Indoor air - Part 6: Determination of organic compounds (VVOC, VOC, SVOC) in indoor and test chamber air by active sampling on sorbent tubes, thermal desorption and gas chromatography using MS or MS FID

This document specifies a method for determination of volatile organic compounds (VOC) in indoor air and in air sampled for the determination of the emission from products or materials used in indoor environments (according to ISO 16000‑1) using test chambers and test cells. The method uses sorbent sampling tubes with subsequent thermal desorption (TD) and gas chromatographic (GC) analysis employing a capillary column and a mass spectrometric (MS) detector with or without an additional flame ionisation detector (FID)[13].
The method is applicable to the measurement of most GC-compatible vapour-phase organic compounds at concentrations ranging from micrograms per cubic metre to several milligrams per cubic metre. Many very volatile organic compounds (VVOC) and semi-volatile organic compounds (SVOC) can be analysed depending on the sorbents used.

Air intérieur - Partie 6: Dosage des composés organiques (COTV, COV, COSV) dans l'air intérieur et l'air de chambre d'essai par prélèvement actif sur tubes à sorbant, désorption thermique et chromatographie en phase gazeuse avec détection MS ou MS-FID

Le présent document spécifie une méthode permettant de doser les composés organiques volatils (COV) dans l’air intérieur et dans l’air prélevé afin de déterminer l’émission de produits ou de matériaux utilisés dans les environnements intérieurs (conformément à l’ISO 16000-1) à l’aide de chambres d’essai et de cellules d’essai. La méthode utilise un prélèvement sur tubes à sorbant puis une désorption thermique (TD) et une analyse par chromatographie en phase gazeuse (GC) utilisant une colonne capillaire et un détecteur à spectrométrie de masse (MS) avec ou sans détecteur à ionisation de flamme (FID) supplémentaire[13].
La méthode est applicable au mesurage de la plupart des composés organiques volatils en phase vapeur avec une analyse GC, à des concentrations allant de quelques microgrammes par mètre cube à plusieurs milligrammes par mètre cube. De nombreux composés organiques très volatils (COTV) et composés organiques semi-volatils (COSV) peuvent être analysés en fonction des sorbants utilisés.

Notranji zrak - 6. del: Določevanje hlapnih organskih spojin (VVOC, VOC, SVOC) v notranjem zraku in zraku v preskusnih komorah z aktivnim vzorčenjem v cevkah z adsorpcijskim polnilom, termično desorpcijo in plinsko kromatografijo z MS ali MS-FID

Ta dokument določa metodo za določevanje hlapnih organskih spojin (VOC) v notranjem zraku in zraku, vzorčenem za določevanje emisij iz izdelkov ali materialov, ki se uporabljajo v notranjih okoljih (v skladu s standardom ISO 16000-1), s preskusnimi komorami in celicami. Metoda uporablja cevke z adsorpcijskim polnilom za vzorčenje s poznejšo termično desorpcijo (TD) in analizo s plinsko kromatografijo (GC), pri kateri se uporabljata kapilarna kolona in masno selektivni (MS) detektor z dodatnim plamensko ionizacijskim detektorjem (FID) ali brez njega [13].
Metoda se uporablja za merjenje večine organskih spojin v hlapni fazi, združljivih s plinsko kromatografijo, v koncentracijah od nekaj mikrogramov na kubični meter do več miligramov na kubični meter. Številne zelo hlapne organske spojine (VVOC) in polhlapne organske spojine (SVOC) je mogoče analizirati odvisno od uporabljenih sorbentov.

General Information

Status
Published
Public Enquiry End Date
01-Mar-2021
Publication Date
11-Jun-2023
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
26-May-2023
Due Date
31-Jul-2023
Completion Date
12-Jun-2023

