SIST EN IEC 60352-4:2020
(Main)Solderless connections - Part 4: Non-accessible insulation displacement (ID) connections - General requirements, test methods and practical guidance (IEC 60352-4:2020)
Solderless connections - Part 4: Non-accessible insulation displacement (ID) connections - General requirements, test methods and practical guidance (IEC 60352-4:2020)
IEC 60352-4:2020 is applicable to non-accessible ID connections for which the tests and measurements according to Clauses 6 through 8 are suitable and which are made with:
– appropriately designed ID terminations;
– wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter;
– wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-sectional area;
for use in electrical and electronic equipment and components.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions.
There are different designs and materials for ID terminations in use. For this reason, only fundamental parameters of the termination are specified, while the performance requirements of the wire and the complete connection are specified in full detail.
The purpose of this document is:
– to determine the suitability of non-accessible ID connections under specified mechanical, electrical and atmospheric conditions;
– to provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture.
This second edition cancels and replaces the first edition, published in 1994, and its Amendment 1 (2000). This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Transferred Clauses 9 to 13 into Annex A (informative).
b) The figures were re-drawn for clarity.
Lötfreie elektrische Verbindungen - Teil 4: Lötfreie nichtzugängliche Schneidklemmverbindungen - Allgemeine Anforderungen, Prüfverfahren und Anwendungshinweise (IEC 60352-4:2020)
Connexions sans soudure - Partie 4: Connexions autodénudantes, non accessibles sans soudure - Règles générales, méthodes d'essai et guide pratique (IEC 60352-4:2020)
IEC 600352-4:2020 s'applique aux connexions CAD non accessibles pour lesquelles les essais et les mesures conformes aux Articles 6 à 8 sont appropriés et qui sont composées de:
– contacts CAD de conception appropriée;
– fils à conducteurs cylindriques massifs de diamètre nominal 0,25 mm à 3,6 mm;
– fils à conducteurs divisés de section 0,05 mm2 à 10 mm2;
pour l'utilisation dans les équipements et composants électriques et électroniques.
Des informations sur les matières et des résultats dus à l'expérience industrielle y sont inclus en plus des méthodes d'essai pour assurer des connexions électriquement stables dans les conditions d'environnement prescrites.
Il y a différentes conceptions et matières utilisées pour les contacts CAD. C'est pourquoi seuls les paramètres fondamentaux du contact sont spécifiés, tandis que les exigences des performances du fil et de la connexion terminée sont définies dans tous les détails.
Le présent document a pour objet de:
– déterminer la conformité des connexions CAD non accessibles dans des conditions mécaniques, électriques et atmosphériques spécifiées;
– fournir un moyen de comparaison des résultats d'essai quand les outils utilisés pour faire les connexions, le cas échéant, sont de conceptions ou de fabrications différentes.
Cette deuxième édition annule et remplace la première édition parue en 1994, et son Amendement 1 (2000). La présente édition constitue une révision technique.
Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:
a) les Articles 9 à 13 ont été transférés à l'Annexe A (informative);
b) les figures ont été retravaillées pour plus de clarté.
Nespajkani spoji - 4. del: Nedostopni izolacijsko prebodni spoji - Splošne zahteve, preskusne metode in praktični napotki (IEC 60352-4:2020)
General Information
- Status
- Published
- Publication Date
- 02-Sep-2020
- Technical Committee
- I11 - Imaginarni 11
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 12-Aug-2020
- Due Date
- 17-Oct-2020
- Completion Date
- 03-Sep-2020
Relations
- Effective Date
- 03-Aug-2020
- Effective Date
- 03-Aug-2020
- Effective Date
- 20-Mar-2018
- Effective Date
- 20-Mar-2018
Overview - EN IEC 60352-4:2020 (Non‑accessible ID connections)
EN IEC 60352-4:2020 is the European adoption of IEC 60352-4:2020 covering solderless, non‑accessible insulation displacement (ID) connections. It specifies general requirements, test methods and practical guidance for ID terminations and the complete connection when used in electrical and electronic equipment. The standard’s scope includes ID connections made with:
- Solid round conductors nominal diameters 0.25 mm to 3.6 mm, and
- Stranded conductors with cross‑sectional areas 0.05 mm² to 10 mm².
The document focuses on producing electrically stable connections under prescribed environmental conditions and enables objective comparison of test results across different termination designs and tooling.
Key topics and requirements
- Workmanship and prerequisites: minimal functional parameters for ID terminations; detailed requirements for wire materials, dimensions, surface finishes and insulation.
- Testing framework (Clauses 6–8): standard conditions, preconditioning, specimen preparation and recovery.
- Mechanical tests: bending of cable/wire, vibration (sinusoidal), repeated connection/disconnection for reusable terminations, and microsection analysis.
- Electrical tests: contact resistance measurements (millivolt and specified current methods), electrical load and temperature endurance.
- Climatic tests: rapid temperature change, climatic sequence, flowing mixed‑gas corrosion, damp heat (cyclic) and other environmental stress tests.
- Test schedules: both basic and full test schedules, flow charts for test selection and interpretation.
- Practical guidance (Annex A, informative): materials, termination design features, tooling recommendations and current‑carrying considerations.
