SIST EN ISO 9905:2000
(Main)Technical specifications for centrifugal pumps - Class I (ISO 9905:1994)
- Abstract
Consists of a basic text covering general requirements. The technical requirements refer only to the pump unit. Includes design features concerned with installation, maintenance and safety of such pumps, including baseplate, coupling and auxiliary piping. The selection of the class to be used is made in accordance with the technical requirements for the application for which the pump is intended. The class chosen is to be agreed between purchaser and manufacturer/supplier.
- Status
- Published
- Publication Date
- 30-Nov-2000
- Technical Committee
- SS SPL - Technical Board for the general field
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Dec-2000
- Due Date
- 01-Dec-2000
- Completion Date
- 01-Dec-2000
SIST EN ISO 9905:2000 is the Slovenian standard adopting ISO 9905:1994 for Class I centrifugal pumps. It specifies the most severe technical requirements for the pump unit, including design, materials, inspection, tests, dispatch preparation and the information that the purchaser and manufacturer/supplier must agree on. It is meant for selecting, ordering, designing and accepting centrifugal pumps in industrial services where Class I requirements are needed.
What does SIST EN ISO 9905:2000 specify?
SIST EN ISO 9905:2000 covers Class I centrifugal pumps and focuses on the pump unit itself. It includes design features for installation, maintenance and safety, such as the baseplate, coupling and auxiliary piping. Storage pumps are outside its scope.
The standard is organized into clauses on scope, normative references, definitions, design, materials, shop inspection and tests, preparation for dispatch, and responsibilities. It also uses bold text to flag points where the purchaser must decide or where agreement with the manufacturer/supplier is needed.
Annexes A-D are normative, and Annexes E-L are informative.
| Annex | What it covers |
|---|---|
| A | Centrifugal pump data sheet |
| B | External forces and moments on branches |
| C | Enquiry, proposal, purchase order |
| D | Documentation after purchase order |
| E | Peak displacement |
| F | Examples of seal arrangements |
| G | Piping arrangements for seals |
| H | Code for identification of fluid connections |
| J | Materials and material specifications for centrifugal pump parts |
| K | Check-list |
| L | Bibliography |
What are the key requirements of SIST EN ISO 9905:2000?
SIST EN ISO 9905:2000 is built around ordered technical information, defined duty conditions and controlled mechanical design. In practice, the buyer and supplier need to agree early on the service, the fluid, the installation conditions and the level of detail to be documented.
Order information and technical precedence
Clause 4 states that when documents conflict, the order of precedence is the purchase order or enquiry, then the data sheet, then this standard, and then any other standards named in the order. This matters because the pump has to be designed against one clear set of instructions.
The standard also says that any applicable national or local codes are to be agreed between purchaser and manufacturer/supplier. Clause 4 further notes that alternative designs may be offered when they meet the intent of the standard, but deviations must be clearly stated.
Performance, operating range and suction conditions
Clause 4 requires the pump to be defined by its rated conditions, allowable operating range and characteristic curve. It distinguishes normal conditions, rated conditions, operating conditions and the allowable operating range, which is limited by cavitation, heating, vibration, noise and shaft deflection.
The document places strong emphasis on net positive suction head (NPSH). It distinguishes net positive suction head available (NPSHA) from net positive suction head required (NPSHR), so the purchaser has to state the installation conditions and the supplier has to show what the pump needs to avoid cavitation.
Pressure casing, flanges, impellers and rotating parts
Clause 4 covers pressure-containing parts in detail, including pressure-temperature rating, casing thickness, corrosion allowance, gaskets, bolting and dismantling features. It also requires inlet and outlet flanges to follow the specified flange standards, with bolt-hole layout and facing details arranged so the connection is practical and robust.
The standard also addresses external forces and moments on branches. Annex B gives a method for checking piping loads against allowable flange loads, which matters because excessive piping loads can misalign the pump and driver or distort the casing.
