SIST EN 300 019-1-4 V2.1.1:2006
(Main)Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-4: Classification of environmental conditions; Stationary use at non-weatherprotected locations
- Abstract
The purpose of the present document is to define a class of environmental conditions and their severities to which equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. The present document applies to equipment mounted for stationary use including periods of erection work, down time, maintenance and repair at non-weatherprotected locations defined in clause 5.
- Status
- Published
- Publication Date
- 31-Jan-2006
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Feb-2006
- Due Date
- 01-Feb-2006
- Completion Date
- 01-Feb-2006
SIST EN 300 019-1-4 V2.1.1:2006 is the Slovenian adoption of ETSI EN 300 019-1-4 V2.1.1, a European Telecommunications Standard from ETSI. It classifies severe environmental conditions for telecommunications equipment used at stationary, non-weatherprotected locations. In practice, it helps users choose the right environmental class for exposed telecom installations and the related test approach.
What does SIST EN 300 019-1-4 V2.1.1:2006 specify?
SIST EN 300 019-1-4 V2.1.1:2006 defines environmental classes and the severities to which equipment may be exposed at non-weatherprotected locations. The standard focuses on conditions that are harmful to equipment and that are only rarely exceeded, generally with a probability below 1%.
The scope applies to equipment mounted for stationary use, including erection work, downtime, maintenance, and repair. That matters because the document covers not only normal operation, but also the periods when equipment is installed or serviced outdoors.
The document is organized into:
- Clause 3 - definitions
- Clause 4 - environmental classes
- Clause 5 - environmental conditions
- Annex A - bibliography
Clause 4 sets out four classes: 4.1, 4.1E, 4.2L, and 4.2H. Clause 5 then details the environmental parameters behind those classes.
What are the key requirements of SIST EN 300 019-1-4 V2.1.1:2006?
SIST EN 300 019-1-4 V2.1.1:2006 gives a practical classification scheme for exposed stationary telecom equipment. The main task for the reader is to match the installation site to the right class and then use the listed severities for design, testing, or acceptance.
Climatic classes and their use
Clause 4 divides the classes into general climatic conditions and extreme climatic conditions. Classes 4.1 and 4.1E cover most of Europe, while 4.2L and 4.2H are for extremely cold or extremely warm dry locations worldwide. This helps a designer or buyer decide whether a normal European outdoor site or a more severe climate must be considered.
Climatic conditions
Clause 5.1 lists the climatic parameters used to define the classes, including air temperature, humidity, rain intensity, temperature change rate, air pressure, solar radiation, air movement, condensation, precipitation, water from sources other than rain, and icing or frosting. The climatograms in Figures 1 and 2 show how the classes sit within temperature and humidity limits. In practice, this is the core reference for comparing a site climate with the intended equipment environment.
Biological and chemical exposure
Clause 5.2 covers biological conditions, including mould, fungus, rodents, and other animals harmful to products, with a special 4B2 class for some cases. Clause 5.3 covers chemically active substances such as salt mist, sulphur dioxide, hydrogen sulphide, chlorine, hydrochloric acid, hydrofluoric acid, ammonia, ozone, and nitrogen oxides. This matters where equipment is installed in coastal, urban, industrial, or contamination-prone areas.
Sand, dust, vibration, and shock
Clause 5.4 covers mechanically active substances such as sand and dust, including a special 4S3 class for 4.2H. Clause 5.5 specifies stationary vibration and non-stationary vibration, including shock type II. The note in 5.5 points readers to random vibration severities in ETSI EN 300 019-2-4 when that better reflects real use.
Earthquake conditions
Clause 5.6 applies when earthquakes are likely. It uses Response Spectrum (RS) and Zero Period Acceleration (ZPA) concepts and is written for equipment mounted at ground level or on rigid structures. For installations on pylons, poles, or other non-rigid supports, the structure must be considered in the test or a corrected RS must be determined.
What terms does SIST EN 300 019-1-4 V2.1.1:2006 define?
- Absolute humidity - the mass of water vapour in grammes associated with one cubic metre of dry air.
- Non-weatherprotected location - a location where the equipment is not protected from direct weather influences.
- Relative humidity - the ratio between water vapour pressure in moist air and saturation vapour pressure at the same temperature.
- Stationary use - equipment firmly mounted or permanently placed at a site, with only short handling during installation, downtime, maintenance, and repair.
- Response Spectrum (RS) - a graph showing the maximum response of single-degree-of-freedom oscillators as a function of frequency during transient base motion.
- Zero Period Acceleration (ZPA) - the high-frequency asymptotic acceleration of the response spectrum, representing the largest peak base acceleration.
Who uses SIST EN 300 019-1-4 V2.1.1:2006?
