flat of the hexagonal shoulder. There are 2 types of coupling screw and coupling nut, those having the coding peg or the slot aligned with a flat and those for which it is aligned with an angle of the hexagonal shoulder. These 2 types of coupling screw and nut provide a total of 12 polarizing positions. Keying mechanism for rack and panel connectors: Size 2, 3 and 4 housings have a polarizing system using polarizing posts having a L shape cross section and polarizing keys having a L shape cavity to mate with the polarizing posts. Each polarizing post and key provides 4 polarizing positions. Each post and key is retained in the housing by a special shape which allows them to be clipped in the housing.
Inserts with 2 polarizing ribs. Inserts with 1 polarizing rib shall fit the cavities of housing size 1, 3, 4 and cavity A of housing size 2. Inserts with 2 polarizing ribs shall fit the cavity B of housing size 2. The inserts shall be rear removable from the housing and shall be mechanically retained in the housing. The removal of an insert shall be done by using the tool described in product standard (see EN 4644-002). An insert is installed in the housing by hand, it is a rear snap in insert. The mating face of the insert shall ensure that sealing is provided when connectors are mated together. The interfacial seal shall be on the insert having male contacts and shall not be removable. The rear grommet shall permit sealing for all cable diameters indicated in EN 4644-002 and shall not be removable. For size 5 and 8 contacts, the insert contact cavity and the grommet shall accept the sealing boots described in EN 4530-002. The mechanical contact retention system shall be integrated in the rigid part of the insert. Connectors shall be designed to allow the insertion and removal of individual contacts without having to remove the insert from the housing. Inserts shall be designed for rear release rear removable contacts. Insertion, extraction tools are specified in EN 3155 product standards. There are 4 (four) environmental categories of inserts: Environmental inserts (with grommet and interfacial seal); Non-environmental inserts (without grommet and interfacial seal); Semi environmental inserts (with an interfacial seal and without grommet); Non-environmental inserts (without an interfacial seal and with grommet). 5.3 Connector mating sequence The mating sequence shall be the following: Shell to shell engagement and ESD discharge; Polarizing; Locking system; Grounding device system; Electrical contacts; Sealed interface compression; Metal to metal or Composite shell to shell bottoming. SIST EN 4644-001:2018
Figure 9 — Mating dimensions SIST EN 4644-001:2018
Key 1 A keying Figure 10 — Female housing SIST EN 4644-001:2018
Key 1 A keying Figure 11 — Male housing SIST EN 4644-001:2018
Figure 12 — Mating dimensions SIST EN 4644-001:2018
Key 1 A keying 2 B keying Figure 13 — Male housing SIST EN 4644-001:2018
Key 1 A keying 2 B keying Figure 14 — Female housing SIST EN 4644-001:2018
Male housing: see Figure 31 Female housing: see Figure 14 Figure 15 — Mating dimensions SIST EN 4644-001:2018
Key 1 Dimension when not under stress 2 Minimum spring compression force: 150 N per axis 3 A keying Figure 16 — Female housing SIST EN 4644-001:2018
Key 1 A keying Figure 17 — Male housing SIST EN 4644-001:2018
Figure 18 SIST EN 4644-001:2018
Key 1 A keying 2 B keying Figure 19 — Male housing with jackscrew SIST EN 4644-001:2018
Key 1 A keying 2 B keying Figure 20 — Male housing with jacknut SIST EN 4644-001:2018
Key 1 A keying 2 B keying Figure 21 — Female housing with jacknut SIST EN 4644-001:2018
Key 1 A keying 2 B keying Figure 22 — Female housing with jackscrew SIST EN 4644-001:2018
Key 1 A keying 2 Indexing point For other dimensions on the locking device, see Figure 19. Figure 23 — Male housing SIST EN 4644-001:2018
Key 1 Panel mounting faces Figure 24 — Mating dimensions SIST EN 4644-001:2018
Key 1 A keying 2 B keying Figure 25 — Male housing SIST EN 4644-001:2018
Key 1 A keying 2 B keying Figure 26 — Female housing SIST EN 4644-001:2018
Key 1 Panel mounting faces Figure 27 — Mating dimensions SIST EN 4644-001:2018
Key 1 A keying Figure 28 — Male housing SIST EN 4644-001:2018
Key 1 A keying Figure 29 — Female housing SIST EN 4644-001:2018
Key 1 Panel mounting faces Figure 30 — Mating dimensions SIST EN 4644-001:2018