Impellers must be secured against circumferential movement, and the design has to suit the pump type. Shaft design, shaft sleeves, shaft runout, face runout and shaft deflection are controlled so that seals and bearings can work within their limits.
Bearings, sealing and auxiliary piping
Clause 4 sets requirements for bearings, bearing housings and lubrication. Bearings have to be selected and rated for the duty, and the housing has to prevent loss or contamination of lubricant. Vertical pumps also have requirements for guide bushes and bearing spacing.
Shaft sealing is covered in detail. The standard allows soft packing, mechanical seals and multiple seal arrangements, and it links these choices to operating criteria, materials, assembly and testing. Annex F shows seal arrangement principles, and Annex G shows the related piping arrangements for circulation, injection, quench, barrier liquid and other seal services.
Auxiliary piping for cooling water, lubricating oil, vents, drains and process connections is also specified. Clause 4 sets practical requirements for size, arrangement, cleanout, protection from damage and connection identification. Annex H provides the code used to identify fluid connections on documents and on the pump itself.
Drives, baseplates and responsibilities
Clause 4 covers couplings and baseplates as part of the pump unit. It requires suitable coupling selection, service factor, guarding and, where needed, spacer arrangements for dismantling. Baseplates are addressed for both horizontal and vertical pumps, including grouting, support, alignment and accessibility.
Clause 8 assigns responsibilities clearly. The manufacturer/supplier is responsible for design, workmanship and non-defective materials, as well as satisfactory performance at the operating conditions stated in the data sheet. The purchaser is responsible for defining the operating conditions and for storage, installation, operation and maintenance.
What terms does SIST EN ISO 9905:2000 define?
- Normal conditions - the conditions under which usual operation is expected.
- Rated conditions - the specified guarantee-point operating conditions, including flow, head, power, efficiency, NPSH, suction pressure, temperature, density, viscosity and speed.
- Operating conditions - the full set of operating parameters for a given application and pumped liquid, such as temperature and pressure, that influence material selection.
- Allowable operating range - the flow range defined by the manufacturer/supplier for the specified operating conditions, limited by cavitation, heating, vibration, noise and shaft deflection.
- NPSHR (net positive suction head required) - the minimum NPSH needed for the pump to meet the specified performance at the specified flow and speed.
- Barrier liquid (buffer) - a clean, compatible liquid placed between two seals to support sealing and reduce risk if leakage occurs.
- Coupling service factor - the factor applied to the driver nominal torque to allow for torque fluctuations and achieve a suitable rated coupling torque.
Who uses SIST EN ISO 9905:2000?
SIST EN ISO 9905:2000 is used by pump manufacturers and supplier, purchasers, installation contractors, engineering consultants and plant users. It supports technical agreement, procurement, design review, inspection and acceptance for centrifugal pumps.
The introduction names oil refinery plants, chemical plants and power plants as examples of plants where Class I, Class II and Class III pumps may all be used side by side. The standard is therefore relevant wherever the pump duty, environment and reliability requirements need to be matched to the class chosen.
Which standards are used with SIST EN ISO 9905:2000?
| Standard | What it contributes |
|---|---|
| ISO 7-1 | Pipe threads where pressure-tight joints are made on the threads |
| ISO 228-1 | Pipe threads where pressure-tight joints are not made on the threads |
| ISO 76 | Static load ratings for rolling bearings |
| ISO 281 | Dynamic load ratings and rating life for rolling bearings |
| ISO 185 | Grey cast iron classification |
| ISO 1940-1 | Balance quality requirements of rigid rotors |
| ISO 2372 | Basis for vibration evaluation standards |
| ISO 2548 | Acceptance tests for centrifugal, mixed flow and axial pumps, Class C |
| ISO 2858 | End-suction centrifugal pump dimensions and nominal duty point |
| ISO 3069 | Dimensions of cavities for mechanical seals and soft packing |
| ISO 3274 | Surface roughness measurement by the profile method |
| ISO 3506 | Corrosion-resistant stainless steel fasteners |
| ISO 3555 | Acceptance tests for centrifugal, mixed flow and axial pumps, Class B |
| ISO 3744 | Sound power levels, engineering method |
| ISO 3746 | Sound power levels, survey method |
| ISO 3755 | Cast carbon steels for general engineering purposes |
| ISO 427 | Wrought copper-tin alloy composition and forms |
| ISO 544 | Filler materials for manual welding |
| ISO 4863 | Information to be supplied for resilient shaft couplings |
| ISO 7005-1 | Steel flanges |
| ISO 7005-2 | Cast iron flanges |
| ISO 7005-3 | Copper alloy and composite flanges |
| ISO 5199 | Class II centrifugal pump requirements |
| ISO 9908 | Class III centrifugal pump requirements |
What does the SIST EN ISO 9905:2000 document contain?