- Application examples (Annex B, informative): destructive and non‑destructive inspection examples, multi‑pole connector considerations.
Practical applications and users
Who benefits from EN IEC 60352-4:2020:
- Connector and terminal designers verifying ID termination concepts and materials.
- Manufacturers of electrical and electronic equipment ensuring reliable, solderless interconnections.
- Test laboratories and quality engineers performing standardized mechanical, electrical and climatic qualification.
- Procurement and compliance teams comparing supplier performance and demonstrating conformity.
Typical uses:
- Designing harnesses, wire‑to‑board or wire‑to‑connector interfaces using ID technology.
- Validating material or tooling changes (new termination alloys, plating or insertion tools).
- Establishing routine qualification or incoming inspection test plans.
Related standards
EN IEC 60352-4 references several connector and environmental test standards for measurement and conditioning context, for example:
- IEC 60228 (conductors of insulated cables)
- IEC 60068-1 (environmental testing - general)
- Several parts of IEC 60512 (connectors - tests and measurements)
EN IEC 60352-4:2020 provides the practical, test‑oriented framework needed to assess and compare non‑accessible ID connections for robust, solderless interconnection solutions.
Frequently Asked Questions
SIST EN IEC 60352-4:2020 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Solderless connections - Part 4: Non-accessible insulation displacement (ID) connections - General requirements, test methods and practical guidance (IEC 60352-4:2020)". This standard covers: IEC 60352-4:2020 is applicable to non-accessible ID connections for which the tests and measurements according to Clauses 6 through 8 are suitable and which are made with: – appropriately designed ID terminations; – wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter; – wires having stranded conductors of 0,05 mm<sup>2</sup> to 10 mm<sup>2</sup> cross-sectional area; for use in electrical and electronic equipment and components. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. There are different designs and materials for ID terminations in use. For this reason, only fundamental parameters of the termination are specified, while the performance requirements of the wire and the complete connection are specified in full detail. The purpose of this document is: – to determine the suitability of non-accessible ID connections under specified mechanical, electrical and atmospheric conditions; – to provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture. This second edition cancels and replaces the first edition, published in 1994, and its Amendment 1 (2000). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Transferred Clauses 9 to 13 into Annex A (informative). b) The figures were re-drawn for clarity.
IEC 60352-4:2020 is applicable to non-accessible ID connections for which the tests and measurements according to Clauses 6 through 8 are suitable and which are made with: – appropriately designed ID terminations; – wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter; – wires having stranded conductors of 0,05 mm<sup>2</sup> to 10 mm<sup>2</sup> cross-sectional area; for use in electrical and electronic equipment and components. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. There are different designs and materials for ID terminations in use. For this reason, only fundamental parameters of the termination are specified, while the performance requirements of the wire and the complete connection are specified in full detail. The purpose of this document is: – to determine the suitability of non-accessible ID connections under specified mechanical, electrical and atmospheric conditions; – to provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture. This second edition cancels and replaces the first edition, published in 1994, and its Amendment 1 (2000). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Transferred Clauses 9 to 13 into Annex A (informative). b) The figures were re-drawn for clarity.
SIST EN IEC 60352-4:2020 is classified under the following ICS (International Classification for Standards) categories: 29.120.20 - Connecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN IEC 60352-4:2020 has the following relationships with other standards: It is inter standard links to SIST EN 60352-4:2002/A1:2002, SIST EN 60352-4:2002, SIST EN 60352-4:2002/A1:2002, SIST EN 60352-4:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase SIST EN IEC 60352-4:2020 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-oktober-2020
Nadomešča:
SIST EN 60352-4:2002
SIST EN 60352-4:2002/A1:2002
Nespajkani spoji - 4. del: Nedostopni izolacijsko prebodni spoji - Splošne zahteve,
preskusne metode in praktični napotki (IEC 60352-4:2020)
Solderless connections - Part 4: Non-accessible insulation displacement (ID)
connections - General requirements, test methods and practical guidance (IEC 60352-
4:2020)
Lötfreie elektrische Verbindungen - Teil 4: Lötfreie nichtzugängliche
Schneidklemmverbindungen - Allgemeine Anforderungen, Prüfverfahren und
Anwendungshinweise (IEC 60352-4:2020)
