SIST EN 61009-2-1:1996
(Main)Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) -- Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) -- Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage
This clause of Part 1 is applicable, except as follows: Replace the first paragraph by the following: This standard applies to residual current operated circuit-breakers with integral overcurrent protection (RCBO's) functionally independent of line voltage, for household and similar uses incorporating overcurrent protection having rated voltages not exceeding 440 V a.c. rated currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A, for operation at 50 Hz or 60 Hz.
Fehlerstrom-Schutzschalter mit Überstromauslöser (RCBO's) für Hausinstallationen und für ähnliche Anwendungen -- Teil 2-1: Anwendbarkeit der Festlegungen für die Funktion des RCBO's unabhänging von der Netzspannung
Interrupteurs automatiques à courant différentiel résiduel avec protection contre les surintensités incorporée pour installations domestiques et analogues (DD) -- Partie 2-1: Applicabilité des règles générales aux DD fonctionnellement indépendants de la tension d'alimentation
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCOB's) - Part 2-1: Applicability of the general rules to RCOB's functionally independent of line voltage (IEC 1009-2-1:1991)
Ta točka 1. dela se uporablja, razen kot sledi: Prvi odstavek je treba nadomestiti z: Ta standard se uporablja za odklopnike na preostali (residualni) tok z vgrajeno nadtokovno zaščito za gospodinjsko in podobno rabo (RCBO's), ki so funkcionalno neodvisni od linijske napetosti in uporabljajo nadtokovno zaščito, pri čemer nazivna izmenična napetost ne presega 440 V, nazivni tok ne presega 125 A, nazivne kratkostične zmogljivosti pa ne presegajo 25.000 A med delovanjem pri 50 Hz ali 60 Hz.
General Information
- Status
- Published
- Publication Date
- 29-Feb-1996
- Technical Committee
- EPR - Electrical accessories
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Mar-1996
- Due Date
- 01-Mar-1996
- Completion Date
- 01-Mar-1996
Relations
- Effective Date
- 21-Sep-2010
Overview
SIST EN 61009-2-1:1996 is a European standard issued by the CLC that specifies requirements for Residual Current Operated Circuit-Breakers with integral Overcurrent protection, commonly known as RCBOs. This particular part 2-1 of the standard addresses RCBOs that are functionally independent of line voltage, designed for household and similar electrical installations. It sets out the applicability of general rules ensuring safety and performance compliance for devices operating at rated voltages up to 440 V AC, rated currents not exceeding 125 A, and rated short-circuit capacities up to 25,000 A at standard frequencies of 50 Hz or 60 Hz.
Key Topics
Functionally Independent RCBOs: The standard covers RCBOs that operate independently of the line voltage, ensuring reliable residual current and overcurrent protection regardless of voltage fluctuations.
Rated Characteristics: Defines devices with rated voltages ≤ 440 V AC, rated currents ≤ 125 A, and short-circuit breaking capacities ≤ 25,000 A.
Household and Similar Uses: Focuses on residential electrical installations and comparable environments where such protective devices are critical for safety.
Overcurrent Protection Integration: Specifies the combination of residual current detection and overcurrent protection within a single device.
Compliance with General Rules: Adapts the general rules from Part 1 of the EN 61009 series to specifically suit the unique functional independence from line voltage in these RCBOs.
Applications
This standard guides manufacturers, electrical designers, and installers in the selection and deployment of RCBOs that provide enhanced safety against electrical faults including earth leakage and overcurrent in household and similar settings.
Typical applications include:
- Protecting circuits in residential homes against electric shock and fire hazards.
- Usage in commercial buildings with similar residential electrical load characteristics.
- Integration in consumer units or distribution boards requiring compact, reliable residual current and overcurrent protection.
- Ensuring compliance with electrical safety regulations combining the features of residual current detection and overcurrent interruption.
Related Standards
- EN 61009-1: General requirements and tests for RCBOs including standard operating conditions and construction.
- IEC 61009 series: International standards covering residual current operated circuit breakers with overcurrent protection.
- EN 60947 series: Standards relating to low-voltage switchgear and controlgear, relevant for broader circuit protection strategies.
- National Electrical Codes: Local regulatory frameworks that often reference EN standards for RCBO compliance.
Keywords: EN 61009-2-1, RCBO, residual current operated circuit-breakers, overcurrent protection, household electrical safety, line voltage independent RCBOs, rated voltage 440V, rated current 125A, electrical standard, circuit protection devices.
Frequently Asked Questions
SIST EN 61009-2-1:1996 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) -- Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage". This standard covers: This clause of Part 1 is applicable, except as follows: Replace the first paragraph by the following: This standard applies to residual current operated circuit-breakers with integral overcurrent protection (RCBO's) functionally independent of line voltage, for household and similar uses incorporating overcurrent protection having rated voltages not exceeding 440 V a.c. rated currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A, for operation at 50 Hz or 60 Hz.
This clause of Part 1 is applicable, except as follows: Replace the first paragraph by the following: This standard applies to residual current operated circuit-breakers with integral overcurrent protection (RCBO's) functionally independent of line voltage, for household and similar uses incorporating overcurrent protection having rated voltages not exceeding 440 V a.c. rated currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A, for operation at 50 Hz or 60 Hz.
SIST EN 61009-2-1:1996 is classified under the following ICS (International Classification for Standards) categories: 29.120.50 - Fuses and other overcurrent protection devices. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 61009-2-1:1996 has the following relationships with other standards: It is inter standard links to SIST EN 61009-2-1:1996/A11:2000. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 61009-2-1:1996 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase SIST EN 61009-2-1:1996 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-1996
Residual current operated circuit-breakers with integral overcurrent protection for
household and similar uses (RCOB's) - Part 2-1: Applicability of the general rules
to RCOB's functionally independent of line voltage (IEC 1009-2-1:1991)
Residual current operated circuit-breakers with integral overcurrent protection for
household and similar uses (RCBO's) -- Part 2-1: Applicability of the general rules to
RCBO's functionally independent of line voltage
Fehlerstrom-Schutzschalter mit Überstromauslöser (RCBO's) für Hausinstallationen und
für ähnliche Anwendungen -- Teil 2-1: Anwendbarkeit der Festlegungen für die Funktion
des RCBO's unabhänging von der Netzspannung
Interrupteurs automatiques à courant différentiel résiduel avec protection contre les
surintensités incorporée pour installations domestiques et analogues (DD) -- Partie 2-1:
Applicabilité des règles générales aux DD fonctionnellement
...