oSIST prEN ISO 12625-8:2026
(Main)Tissue paper and tissue products - Part 8: Water-absorption time and water-absorption capacity, basket-immersion test method (ISO/DIS 12625-8:2026)
- Abstract
ISO 12625-8:2010 specifies a basket-immersion test method for the determination of water-absorption time and water-absorption capacity of tissue paper and tissue products.
It is expressly stated that the detection of impurities and contraries in tissue paper and tissue products be applied according to ISO 15755.
For the determination of moisture content in tissue paper and tissue products, ISO 287 is applicable.
- Status
- Not Published
- Public Enquiry End Date
- 30-Jul-2026
- Technical Committee
- VPK - Pulp, paper, board and products
- Current Stage
- 4020 - Public enquire (PE) (Adopted Project)
- Start Date
- 11-Jun-2026
- Due Date
- 29-Oct-2026
- Completion Date
- 03-Aug-2026
oSIST prEN ISO 12625-8:2026 is the Slovenian draft adoption of ISO/DIS 12625-8:2026 from the International Organization for Standardization (ISO). It specifies a basket-immersion test method for measuring water-absorption time and water-absorption capacity of tissue paper and tissue products. People use it when they need comparable absorbency results for product comparison, quality control, and trade.
What does oSIST prEN ISO 12625-8:2026 specify?
oSIST prEN ISO 12625-8:2026 specifies how to measure water-absorption time and water-absorption capacity with a basket-immersion test. The document covers the full laboratory workflow, from sampling and conditioning through manual and automated testing, to calculation and reporting.
The document is organized into:
- Scope
- Normative references
- Terms and definitions
- Principle
- Reagent
- Preparation and conditioning of the test pieces
- Manual test method
- Automated test method
- Calculation and expression of results
- Test report
- Annex A with precision data
| Annex | What it covers |
|---|---|
| Annex A | Precision from an interlaboratory round robin, including repeatability and reproducibility data for both manual and automated methods |
What are the key requirements of oSIST prEN ISO 12625-8:2026?
The core requirement in oSIST prEN ISO 12625-8:2026 is to place a prepared tissue test piece in a cylindrical basket, immerse it in water under its own weight, measure the time to complete wetting, then determine how much water the test piece retains after the defined immersion and draining times. In practice, this gives two comparable results: how fast the product wets and how much water it absorbs.
Sampling, conditioning and test pieces
Clause 6 requires sampling according to ISO 186 when evaluating a lot, and conditioning according to ISO 187. Finished roll products must have the first six and last six layers removed before test pieces are taken, because those layers may be affected by adhesive or damage. Five test pieces are prepared, each 76 mm wide and about 5.0 g, unless another size is agreed and reported.
Reagent control
Clause 5 requires deionized water with low conductivity in accordance with ISO 14487. The water temperature should stay at the same temperature used for conditioning and testing, the water is changed after each series of tests, and any temperature other than 23 °C ± 1 °C must be reported. In practice, this controls one of the biggest variables in absorbency testing: the test water itself.
Manual test method
Clause 7 defines the manual apparatus and sequence. The setup includes a water container, timer, balance, cylindrical basket, and drainage support at a 30° angle. The basket is released from a set distance above the water surface, complete wetting is observed, the sample remains submerged for 30 s, then drains for 60 s before weighing.
Automated test method
Clause 8 allows automated equipment if it reproduces the manual procedure and result quality. The automated system must weigh and record automatically, keep the basket at the correct distance from the water surface, let the basket fall freely, start timing within 1 s after complete wetting, raise the basket at a constant rate, and provide a manual override if the timer fails. This is important when a laboratory wants higher throughput but still needs results comparable with the manual method.
Calculation and reporting
Clause 9 requires the mean water-absorption time and standard deviation from five replicates, or four if one piece does not sink within 60 s. Water-absorption capacity, Wa, is reported as grams of water per gram of test piece. Clause 10 lists the report items, including the method used, conditioning atmosphere, water temperature if different, sample identification, and any deviation from the document.