SIST EN 300 019-1-4 V2.1.1:2006 is used by telecom equipment designers, environmental test engineers, quality managers, and buyers who specify outdoor or exposed installations. It helps them classify the site environment, decide which class applies, and translate that into design assumptions or test conditions.
It is relevant for telecommunications equipment installed at stationary locations that are exposed to climate, contamination, vibration, dust, or earthquake risk. It is also useful when a site includes periods of erection work, maintenance, or repair.
What changed in SIST EN 300 019-1-4 V2.1.1:2006 from the previous edition?
The history records earlier ETS 300 019-1-4 edition 1 from February 1992 and Amendment 1 from June 1997, followed by ETSI EN 300 019-1-4 V2.1.1. It also records the publication as V2.1.1 in March 2003.
Which standards are used with SIST EN 300 019-1-4 V2.1.1:2006?
The document cites these references and companion parts:
- IEC 60721-3-4 - provides the environmental parameter classes that this document combines for stationary use at non-weatherprotected locations.
- IEC 60721-2-4 - gives background on solar radiation and temperature, used in the climatic discussion.
- IEC 60068-2-27 - provides shock test guidance, referenced for shock-related vibration definitions.
- IEC 60721-2-6 - provides earthquake vibration and shock environment data, used for seismic conditions.
- IEC 60068-3-3 - gives seismic test methods and guidance for the earthquake section.
- ETSI EN 300 019-1-3 - covers stationary use at weatherprotected locations, the companion classification part for sheltered sites.
- ETSI EN 300 019-2-4 - gives the environmental tests linked to these non-weatherprotected location classes.
What does the SIST EN 300 019-1-4 V2.1.1:2006 document contain?
The document contains classification tables for climatic, biological, chemically active, and mechanically active conditions, plus mechanical and earthquake parameters. It also includes climatograms in Figures 1 and 2 and an earthquake response spectrum in Figure 3.
Tables 1 to 6 give the severities for the different environmental parameters, while Table 7 lists the acceleration coordinates for the response spectrum. Annex A provides a bibliography.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.
IMP NDT d.o.o.
Non-destructive testing services. Radiography, ultrasonic, magnetic particle, penetrant, visual inspection.
Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Sponsored listings
Frequently Asked Questions
SIST EN 300 019-1-4 V2.1.1:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-4: Classification of environmental conditions; Stationary use at non-weatherprotected locations". This standard covers: The purpose of the present document is to define a class of environmental conditions and their severities to which equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. The present document applies to equipment mounted for stationary use including periods of erection work, down time, maintenance and repair at non-weatherprotected locations defined in clause 5.
The purpose of the present document is to define a class of environmental conditions and their severities to which equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. The present document applies to equipment mounted for stationary use including periods of erection work, down time, maintenance and repair at non-weatherprotected locations defined in clause 5.
SIST EN 300 019-1-4 V2.1.1:2006 is classified under the following ICS (International Classification for Standards) categories: 19.040 - Environmental testing; 33.050.01 - Telecommunication terminal equipment in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 019-1-4 V2.1.1:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2006
2NROMVNLLQåHQLULQJ((±2NROMVNLSRJRMLLQSUHVNXVLYSOLYRYRNROMDQD
WHOHNRPXQLNDFLMVNRRSUHPR±GHO.ODVLILNDFLMDRNROMVNLKSRJRMHY±)LNVQD
XSRUDEDQDORNDFLMDKNLQLVR]DãþLWHQHSUHGYUHPHQVNLPLYSOLYL
Environmental Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 1-4: Classification of environmental conditions;
Stationary use at non-weatherprotected locations
Ta slovenski standard je istoveten z: EN 300 019-1-4 Version 2.1.1
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
European Standard (Telecommunications series)
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 1-4: Classification of environmental conditions;
Stationary use at non-weatherprotected locations
2 ETSI EN 300 019-1-4 V2.1.1 (2003-03)
Reference
REN/EE-01027-1-4
Keywords
environment, testing, equipment pratice
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, send your comment to:
editor@etsi.org
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2003.
All rights reserved.
TM TM TM
DECT , PLUGTESTS and UMTS are Trade Marks of ETSI registered for the benefit of its Members.