Key 1 A keying Figure 31 — Male housing SIST EN 4644-001:2018
Key 1 A keying Figure 32 — Female housing SIST EN 4644-001:2018
Key 1 Vertical reference axis of connector (Br or Bp) 2 Insert longitudinal axis (Cr or Cp) 3 Blind hole optional 4 Self-locking thread 4-40 UNC 5 Radius 3,60 max. optional Figure 33 — Male and female size 1 SIST EN 4644-001:2018
Key 1 Vertical reference axis of connector (Br or Bp) 2 Horizontal reference axis of connector (Cr or Cp) 3 Optional shape Figure 34 — Male and female size 2 SIST EN 4644-001:2018
Key 1 Vertical reference axis of connector (Br) 2 Horizontal reference axis of connector (Cr) 3 Vertical axis of shell cavity 4 Optional shape 5 4-40 UNC self-locking thread. Depth = 4,50 mm min. Figure 35 — Female size 3 SIST EN 4644-001:2018
Key 1 Vertical reference axis of connector (Br) 2 Horizontal reference axis of connector (Cr) 3 Vertical axis of shell cavity 4 Optional shape 5 4-40 UNC self-locking thread. Depth = 4,50 mm min. Figure 36 — Female size 4 SIST EN 4644-001:2018
Key 1 M39029/1-101 extremity to female connector bottoming face 2 M39029/1-101 extremity to male connector bottoming face 3 Insert longitudinal axis 4 Horizontal axis of connector 5 Housing and insert vertical axis Figure 37 — Housing size 1 SIST EN 4644-001:2018
Key 1 Dimension applicable to male housing 2 Dimension applicable to female housing 3 Horizontal axis of connector 4 Vertical axis of housing cavities 5 Vertical axis of connector Figure 38 — Housing size 2 SIST EN 4644-001:2018
Key 1 Contact extremity 2 Dimension when insert is butting in rear position 3 Female contact cavity position 4 Male contact cavity position 5 Interfacial seal Figure 39 — Contact position for connector size 1 SIST EN 4644-001:2018
Key 1 Contact extremity 2 Dimension when insert is butting in rear position 3 Female contact cavity position 4 Male contact cavity position 5 Interfacial seal Figure 40 — Contact position for connector size 2, 3 and 4 SIST EN 4644-001:2018
6.5.1.3 Gap of inserts in housing cavity See Figure 41 and Figure 42.
Key 1 Area containing the insert symmetry axis (on ribs) Figure 41 — Gap along X axis SIST EN 4644-001:2018
Key 1 Area containing the insert symmetry axis (on ribs) Figure 42 — Gap along the Y axis SIST EN 4644-001:2018
Figure 43 — Female contact cavity Table 4 Contact size Ø C
Ø D min. max. min. max. 22 2,00 2,10 1,02 1,06 20 2,45 2,55 1,27 1,31 16 3,20 3,30 1,97 2,03 12 3,75 3,85 2,77 2,83 8 7,29 7,39 5,77 5,81 5 7,00 7,10 5,85 5,96 SIST EN 4644-001:2018
Key 1 Interfacial seal 2 Male contact Figure 44a — Male contact cavity SIST EN 4644-001:2018
6.5.1.4.3 Size 8 and 5 rear male cavity
Size 8 cavity rear diameter Size 5 cavity rear diameter Figure 44b — Size 8 and 5 rear male cavity SIST EN 4644-001:2018
available Not
available Not
available Not
available Not
available Not
available B 45 85 55 90 Not
available Not
available Not
available Not
available Not
available Not
available C Not
available Not
available Not
available Not
available 35 45 60 65 75 90 D Not
available Not
available Not
available Not
available 35 45 60 65 75 90 E 30 40 40 50 Not
available Not
available Not
available Not
available Not
available Not
available F 35 Not
available 45 Not
available Not
available Not
available Not
available Not
available Not
available Not
available
6.7 Contact arrangements Contact arrangements in the insert are specified by Figures 45 to 65 which show the mating face of the inserts for pin contacts. The true positioning for contact cavities is defined in Tables 7. Identification of the contact position shall be permanently marked in contrasting colour on the mating face of the insert (optional on interfacial seal) and on the rear face of the wire sealing grommet, identification shall not be recessed or raised on the sealing surfaces. Table 7 Contact size Contact position 22
Ø 0,23 P X Y
Ø 0,23 P X Y
Ø 0,23 P X Y
Ø 0,23 P X Y
Ø 0,27 P X Y
Ø 0,27 P X Y
Key 1 1 or 2 polarization ribs 2 Centre line Figure 45 — Contact arrangement 40 Table 8 Dimensions in millimetres Contact position Y X − 11,43
8,89
6,35 3,81
1,27 1,27 3,81 6,35 8,89 11,43
3,81 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1
1,27 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1
1,27 C10 C9 C8 C7 C6 C5 C4 C3 C2 C1
3,81 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 Mating face of insert for male contacts is shown.