The document contains the full technical framework for ordering and specifying Class I centrifugal pumps, starting with the data sheet and purchase-order structure in Annexes A, C and D. It then gives design rules for the casing, impeller, shaft, bearings, sealing system, piping, coupling and baseplate, with Annex B supporting piping load checks.
It also includes inspection and test provisions for materials, hydrostatic testing, performance testing and NPSH testing. For practical use, this is the part that tells the parties what must be verified before shipment and acceptance.
The annexes add practical working material rather than repeating the main requirements. Annex F and Annex G show seal and piping arrangements, Annex H gives the connection-identification code, Annex J provides material codes for centrifugal pump parts, and Annex E gives guidance on peak displacement and vibration-related interpretation.
Relations
- Refers
SIST ISO 427:1995 - Wrought copper-tin alloys -- Chemical composition and forms of wrought products - Effective Date
- 03-Jun-2026
- Effective Date
- 03-Jun-2026
- Effective Date
- 03-Jun-2026
- Effective Date
- 03-Jun-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard
Institut za varilstvo d.o.o. (Welding Institute)
Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au
Sponsored listings
Frequently Asked Questions
SIST EN ISO 9905:2000 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Technical specifications for centrifugal pumps - Class I (ISO 9905:1994)". This standard covers: Consists of a basic text covering general requirements. The technical requirements refer only to the pump unit. Includes design features concerned with installation, maintenance and safety of such pumps, including baseplate, coupling and auxiliary piping. The selection of the class to be used is made in accordance with the technical requirements for the application for which the pump is intended. The class chosen is to be agreed between purchaser and manufacturer/supplier.
Consists of a basic text covering general requirements. The technical requirements refer only to the pump unit. Includes design features concerned with installation, maintenance and safety of such pumps, including baseplate, coupling and auxiliary piping. The selection of the class to be used is made in accordance with the technical requirements for the application for which the pump is intended. The class chosen is to be agreed between purchaser and manufacturer/supplier.
