SIST EN 301 401 V1.2.6:2004
(Main)Attachment requirements for Data Terminal Equipment (DTE) to connect to public networks that have physical and electrical network presentations based upon the ITU-T V-series of Recommendations
- Abstract
(Provisional) Attachment requirements for Data Terminal Equipment (DTE) to connect to physical and electrical network presentations that are based upon the ITU-T V Series of Recommendations. This TBR will combine and harmonize the requirements of TBR 1 and TBR 2. The TBR will contain all requirements deemed essential under Directive 91/263/EEC to approve terminals within this category regardless of the protocols transported accross such interfaces. In particular, the TBR will contain requirements for connection to V.10, V.11, V.12, V.28, V.35, and V.36 network presentations and will supercede TBR 1 and TBR 2. Reference documents: TBR 1, TBR 2, ITU-T Recommendations V.10, V.11, V.12, V.28, V.35 and V.36
- Status
- Published
- Publication Date
- 30-Sep-2004
- Technical Committee
- RES - Radio equipment and systems
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Oct-2004
- Due Date
- 01-Oct-2004
- Completion Date
- 01-Oct-2004
- Mandate
- T-237A
SIST EN 301 401 V1.2.6:2004 is the Slovenian adoption of ETSI EN 301 401 V1.2.6 for Data Terminal Equipment (DTE) that connects to public networks using ITU-T V-series physical and electrical interfaces. It specifies the connector arrangements, circuit assignments, electrical limits and test methods used to assess DTE that attaches to those network presentations.
What does SIST EN 301 401 V1.2.6:2004 specify?
SIST EN 301 401 V1.2.6:2004 specifies the technical characteristics for DTE interfaces to public networks presented at V.10, V.11, V.12, V.24/V.28, V.35 or V.36, regardless of data rate. In practice, it tells a manufacturer or test lab what the DTE must present at the public network interface so the terminal does not disturb the network.
The document applies to DTE used with circuit switched, packet switched, leased circuit, frame relay and SMDS services, plus other services presented on the same electrical interfaces. It is organized into clauses on scope, references, definitions, safety and EMC context, applicability, electrical/mechanical requirements, and test specification, followed by two normative annexes.
| Annex | What it covers |
|---|---|
| Annex A | Requirements Table (RT), including requirement status, connector options, circuit assignments and test selection support |
| Annex B | Physical layer implementation extra information for testing (PIXIT) |
What are the key requirements of SIST EN 301 401 V1.2.6:2004?
Interface scope and connector choice
Clause 5 and clause 6 tie the standard to specific DCE interface presentations and connector families. The DTE may use one of six connector types: 25-pole, 26-pole, 37-pole, 34-pole, 15-pole or 50-pole. For a buyer or designer, this means the mechanical interface is part of the compliance decision, not just the signal behavior.
Clause 6.2 also allows a manufacturer to declare an alternative means of connection in a format similar to the RT in Annex A. That matters when a product uses a proprietary connector or wiring scheme, because the implementation has to be documented and assessed against the same kind of requirement structure.
Circuit assignments depend on the DCE electrical presentation
Annex A shows that the required circuits change with the DCE type and connector type. For example, the 26-pole and 37-pole options distinguish between V.10/V.11 presentations and V.28 presentations, while the 15-pole connector is used for V.10 or V.11 and the 50-pole connector is used for V.12.
In practice, this means pin numbering and signal labeling have to match the declared network interface. The RT in Annex A is the place where the manufacturer states which mandatory and optional circuits are implemented.
Electrical limits are set by interface family
Clause 6.3 defines the generator electrical requirements for the main interchange circuit families. The standard gives separate open-circuit output voltage limits for V.10, V.11, V.12, V.28 and V.35, and it treats V.36 as using V.10 and/or V.11 characteristics as declared by the manufacturer.
This is important because the lab does not test a generic serial output. It tests the specific electrical family used by each signal, using the setup shown in the clause 7 figures.
Test conditions are controlled and repeatable
Clause 7.1 fixes the test environment, power conditions and test point. Tests are performed at 15 °C to 35 °C and 5 % to 75 % relative humidity, with the terminal powered on, and measurements are made at the DCE connection point. The applicant may need to provide representative cabling, bit patterns and Signal Element Timing.
That matters because the standard checks the real interface as used, not just a bench-top board. The test lab also relies on the declaration of which circuits are identically implemented and which generator states are fixed in operation.