Relations

Buy Standard

Standard
ISO 16000-6:2023
English language
41 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ISO 16000-6:2021 - Indoor air — Part 6: Determination of organic compounds (VVOC, VOC, SVOC) in indoor and test chamber air by active sampling on sorbent tubes, thermal desorption and gas chromatography using MS or MS FID Released:8/20/2021
English language
36 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 16000-6:2021 - Indoor air
English language
36 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 16000-6:2021 - Air intérieur — Partie 6: Dosage des composés organiques (COTV, COV, COSV) dans l'air intérieur et l'air de chambre d'essai par prélèvement actif sur tubes à sorbant, désorption thermique et chromatographie en phase gazeuse avec détection MS ou MS-FID Released:8/20/2021
French language
39 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 16000-6:2021 - Air intérieur
French language
39 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2023
Nadomešča:
SIST ISO 16000-6:2012
Notranji zrak - 6. del: Določevanje hlapnih organskih spojin (VVOC, VOC, SVOC) v
notranjem zraku in zraku v preskusnih komorah z aktivnim vzorčenjem v cevkah z
adsorpcijskim polnilom, termično desorpcijo in plinsko kromatografijo z MS ali
MS-FID
Indoor air - Part 6: Determination of organic compounds (VVOC, VOC, SVOC) in indoor
and test chamber air by active sampling on sorbent tubes, thermal desorption and gas
chromatography using MS or MS FID
Air intérieur - Partie 6: Dosage des composés organiques (COTV, COV, COSV) dans
l'air intérieur et l'air de chambre d'essai par prélèvement actif sur tubes à sorbant,
désorption thermique et chromatographie en phase gazeuse avec détection MS ou MS-
FID
Ta slovenski standard je istoveten z: ISO 16000-6:2021
ICS:
13.040.20 Kakovost okoljskega zraka Ambient atmospheres
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

INTERNATIONAL ISO
STANDARD 16000-6
Third edition
2021-08
Indoor air —
Part 6:
Determination of organic compounds
(VVOC, VOC, SVOC) in indoor and test
chamber air by active sampling on
sorbent tubes, thermal desorption and
gas chromatography using MS or MS
FID
Air intérieur —
Partie 6: Dosage des composés organiques (COTV, COV, COSV) dans
l'air intérieur et l'air de chambre d'essai par prélèvement actif sur
tubes à sorbant, désorption thermique et chromatographie en phase
gazeuse avec détection MS ou MS-FID
Reference number
©
ISO 2021
© ISO 2021
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2021 – All rights reserved

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Abbreviated terms . 3
5 Principle . 3
6 Reagents and materials . 3
7 Apparatus . 5
8 Conditioning and storage of sorbent tubes . 9
8.1 Conditioning . 9
8.2 Storage of conditioned sorbent tubes before sampling .10
9 Sampling .10
9.1 Air sampling .10
9.2 Sampling volumes .10
9.3 Storage of loaded samples.11
9.4 Field blanks .11
10 Analysis .11
10.1 Determination of VOC, VVOC and SVOC .11
10.1.1 Analytical System .11
10.1.2 Identification of target compounds .13
10.1.3 Quantification of target compounds and compounds according to task list .14
10.1.4 Determining the lower limit of quantification .15
10.2 Identified non-target compounds and unidentified compounds .16
11 Concentration of analytes in the sampled air .16
12 Performance characteristics .17
13 Test report .18
14 Quality control .19
Annex A (informative) Total volatile organic compounds (TVOC) and total semi-volatile
organic compounds (TSVOC) .20
Annex B (informative) Examples of compounds detected in indoor air and from building
products in test chambers .22
Annex C (informative) Description of sorbents .27
Annex D (informative) Guide on sorbent usage .28
Annex E (informative) Safe sampling volumes for selected organic vapours .30
Annex F (informative) Storage recovery of solvents on sorbent tubes .33
Bibliography .35
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www .iso .org/
iso/ foreword .html.
This document was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee SC 6,
Indoor air.
This third edition cancels and replaces the second edition (ISO 16000-6:2011), which has been
technically revised. The main changes compared to the previous edition are as follows: ®
— other sorbents than Tenax TA are allowed to be used;
— descriptions of VVOC and SVOC measurements are included in the mandatory part of the document.
A list of all parts in the ISO 16000 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/ members .html.
iv © ISO 2021 – All rights reserved