What terms does oSIST prEN ISO 12625-8:2026 define?
- Absorption time - the time required for complete wetting of a sample.
- Water-absorption capacity - the mass of water absorbed per unit mass of the test piece under specified conditions.
- Test piece - the prepared sample portion used for the measurement.
- Cylindrical basket - the wire basket that holds the test piece during immersion and drainage.
- Manual test method - the operator-run procedure described in Clause 7.
- Automated test method - the instrumented procedure described in Clause 8.
- Wa - the symbol used for water-absorption capacity in the calculation.
Who uses oSIST prEN ISO 12625-8:2026?
oSIST prEN ISO 12625-8:2026 is used by test laboratories, tissue paper manufacturers, quality managers, and procurement teams that compare absorbency performance. It is also relevant for product development and incoming or outgoing quality checks, where consistent test conditions matter more than subjective judgment. The document is useful in European and international trade because it gives a common way to compare tissue products.
What changed in oSIST prEN ISO 12625-8:2026 from the previous edition?
This third edition cancels and replaces ISO 12625-8:2010, and it has been technically revised. The stated main changes are:
- addition of automated testing method options alongside the manual method
- rearrangement of different parts in 7.1
- addition of instruments in 7.2 and Annex A
- addition of 8.2 and 8.2.5
- editorial revision of the text
Which standards are used with oSIST prEN ISO 12625-8:2026?
- ISO 186 - used for sampling when evaluating a lot.
- ISO 187 - used for conditioning the test pieces and controlling the conditioning atmosphere.
- ISO 15755 - used for detecting impurities and contraries in tissue paper and tissue products.
- ISO 287 - used when moisture content of the material must be determined.
- ISO 14487 - provides the water quality reference for the deionized water used in the test.
What does the oSIST prEN ISO 12625-8:2026 document contain?
The document contains the test principle, reagent requirements, specimen preparation rules, and two complete testing routes: manual and automated. It also includes figures for the basket and drainage arrangement, plus a calculation formula for water-absorption capacity. Annex A provides precision data from a round-robin study, with tables for repeatability and reproducibility for both water-absorption time and water-absorption capacity.
Relations
- Effective Date
- 08-Jan-2025
Get Certified
Connect with accredited certification bodies for this standard

Control Union Certifications
Global certification for agriculture and sustainability.
Gozdarski inštitut Slovenije
Slovenian Forestry Institute. Forest management certification support, timber testing.
Sponsored listings
Frequently Asked Questions
oSIST prEN ISO 12625-8:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Tissue paper and tissue products - Part 8: Water-absorption time and water-absorption capacity, basket-immersion test method (ISO/DIS 12625-8:2026)". This standard covers: ISO 12625-8:2010 specifies a basket-immersion test method for the determination of water-absorption time and water-absorption capacity of tissue paper and tissue products. It is expressly stated that the detection of impurities and contraries in tissue paper and tissue products be applied according to ISO 15755. For the determination of moisture content in tissue paper and tissue products, ISO 287 is applicable.
ISO 12625-8:2010 specifies a basket-immersion test method for the determination of water-absorption time and water-absorption capacity of tissue paper and tissue products. It is expressly stated that the detection of impurities and contraries in tissue paper and tissue products be applied according to ISO 15755. For the determination of moisture content in tissue paper and tissue products, ISO 287 is applicable.
oSIST prEN ISO 12625-8:2026 is classified under the following ICS (International Classification for Standards) categories: 85.080.20 - Tissue paper. The ICS classification helps identify the subject area and facilitates finding related standards.