SIST EN ISO 9905:2000 is classified under the following ICS (International Classification for Standards) categories: 23.080 - Pumps. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN ISO 9905:2000 has the following relationships with other standards: It is inter standard links to SIST ISO 427:1995, SIST ISO 281:2001, SIST ISO 3506:1996, SIST ISO 76:2001, SIST EN 455-3:2007, SIST EN ISO 15535:2004, SIST EN 1434-1:1997/A1:2002, SIST EN 14015:2005, SIST EN ISO 10964:1998, SIST EN 393:1996, SIST EN ISO 11984:2000, SIST EN 539-1:2006, SIST EN 676:2004, SIST EN 14937-1:2006, SIST EN 1248:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN ISO 9905:2000 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 1.1 This International Standard covers the Class I
- 1.3 Where this International Standard specification
- 2 Normative references
- 3 Definitions
- 4 Design
- 4.1 General
- 4.2 Drivers
- 4.3 Critical speed, balance and vibration
- 4.4 Pressure-containing parts (see also 5.1)
- 4.5 Branches (nozzles) and miscellaneous
- 4.6 External forces and moments on
- 4.7 Inlet and outlet flanges and facings shaft by a cap screw or cap nut that does not expose
- 4.7.2 Good seating of the bolt head and/or nut on
- 4.9 Wear rings
- 4.10 Running clearances
- 4.11 Shaft and shaft sleeves
- 4.1 I.2 Surface roughness
- 4.11.5.2 points. However, the character of the fluid handled
- 4.12 Bearings, bearing housings and
- 4.13 Shaft sealing
- 4.14 Piping and accessories
- 4.15 Labelling
- 4.16 Couplings
- 4.17 Baseplate
- 4.17.2.3 positioning screws shall be provided for each drive
- 5 Materials
- 5.1 Selection of materials
- 4.18 Special tools
- 5.3 Welding
- 5.2 Castings
- 5.4 Material inspection
- 6.2 Inspection
- 5.5 Low temperature use
- 6 Shop inspection and tests
- 6.1 General
- 7 Preparation for dispatch
- 7.1 General standard paint or coated as specified. For the invis-
- 7.4 Securing of rotating parts for transport
- 7.2 Shaft seals
- 7.5 Openings
- 7.6 Piping and auxiliaries
- 7.3 Preparation for transport and storage
- 7.7 Identification
- 7.8 Installation instructions 8.2 The manufacturer/supplier of equipment is re-
- 8.3 The purchaser is responsible for correctly defin-
- 8.1 The manufacturer/supplier of equipment parts
- Annex A
- 7 Site conditions
- Annex B
- 1 OA’) 2)
- 11 B’)
- Annex C
- Annex D
- Annex E
- Annex F
- 02 Tandem arrangement
- 02 Main seal with throttle bush
- Annex G
- 3.5.1 Automatic pressure control valve
- 0 IS0 IS0 9905: 1994(E)
- 17 Relief valve
- 60 Apparatus
- 61 Cyclone
- 62 Cyclone with hand regulating valve
- 65 Tank with diaphragm
- 5 Motdr
- 1 Shaft-driven main oil pump 10 Piping (supply and return)
- 2 Pressure-regulating valve 11 Sight flow indicators
- 3 Full-flow filter 12 Oil reservoir
- 4 Oil cooler Auxiliary oil pump
- 5 Temperature gauge
- 14 Check valve
- 6 Pressure gauge Oil level indicator
- 7 Low-pressure alarm and shutdown switch Relief valve
- 8 Startup switch for main pump 17 Suction strainer
- 9 Auxiliary pump pressure switch Filter/Breather
- Annex H
- Annex J
Introduction
This International Standard is the second of a set dealing with technical specifications of centrifugal pumps; the specifications are designated as Classes I, II and III. Class I (this International Standard) comprises the most severe and Class III (see IS0 9908) the least severe requirements. For requirements for Class II centrifugal pumps, see IS0 5199.
The selection of the class to be used is made in accordance with the technical requirements for the application for which the pump is intended. The class chosen is to be agreed between purchaser and manufacturer/supplier.
The safety requirements of the field of application are furthermore to be taken into account.
However, it is not possible to standardize the class of technical requirements for centrifugal pumps for a certain field of application, because each field of application comprises different requirements. All classes (I, II and III) can be used in accordance with the different requirements of the pump application, e.g. for an oil refinery plant, chemical plant or power plant. It may happen that pumps built in accordance with classes I, II and III may work beside each other in one plant.
Conditions covering specific applications or industrial requirements are dealt with in separate standards.
Criteria for the selection of a pump of the class required for a certain application may be based on:
- reliability,
- operating conditions,
- environmental conditions,
- local ambient conditions.
Throughout this International Standard, text written in bold letters indicates where a decision may be required by purchaser, or where agreement is required between purchaser and manufacturer/supplier.
SIST EN ISO 9905:2000 INTERNATIONAL STANDARD Q IS0 IS0 9905: 1994(E) Technical specifications for centrifugal pumps - Class I based on this International Standard are encouraged
1 Scope
to investigate the possibility of applying the most recent editions of the standards indicated below.