Introduction
ISO 16000-1 establishes general requirements relating to the measurement of indoor air pollutants
and the important conditions to be observed before or during the sampling of individual pollutants or
groups of pollutants. Aspects of the determination (sampling and analysis) and the sampling strategy
of specific pollutants or groups of pollutants are specified in the subsequent parts of ISO 16000 (see
Foreword).
ISO 16000-5 (dealing with VOC sampling strategy) is a link between ISO 16000-1 (a generic standard
establishing the principles) and this part of ISO 16000, which deals with sampling and analytical
measurements.
[3]-[7]
ISO 16017 (see Clause 2 and Reference [8]) and ISO 12219 also focus on measuring vapour-phase
organic chemicals in air.
This document can be applied to measure vapour phase organic compounds in indoor environments
that include buildings with varying designs and purposes and cabins for different modes of transport,
as well as measurement in product emission test chambers. These measurements can be for a
range of purposes as described in ISO 16000-1 and ISO 16000-5, therefore the requirement for the
measurement may be well defined by the task descriptor or may be quite open. For example, the task
may be to determine a specific list of target chemicals with a defined sampling time and sensitivity
of measurement or it may be to investigate the cause of a reported and poorly understood indoor air
quality problem. Depending upon the task of measurement the user of this document should select the
most appropriate sampling and analytical instrumentation and conditions. This document provides
that information in the normative part combined with informative guidance. Figure 1 refers to the most
critical parts of the standard with regard to selection of the most appropriate methodology for the task
®1)
to be undertaken. Tenax TA only or multisorbents can be used to capture ranges of vapour phase
organic compounds. Multisorbents are used for wider ranges and may improve recovery of compounds.
Figure 1 — Measurement scheme showing different ways of analysing air samples depending on
the respective task including target compounds ®
1) Tenax TA is a trade name of a product supplied by Buchem. This information is given for the convenience of
users of this document and does not constitute an endorsement by ISO of the product named. Equivalent products
may be used, if they can be shown to lead to the same results.
------
...


INTERNATIONAL ISO
STANDARD 16000-6
Third edition
2021-08
Indoor air —
Part 6:
Determination of organic compounds
(VVOC, VOC, SVOC) in indoor and test
chamber air by active sampling on
sorbent tubes, thermal desorption and
gas chromatography using MS or MS
FID
Air intérieur —
Partie 6: Dosage des composés organiques (COTV, COV, COSV) dans
l'air intérieur et l'air de chambre d'essai par prélèvement actif sur
tubes à sorbant, désorption thermique et chromatographie en phase
gazeuse avec détection MS ou MS-FID
Reference number
©
ISO 2021
© ISO 2021
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2021 – All rights reserved

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Abbreviated terms . 3
5 Principle . 3
6 Reagents and materials . 3
7 Apparatus . 5
8 Conditioning and storage of sorbent tubes . 9
8.1 Conditioning . 9
8.2 Storage of conditioned sorbent tubes before sampling .10
9 Sampling .10
9.1 Air sampling .10
9.2 Sampling volumes .10
9.3 Storage of loaded samples.11
9.4 Field blanks .11
10 Analysis .11
10.1 Determination of VOC, VVOC and SVOC .11
10.1.1 Analytical System .11
10.1.2 Identification of target compounds .13
10.1.3 Quantification of target compounds and compounds according to task list .14
10.1.4 Determining the lower limit of quantification .15
10.2 Identified non-target compounds and unidentified compounds .16
11 Concentration of analytes in the sampled air .16
12 Performance characteristics .17
13 Test report .18
14 Quality control .19
Annex A (informative) Total volatile organic compounds (TVOC) and total semi-volatile
organic compounds (TSVOC) .20
Annex B (informative) Examples of compounds detected in indoor air and from building
products in test chambers .22
Annex C (informative) Description of sorbents .27
Annex D (informative) Guide on sorbent usage .28
Annex E (informative) Safe sampling volumes for selected organic vapours .30
Annex F (informative) Storage recovery of solvents on sorbent tubes .33
Bibliography .35
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www .iso .org/
iso/ foreword .html.
This document was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee SC 6,
Indoor air.
This third edition cancels and replaces the second edition (ISO 16000-6:2011), which has been
technically revised. The main changes compared to the previous edition are as follows: ®
— other sorbents than Tenax TA are allowed to be used;
— descriptions of VVOC and SVOC measurements are included in the mandatory part of the document.
A list of all parts in the ISO 16000 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/ members .html.
iv © ISO 2021 – All rights reserved