Connexions sans soudure - Partie 4: Connexions autodénudantes, non accessibles sans
soudure - Règles générales, méthodes d'essai et guide pratique (IEC 60352-4:2020)
Ta slovenski standard je istoveten z: EN IEC 60352-4:2020
ICS:
29.120.20 Spojni elementi Connecting devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN IEC 60352-4
NORME EUROPÉENNE
EUROPÄISCHE NORM
July 2020
ICS 29.120.20 Supersedes EN 60352-4:1994 and all of its amendments
and corrigenda (if any)
English Version
Solderless connections - Part 4: Non-accessible insulation
displacement (ID) connections - General requirements, test
methods and practical guidance
(IEC 60352-4:2020)
Connexions sans soudure - Partie 4: Connexions Lötfreie Verbindungen - Teil 4: Nichtzugängliche
autodénudantes (CAD) non accessibles - Règles générales, Schneidklemmverbindungen - Allgemeine Anforderungen,
méthodes d'essai et guide pratique Prüfverfahren und Anwendungshinweise
(IEC 60352-4:2020) (IEC 60352-4:2020)
This European Standard was approved by CENELEC on 2020-07-16. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 60352-4:2020 E
European foreword
The text of document 48B/2804/FDIS, future edition 2 of IEC 60352-4, prepared by SC 48B "Electrical
connectors" of IEC/TC 48 "Electrical connectors and mechanical structures for electrical and electronic
equipment" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2021-04-16
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2023-07-16
document have to be withdrawn
This document supersedes EN 60352-4:1994 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Endorsement notice
The text of the International Standard IEC 60352-4:2020 was approved by CENELEC as a European
Standard without any modification.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60050-581 - International Electrotechnical Vocabulary - - -
Part 581: Electromechanical components
for electronic equipment
IEC 60068-1 - Environmental testing - Part 1: General and EN 60068-1 -
guidance
IEC 60228 - Conductors of insulated cables EN 60228 -
IEC 60512-1 - Connectors for electrical and electronic EN IEC 60512-1 -
equipment - Tests and measurements - Part
1: Generic specification
IEC 60512-1-1 - Connectors for electronic equipment - Tests EN 60512-1-1 -
and measurements - Part 1-1: General
examination - Test 1a: Visual examination
IEC 60512-2-1 - Connectors for electronic equipment - Tests EN 60512-2-1 -
and measurements - Part 2-1: Electrical
continuity and contact resistance tests -
Test 2a: Contact resistance - Millivolt level
method
IEC 60512-2-2 - Connectors for electronic equipment - Tests EN 60512-2-2 -
and measurements - Part 2-2: Electrical
continuity and contact resistance tests -
Test 2b: Contact resistance - Specified test
current method
IEC 60512-2-5 - Connectors for electronic equipment - Tests EN 60512-2-5 -
and measurements - Part 2-5: Electrical
continuity and contact resistance tests -
Test 2e: Contact disturbance
IEC 60512-6-4 - Connectors for electronic equipment - Tests EN 60512-6-4 -
and measurements - Part 6-4: Dynamic
stress tests - Test 6d: Vibration (sinusoidal)
IEC 60512-9-2 - Connectors for electronic equipment - Tests EN 60512-9-2 -
and measurements - Part 9-2: Endurance
tests - Test 9b: Electrical load and
temperature
IEC 60512-11-1 - Connectors for electrical and electronic EN IEC 60512-11-1 -
equipment - Tests and measurements - Part
11-1: Climatic tests - Test 11a - Climatic
sequence
IEC 60512-11-4 - Connectors for electronic equipment - Tests EN 60512-11-4 -
and measurements - Part 11-4: Climatic
tests - Test 11d: Rapid change of
temperature
IEC 60512-11-7 - Connectors for electronic equipment - Tests EN 60512-11-7 -
and measurements - Part 11-7: Climatic
tests - Test 11g: Flowing mixed gas
corrosion test
IEC 60512-11-9 - Connectors for electronic equipment - Tests EN 60512-11-9 -
and measurements - Part 11-9: Climatic
tests - Test 11i: Dry heat
IEC 60512-11-10 - Connectors for electronic equipment - Tests EN 60512-11-10 -
and measurements - Part 11-10: Climatic
tests - Test 11j: Cold
IEC 60512-11-12 - Connectors for electronic equipment - Tests EN 60512-11-12 -
and measurements - Part 11-12: Climatic
tests - Test 11m: Damp heat, cyclic
IEC 60352-4 ®
Edition 2.0 2020-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Solderless connections –
Part 4: Non-accessible insulation displacement (ID) connections –
General requirements, test methods and practical guidance
Connexions sans soudure –
Partie 4: Connexions autodénudantes (CAD) non accessibles –
Règles générales, méthodes d'essai et guide pratique
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.120.20 ISBN 978-2-8322-8413-1
– 2 – IEC 60352-4:2020 © IEC 2020
CONTENTS
FOREWORD . 5
INTRODUCTION . 7
1 Scope . 9
2 Normative references . 9
3 Terms and definitions . 10
4 Workmanship . 14
5 Prerequisites for basic test schedule . 14
5.1 General . 14
5.2 Prerequisites for ID terminations . 14
5.2.1 Non-accessible ID terminations materials . 14
5.2.2 Non-accessible ID terminations dimensions . 14
5.2.3 Non-accessible ID terminations surface finishes . 14
5.2.4 Non-accessible ID terminations design features . 15
5.3 Prerequisites for wires and conductors. 15
5.3.1 Wire and conductors . 15
5.3.2 Conductor materials. 15
5.3.3 Wire and conductor dimensions . 15