1.1 This International Standard covers the Class I
Members of IEC and IS0 maintain registers of cur- (most severe) requirements for centrifugal pumps rently valid International Standards.
used in various industries. It consists of a basic text covering general requirements. The technical require- I SO 7-l : 1982, Pipe threads where pressure-tight ments refer only to the pump unit.
joints are made on the threads - Part 1: Designation, dimensions and tolerances.
Storage pumps are not included in this International Standard. A separate standard will be issued by IEC.
IS0 76: 1987, Rolling bearings - Static load ratings.
1.2 This International Standard includes design fea- IS0 185: 1988, Grey cast iron - Classification. tures concerned with installation, maintenance and IS0 228-l : 1982, Pipe threads where pressure-tight safety of such pumps, including baseplate, coupling
joints are not made on the threads - Part 1: Desigand auxiliary piping. nation, dimensions and tolerances.
1.3 Where this International Standard specification
IS0 281 :I 990, Rolling bearings - Dynamic load has been called for:
ratings and rating life.
a) and requires a specific design feature, alternative IS0 427:1983, Wrought copper-tin alloys - Chemical designs may be offered which meet the intent of composition and forms of wrought products.
this International Standard, provided that the alternative is described in detail; IS0 544: 1989, Filler materials for manual welding - Size requirements.
b) pumps not complying with all requirements of this International Standard may be offered for con- IS0 1940-l : 1986, Mechanical vibration - Balance sideration, provided that all deviations are stated.
quality requirements of rigid rotors - Part 1: Determina tion of permissible residual unbalance. IS0 2372: 1974, Mechanical vibration of machines with operating speeds from 10 to 200 rev/s - Basis for specifying evaluation standards.
2 Normative references
IS0 2548:1973, Centrifugal, mixed flow and axial The following standards contain provisions which, - Code for acceptance tests - Class C (It is pumps through reference in this text, constitute provisions planned to combine IS0 2548 with IS0 3555 during of this International Standard. At the time of publicatheir next revision to create a new lntema tional Stantion, the editions indicated were valid. All standards dard).
are subject to revision, and parties to agreements
SIST EN ISO 9905:2000 0 IS0 IS0 9905: 1994(E) 3.3 operating conditions: All operating parameters IS0 2858: 1975, End-suction centrifugal pumps (rating (for example temperature, pressure) determined by a 16 bar) - Designation, nominal duty point and digiven application and pumped liquid. mensrons.
These parameters will influence the type of con- IS0 3069: 1974, End suction centrifugal pumps - Di- struction materials.
mensions of cavities for mechanical seals and for soft packing.
3.4 allowable operating range: Flow range, de- IS0 3274:1975, Instruments for the measurement of fined by the manufacturer/supplier, at the specified surface roughness by the profile method - Contact operating conditions using the impeller supplied, as (stylus) instruments of consecutive profile transfor- limited by cavitation, heating, vibration, noise, shaft ma tion deflection and other similar criteria; range whose up- - Contact profile meters, system M.
per and lower limits are denoted by maximum and IS0 3506: 1979, Corrosion-resistant stainless steel minimum continuous flow, respectively.
fasteners - Specifications.
3.5 maximum allowable casing working IS0 3555:1977, Centrifugal, mixed flow and axial pressure: Greatest outlet pressure at the specified - Code for acceptance tests - Class B (It is pumps operating temperature for which the pump casing is planned to combine IS0 3555 with IS0 2548 during suitable.
their next revision to create a new lnterna tional Standard).
3.6 basic design pressure: Pressure derived from the permitted stress at 20 “C of the material used for IS0 374411981, Acoustics - Determination of sound the pressure-containing parts.
power levels of noise sources - Engineering methods for free-field conditions over a reflecting plane. 3.7 maximum outlet working pressure: Sum of the maximum inlet pressure plus maximum differen- IS0 374611979, Acoustics - Determination of sound tial pressure at rated conditions using the supplied power levels of noise sources - Survey method.
impeller.
