Thermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification

This European Standard specifies the requirements for factory made products of extruded polystyrene foam, with or without facings or coatings, which are used for thermal insulation of buildings. The products are manufactured in the form of boards which are also available with special edge and surface treatment (tongue & grooves, shiplap etc.).
Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
The standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m²K/W or a declared thermal conductivity greater than 0,060 W/(mK) at 10 C are not covered by this standard.
This standard does not cover in situ insulation products, nor products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14307), or civil engineering applications (covered by EN 14934).

Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus extrudiertem Polystyrolschaum (XPS) - Spezifikation

Diese Europäische Norm legt die Anforderungen an werkmäßig hergestellte Produkte aus extrudiertem Polystyrolschaum mit oder ohne Kaschierung oder Beschichtung fest, die für die Wärmedämmung von Gebäuden benutzt werden. Die Produkte werden in Form von Platten hergestellt. Sie sind ebenso mit besonderer Kanten  oder Oberflächenausbildung verfügbar (Nut- und Federausbildung, Stufenfalz usw.).
Die in dieser Norm beschriebenen Produkte werden auch in vorgefertigten Wärmedämmsystemen und Mehrschicht Platten angewendet. Die Eigenschaften von Systemen, in die diese Produkte integriert sind, werden nicht behandelt.
Die vorliegende Norm beschreibt die Produkteigenschaften und enthält die Prüfverfahren und Festlegungen für die Konformitätsbewertung, die Kennzeichnung und die Etikettierung.
Diese Norm legt keine Leistungsstufen für eine vorgegebene Eigenschaft fest, die ein Produkt erreichen muss, um für einen bestimmten Anwendungsfall tauglich zu sein. Die für bestimmte Anwendungen benötigten Stufen können Regelwerken oder nicht entgegenstehenden Normen entnommen werden.
Diese Norm gilt nicht für Produkte, deren Nennwert des Wärmedurchlasswiderstandes niedriger als 0,25 m2K/W oder deren Nennwert der Wärmeleitfähigkeit größer als 0,060 W/(mK) bei 10 °C ist.
Diese Europäische Norm gilt weder für in situ Dämmprodukte noch für Produkte, die zur Dämmung von haustechnischen oder betriebstechnischen Anlagen (durch EN 14307 abgedeckt) oder für die Anwendung im Tiefbau (durch EN 14934 abgedeckt) vorgesehen sind.

Produits isolants thermiques pour le bâtiment - Produits manufacturés en mousse de polystyrène extrudé (XPS) - Spécification

La présente Norme européenne spécifie les exigences auxquelles doivent satisfaire les produits manufacturés en mousse de polystyrène extrudé, avec ou sans parements ou enduits de finition, utilisés pour l'isolation thermique des bâtiments. Les produits sont fabriqués sous forme de panneaux qui sont également disponibles avec traitement spécial de leurs chants et surfaces (tenon et mortaise, feuillure, etc.).
La présente norme inclut les panneaux isolants XPS multicouches dont les couches sont perpendiculaires aux chants du panneau, c'est-à-dire parallèles à la surface du panneau final.
Les produits couverts par la présente norme sont également utilisés dans des systèmes d'isolation thermique et dans des panneaux composites préfabriqués ; les performances des systèmes incorporant ces produits ne sont pas définies.
La présente norme décrit les caractéristiques des produits et contient des modes opératoires d'essai, d'évaluation de la conformité, de marquage et d'étiquetage. La présente norme ne spécifie pas, pour une propriété donnée, le niveau exigé que doit atteindre un produit pour démontrer son aptitude à l'emploi dans une application particulière. Les niveaux requis pour une application donnée figurent dans les réglementations ou normes non contradictoires.
Les produits dont la résistance thermique déclarée à une température de 10 °C est inférieure à 0,25 m2 K/W ou dont la conductivité thermique déclarée à une température de 10 °C est supérieure à 0,060 W/(m×K) ne relèvent pas du domaine d'application de la présente norme.
Les produits isolants mis en œuvre in situ, ceux destinés à être utilisés pour l'isolation des équipements du bâtiment et des installations industrielles (couverts par l’EN 14307) ou ceux destinés à des applications de génie civil (couverts par l’EN 14934) ne relèvent pas du domaine d'application de la présente norme.

Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekstrudiranega polistirena (XPS) - Specifikacija

Ta evropski standard določa zahteve za površinsko obdelane ali lakirane ali površinsko neobdelane ali nelakirane proizvode iz ekstrudiranega polistirena, ki se uporabljajo za toplotno izolacijo stavb. Proizvodi so izdelani v obliki plošč, ki so na voljo tudi s posebno obdelavo robov in površine (jezički in utori, prekrivni deli itd.).
Proizvodi iz tega standarda se uporabljajo tudi v predizdelanih sistemih toplotne izolacije in vezanih ploščah; lastnosti sistemov iz teh proizvodov niso opisane.
Ta standard opisuje lastnosti proizvodov ter zajema postopke za preskušanje, vrednotenje skladnosti, označevanje in etiketiranje.
Standard ne določa zahtevane ravni določene lastnosti, ki jo mora proizvod doseči, da se dokaže njegova primernost namenu za posamezno vrsto uporabe. Zahtevane ravni za posamezno uporabo so določene v uredbah ali standardih, ki niso v nasprotju s tem standardom.
Proizvodi z deklarirano toplotno upornostjo, nižjo od 0,25 m² K/W, ali deklarirano toplotno prevodnostjo, višjo od 0,060 W/(mK) pri 10 °C, v tem standardu niso zajeti.
Ta standard ne zajema izolacijskih proizvodov, izdelanih na kraju samem, ali proizvodov za izolacijo gradbene opreme in industrijskih napeljav (zajema jih standard EN 14307) ali proizvodov za inženirske objekte (zajema jih standard EN 14934).

General Information

Status
Published
Publication Date
18-Mar-2015
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
27-Feb-2015
Due Date
04-May-2015
Completion Date
19-Mar-2015

Relations

Standard
SIST EN 13164:2013+A1:2015
English language
50 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekstrudiranega polistirena (XPS) - SpecifikacijaWärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus extrudiertem Polystyrolschaum (XPS) - SpezifikationProduits isolants thermiques pour le bâtiment - Produits manufacturés en mousse de polystyrène extrudé (XPS) - SpécificationThermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 13164:2012+A1:2015SIST EN 13164:2013+A1:2015en,fr,de01-april-2015SIST EN 13164:2013+A1:2015SLOVENSKI
STANDARDSIST EN 13164:20131DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13164:2012+A1
February 2015 ICS 91.100.60 Supersedes EN 13164:2012English Version
Thermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification
Produits isolants thermiques pour le bâtiment - Produits manufacturés en mousse de polystyrène extrudé (XPS) - Spécification
Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus extrudiertem Polystyrolschaum (XPS) - Spezifikation This European Standard was approved by CEN on 6 October 2012 and includes Amendment 1 approved by CEN on 15 December 2014.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13164:2012+A1:2015 ESIST EN 13164:2013+A1:2015

Determination of the declared values of thermal resistance and thermal conductivity . 24 A.1 General . 24 A.2 Input data . 24 SIST EN 13164:2013+A1:2015

!Product type determination" (!PTD") and Factory production control (FPC) . 26 Annex C (normative)
Determination of the aged values of thermal resistance and thermal conductivity . 30 C.1 General . 30 C.2 Procedure for XPS foam without diffusion tight facings . 30 C.2.1 Principle. 30 C.2.2 Sample preparation . 30 C.2.3 Procedure . 30 C.3 Procedure for XPS foam for use with diffusion tight facing on both sides . 31 C.3.1 Principle. 31 C.3.2 Ageing procedure . 31 C.4 Determination of value after ageing: “aged value” . 31 C.4.1 Determination of aged value for XPS products without diffusion tight facings on both sides . 31 C.4.2 Determination of aged value for XPS products for use with diffusion tight facing on both sides . 32 C.5 Blowing agent . 33 C.6 Product grouping . 33 Annex D (normative)
XPS multi-layered insulation products . 34 D.1 General . 34 D.2 Requirements . 34 D.2.1 For all applications . 34 D.2.2 For specific applications . 35 D.3 Test methods . 35 D.4 Evaluation of conformity . 35 Annex E (informative)
Additional properties . 36 E.1 General . 36 E.2 Behaviour under cyclic loading . 36 E.3 Compressive modulus of elasticity . 36 E.4 Bending strength . 36 E.5 Determination of volume percentage of closed cells . 36 Annex F (informative)
Plan for cutting test specimen . 38 Annex ZA (informative)
!Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation" . 40 ZA.1 Scope and relevant characteristics . 40 SIST EN 13164:2013+A1:2015