5.3.4 Conductor surface finishes . 15
5.3.5 Wire insulation . 15
5.4 Non-accessible insulation displacement connections (ID connections) . 16
6 Testing . 16
6.1 Overview. 16
6.2 General . 16
6.3 Standard conditions for testing . 16
6.4 Preconditioning . 16
6.5 Recovery . 17
6.6 Specimen . 17
7 Tests . 17
7.1 General examination . 17
7.2 Mechanical tests . 17
7.2.1 General . 17
7.2.2 Bending of the cable/wire . 17
7.2.3 Vibration . 18
7.2.4 Repeated connection and disconnection, reusable non-accessible
ID terminations . 19
7.2.5 Microsection . 20
7.3 Electrical tests . 21
7.3.1 General . 21
7.3.2 Contact resistance . 21
7.3.3 Electrical load and temperature . 22
7.4 Climatic tests . 22
7.4.1 General . 22
7.4.2 Rapid change of temperature . 22
7.4.3 Climatic sequence . 23
7.4.4 Flowing mixed gas, corrosion test . 23
7.4.5 Damp heat, cyclic . 23
IEC 60352-4:2020 © IEC 2020 – 3 –
8 Test schedules . 23
8.1 General . 23
8.1.1 Overview . 23
8.1.2 ID connections with terminations suitable for a range of wire diameters . 24
8.1.3 Multipole connectors . 24
8.2 Basic test schedule . 24
8.2.1 General . 24
8.2.2 Initial examination . 25
8.2.3 Testing of non-accessible ID connections . 25
8.3 Full test schedule . 26
8.3.1 General . 26
8.3.2 Initial examination . 27
8.3.3 Testing of non-accessible ID connections . 27
8.4 Flow charts . 30
Annex A (informative) Practical guidance . 33
A.1 General information on non-accessible ID connections . 33
A.1.1 General . 33
A.1.2 Advantages of non-accessible ID connections . 33
A.2 Current-carrying capacity considerations . 34
A.3 Tool information . 34
A.3.1 Wire insertion tool . 34
A.3.2 Wire extraction tool . 34
A.3.3 Combination tool . 34
A.4 Termination information . 35
A.4.1 General . 35
A.4.2 Design features . 35
A.4.3 Materials . 35
A.4.4 Surface finishes . 35
A.5 Wire information. 35
A.5.1 Type . 35
A.5.2 Dimensions . 35
A.5.3 Surface finishes . 35
A.5.4 Insulation . 35
A.5.5 Ribbon cable . 36
A.6 Connection information . 36
A.6.1 General . 36
A.6.2 ID connections made with more than one wire in one connection slot . 37
Annex B (informative) Application examples . 38
B.1 ID connections . 38
B.1.1 ID connections which can be examined by destructive inspection only . 38
B.1.2 ID connections which can be examined by non-destructive inspection . 39
B.2 General additional information about ID connections as part of a multi-pole
connector . 40
B.2.1 Mounting and bending of wire bundles/cables with contacts having ID
connections . 40
B.2.2 Mating and unmating of multipole connectors with ID contacts . 41
B.3 Examples for good transversal microsection or negative results (see
Figure B.6) . 41
B.4 Final remarks . 42
– 4 – IEC 60352-4:2020 © IEC 2020
Bibliography . 43
Figure 1 – Example of accessible and non-accessible insulation displacement
connection . 7
Figure 2 – Insulation displacement connection . 11
Figure 3 – Slot . 12
Figure 4 – Beam . 13
Figure 5 – Guiding block . 13
Figure 6 – Test arrangement, bending of the cable/wire . 18
Figure 7 – Test arrangement, vibration . 19
Figure 8 – Non-accessible ID connection made with a stranded conductor . 20
Figure 9 – Non-accessible ID connection made with a solid round conductor . 20
Figure 10 – Test arrangement, contact resistance . 21
Figure 11 – Basic test schedule (see 8.2) . 31
Figure 12 – Full test schedule (see 8.3) . 32
Figure A.1 – Example of a non-accessible ID connection with two conductors with
different cross-sections in one connection slot; wires with stranded conductors . 37
Figure B.1 – Examples of correct ID connections with closed housing design, opened
or visible by microsectioning . 38
Figure B.2 – Parts of connector housings to ensure correct ID connections (examples) . 40
Figure B.3 – Mounting of wire bundles/cables with contacts having ID connections . 40
Figure B.4 – Bending of wire bundles of connectors . 41
Figure B.5 – Mating and unmating of multipole connectors. 41
Figure B.6 – IDC: transversal microsection . 41
Table 1 – Vibration, preferred test severities . 19
Table 2 – Contact resistance of non-accessible ID connections, maximum permitted
values . 22
Table 3 – Number of specimens required . 24
Table 4 – Qualification test schedule – Test group 1 . 25
Table 5 – Qualification test schedule – Test group 2 . 26
Table 6 – Qualification test schedule – Test group 3 . 26
Table 7 – Qualification test schedule – Test group 4 . 26
Table 8 – Qualification test schedule – Test group A . 27
Table 9 – Qualification test schedule – Test group B . 28
Table 10 – Qualification test schedule – Test group C . 28
Table 11 – Qualification test schedule – Test group D . 29
Table 12 – Qualification test schedule – Test group E . 30
IEC 60352-4:2020 © IEC 2020 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
SOLDERLESS CONNECTIONS –
Part 4: Non-accessible insulation displacement (ID) connections –
General requirements, test methods and practical guidance
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC
Publication(s)"). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60352-4 has been prepared by subcommittee 48B: Electrical
connectors, of IEC technical committee 48: Electrical connectors and mechanical structures
for electrical and electronic equipment.