IS0 3755:1991, Cast carbon steels for general engin- 3.8 rated outlet pressure: Outlet pressure of the eering purposes.
pump at the guarantee point with rated flow, rated speed, rated inlet pressure and density.
IS0 4863:1984, Resilient shaft couplings - Information to be supplied by users and manufacturers. 3.9 maximum inlet pressure: Highest inlet press- IS0 7005-I :I 992, Metallic flanges - Part 1: Steel ure to which the pump is subjected during operation.
flanges.
Inlet pressure for the 3.10 rated inlet pressure:
IS0 7005-2: 1988, Metallic flanges - Part 2: Cast iron e point.
opera ting conditions at the gu arante flanges.
3.11 maximum allowable temperature: Highest IS0 7005-3:1988, Metallic flanges - Part 3: Copper allowable continuous temperature for which the alloy and composite flanges.
equipment (or any part to which the term refers) is suitab e when handling the specified operating fluid specified operating pressure.
at the
3 Definitions
3.12 rated power input: Power required by the at the rated conditions.
Pump For the purposes of this International Standard, the following definitions apply.
3.13 maximum dynamic sealing pressure: Highest pressure expected at the shaft seals during any 31 . normal conditions: Conditions at which usua specified operating condition and during startup and operation is expected.
shutdown.
3.2 rated conditions: Specified guarantee-point op NOTE 1 Pn determining this pressure, consideration erating conditions, including flowrate, head, power, should be given to the maximum inlet pressure, circulation efficiency, net positive suction head, suction pressor injection (flush) pressure and the effect of internal clearure, temperature, density, viscosity and speed. ance changes.
SIST EN ISO 9905:2000 IS0 9905: 1994(E) 3.14 minimum permitted flow is rotated manually in its bearings in the horizontal position.
(1) for stable flow: Lowest flowrate at which the The radial face is that which determines the alignment pump can operate without exceeding the noise and of a seal component.
vibration limits imposed by this International Standard.
(2) for thermal flow: Lowest flowrate at which the 3.24 shaft deflection: Displacement of a shaft from pump can operate and still maintain the temperature its geometric centre in response to the radial hydraulic of the pumped liquid below that at which net positive forces acting on the impeller.
ing caused by impeller unbalance or shaft runout.
3.15 corrosion allowance: That portion of the wall thickness of the parts wetted by the pumped liquid in 3.25 circulation (flush): Return of pumped liquid excess of the theoretical thickness required to withfrom a high pressure area to seal cavity, by external stand the pressure limits given in 4.4.2.2 and 4.4.2.4.
piping or internal passage, to remove heat generated at the seal or to maintain positive pressure in the seal 3.16 maximum allowable continuous speed:
cavity or treated to improve the working environment Highest speed at which the manufacturer will permit for the seal.
continuous operation.
NOTE 4 In some cases it may be desirable to circulate from the seal cavity to a lower pressure area (for example, 3.17 rated speed: Number of revolutions of the the inlet).
pump per unit time required to meet the rated conditions.
3.26 injection (flush): Introduction of an appropriate NOTE 2 Induction motors will operate at a speed that is (clean, compatible, etc.) liquid into the seal cavity from a function of the load imposed.
an external source and then into the pumped liquid.
3.18 trip speed: Speed at which the independent 3.27 quenching: Continuous or intermittent introemergency overspeed device operates to shut down duction of an appropriate (clean, compatible, etc.) fluid a prime mover.
on the atmospheric side of the main shaft seal to exclude air or moisture, to prevent or clear deposits (in- 3.19 first critical speed: Speed of rotation at which cluding ice), lubricate an auxiliary seal, snuff out fire, the lowest lateral natural frequency of vibration of the dilute, heat or cool leakage. rotating parts corresponds to the frequency of rotation.