Introduction
ISO 16000-1 establishes general requirements relating to the measurement of indoor air pollutants
and the important conditions to be observed before or during the sampling of individual pollutants or
groups of pollutants. Aspects of the determination (sampling and analysis) and the sampling strategy
of specific pollutants or groups of pollutants are specified in the subsequent parts of ISO 16000 (see
Foreword).
ISO 16000-5 (dealing with VOC sampling strategy) is a link between ISO 16000-1 (a generic standard
establishing the principles) and this part of ISO 16000, which deals with sampling and analytical
measurements.
[3]-[7]
ISO 16017 (see Clause 2 and Reference [8]) and ISO 12219 also focus on measuring vapour-phase
organic chemicals in air.
This document can be applied to measure vapour phase organic compounds in indoor environments
that include buildings with varying designs and purposes and cabins for different modes of transport,
as well as measurement in product emission test chambers. These measurements can be for a
range of purposes as described in ISO 16000-1 and ISO 16000-5, therefore the requirement for the
measurement may be well defined by the task descriptor or may be quite open. For example, the task
may be to determine a specific list of target chemicals with a defined sampling time and sensitivity
of measurement or it may be to investigate the cause of a reported and poorly understood indoor air
quality problem. Depending upon the task of measurement the user of this document should select the
most appropriate sampling and analytical instrumentation and conditions. This document provides
that information in the normative part combined with informative guidance. Figure 1 refers to the most
critical parts of the standard with regard to selection of the most appropriate methodology for the task
®1)
to be undertaken. Tenax TA only or multisorbents can be used to capture ranges of vapour phase
organic compounds. Multisorbents are used for wider ranges and may improve recovery of compounds.
Figure 1 — Measurement scheme showing different ways of analysing air samples depending on
the respective task including target compounds ®
1) Tenax TA is a trade name of a product supplied by Buchem. This information is given for the convenience of
users of this document and does not constitute an endorsement by ISO of the product named. Equivalent products
may be used, if they can be shown to lead to the same results.
INTERNATIONAL STANDARD ISO 16000-6:2021(E)
Indoor air —
Part 6:
Determination of organic compounds (VVOC, VOC, SVOC) in
indoor and test chamber air by active sampling on sorbent
tubes, thermal desorption and gas chromatography using
MS or MS FID
1 Scope
This document specifies a method for determination of volatile organic compounds (VOC) in indoor
air and in air sampled for the determination of the emission from products or materials used in indoor
environments (according to ISO 16000-1) using test chambers and test cells. The method uses sorbent
sampling tubes with subsequent thermal desorption (TD) and gas chromatographic (GC) analysis
employing a capillary column and a mass spectrometric (MS) detector with or without an additional
[13]
flame ionisation detector (FID) .
The method is applicable to the measurement of most GC-compatible vapour-phase organic compounds
at concentrations ranging from micrograms per cubic metre to several milligrams per cubic metre.
Many very volatile organic compounds (VVOC) and semi-volatile organic compounds (SVOC) can be
analysed depending on the sorbents used.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
...


INTERNATIONAL ISO
STANDARD 16000-6
Third edition
2021-08
Indoor air —
Part 6:
Determination of organic compounds
(VVOC, VOC, SVOC) in indoor and test
chamber air by active sampling on
sorbent tubes, thermal desorption and
gas chromatography using MS or MS
FID
Air intérieur —
Partie 6: Dosage des composés organiques (COTV, COV, COSV) dans
l'air intérieur et l'air de chambre d'essai par prélèvement actif sur
tubes à sorbant, désorption thermique et chromatographie en phase
gazeuse avec détection MS ou MS-FID
Reference number
©
ISO 2021
© ISO 2021
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2021 – All rights reserved