This second edition cancels and replaces the first edition, published in 1994, and its
Amendment 1 (2000). This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) Transferred Clauses 9 to 13 into Annex A (informative).
b) The figures were re-drawn for clarity.
– 6 – IEC 60352-4:2020 © IEC 2020
The text of this International Standard is based on the following documents:
FDIS Report on voting
48B/2804/FDIS 48B/2820/RVD
Full information on the voting for the approval of this International Standard can be found in
the report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 60352 series, published under the general title Solderless
connections, can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IEC 60352-4:2020 © IEC 2020 – 7 –
INTRODUCTION
The two following parts of IEC 60352 are available on solderless insulation displacement
connections:
– Part 3: Accessible insulation displacement (ID) connections – General requirements, test
methods and practical guidance;
– Part 4: Non-accessible insulation displacement (ID) connections – General requirements,
test methods and practical guidance.
NOTE In this document the term "insulation displacement" is abbreviated to "ID", for example "ID connection", "ID
termination".
Figure 1 illustrates examples of accessible and non-accessible insulation displacement
connections that clarify the difference among them.
Part 4 includes requirements and relevant tests (normative) as well as a practical guidance in
Annex A (informative) for non-accessible ID connections.
Two test schedules are provided:
– the basic test schedule which applies to insulation displacement connections which
conform to all prerequisites of Clause 5. It is derived from experience with successful
applications of such connections;
– the full test schedule which applies to insulation displacement connections which do not
fully conform to all prerequisites of Clause 5, for example which are manufactured using
materials or finishes not included in Clause 5.
This philosophy permits cost and time effective performance verification using a limited basic
test schedule for established insulation displacement connections and an expanded full test
schedule for connections requiring more extensive performance validation.
The suitability of the non-accessible ID connection implies that the specified requirements and
tests apply to all factors involved in producing a suitable ID connection, namely:
– the ID termination, which may be part of a single-pole or multipole connector;
– the wire (or range of wires) for which the termination is suitable;
– the tools (if any) required to produce that type of solderless connection.
The practical guidance provided in Annex A (informative) serves as a guideline for the
required workmanship. Attention is drawn to the fact that some industries (e.g. automotive,
aerospace, nuclear, military) may have specific workmanship standards and/or quality
requirements, which are outside the scope of this document.
Figure 1 – Example of accessible and non-accessible
insulation displacement connection
– 8 – IEC 60352-4:2020 © IEC 2020
IEC Guide 109 advocates the need to minimise the impact of a product on the natural
environment throughout the product life cycle.
It is understood that some of the materials permitted in this document can have a negative
environmental impact.
As technological advances lead to acceptable alternatives for these materials, they will be
eliminated from the document.
IEC 60352-4:2020 © IEC 2020 – 9 –
SOLDERLESS CONNECTIONS –
Part 4: Non-accessible insulation displacement (ID) connections –
General requirements, test methods and practical guidance
1 Scope
This part of IEC 60352 is applicable to non-accessible ID connections for which the tests and
measurements according to Clauses 6 through 8 are suitable and which are made with:
– appropriately designed ID terminations;
– wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter;
2 2
– wires having stranded conductors of 0,05 mm to 10 mm cross-sectional area;
for use in electrical and electronic equipment and components.
Information on materials and data from industrial experience is included in addition to the test
procedures to provide electrically stable connections under prescribed environmental
conditions.
There are different designs and materials for ID terminations in use. For this reason, only
fundamental parameters of the termination are specified, while the performance requirements
of the wire and the complete connection are specified in full detail.
The purpose of this document is:
– to determine the suitability of non-accessible ID connections under specified mechanical,
electrical and atmospheric conditions;
– to provide a means of comparing test results when the tools used to make the
connections, if any, are of different designs or manufacture.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their
content constitutes requirements of this document. For dated references, only the edition
cited applies. For undated references, the latest edition of the referenced document (including
any amendments) applies.