Table 9 Contacts Size Quantity Location 22 40 A1 to D10
Key 1 1 or 2 polarization ribs 2 Centre line Figure 46 — Contact arrangement 48 Table 10 Dimensions in millimetres Contact position Y X -11,43 -10,16 -8,89 -7,62 -6,35 -5,08 -3,81 -2,54 -1,27 0 +1,27 +2,54 +3,81 +5,08 +6,35 +7,62 +8,89 +10,16 +11,43 +4,2 A10 – A9 – A8 – A7 – A6 – A5 – A4 – A3 – A2 – A1 +2,1 – B9 – B8 – B7 – B6 – B5 – B4 – B3 – B2 – B1 – 0 C10 – C9 – C8 – C7 – C6 – C5 – C4 – C3 – C2 – C1 -2,1 – D9 – D8 – D7 – D6 – D5 – D4 – D3 – D2 – D1 – -4,2 E10 – E9 – E8 – E7 – E6 – E5 – E4 – E3 – E2 – E1 Mating face of insert for male contacts is shown.
Table 11 Contacts Size Quantity Location 22 48 A1 to E10
Key 1 1 or 2 polarization ribs 2 Centre line Figure 47 — Contact arrangement 34 Table 12 Dimensions in millimetres Contact position Y X
-11,60 -10,15 -8,70 -7,25 -5,80 -4,35 -2,90 -1,45 0 +1,45 +2,90 +4,35 +5,80 +7,25 +8,70 +10,15 +11,60 +3,68 – 8 – 7 – 6 – 5 – 4 – 3 – 2 – 1 – +1,225 17 – 16 – 15 – 14 – 13 – 12 – 11 – 10 – 9 -1,225 – 25 – 24 – 23 – 22 – 21 – 20 – 19 – 18 – -3,68 34 – 33 – 32 – 31 – 30 – 29 – 28 – 27 – 26 Mating face of insert for male contacts is shown.
Table 13 Contacts Size Quantity Location 22 18 9 to 17, 26 to 34 20 16 1 to 8, 18 to 25
Key 1 1 or 2 polarization ribs 2 Centre line Figure 48 — Contact arrangement 30 Table 14 Dimensions in millimetres Contact position Y X − 11,20
9,60
8,00
6,40
4,80
3,20
1,60 0
1,60
3,20
4,80
6,40
8,00
9,60
11,20
3,68 – 7 – 6 – 5 – 4 – 3 – 2 – 1 –
1,225 15 – 14 – 13 – 12 – 11 – 10 – 9 – 8
1,225 – 22 – 21 – 20 – 19 – 18 – 17 – 16 –
3,68 30 – 29 – 28 – 27 – 26 – 25 – 24 – 23 Mating face of insert for male contacts is shown.
Table 15 Contacts Size Quantity Location 20 30 1 to 30
Key 1 1 or 2 polarization ribs 2 Centre line Figure 49 — Contact arrangement 25Q1 Table 16 Dimensions in millimetres Contact position Y X − 11,43
8,89
6,35
3,81
1,27
1,27
8,00
3,81 6 5 4 3 2 1 –
1,27 12 11 10 9 8 7 – 0 – – – – – – 25
1,27 18 17 16 15 14 13 –
3,81 24 23 22 21 20 19 – Mating face of insert for male contacts is shown.