Conformance uses both testing and declared implementation data
Clause 7.1.8 allows electrical characteristics to be verified by the listed tests or, by agreement, by a declaration of conformance with supporting design evidence. Annex B then captures extra implementation information needed for testing.
For a quality manager, this means conformance is not only a lab measurement exercise. It also depends on complete implementation data in the RT and PIXIT forms.
Test groups are selected from the declared support
Clauses 7.8 and 7.9 define the test selection expressions and the test case index. The RT entries drive which connector tests and which generator-voltage tests apply to a particular implementation.
What terms does SIST EN 301 401 V1.2.6:2004 define?
- Data Terminal Equipment (DTE) - the terminal equipment covered by the standard, intended to connect to a public network interface.
- Data Circuit terminating Equipment (DCE) - the network-side equipment or interface that the DTE connects to.
- Packet Switched Public Data Network (PSPDN) - the packet-switched public data network referenced in the definitions.
- Requirements Table (RT) - the proforma that records which requirements are mandatory, optional or conditional for a specific implementation.
- Implementation Under Test (IUT) - the specific product sample being checked during testing.
- Physical layer implementation extra information for testing (PIXIT) - the annex B form used to capture implementation details relevant to testing.
- open-circuit generator voltage (Vo) - the voltage quantity measured in the electrical tests.
Who uses SIST EN 301 401 V1.2.6:2004?
Manufacturers of DTE use SIST EN 301 401 V1.2.6:2004 when designing public-network interfaces, choosing connector types and assigning circuits. Test laboratories and conformity assessors use it to plan connector checks, voltage measurements and static conformance review.
Quality managers and buyers use it to confirm that a terminal is intended for the required V-series interface family, such as V.10, V.11, V.12, V.28, V.35 or V.36. It is also relevant where procurement or certification needs a clear statement of the declared interface presentation.
What changed in SIST EN 301 401 V1.2.6:2004 from the previous edition?
SIST EN 301 401 V1.2.6:2004 combines and harmonizes the requirements of TBR 1 and TBR 2. It supersedes both documents for this category of DTE attachment requirements.
Which standards are used with SIST EN 301 401 V1.2.6:2004?
- Council Directive 98/13/EEC - the regulatory basis for terminal equipment conformity and the essential requirements referenced by the RT.
- Council Directive 73/23/EEC and Council Directive 89/336/EEC - the safety and EMC directives referenced in the references section.
- ISO 2110, ISO/IEC 11569, ISO 4902, ISO 2593, ISO 4903 and TIA/EIA-613 - connector dimensions, mating form and contact numbering for the supported connector types.
- ITU-T V.10, V.11, V.12, V.24, V.28 and V.36 - the electrical characteristics and interchange-circuit definitions used by the interface tests.
- CCITT V.35 - the balanced interchange-circuit characteristics used for one connector family.
- ITU-T X.21, X.21 bis, X.25, X.2, X.26 and X.27 - the service and interface context used in the scope and definition sections.
- TBR 1 and TBR 2 - the predecessor requirements combined by this standard.
What does the SIST EN 301 401 V1.2.6:2004 document contain?
The document includes conformance tables in Annex A, with connector options, circuit-by-circuit assignments, conditional requirement logic and test selection expressions. It also includes test figures and procedures for generator voltage checks and connector checks in clauses 7.2 to 7.7.