IEC 60050-581, International Electrotechnical Vocabulary – Part 581: Electromechanical
components for electronic equipment
IEC 60068-1, Environmental testing – Part 1: General and guidance
IEC 60228, Conductors of insulated cables
IEC 60512-1, Connectors for electrical and electronic equipment – Tests and measurements –
Part 1: Generic specification
IEC 60512-1-1, Connectors for electronic equipment – Tests and measurements – Part 11:
General examination – Test 1a: Visual examination
– 10 – IEC 60352-4:2020 © IEC 2020
IEC 60512-2-1, Connectors for electronic equipment – Tests and measurements – Part 21:
Electrical continuity and contact resistance tests – Test 2a: Contact resistance – Millivolt level
method
IEC 60512-2-2, Connectors for electronic equipment – Tests and measurements – Part 22:
Electrical continuity and contact resistance tests – Test 2b: Contact resistance – Specified
test current method
IEC 60512-2-5, Connectors for electronic equipment – Tests and measurements – Part 25:
Electrical continuity and contact resistance tests – Test 2e: Contact disturbance
IEC 60512-6-4, Connectors for electronic equipment – Tests and measurements – Part 64:
Dynamic stress tests – Test 6d: Vibration (sinusoidal)
IEC 60512-9-2, Connectors for electronic equipment – Tests and measurements – Part 92:
Endurance tests – Test 9b: Electrical load and temperature
IEC 60512-11-1, Connectors for electrical and electronic equipment – Tests and
measurements – Part 111: Climatic tests – Test 11a – Climatic sequence
IEC 60512-11-4, Connectors for electronic equipment – Tests and measurements – Part 114:
Climatic tests – Test 11d: Rapid change of temperature
IEC 60512-11-7, Connectors for electronic equipment – Tests and measurements – Part 117:
Climatic tests – Test 11g: Flowing mixed gas corrosion test
IEC 60512-11-9, Connectors for electronic equipment – Tests and measurements – Part 119:
Climatic tests – Test 11i: Dry heat
IEC 60512-11-10, Connectors for electronic equipment – Tests and measurements –
Part 1110: Climatic tests – Test 11j: Cold
IEC 60512-11-12, Connectors for electronic equipment – Tests and measurements –
Part 1112: Climatic tests – Test 11m: Damp heat, cyclic
3 Terms and definitions
For the purposes of this document, the terms and definition provided in IEC 60050-581 and
the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
conductor
part of the cable or wire intended to carry electric current
Note 1 to entry: The conductor may be
a) solid – made of a single strand of circular cross-section;
b) stranded – made of several strands of circular cross-section assembled either by laying up concentrically or by
bunching, and without insulation between them.
Note 2 to entry: The properties of the copper are in accordance with IEC 60228.
[SOURCE: IEC 60189-1:2018, 3.1, modified – Note 2 to entry has been added.]
IEC 60352-4:2020 © IEC 2020 – 11 –
3.2
wire
insulated conductor or assembly of several insulated conductors, laid up together and which
may be provided with a screen
Note 1 to entry: The wire may be
a) single – consists of a single insulated conductor;
b) multiple – consists of several insulated conductors.
[SOURCE: IEC 60189-1:2018, 3.2, modified – deletion of "low frequency" in the title and the
Note 2 to entry listing designations.]
3.3
insulation displacement connection
ID connection
solderless electrical connection made by inserting a single wire into a precisely controlled slot
in a termination such that the sides of the slot displace the insulation and deform the
conductor of a solid wire or the strands of a stranded wire to produce a gas-tight connection
SEE: Figure 2.
Figure 2 – Insulation displacement connection
3.3.1
accessible insulation displacement connection
accessible ID connection
ID connection in which it is possible to access test points for carrying out mechanical tests
(for example, transverse extraction force) and electrical measurements (for example, contact
resistance) without deactivation of any design feature intended to establish and/or maintain
the ID connection (see IEC 60352-3)
3.3.2
non-accessible insulation displacement connection
non-accessible ID connection
ID connection in which it is not possible to access test points for carrying out mechanical tests
such as transverse extraction force and some electrical measurements (for example, contact
resistance) without deactivation of any design feature intended to establish and/or maintain
the ID connection, mainly where the ID connection is enclosed in a component
3.4
insulation displacement termination
ID termination
termination designed to accept a wire for the purpose of establishing an ID connection
– 12 – IEC 60352-4:2020 © IEC 2020
3.4.1
reusable insulation displacement termination
reusable ID termination
ID termination that can be used more than once
3.4.2
non-reusable insulation displacement termination
non-reusable ID termination
ID termination that can be used only once
3.5
slot
specially shaped opening in an ID termination suitable to provide either connection or strain
relief
SEE: Figure 3.
Figure 3 – Slot
3.5.1
connection slot
specially shaped opening in an ID termination suitable to displace the insulation of a wire and
to ensure a gas-tight connection between the termination and the conductor(s) of the wire
Note 1 to entry: In certain cases a second connection slot is used to provide for a double connection.
3.5.2
strain relief slot
specially shaped opening in an ID termination suitable to provide for strain relief
3.6
beam
specially shaped metallic part of an ID termination on each side of the slot
IEC 60352-4:2020 © IEC 2020 – 13 –
SEE: Figure 4.
Figure 4 – Beam
3.7
apparent diameter
diameter of the circumscribing circle of the bundle of strands
3.8
guiding block
specially shaped part of a component, for example, a connector, which guides/inserts the
wire(s) into the slot(s); additionally it may provide for other mechanical features, for example,
fixing the wire(s) in correct position(s), strain relief of the ID connection(s), secondary loading
on the ID termination(s) or beams
SEE: Figure 5.
Figure 5 – Guiding block
3.9
wire insertion tool
hand or power operated tool for producing an insulation displacement connection by inserting
the wire(s) in a controlled manner to a predetermined position into the slot(s)
[SOURCE: IEC 60050-581:2008, 581-24-27]
3.10
wire extraction tool
device for extracting the wire(s) from the insulation displacement termination
[SOURCE: IEC 60050-581:2008, 581-24-28]
– 14 – IEC 60352-4:2020 © IEC 2020
4 Workmanship
The manufacturer of non-accessible ID terminations or of components (e.g. multipole
connectors) using such terminations shall provide instructions for the assembly of non-
accessible ID connections.