oSIST prEN ISO 12625-8:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 12625-8:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
oSIST prEN ISO 12625-8:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-2026
Tissue higienski papir in proizvodi iz tissue papirja - 8. del: Čas vpijanja vode in
sposobnost vpijanja vode, preskusna metoda s potopitvijo košarice (ISO/DIS
12625-8:2026)
Tissue paper and tissue products - Part 8: Water-absorption time and water-absorption
capacity, basket-immersion test method (ISO/DIS 12625-8:2026)
Tissue-Papier und Tissue-Produkte - Teil 8: Zeit für die Wasseraufnahme und
Wasseraufnahmekapazität, Korbeintauch-Prüfverfahren (ISO/DIS 12625-8:2026)
Papier tissue et produits tissues - Partie 8: Temps d'absorption d'eau et capacité
d'absorption d'eau, méthode d'essai d'immersion au panier (ISO/DIS 12625-8:2026)
Ta slovenski standard je istoveten z: prEN ISO 12625-8
ICS:
85.080.20 Tissue papir Tissue paper
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
International
Standard
ISO/DIS 12625-8
ISO/TC 6/SC 2
Tissue paper and tissue products —
Secretariat: SIS
Part 8:
Voting begins on:
Water-absorption time and water- 2026-06-05
absorption capacity, basket-
Voting terminates on:
2026-08-28
immersion test method
Papier tissue et produits tissues —
Partie 8: Temps d'absorption d'eau et capacité d'absorption
d'eau, méthode d'essai d'immersion au panier
ICS: 85.080.20
THIS DOCUMENT IS A DRAFT CIRCULATED
FOR COMMENTS AND APPROVAL. IT
IS THEREFORE SUBJECT TO CHANGE
AND MAY NOT BE REFERRED TO AS AN
INTERNATIONAL STANDARD UNTIL
PUBLISHED AS SUCH.
This document is circulated as received from the committee secretariat.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL,
TECHNOLOGICAL, COMMERCIAL AND
USER PURPOSES, DRAFT INTERNATIONAL
STANDARDS MAY ON OCCASION HAVE TO
ISO/CEN PARALLEL PROCESSING
BE CONSIDERED IN THE LIGHT OF THEIR
POTENTIAL TO BECOME STANDARDS TO
WHICH REFERENCE MAY BE MADE IN
NATIONAL REGULATIONS.
RECIPIENTS OF THIS DRAFT ARE INVITED
TO SUBMIT, WITH THEIR COMMENTS,
NOTIFICATION OF ANY RELEVANT PATENT
RIGHTS OF WHICH THEY ARE AWARE AND TO
PROVIDE SUPPORTING DOCUMENTATION.
Reference number
ISO/DIS 12625-8:2026(en)
DRAFT
ISO/DIS 12625-8:2026(en)
International
Standard
ISO/DIS 12625-8
ISO/TC 6/SC 2
Tissue paper and tissue products —
Secretariat: SIS
Part 8:
Voting begins on:
Water-absorption time and water-
absorption capacity, basket-
Voting terminates on:
immersion test method
Papier tissue et produits tissues —
Partie 8: Temps d'absorption d'eau et capacité d'absorption
d'eau, méthode d'essai d'immersion au panier
ICS: 85.080.20
THIS DOCUMENT IS A DRAFT CIRCULATED
FOR COMMENTS AND APPROVAL. IT
IS THEREFORE SUBJECT TO CHANGE
AND MAY NOT BE REFERRED TO AS AN
INTERNATIONAL STANDARD UNTIL
PUBLISHED AS SUCH.
This document is circulated as received from the committee secretariat.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL,
© ISO 2026
TECHNOLOGICAL, COMMERCIAL AND
USER PURPOSES, DRAFT INTERNATIONAL
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
STANDARDS MAY ON OCCASION HAVE TO
ISO/CEN PARALLEL PROCESSING
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
BE CONSIDERED IN THE LIGHT OF THEIR
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
POTENTIAL TO BECOME STANDARDS TO
WHICH REFERENCE MAY BE MADE IN
or ISO’s member body in the country of the requester.
NATIONAL REGULATIONS.
ISO copyright office
RECIPIENTS OF THIS DRAFT ARE INVITED
CP 401 • Ch. de Blandonnet 8
TO SUBMIT, WITH THEIR COMMENTS,
CH-1214 Vernier, Geneva
NOTIFICATION OF ANY RELEVANT PATENT
Phone: +41 22 749 01 11
RIGHTS OF WHICH THEY ARE AWARE AND TO
PROVIDE SUPPORTING DOCUMENTATION.