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Abbreviated terms . 3
5 Principle . 3
6 Reagents and materials . 3
7 Apparatus . 5
8 Conditioning and storage of sorbent tubes . 9
8.1 Conditioning . 9
8.2 Storage of conditioned sorbent tubes before sampling .10
9 Sampling .10
9.1 Air sampling .10
9.2 Sampling volumes .10
9.3 Storage of loaded samples.11
9.4 Field blanks .11
10 Analysis .11
10.1 Determination of VOC, VVOC and SVOC .11
10.1.1 Analytical System .11
10.1.2 Identification of target compounds .13
10.1.3 Quantification of target compounds and compounds according to task list .14
10.1.4 Determining the lower limit of quantification .15
10.2 Identified non-target compounds and unidentified compounds .16
11 Concentration of analytes in the sampled air .16
12 Performance characteristics .17
13 Test report .18
14 Quality control .19
Annex A (informative) Total volatile organic compounds (TVOC) and total semi-volatile
organic compounds (TSVOC) .20
Annex B (informative) Examples of compounds detected in indoor air and from building
products in test chambers .22
Annex C (informative) Description of sorbents .27
Annex D (informative) Guide on sorbent usage .28
Annex E (informative) Safe sampling volumes for selected organic vapours .30
Annex F (informative) Storage recovery of solvents on sorbent tubes .33
Bibliography .35
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www .iso .org/
iso/ foreword .html.
This document was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee SC 6,
Indoor air.
This third edition cancels and replaces the second edition (ISO 16000-6:2011), which has been
technically revised. The main changes compared to the previous edition are as follows: ®
— other sorbents than Tenax TA are allowed to be used;
— descriptions of VVOC and SVOC measurements are included in the mandatory part of the document.
A list of all parts in the ISO 16000 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/ members .html.
iv © ISO 2021 – All rights reserved

Introduction
ISO 16000-1 establishes general requirements relating to the measurement of indoor air pollutants
and the important conditions to be observed before or during the sampling of individual pollutants or
groups of pollutants. Aspects of the determination (sampling and analysis) and the sampling strategy
of specific pollutants or groups of pollutants are specified in the subsequent parts of ISO 16000 (see
Foreword).
ISO 16000-5 (dealing with VOC sampling strategy) is a link between ISO 16000-1 (a generic standard
establishing the principles) and this part of ISO 16000, which deals with sampling and analytical
measurements.
[3]-[7]
ISO 16017 (see Clause 2 and Reference [8]) and ISO 12219 also focus on measuring vapour-phase
organic chemicals in air.
This document can be applied to measure vapour phase organic compounds in indoor environments
that include buildings with varying designs and purposes and cabins for different modes of transport,
as well as measurement in product emission test chambers. These measurements can be for a
range of purposes as described in ISO 16000-1 and ISO 16000-5, therefore the requirement for the
measurement may be well defined by the task descriptor or may be quite open. For example, the task
may be to determine a specific list of target chemicals with a defined sampling time and sensitivity
of measurement or it may be to investigate the cause of a reported and poorly understood indoor air
quality problem. Depending upon the task of measurement the user of this document should select the
most appropriate sampling and analytical instrumentation and conditions. This document provides
that information in the normative part combined with informative guidance. Figure 1 refers to the most
critical parts of the standard with regard to selection of the most appropriate methodology for the task
®1)
to be undertaken. Tenax TA only or multisorbents can be used to capture ranges of vapour phase
organic compounds. Multisorbents are used for wider ranges and may improve recovery of compounds.
Figure 1 — Measurement scheme showing different ways of analysing air samples depending on
the respective task including target compounds ®
1) Tenax TA is a trade name of a product supplied by Buchem. This information is given for the convenience of
users of this document and does not constitute an endorsement by ISO of the product named. Equivalent products
may be used, if they can be shown to lead to the same results.
INTERNATIONAL STANDARD ISO 16000-6:2021(E)
Indoor air —
Part 6:
Determination of organic compounds (VVOC, VOC, SVOC) in
indoor and test chamber air by active sampling on sorbent
tubes, thermal desorption and gas chromatography using
MS or MS FID
1 Scope
This document specifies a method for determination of volatile organic compounds (VOC) in indoor
air and in air sampled for the determination of the emission from products or materials used in indoor
environments (according to ISO 16000-1) using test chambers and test cells. The method uses sorbent
sampling tubes with subsequent thermal desorption (TD) and gas chromatographic (GC) analysis
employing a capillary column and a mass spectrometric (MS) detector with or without an additional
[13]
flame ionisation detector (FID) .
The method is applicable to the measurement of most GC-compatible vapour-phase organic compounds
at concentrations ranging from micrograms per cubic metre to several milligrams per cubic metre.
Many very volatile organic compounds (VVOC) and semi-volatile organic compounds (SVOC) can be
analysed depending on the sorbents used.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
...