Table 17 Contacts Size Quantity Location 22 24 1 to 24 8 quadrax (not power) 1 25 SIST EN 4644-001:2018
Key 1 1 or 2 polarization ribs 2 Centre line Figure 50 — Contact arrangement 25P1 Table 18 Dimensions in millimetres Contact position Y X − 11,43
8,89
6,35
3,81
1,27
1,27
8,00
3,81 7 6 5 4 3 2 –
1,27 13 12 11 10 9 8
0 – – – – – – 1
1,27 19 18 17 16 15 14
3,81 25 24 23 22 21 20
Mating face of insert for male contacts is shown.
Table 19 Contacts Size Quantity Location 22 24 2 to 25 8 power 1 1
Key 1 1 or 2 polarization ribs 2 Centre line Figure 51 — Contact arrangement 28 Table 20 Dimensions in millimetres Contact position Y X − 11,43
10,20
7,45
6,35
3,81
1,27
1,27
3,81
6,35
7,45
10,20
11,43
3,81 – – – 6 5 4 3 2 1 – – –
3,30 – D – – – – – – – – A –
1,27 – – – – 10 9 8 7 – – – – 0 22 – E – – – – – – B – 21
1,27 – – – – 14 13 12 11 – – – –
3,30 – F – – – – – – – – C –
3,81 – – – 20 19 18 17 16 15 – – – Mating face of insert for male contacts is shown. Table 21 Contacts Size Quantity Location 22 22 1 to 22 16 6 A to F
Key 1 1 or 2 polarization ribs 2 Centre line Figure 52 — Contact arrangement 22 Table 22 Dimensions in millimetres Contact position Y X − 11,20
10,60
8,00
6,36
4,80
2,12
1,60
1,60
2,12
4,80
6,36
8,00
10,60
11,20
3,68 8 – 7 – 6 – 5 4 – 3 – 2 – 1 0 – 14 – 13 – 12 – – 11 – 10 – 9 –
3,68 22 – 21 – 20 – 19 18 – 17 – 16 – 15 Mating face of insert for male contacts is shown.
Table 23 Contacts Size Quantity Location 20 16 1 to 8, 15 to 22 16 6 9 to 14
Key 1 1 or 2 polarization ribs 2 Centre line Figure 53 — Contact arrangement 22V Table 24 Dimensions in millimetres Contact position Y X − 11,20
10,60
8,00
6,36
4,80
2,12
1,60
1,60
2,12
4,80
6,36
8,00
10,60
11,20
3,30 – 6 – 5 – 4 – – 3 – 2 – 1 –
0,48 14 – 13 – 12 – 11 10 – 9 – 8 – 7
3,68 22 – 21 – 20 – 19 18 – 17 – 16 – 15 Mating face of insert for male contacts is shown.
Table 25 Contacts Size Quantity Location 20 16 7 to 22 16 6 1 to 6 SIST EN 4644-001:2018
Key 1 1 or 2 polarization ribs 2 Centre line Figure 54 — Contact arrangement 20C1 Table 26 Dimensions in millimetres Contact position Y X − 11,20
9,60
8,00 6,40
4,80
3,20
1,60 0
1,60
3,2
8,00
3,675 – 5 – 4 – 3 – 2 – 1 –
1,225 10 – 9 – 8 – 7 – 6 – – 0 – – – – – – – – – – 20
1,225 – 14 – 13 – 12 – 11 – – –
3,675 19 – 18 – 17 – 16 – 15 – – Mating face of insert for male contacts is shown.
Table 27 Contacts Size Quantity Location 20 19 1 to 19 5 all except power 1 20 SIST EN 4644-001:2018
Key 1 1 or 2 polarization ribs 2 Centre line Figure 55 — Contact arrangement 20P1 Table 28 Dimensions in millimetres Contact position Y X − 11,20
9,60
8,00
6,40
4,80
3,20
1,60 0
1,60
3,2
8,00
3,675 – 6 – 5 – 4 – 3 – 2 –
1,225 11 – 10 – 9 – 8 – 7 – – 0 – – – – – – – – – – 1
1,225 – 15 – 14 – 13 – 12 – – –
3,675 20 – 19 – 18 – 17 – 16 – – Mating face of insert for male contacts is shown.