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland Reference number
ISO/DIS 12625-8:2026(en)
ii
ISO/DIS 12625-8:2026(en)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 1
5 Reagent . 2
6 Preparation and conditioning of the test pieces . 2
6.1 Sampling .2
6.2 Conditioning.2
6.3 Preparation of test pieces .2
7 Manual test method . 2
7.1 Apparatus .2
7.2 Procedure .3
8 Automated test method . 4
8.1 Apparatus .4
8.1.1 General .4
8.2 Requirements .5
8.3 Procedure .6
9 Calculation and expression of results . 6
9.1 Water-absorption time .6
9.2 Water-absorption capacity .6
10 Test report . 7
Annex A (informative) Precision . 8
Bibliography .12
iii
ISO/DIS 12625-8:2026(en)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 6, Paper, board and pulps, Subcommittee SC 2,
Test methods and quality specifications for paper and board.
This third edition cancels and replaces the second edition (ISO 12625-8:2010) which has been technically
revised.
The main changes are as follows:
— Addition of automated testing method options, besides the manual testing approach;
— Rearrangements of different parts in 7.1;
— Addition of instruments in 7.2 and Annex A;
— Addition of 8.2 and addition of 8.2.5;
— Editing of the text.
A list of all parts in the ISO 12625 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
iv
ISO/DIS 12625-8:2026(en)
Introduction
This part of ISO 12625 describes a principle for the determination of water-absorption properties of tissue
paper and tissue products, a principle in which sheets of the sample are inserted in a cylindrical basket,
which is immersed in water. The results are expressed as
— water-absorption time, and
— water-absorption capacity.
In European and international trade, both water-absorption time and water-absorption capacity represent
important parameters in the field of comparison of tissue products.
v
DRAFT International Standard ISO/DIS 12625-8:2026(en)
Tissue paper and tissue products —
Part 8:
Water-absorption time and water-absorption capacity,
basket-immersion test method
1 Scope
This part of ISO 12625 specifies a basket-immersion test method for the determination of water-absorption
time and water-absorption capacity of tissue paper and tissue products.
It is expressly stated that the detection of impurities and contraries in tissue paper and tissue products be
[1]
applied according to ISO 15755 .
[2]
For the determination of moisture content in tissue paper and tissue products, ISO 287 is applicable.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 186, Paper and board — Sampling to determine average quality
ISO 187, Paper, board and pulps — Standard atmosphere for conditioning and testing and procedure for
monitoring the atmosphere and conditioning of samples
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at http:// www .electropedia .org/
3.1
absorption time
time required for complete wetting of a sample
3.2
water-absorption capacity
mass of water that is absorbed per unit mass of the test piece under specified conditions
4 Principle
A test piece of the tissue paper or a tissue product is placed in a cylindrical basket and allowed to immerse
in water under its own weight.
The time required for complete wetting of the test piece is measured, the mass of water absorbed then being
determined after a stated immersion time followed by a given draining time, under specified conditions.
ISO/DIS 12625-8:2026(en)
5 Reagent
5.1 Deionized water, with a conductivity ≤0,25 mS/m at 25 °C, in accordance with ISO 14487. The water
temperature should be maintained during the test at the temperature used for conditioning and testing. To
avoid interference due to contamination of the water from previous test pieces, change the water after each
series of tests. If temperature is different from 23 °C (+/- 1 °C), then water temperature shall be included in
the test report.
6 Preparation and conditioning of the test pieces
6.1 Sampling
If the tests are being made to evaluate a lot, select the sample in accordance with ISO 186. When sampling
finished roll products, eliminate at least the first six layers and the last six layers because of the possible
presence of adhesive or mechanical damage.
If the tests are made on another type of sample, make sure that the test pieces taken are representative of
the sample received.
6.2 Conditioning
Condition the test pieces in accordance with ISO 187, prepare and test the pieces under the same condition.
6.3 Preparation of test pieces
From the sample, prepare five test pieces by cutting test pieces of (76 ± 1) mm w
...