TM
TIPHON and the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
ETSI
3 ETSI EN 300 019-1-4 V2.1.1 (2003-03)
Contents
Intellectual Property Rights.4
Foreword.4
1 Scope.5
2 References.5
3 Definitions.6
4 Environmental classes.6
4.1 Class 4.1: Non-weatherprotected locations .7
4.2 Class 4.1E: Non-weatherprotected locations - extended .7
4.3 Class 4.2L: Non-weatherprotected locations - extremely cold.7
4.4 Class 4.2H: Non-weatherprotected locations - extremely warm dry.8
5 Environmental conditions.9
5.1 Climatic conditions.9
5.2 Biological conditions.9
5.3 Chemically active substances .10
5.4 Mechanically active substances.10
5.5 Mechanical conditions.11
5.6 Earthquake conditions.11
Annex A (informative): Bibliography.14
History .15
ETSI
4 ETSI EN 300 019-1-4 V2.1.1 (2003-03)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
All published ETSI deliverables shall include information which directs the reader to the above source of information.
Foreword
This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental
Engineering (EE).
The present document is part 1, sub part 4 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions"; (see note 1)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations";
Part 2: "Specification of environmental tests". (see note 2)
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use. Sub-part 1-0 forms a general overview of part 1.
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
National transposition dates
Date of adoption of this EN: 21 March 2003
Date of latest announcement of this EN (doa): 30 June 2003
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 December 2003
Date of withdrawal of any conflicting National Standard (dow): 31 December 2003
ETSI
5 ETSI EN 300 019-1-4 V2.1.1 (2003-03)
1 Scope
The purpose of the present document is to define a class of environmental conditions and their severities to which
equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The
severities specified are those which will have a low probability of being exceeded; generally less than 1 %.
The present document applies to equipment mounted for stationary use including periods of erection work, down time,
maintenance and repair at non-weatherprotected locations defined in clause 5.
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present
document.
• References are either specific (identified by date of publication and/or edition number or version number) or
non-specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
[1] IEC 60721-3-4: "Classification of environmental conditions - Part 3: Classification of groups of
environmental parameters and their severities - Section 4: Stationary use at non-weatherprotected
locations".
[2] IEC 60721-2-4: "Classification of environmental conditions - Part 2-4: Environmental conditions
appearing in nature - Solar radiation and temperature".
[3] IEC 60068-2-27: "Environmental testing. Part 2: Tests. Test Ea and guidance: Shock".
[4] IEC 60721-2-6: "Classification of environmental conditions. Part 2: Environmental conditions
appearing in nature - Earthquake vibration and shock".
[5] IEC 60068-3-3: "Environmental testing - Part 3: Guidance. Seismic test methods for equipment".
[6] ETSI EN 300 019-1-3: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-3: Classification of environmental
conditions; Stationary use at weatherprotected locations".
[7] ETSI EN 300 019-2-4: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2-4: Specification of environmental
tests; Stationary use at non-weatherprotected locations".
ETSI
6 ETSI EN 300 019-1-4 V2.1.1 (2003-03)
3 Definitions
For the purposes of the present document, the following terms and definitions apply:
absolute humidity: mass of water vapour in grammes which is associated with one cubic metre of dry air in an
air/water vapour mixture
non-weatherprotected location: location at which the equipment is not protected from direct weather influences
relative humidity: ratio of the partial pressure of the water vapour in moist air at a given temperature, to the partial
pressure of the water vapour in saturated air at the same temperature
stationary use: The equipment is mounted firmly on the structure, or on mounting devices, or it is permanently placed
at a certain site. It is not intended for portable use - but short periods of handling during erection works, down time,
maintenance and repair at the location are included.
4 Environmental classes
The classes shown in parentheses, e.g. (4C3), may be selected for special applications.
These classes apply to a non-weatherprotected location.
These classes apply to locations:
- which are directly exposed to an open-air climate, including solar radiation, movement of the surrounding air,
precipitation and water jets; splashing water;
- where mould growth, or attacks by animals but excluding termites, may occur;
- with normal levels of contaminants experienced in urban areas with industrial activities scattered over the
whole area and/or with heavy traffic. It also applies to coastal areas;
NOTE 1: At locations in the immediate neighbourhood of industrial sources with chemical emissions either special
precautions must be taken or a special chemical class must be chosen.
- in areas with sand or dust sources, including urban areas;
NOTE 2: At locations in geographical areas with wind-driven sand or dust in air special precautions must be taken
or a special class for mechanically active substances must be chosen.
- where transmitted vibrations are experienced from machines or passing vehicles. Higher level shocks may be
experienced e.g. from adjacent machines.
NOTE 3: More severe mechanical conditions are to be expected for equipment intended for public use. Special
requirements should be stated for such equipment, e.g. protection against vandalism.
If earthquake conditions can be expected, the conditions stated in clause 5.6 apply.
Two groups of classes are considered:
- Classes 4.1 and 4.1E apply to general climatic conditions - applies to climatic conditions in most of Europe.
- Classes 4.2L and 4.2H apply to extreme climatic conditions. These classes should be considered
...