Tables Table 1 — Tolerances of length, width, squareness and flatness . 13 Table 2 — Classes for thickness tolerances . 13 Table 3 — Dimensional stability under specified conditions . 14 Table 4 — Levels for deformation under specified compressive load and temperature conditions . 15 Table 5 — Levels for compressive stress or compressive strength . 15 Table 6 — Levels for tensile strength, perpendicular to faces . 16 Table 7 — Levels for long term water absorption by total immersion . 16 Table 8 — Levels for long term water absorption by diffusion . 17 Table 9 — Test methods, test specimens and conditions. 19 Table A.1 — Values for k for one sided 90 % tolerance interval with a confidence level of 90 % . 25 Table B.1 — Minimum number of tests for !PTD" and minimum product testing frequencies . 26 Table B.2 – Minimum product testing frequencies for the reaction to fire characteristics . 28 Table E.1 — Test methods, test specimens, conditions and minimum testing frequencies . 37 Table ZA.1 — Relevant clauses for factory made extruded polystyrene foam and intended use . 40 Table ZA.2 — Systems of AVCP . 42 Table ZA.3.1 — Assignment of AVCP tasks for factory made extruded polystyrene foam products under system 1 for reaction to fire and system 3 (see Table ZA.2) . 42 Table ZA.3.2 — Assignment of AVCP tasks for factory made extruded polystyrene foam products under system 3 (see Table ZA.2) . 44 Table ZA.3.3 — Assignment of AVCP tasks for factory made extruded polystyrene foam products under combined system 4 for reaction to fire and system 3 (see Table ZA.2) . 44 Figures Figure ZA.1 — Example CE marking information of products under AVCP system 3" . 49
is the water vapour diffusion resistance factor -- n is the number of test results – R90/90 is the 90 % fractile with a confidence level of 90 % for the thermal resistance m2„K/W R90/90, 60d is the 90 % fractile with a confidence level of 90 % for the thermal resistance of foam at 60 days m2„K/W R90/90>60d is the 90 % fractile with a confidence level of 90 % for the thermal resistance of foam older than 60 days m2„K/W RD is the declared thermal resistance m2„K/W Ri is one test result of thermal resistance m2„K/W Rmean is the mean thermal resistance m2„K/W Sb is the deviation from squareness on width or length mm/m Smax is the deviation from flatness mm sR is the estimate of the standard deviation of the thermal resistance m2„K/W s is the estimate of the standard deviation of the thermal conductivity W/(m„K) s is the estimate of the standard deviation of the aged thermal conductivity W/(m„K) s is the estimate of the standard deviation of the initial thermal conductivity within 90 days of production W/(m„K) k10 is the compressive stress at 10 % deformation kPa kc is the declared compressive stress kPa km is the compressive strength kPa kmt is the tensile strength perpendicular to faces kPa τ is the shear strength kPa WdV is the water absorption by diffusion % Wlt is the long-term water pick up by total immersion % WV is the water absorption by diffusion and by freeze-thaw % Xct is the compressive creep mm Xt is the total thickness reduction at time t mm SIST EN 13164:2013+A1:2015

CC(i1/i2/y)1c is the symbol of the declared level for compressive creep CS(10\Y) is the symbol of the declared level for compressive stress or strength DLT(1)5 is the symbol of the declared level of deformation under specified compressive load, temperature and time conditions with a maximum of 5 % deformation DLT(2)5 is the symbol of the declared level of deformation under specified compressive load, temperature and time conditions with a maximum of 5 % deformation DS(70,-) is the symbol of the declared value for dimensional stability at specified temperature DS(23,90); DS(70,90) is the symbol of the declared value for dimensional stability under specified temperature and humidity conditions FTCD is the symbol of the declared level for freeze thaw resistance after water diffusion test FTCI is the symbol of the declared level for freeze thaw resistance after water vapour immersion test MU is the symbol of the declared level for water vapour diffusion resistance factor SS is the symbol of the declared value for shear strength T is the symbol of the declared class for thickness tolerances TR is the symbol of the declared level for tensile strength perpendicular to faces WD(V) is the symbol of the declared level for water absorption by diffusion WL(T) is the symbol of the declared level for long term water absorption by total immersion Z is the symbol of the declared value for water vapour resistance Abbreviated terms used in this standard: XPS is eXtruded PolyStyrene foam !PTD is Product Type Determination (previously named ITT for Initial Type Test)" FPC is Factory Production Control RtF is the Reaction to Fire !AVCP is Assessment and Verification of Constancy of Performance (previously named attestation of conformity) DoP is Declaration of Performance ThIB is Thermal Insulation for Buildings VCP is Verification of Constancy of Performance (previously named evaluation of conformity)" 4 Requirements 4.1 General Product properties shall be assessed in accordance with Clause 5. To comply with this standard, products shall meet the requirements of 4.2, and the requirements of 4.3 as appropriate. For multi-layered products, additional requirements are given in Annex D. One test result for a product property is the average of the measured values on the number of test specimens given in Table 9. SIST EN 13164:2013+A1:2015