Table 29 Contacts Size Quantity Location 20 19 2 to 20 5 power 1 1 SIST EN 4644-001:2018
Key 1 1 or 2 polarization ribs 2 Centre line Figure 56 — Contact arrangement 17 Table 30 Dimensions in millimetres Contact position Y X − 11,20
9,85
8,00
6,40
4,80
3,20
1,60 0
1,60
3,20
4,80
6,40
8,00
9,85
11,20
3,67 – –
2,30 – 8
1,225 – –
1,225 – –
2,50 – –
3,68 17 – 16
12 Mating face of insert for male contacts is shown.
Table 31 Contacts Size Quantity Location 20 14 1 to 4, 6,7,9,11 to 14, 15 to 17 12 3 5, 8, 10 SIST EN 4644-001:2018
Key 1 1 or 2 polarization ribs 2 Centre line Figure 57 — Contact arrangement 14 Table 32 Dimensions in millimetres Contact position Y X − 10,68
8,01
5,34
2,67 0
2,67
5,34
8,01
10,68
3,30 5
1 0
3,30 14
10 Mating face of insert for male contacts is shown.
Table 33 Contacts Size Quantity Location 16 14 1 to 14 SIST EN 4644-001:2018
Key 1 1 or 2 polarization ribs 2 Centre line Figure 58 — Contact arrangement 13C1 Table 34 Dimensions in millimetres Contact position Y X − 11,43
10,68
7,13
6,18
2,93 0
2,93
6,18
7,13
10,68
11,43
3,62 4
– 3 – 2 – – – 1
2,00
6 – – – – – 5 – –
0,60 8
– – – – – – – – 7
1,25
– – – A1 – – – – –
3,30
11 – – – 10 – 9 – Mating face of insert for male contacts is shown.
Table 35 Contacts Size Quantity Location 20 6 1, 2, 3, 4, 7, 8 16 4 9, 10, 11, 12 12 2 5, 6 5 (all except power) 1 A1 SIST EN 4644-001:2018
Key 1 1 or 2 polarization ribs 2 Centre line Figure 59 — Contact arrangement 13P1 Table 36 Dimensions in millimetres Contact position Y X − 11,43
10,68
7,13
6,18
2,93 0
2,93
6,18
7,13
10,68
11,43
3,62 4 – – – 3 – 2 – – – 1
2,00 – – 6 – – – – – 5 – –
0,60 8 – – – – – – – – – 7
1,25 – – – – – 13 – – – – –
3,30 – 12 – 11 – – – 10 – 9 – Mating face of insert for male contacts is shown.
Table 37 Contacts Size Quantity Location 20 6 1, 2, 3, 4, 7, 8 16 4 9, 10, 11, 12 12 2 5, 6 5 power 1 13 SIST EN 4644-001:2018
Key 1 1 or 2 polarization ribs 2 Centre line Figure 60 — Contact arrangement 10Q2 Table 38 Dimensions in millimetres Contact position Y X − 8,20
2,70
1,70 0
1,70
2,70
8,20
3,70 – 5 – – – 3 –
2,50 – – – 4 – – – 0 2 – 7 – 6 – 1
2,50 – – – 9 – – –
3,70 – 10 – – – 8 – Mating face of insert for male contacts is shown.
Table 39 Contacts Size Quantity Location 20 8 3 to 10 8 quadrax 2 1 and 2
5,70
1,90
1,90
5,70
9,50
2,50 3 – 2 – 1 –
2,50 – 6 – 5 – 4 Mating face of insert for male contacts is shown.
Table 41 Contacts Size Quantity Location 12 6 1 to 6 SIST EN 4644-001:2018
Key 1 1 or 2 polarization ribs 2 Centre line Figure 62 — Contact arrangement 3Q3 Table 42 Dimensions in millimetres Contacts position Y X − 8,36 0
8,36
1,25 3 – 1
1,25 – 2 – Mating face of insert for male contacts is shown.
Table 43 Contacts Size Quantity Location 8 quadrax 3 1 to 3 SIST EN 4644-001:2018
Key 1 1 or 2 polarization ribs 2 Centre line Figure 63 — Contact arrangement C3 Table 44 Dimensions in millimetres Contact position Y X − 8,50 0
8,50 0 C B A Mating face of insert for male contacts is shown.
Table 45 Contacts Size Quantity Location 5 all except power 3 A to C SIST EN 4644-001:2018
Key 1 1 or 2 polarization ribs 2 C
...