Non-accessible ID connections shall be processed in a careful and workmanlike manner, in
accordance with good current practice.
Annex A (informative) provides practical guidance and may constitute a benchmark for the
assessment of workmanship.
NOTE Some industry sectors (e.g. automotive, aerospace, marine, nuclear, military) use workmanship standards
which can be considered upon agreement between manufacturer and user.
5 Prerequisites for basic test schedule
5.1 General
Non-accessible ID connections which fulfil the following prerequisites, which are based on the
experience by the industry, shall be assessed in accordance with the basic test schedule.
All prerequisites are essential at the same level of importance. Non-accessible ID
connections, which do not comply with all these prerequisites but are covered by the scope of
this document, shall be assessed in accordance with the full test schedule.
5.2 Prerequisites for ID terminations
5.2.1 Non-accessible ID terminations materials
Suitable grades of copper alloy, such as copper-tin (bronze), copper-zinc (brass), etc. shall be
used.
If copper-zinc alloys are used, care should be taken regarding stress corrosion cracking
effects.
5.2.2 Non-accessible ID terminations dimensions
The quality of a non-accessible ID connection depends on the dimensions of the non-
accessible ID termination, particularly of its slot and beams, together with the characteristics
of the materials used.
The dimensions shall be chosen so as to be suitable for the wire or range of wires for which
the non-accessible ID termination is designed. The suitability is verified by applying the test
schedule given in Clauses 6 to 8.
5.2.3 Non-accessible ID terminations surface finishes
The contact area of a non-accessible ID termination shall be plated with tin or with silver,
gold, palladium or their alloys. The surface of the contact area shall be free of detrimental
contamination or corrosion.
IEC 60352-4:2020 © IEC 2020 – 15 –
5.2.4 Non-accessible ID terminations design features
Non-accessible ID terminations may be distinguished according to reusability conditions and
according to a range of wire sizes that can be accommodated. This results in the following
types:
a) reusable ID terminations, designed for one specified nominal conductor diameter or cross-
section;
b) reusable ID terminations, designed for a specified range of conductor diameters or cross-
sections;
c) non-reusable ID terminations, designed
...
記事タイトル: SIST EN IEC 60352-4:2020 - ハンダレス接続 - 第4部: アクセス不能な絶縁変位(ID)接続 - 一般的な要件、試験方法および実践的なガイダンス(IEC 60352-4:2020) 記事の内容: IEC 60352-4:2020は、特定の条件に適用される非アクセス可能なID接続に関するものであり、第6条から第8条のテストおよび計測に適したもので、次のものに使用されます: - 適切に設計されたID端子に; - 直径0.25mmから3.6mmのソリッドな丸導体を持つワイヤ; - 断面積が0.05mm2から10mm2のストランド導体を持つワイヤ; この規格には試験手順に加えて、材料および産業経験からの情報も含まれ、所定の環境条件下で電気的に安定した接続を提供します。 使用されるID端子には、異なるデザインと材料があります。そのため、端子の基本パラメータのみが規定され、ワイヤおよび完全な接続の性能要件が詳細に規定されています。 この文書の目的は次のとおりです: - 指定された機械的、電気的および大気条件下で非アクセス可能なID接続の適合性を判断すること; - 接続を作成するために使用されるツールが異なるデザインまたは製造の場合、テスト結果を比較する手段を提供すること。 この第2版は、1994年に発行された第1版およびその改訂1(2000)を取り消して置き換えるものです。この版は技術的な改訂を含んでいます。 この版には以下の重要な技術的変更が前版と比較して含まれています: a) 第9章から第13章を付録A(説明的)に移動しました。 b) 図が明確さのために再描画されました。
기사 제목: SIST EN IEC 60352-4:2020 - 피복이 없는 절연 스프링 연결 - 제4부: 접근 불가능한 절연 이동 (ID) 연결 - 일반 요구 사항, 시험 방법 및 실용 가이드 (IEC 60352-4:2020) 기사 내용: IEC 60352-4:2020은 테스트와 측정을 위한 조항 6부터 8부가 적합한 비접근 가능한 ID 연결에 적용되며, 이는 다음과 같은 것으로 이루어져 있습니다: - 적절한 디자인의 ID 부착물; - 0.25mm에서 3.6mm의 명목 직경을 가진 단선 전도체; - 0.05mm²에서 10mm²의 단면적을 가진 복선 전도체. 이는 전기 및 전자 장비 및 구성 요소에 사용되는 것입니다. 시험 절차에 추가로 산업 경험에 대한 재료 및 데이터 정보가 포함되어 있어 규정된 환경 조건에서 전기적으로 안정된 연결을 제공합니다. 사용 중인 ID 부착물에는 다양한 디자인과 재료가 있습니다. 이러한 이유로 접속 할 때만 기본 매개 변수가 지정되고 와이어와 완전한 연결의 성능 요구 사항이 자세히 설명됩니다. 이 문서의 목적은 다음과 같습니다: - 기계적, 전기적 및 대기 조건을 지정된 환경 조건으로 지정된 비접근 가능한 ID 연결의 적합성을 결정하는 것; - 접속을 만드는 데 사용되는 도구(있는 경우)가 다른 디자인 또는 제조 인 경우에도 시험 결과를 비교할 수 있는 방법을 제공하는 것. 이번 개정판은 1994년에 발표 된 초판과 그 개정안 1 (2000)을 취소합니다. 이 개정판은 기술 개정으로 구성됩니다. 이 개정판에는 다음과 같은 이전 판에 비해 중요한 기술적 변경 사항이 포함되어 있습니다: a) 조항 9에서 13을 부가 정보 아래에 있는 부록 A로 이전. b) 그림은 명확성을 위해 다시 그려졌습니다.