Annex C and declared by the manufacturer according to the following: — the reference mean temperature shall be 10 °C; — the measured values shall be expressed with three significant figures; — for products of uniform thickness, the declared thermal resistance, RD, shall always be declared. The D, shall be declared where possible. Where appropriate, for the products of non-D, shall be declared; — the declared thermal resistance, RDD, shall be given as limit values representing at least 90 % of the production, determined with a confidence level of 90 %; — 90/90, shall be rounded upwards to the nearest 0,001 W/(m„K) D in levels with steps of 0,001 W/(m„K); — the declared thermal resistance, RD, shall be calculated from the nominal thickness, d N ,and the 90/90; unless measured directly; — the statistical value of thermal resistance, R90/90, when calculated from the nominal thickness, d N , and the 90/90, shall be rounded downwards to the nearest 0,05 m²„K/W, and declared as RD in levels with steps of 0,05 m²„K/W; — the statistical value of thermal resistance, R90/90, for those products for which only the thermal resistance is measured directly, shall be rounded downwards to the nearest 0,05 m²„K/W and declared as RD in levels with steps of 0,05 m²„K/W. NOTE U and, RU (design values) may be determined with reference to EN ISO 10456. 4.2.2 Length, width, squareness, flatness Length, l, and width, b, shall be determined in accordance with EN 822, the deviation from squarenesses on length and width, Sb, in accordance with EN 824, and the deviation from flatness, Smax, in accordance with EN 825. No test result shall deviate from the nominal values by more than the tolerances given in Table 1. SIST EN 13164:2013+A1:2015

Tolerances Length or width Squareness on length and width Flatness mm mm Sb mm/m Smax mm/m l or b ≤=k500=mm l or b > 1500 mm ± 8 ± 10 5 5 6 6 4.2.3 Thickness Thickness, d, shall be determined in accordance with EN 823. No test result shall deviate from the nominal thickness, d N, by more than the tolerances given in Table 2 for the declared class. Table 2 — Classes for thickness tolerances Class Tolerances mm Thickness mm T1 -2 -2 -2 +2 +3 + 6 < 50 50=≤=dN ≤=k20 > 120 T2 -1,5 -1,5 -1,5 +1,5 +1,5 +1,5 < 50 50=≤=dN ≤=k20 > 120 T3 -1 -1 -1 +1 +1 +1 < 50 50=≤=dN ≤=k20 > 120 NOTE T2 and T3 classes are only applicable to planed XPS products, i.e. with their extrusion skin removed. 4.2.4 Reaction to fire of the product as placed on the market Reaction to fire classification of the product as placed on the market shall be determined in accordance with EN 13501-1 and the mounting and fixing rules given in EN 15715. This classification is compulsory and shall always be included in the CE Marking label. Detailed information about the test conditions and the field of application of the classification as stated in the reaction to fire classification report shall be given in the manufacturer literature. 4.2.5 Durability characteristics 4.2.5.1 General The appropriate durability characteristics have been considered and are covered in 4.2.5.2, 4.2.5.3 and where appropriate in 4.3.6 on compressive creep. SIST EN 13164:2013+A1:2015

WD(V)1 ≤=k WD(V)2 ≤=2 WD(V)3 ≤=3 WD(V)4 ≤=4 WD(V)5 ≤=5 4.3.8 Freeze-thaw resistance 4.3.8.1 General Freeze-thaw resistance after water absorption by diffusion or total immersion shall be determined in accordance with EN 12091. After the followed 300 freeze-thaw cycling test the reduction in compressive stress at 10 %=deformation,=k
...