NORME ISO
INTERNATIONALE 16000-6
Troisième édition
2021-08
Air intérieur —
Partie 6:
Dosage des composés organiques
(COTV, COV, COSV) dans l'air
intérieur et l'air de chambre d'essai
par prélèvement actif sur tubes à
sorbant, désorption thermique et
chromatographie en phase gazeuse
avec détection MS ou MS-FID
Indoor air —
Part 6: Determination of organic compounds (VVOC, VOC, SVOC) in
indoor and test chamber air by active sampling on sorbent tubes,
thermal desorption and gas chromatography using MS or MS FID
Numéro de référence
©
ISO 2021
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2021
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2021 – Tous droits réservés

Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Termes abrégés . 3
5 Principe . 3
6 Réactifs et matériaux . 3
7 Appareillage . 6
8 Conditionnement et conservation des tubes à sorbant .11
8.1 Conditionnement .11
8.2 Conservation des tubes à sorbant conditionnés avant prélèvement .11
9 Prélèvement .11
9.1 Prélèvement d’air .11
9.2 Volumes de prélèvement .12
9.3 Conservation des échantillons chargés .12
9.4 Blancs de site .12
10 Analyse .13
10.1 Dosage des COV, des COTV et des COSV.13
10.1.1 Système analytique .13
10.1.2 Identification des composés cibles .15
10.1.3 Quantification des composés cibles et des composés en fonction de la liste
de tâches .15
10.1.4 Détermination de la limite inférieure de quantification . .18
10.2 Composés non cibles identifiés et composés non identifiés .18
11 Concentration en analytes de l’air prélevé .18
12 Caractéristiques de performance .20
13 Rapport d’essai .21
14 Contrôle qualité .21
Annexe A (informative) Composés organiques volatils totaux (COVT) et composés
organiques semi-volatils totaux (COSVT) .23
Annexe B (informative) Exemples de composés détectés dans l’air intérieur et émanant des
produits de construction dans les chambres d’essai .25
Annexe C (informative) Description des sorbants .30
Annexe D (informative) Guide d’utilisation des sorbants .31
Annexe E (informative) Volumes limites de prélèvement des vapeurs organiques sélectionnées .33
Annexe F (informative) Taux de récupération des composés fixés sur des tubes à sorbant
après conservation .36
Bibliographie .38
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes
nationaux de normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est
en général confiée aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l'ISO participent également aux travaux.
L'ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier, de prendre note des différents
critères d'approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www
.iso .org/ directives).
L'attention est attirée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l'élaboration du document sont indiqués dans l'Introduction et/ou dans la liste des déclarations de
brevets reçues par l'ISO (voir www .iso .org/ brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l'ISO liés à l'évaluation de la conformité, ou pour toute information au sujet de l'adhésion
de l'ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir www .iso .org/ avant -propos.
Le présent document a été élaboré par le comité technique ISO/TC 146, Qualité de l’air, sous-comité SC 6,
Air intérieur.
Cette troisième édition annule et remplace la deuxième édition (ISO 16000-6:2011), qui a fait l’objet
d’une révision technique. Les principales modifications par rapport à l’édition précédente sont les
suivantes: ®
— l’utilisation d’autres sorbants que le Tenax TA est autorisée;
— les descriptions des mesurages des COTV et COSV sont incluses dans la partie obligatoire du présent
document.
Une liste de toutes les parties de la série ISO 16000 se trouve sur le site web de l’ISO.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www .iso .org/ fr/ members .html.
iv © ISO 2021 – Tous droits réservés