3.28 barrier liquid (buffer): An appropriate (clean, compatible, etc.) liquid inserted between two seals (mechanical seal and/or soft packing).
3.20 design radial load: Maximum hydraulic radial forces on the largest impeller (diameter and width) NOTE 5 The barrier liquid pressure depends on the seal operating within the manufacturer’s specified range arrangement. The barrier liquid may be used to prevent air on its maximum speed curve using the design liquid entering the pump. The barrier liquid is normally easier to (normally 1 000 kg/m3).
seal than the pumped liquid and/or creates less hazard if leakage occurs.
3.21 maximum radial load: Maximum hydraulic radial forces on the largest impeller (diameter and 3.29 throttle bush (safety bush): Close-clearance width) operating at any point on its maximum speed restrictive bush around the shaft (or sleeve) at the curve with a maximum liquid density.
outboard end of a mechanical seal to reduce leakage in case of seal failure.
3.22 shaft runout: Total radial deviation indicated by a device measuring shaft position in relation to the 3.30 throat bush: Close-clearance restrictive bush bearing housing as the shaft is rotated manually in its around the shaft (or sleeve) between the seal (or bearings with the shaft in the horizontal position.
packing) and the impeller.
3.23 face runout: Total axial deviation indicated at 3.31 pressure casing: Composite of all stationary the outer radial face of the stuffing box by a device pressure-containing parts of the unit, including all attached to and rotated with the shaft when the shaft branches and other attached parts.
SIST EN ISO 9905:2000 @I3 IS0 IS0 9905: 1994(E) 3.32 double casing: Type of construction in which 3.42 suction specific speed: Parameter relating the rotational speed, the flowrate and the NPSHR, deterthe pressure casing is separate and distinct from the mined at the best efficiency point.
pumping elements contained in it.
3.33 barrel casing: Refers specifically to a pump of 3.43 hydrodynamic bearing: Bearing whose surthe double casing type. face is oriented to another surface such that relative motion forms an oil wedge to support the load with- 3.34 vertical canned pump: Vertical pump inserted out metal-to-metal contact.
in an outer casing (can or caisson) taking its suction from the liquid in the annular space.
3.44 hydrodynamic radial bearing: Bearing of sleeve-journal or tilting-shoe type construction.
3.35 vertical canned motor pump: Glandless pumping set in which the stator of the (electric) motor 3.45 hydrodynamic thrust bearing: Bearing of is sealed by a can against the rotor which runs in the multiple-segment or tilting-shoe type construction.
pumped liquid or in any other liquid.
3.46 design values: Values used in the design of a 3.36 hydraulic power recovery turbine: Pump oppump for the purpose of determining the performerated with reversed flow to deliver mechanical enance, the minimum permissible wall thickness and ergy at the coupling obtained from the recovery of physical characteristics of the different parts of the energy released by the reduction of fluid pressure pump* (and sometimes from the additional energy released by vapour or gas evolution from the fluid).
NOTE 8 Use of the word design in any term (such as design pressure, design power, design temperature or de- NOTE 6 For hydraulic power recovery turbine branches, sign speed) should be avoided in the purchaser’s specifiall references in this standard to suction and discharge apply cations. This terminology should be used only by the to the outlet and inlet, respectively.
equipment designer and manufacturer/supplier.
3.37 radial split: Refers to casing joints that are 3.47 coupling service factor: A factor k, by which transverse to the shaft centreline.
is multiplied the nominal torque IQ,, of the driver in order to obtain the rated torque TK = k7’,,,, which makes 3.38 axial split: Refers to casing joints that are pardue allowance for cycle torque fluctuations from the allel to the shaft centreline.
pump and/or its driver, and therefore ensures satisfactory coupling life. 3.39 net positive suction head (NPSH): Absolute total inlet head above the head equivalent to the vapour pressure referred to the NPSH datum plane.