The article discusses the standard SIST EN IEC 60352-4:2020, which is applicable to non-accessible insulation displacement (ID) connections used in electrical and electronic equipment. The standard specifies the types of terminations and wires that can be used for these connections, and it includes test methods and guidance for creating electrically stable connections. The purpose of the standard is to determine the suitability of ID connections under specific conditions and to provide a means for comparing test results when different tools are used. This second edition of the standard replaces the previous edition published in 1994 and includes some technical revisions. These revisions include the transfer of certain clauses into an informative annex and the redrawing of figures for clarity.
제목: SIST EN IEC 60352-4:2020 - 비납땜 연결 - 제4부: 접근 불가능한 절연 배선 (ID) 연결 - 일반 요구사항, 시험 방법 및 실용적인 안내 (IEC 60352-4:2020) 기사 내용: IEC 60352-4:2020은 특정 조건에 따라 비납땜 절연 배선 (ID) 연결에 적용되며, 6장부터 8장의 시험과 측정에 적합한 것으로서 다음과 같은 제품에 사용됩니다: - 적절히 설계된 ID 종단에; - 직경 0.25mm에서 3.6mm의 솔리드 라운드 도체로 되어있는 와이어; - 단면적이 0.05mm2에서 10mm2인 연질 도체로 되어있는 와이어; 본 표준은 전기 및 전자 장비 및 부품에서 사용되는 전자적으로 안정적인 접속을 제공하기 위해 시험 절차에 추가적으로 재료 정보와 산업 경험 데이터가 포함되어 있습니다. 사용 중인 ID 종단에는 다양한 디자인과 재료가 있습니다. 이러한 이유로 종단의 기본 파라미터만 지정되고, 와이어 및 완전한 연결의 성능 요구사항은 자세히 명시됩니다. 이 문서의 목적은 다음과 같습니다: - 지정된 기계적, 전기적 및 대기 조건에 따라 비접근 가능한 ID 연결의 적합성을 결정하는 것; - 접속을 만드는 데 사용되는 도구가 다양한 디자인이나 제조일 경우 시험 결과를 비교하는 수단을 제공하는 것. 이 번째 개정판은 1994년에 발행된 첫 번째 개정판 및 그 수정본인 개정판 1(2000)을 취소하고 대체합니다. 이 개정판은 기술적 개정을 포함하고 있습니다. 이 개정판에는 다음과 같은 중요한 기술적 변경사항이 이전판과 비교하여 포함되어 있습니다: a) 9장부터 13장을 부록 A(설명적)로 이동 b) 시각적 명확성을 위해 그림을 재작성
記事のタイトル:SIST EN IEC 60352-4:2020 - ハンダ不要な接続 - 第4部:アクセスできない絶縁変位(ID)接続 - 一般的な要件、試験方法、実用的なガイダンス(IEC 60352-4:2020) 記事の内容:IEC 60352-4:2020は、特定の条件下での使用に適した非アクセス可能なID接続に適用されます。この規格では、適切に設計されたID終端と、0.25mmから3.6mmの名目直径を持つソリッドラウンド導体のワイヤ、0.05mm²から10mm²の断面積を持つストランド導体のワイヤが使用されます。また、電気機器や電子部品に使用される接続に対して、材料や産業経験からの情報が含まれており、規定された環境条件下で電気的に安定した接続を提供します。 使用されるID終端のデザインや材料は異なりますため、終端の基本的なパラメータのみが指定され、ワイヤと完全な接続の性能要件が詳細に指定されています。 この文書の目的は次のとおりです: - 指定された機械的、電気的、大気的条件下で非アクセス可能なID接続の適合性を確認すること。 - 接続に使用されるツールが異なる設計や製造でも、テスト結果を比較する手段を提供すること。 この第2版は、1994年に発行された第1版およびその改正1(2000)を置き換えるものです。この版は技術的な改訂を行っています。 この版には、以下の重要な技術的な変更が含まれます: a) 記事9から13を付属の付録Aに移行しました(情報提供)。 b) 図を明確にするために再描画しました。
The article discusses the SIST EN IEC 60352-4:2020 standard, which applies to non-accessible insulation displacement (ID) connections used in electrical and electronic equipment. The standard specifies the requirements, test methods, and practical guidance for such connections. It covers different designs and materials for ID terminations, while also specifying the performance requirements for the wire and the complete connection. The purpose of the standard is to determine the suitability of non-accessible ID connections under specific conditions and provide a means of comparing test results. This second edition of the standard includes technical revisions, such as transferring certain clauses into an informative annex and redrawing figures for clarity.










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...