Introduction
L’ISO 16000-1 établit les exigences générales relatives au mesurage des polluants de l’air intérieur et les
conditions qu’il est important de respecter avant ou pendant l’échantillonnage de polluants isolés ou de
groupes de polluants. Les détails relatifs au dosage (échantillonnage et analyse) ainsi que la stratégie
d’échantillonnage des polluants ou des groupes spécifiques de polluants sont spécifiés dans les autres
parties de l’ISO 16000 (voir l’Avant-propos).
L’ISO 16000-5 (traitant de la stratégie d’échantillonnage des COV) est un lien entre l’ISO 16000-1 (une
norme générique établissant les principes) et la présente partie de l’ISO 16000 traitant du prélèvement
et des mesurages analytiques.
[3]-[7]
L’ISO 16017 (voir Article 2 et Référence [8]) et l’ISO 12219 portent également sur les mesurages
des substances chimiques organiques en phase vapeur dans l’air.
Le présent document peut être appliqué pour mesurer les composés organiques en phase vapeur dans
les environnements intérieurs qui comprennent les bâtiments ayant diverses conceptions et fonctions
et les habitacles de différents modes de transport, tout comme pour effectuer des mesurages dans
les chambres d’essai d’émission de produit. Ces mesurages peuvent convenir pour divers objectifs
tels que décrits dans l’ISO 16000-1 et l’ISO 16000-5. Par conséquent, l’exigence relative au mesurage
peut être bien définie par le descripteur de tâche ou peut être relativement ouverte. Par exemple, la
tâche peut consister à déterminer une liste spécifique de substances chimiques cibles avec une durée
de prélèvement et une sensibilité de mesurage définies, ou elle peut consister à étudier la cause d’un
problème de qualité de l’air intérieur qui a été rapporté et mal compris. Selon la tâche du mesurage,
l’utilisateur du présent document doit choisir l’instrumentation et les conditions de prélèvement et
d’analyse les plus appropriées. Le présent document fournit ces informations dans la partie normative,
en association avec des recommandations informatives. La Figure 1 se rapporte aux principales parties
de la norme concernant le choix de la méthode la mieux adaptée à la tâche à entreprendre. Le Tenax
®1)
TA seul ou plusieurs sorbants peuvent être utilisés pour capter divers composés organiques en
phase vapeur. Plusieurs sorbants sont utilisés pour des gammes plus larges et peuvent améliorer la
récupération des composés.
Figure 1 — Schéma de mesurage illustrant différentes façons d’analyser des échantillons d’air
en fonction de la tâche correspondante, y compris des composés cibles
1) Tenax TA est une appellation commerciale d'un produit fourni par Buchem. Cette information est donnée par
souci de commodité à l'intention des utilisateurs du présent document et ne saurait constituer un engagement de
l'ISO à l’égard de ce produit. Des produits équivalents peuvent être utilisés s’il est démontré qu’ils conduisent aux
mêmes résultats.
NORME INTERNATIONALE ISO 16000-6:2021(F)
Air intérieur —
Partie 6:
Dosage des composés organiques (COTV, COV, COSV) dans
l'air intérie
...


NORME ISO
INTERNATIONALE 16000-6
Troisième édition
2021-08
Air intérieur —
Partie 6:
Dosage des composés organiques
(COTV, COV, COSV) dans l'air
intérieur et l'air de chambre d'essai
par prélèvement actif sur tubes à
sorbant, désorption thermique et
chromatographie en phase gazeuse
avec détection MS ou MS-FID
Indoor air —
Part 6: Determination of organic compounds (VVOC, VOC, SVOC) in
indoor and test chamber air by active sampling on sorbent tubes,
thermal desorption and gas chromatography using MS or MS FID
Numéro de référence
©
ISO 2021
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2021
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2021 – Tous droits réservés

Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Termes abrégés . 3
5 Principe . 3
6 Réactifs et matériaux . 3
7 Appareillage . 6
8 Conditionnement et conservation des tubes à sorbant .11
8.1 Conditionnement .11
8.2 Conservation des tubes à sorbant conditionnés avant prélèvement .11
9 Prélèvement .11
9.1 Prélèvement d’air .11
9.2 Volumes de prélèvement .12
9.3 Conservation des échantillons chargés .12
9.4 Blancs de site .12
10 Analyse .13
10.1 Dosage des COV, des COTV et des COSV.13
10.1.1 Système analytique .13
10.1.2 Identification des composés cibles .15
10.1.3 Quantification des composés cibles et des composés en fonction de la liste
de tâches .15
10.1.4 Détermination de la limite inférieure de quantification . .18
10.2 Composés non cibles identifiés et composés non identifiés .18
11 Concentration en analytes de l’air prélevé .18
12 Caractéristiques de performance .20
13 Rapport d’essai .21
14 Contrôle qualité .21
Annexe A (informative) Composés organiques volatils totaux (COVT) et composés
organiques semi-volatils totaux (COSVT) .23
Annexe B (informative) Exemples de composés détectés dans l’air intérieur et émanant des
produits de construction dans les chambres d’essai .25
Annexe C (informative) Description des sorbants .30
Annexe D (informative) Guide d’utilisation des sorbants .31
Annexe E (informative) Volumes limites de prélèvement des vapeurs organiques sélectionnées .33
Annexe F (informative) Taux de récupération des composés fixés sur des tubes à sorbant
après conservation .36
Bibliographie .38
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes
nationaux de normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est
en général confiée aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l'ISO participent également aux travaux.
L'ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier, de prendre note des différents
critères d'approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www
.iso .org/ directives).
L'attention est attirée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l'élaboration du document sont indiqués dans l'Introduction et/ou dans la liste des déclarations de
brevets reçues par l'ISO (voir www .iso .org/ brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l'ISO liés à l'évaluation de la conformité, ou pour toute information au sujet de l'adhésion
de l'ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir www .iso .org/ avant -propos.
Le présent document a été élaboré par le comité technique ISO/TC 146, Qualité de l’air, sous-comité SC 6,
Air intérieur.
Cette troisième édition annule et remplace la deuxième édition (ISO 16000-6:2011), qui a fait l’objet
d’une révision technique. Les principales modifications par rapport à l’édition précédente sont les
suivantes: ®
— l’utilisation d’autres sorbants que le Tenax TA est autorisée;
— les descriptions des mesurages des COTV et COSV sont incluses dans la partie obligatoire du présent
document.
Une liste de toutes les parties de la série ISO 16000 se trouve sur le site web de l’ISO.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www .iso .org/ fr/ members .html.
iv © ISO 2021 – Tous droits réservés