4 Design
NOTE 7 NPSH is referred to the datum plane, whereas inlet total head is referred to the reference plane. The NPSH
4.1 General
datum plane is the horizontal plane through the centre of the circle described by the external points of the entrance edges of the impeller blades; in the case of double inlet Whenever the documents include contradicting techpumps with vertical or inclined axis, it is the plane through nical requirements, they shall apply in the following the higher centre. The manufacturer/supplier should indicate sequence:
the position of this plane with respect to precise reference points on the pump.
iry, if no order is placed) pure hase order (or enqu a) (see annexes C and D 1; head available 3.40 net positive suction (NPSHA): NPSH determined by the conditions of the b) data sheet (see annex A); installation for a specified liquid, temperature and rate of flow.
c) this International Standard; 3.41 net positive suction head required d) other standards to which reference is made in the (NPSHR): Minimum NPSH for a pump achieving a order (or enquiry, if no order is placed).
specified performance at the specified rate of flow The applicability of any national and local codes, and speed (occurrence of visible cavitation, increase regulations, ordinances or rules shall be mutually of noise due to cavitation, appearance of head or efagreed upon by the purchaser and the manuficiency drop, head or efficiency drop of a given facturer/supplier.
amount, etc.).
SIST EN ISO 9905:2000 0 IS0 IS0 9905: 1994(E) 4.1 .l Characteristic curve in performance curves is the NPSH corresponding to a drop of 3 % of the total head of the first stage of the
4.1.1.1 The characteristic curve for the supplied
pump (NPSH3).
impeller shall show the head, efficiency, NPSHR and Should the pump manufacturer/supplier consider that, the power input, plotted against flowrate. It shall also because of the construction material and liquid show the allowable operating range of the pump.
pumped, a greater NPSH is required, this should be Headlflowrate curves (on the basis of calculation or stated in the proposal and the appropriate curve protest) for the largest and smallest impeller diameters vided.
shall be plotted for single stage pumps, and for multistage pumps when requested.
The manufacturer/supplier shall specify on the data sheet the net positive suction head required (NPSHR)
4.1.1.2 Pumps that have stable headlflowrate
when the pump is operated with water at the rated curves which continuously rise to shutoff are preflowrate and rated speed. ferred for most applications and are required when parallel operation is specified by the purchaser. Un- Hydrocarbon reduction or correction shall not be apstable headlflowrate curves or curves with dips (such plred.
as propeller pump curves) can be offered providing the application is suitable and the curve shape devi- For NPSH tests, see 6.3.5.
ations are shown. When service conditions are such that a stable curve is technically impossible, other
4.1.3 Pump design
means of ensuring the desired flow(s) must be used.
When parallel operation is specified, the rise of the
4.1.3.1 Pumping units may be of single-stage or
head at rated flowrate shall have sufficient slope to multistage design. When the rated inlet gauge pressavoid instability of flow. ure is positive or the differential pressure is more than 3,5 bar, the pump should be designed to minimize the
4.1.1.3 The best efficiency point for the supplied
pressure on the shaft seals unless thrust balance reimpeller should preferably be between the rated point quirements dictate otherwise. On single-stage overand the normal point (see 3.1). hang designs this can be accomplished with rings or pumping vanes on the back of the impeller. On
4.1.1.4 When the pump design permits a constant-
multistage pumps this can be accomplished either by speed driver, the pump shall be capable of approxi- a back-to-back impeller arrangement combined with mately a 5 % head increase at rated conditions by a close clearance throttle bush, or by an in-line installing a new larger impeller or impellers.
impeller arrangement using balance drums or discs.
4.1.1.5 Pumps that handle Newtonian liquids
Other means can be used after agreement bemore viscous than water shall have their pertween purchaser and manufacturer/supplier. formance corrected in accordance with the conversion factors to be agreed between purchaser and manufacturer/supplier. Non-Newtonian liq- 4.1.3.2 High-energy pumps (head greater than uids require special consideration. 200 m per stage and power more than 225 kW per stage) require special consideration to ensure that the
...