Introduction
L’ISO 16000-1 établit les exigences générales relatives au mesurage des polluants de l’air intérieur et les
conditions qu’il est important de respecter avant ou pendant l’échantillonnage de polluants isolés ou de
groupes de polluants. Les détails relatifs au dosage (échantillonnage et analyse) ainsi que la stratégie
d’échantillonnage des polluants ou des groupes spécifiques de polluants sont spécifiés dans les autres
parties de l’ISO 16000 (voir l’Avant-propos).
L’ISO 16000-5 (traitant de la stratégie d’échantillonnage des COV) est un lien entre l’ISO 16000-1 (une
norme générique établissant les principes) et la présente partie de l’ISO 16000 traitant du prélèvement
et des mesurages analytiques.
[3]-[7]
L’ISO 16017 (voir Article 2 et Référence [8]) et l’ISO 12219 portent également sur les mesurages
des substances chimiques organiques en phase vapeur dans l’air.
Le présent document peut être appliqué pour mesurer les composés organiques en phase vapeur dans
les environnements intérieurs qui comprennent les bâtiments ayant diverses conceptions et fonctions
et les habitacles de différents modes de transport, tout comme pour effectuer des mesurages dans
les chambres d’essai d’émission de produit. Ces mesurages peuvent convenir pour divers objectifs
tels que décrits dans l’ISO 16000-1 et l’ISO 16000-5. Par conséquent, l’exigence relative au mesurage
peut être bien définie par le descripteur de tâche ou peut être relativement ouverte. Par exemple, la
tâche peut consister à déterminer une liste spécifique de substances chimiques cibles avec une durée
de prélèvement et une sensibilité de mesurage définies, ou elle peut consister à étudier la cause d’un
problème de qualité de l’air intérieur qui a été rapporté et mal compris. Selon la tâche du mesurage,
l’utilisateur du présent document doit choisir l’instrumentation et les conditions de prélèvement et
d’analyse les plus appropriées. Le présent document fournit ces informations dans la partie normative,
en association avec des recommandations informatives. La Figure 1 se rapporte aux principales parties
de la norme concernant le choix de la méthode la mieux adaptée à la tâche à entreprendre. Le Tenax
®1)
TA seul ou plusieurs sorbants peuvent être utilisés pour capter divers composés organiques en
phase vapeur. Plusieurs sorbants sont utilisés pour des gammes plus larges et peuvent améliorer la
récupération des composés.
Figure 1 — Schéma de mesurage illustrant différentes façons d’analyser des échantillons d’air
en fonction de la tâche correspondante, y compris des composés cibles
1) Tenax TA est une appellation commerciale d'un produit fourni par Buchem. Cette information est donnée par
souci de commodité à l'intention des utilisateurs du présent document et ne saurait constituer un engagement de
l'ISO à l’égard de ce produit. Des produits équivalents peuvent être utilisés s’il est démontré qu’ils conduisent aux
mêmes résultats.
NORME INTERNATIONALE ISO 16000-6:2021(F)
Air intérieur —
Partie 6:
Dosage des composés organiques (COTV, COV, COSV) dans
l'air intérie
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.