Annex A is the main implementation record for static assessment and test case selection, while Annex B records extra implementation information needed by the test lab. The body of the standard also gives the measurement setups for the electrical tests, so the lab can reproduce the same interface conditions on the DTE under test.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 301 401 V1.2.6:2004 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Attachment requirements for Data Terminal Equipment (DTE) to connect to public networks that have physical and electrical network presentations based upon the ITU-T V-series of Recommendations". This standard covers: (Provisional) Attachment requirements for Data Terminal Equipment (DTE) to connect to physical and electrical network presentations that are based upon the ITU-T V Series of Recommendations. This TBR will combine and harmonize the requirements of TBR 1 and TBR 2. The TBR will contain all requirements deemed essential under Directive 91/263/EEC to approve terminals within this category regardless of the protocols transported accross such interfaces. In particular, the TBR will contain requirements for connection to V.10, V.11, V.12, V.28, V.35, and V.36 network presentations and will supercede TBR 1 and TBR 2. Reference documents: TBR 1, TBR 2, ITU-T Recommendations V.10, V.11, V.12, V.28, V.35 and V.36
(Provisional) Attachment requirements for Data Terminal Equipment (DTE) to connect to physical and electrical network presentations that are based upon the ITU-T V Series of Recommendations. This TBR will combine and harmonize the requirements of TBR 1 and TBR 2. The TBR will contain all requirements deemed essential under Directive 91/263/EEC to approve terminals within this category regardless of the protocols transported accross such interfaces. In particular, the TBR will contain requirements for connection to V.10, V.11, V.12, V.28, V.35, and V.36 network presentations and will supercede TBR 1 and TBR 2. Reference documents: TBR 1, TBR 2, ITU-T Recommendations V.10, V.11, V.12, V.28, V.35 and V.36
SIST EN 301 401 V1.2.6:2004 is classified under the following ICS (International Classification for Standards) categories: 33.050.01 - Telecommunication terminal equipment in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 301 401 V1.2.6:2004 is associated with the following European legislation: Standardization Mandates: T-237A. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 301 401 V1.2.6:2004 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.SULNOMXþHYDQMHAttachment requirements for Data Terminal Equipment (DTE) to connect to public networks that have physical and electrical network presentations based upon the ITU-T V-series of Recommendations33.050.01Telekomunikacijska terminalska oprema na splošnoTelecommunication terminal equipment in generalICS:Ta slovenski standard je istoveten z:EN 301 401 Version 1.2.6SIST EN 301 401 V1.2.6:2004en01-oktober-2004SIST EN 301 401 V1.2.6:2004SLOVENSKI
STANDARD
ETSIETSI EN 301 401 V1.2.6 (1999-10)2ReferenceDEN/DTA-000002 (cz000is0.PDF)KeywordsPSPDN, X.21ETSIPostal addressF-06921 Sophia Antipolis Cedex - FRANCEOffice address650 Route des Lucioles - Sophia AntipolisValbonne - FRANCETel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16Siret N° 348 623 562 00017 - NAF 742 CAssociation à but non lucratif enregistrée à laSous-Préfecture de Grasse (06) N° 7803/88Internetsecretariat@etsi.frIndividual copies of this ETSI deliverablecan be downloaded fromhttp://www.etsi.orgIf you find errors in the present document, send yourcomment to: editor@etsi.frImportant noticeThis ETSI deliverable may be made available in more than one electronic version or in print. In any case of existing orperceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).In case of dispute, the reference should be the printing on ETSI printers of the PDF version kept on a specific networkdrive within ETSI Secretariat.Copyright NotificationNo part may be reproduced except as authorized by written permission.The copyright and the foregoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1999.All rights reserved.SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)3ContentsIntellectual Property Rights.6Foreword.61Scope.72References.73Definitions and abbreviations.83.1Definitions.83.2Abbreviations.94Safety and EMC requirements.94.1Safety requirements.94.2EMC requirements.95Applicability of Standard.96Electrical, mechanical, and access control protocol requirements.106.1General characteristics.106.1.1Generator presentations.106.1.1.1Balanced generator.106.1.1.2Unbalanced generator.106.2Connector characteristics and contact number assignments.106.2.1 Attachment to a DCE interface presented on a 25-pole connector.106.2.1.1Connector.106.2.1.2Contact number assignments.106.2.2Attachment to a DCE interface presented on a 26-pole connector.116.2.2.1Connector.116.2.2.2Contact number assignments.116.2.3Attachment to a DCE interface presented on a 37-pole connector.116.2.3.1Connector.116.2.3.2Contact number assignments.116.2.4Attachment to a DCE interface presented on a 34-pole connector.116.2.4.1Connector.116.2.4.2Contact number assignments.126.2.5Attachment to a DCE interface presented on a 15-pole connector.126.2.5.1Connector.126.2.5.2Contact number assignments.126.2.6Attachment to a DCE interface presented on a 50-pole connector.126.2.6.1Connector.126.2.6.2Contact number assignments.126.3Electrical requirements.136.3.1Requirements for attachment to ITU-T Recommendation V.10 interchange circuits.136.3.1.1Generator open circuit output voltage.136.3.2Requirements for attachment to ITU-T Recommendation V.11 interchange circuits.136.3.2.1Generator open circuit output voltage.146.3.3Requirements for attachment to ITU-T Recommendation V.12 interchange circuits.146.3.3.1Generator open circuit output voltage.146.3.4Requirements for attachment to ITU-T Recommendation V.28 interchange circuits.156.3.4.1Generator open circuit output voltage.156.3.5Requirements for attachment to CCITT Recommendation V.35 interchange circuits.156.3.5.1Generator open circuit output voltage.156.3.6Requirements for attachment to ITU-T Recommendation V.36 interchange circuits.166.3.6.1Generator open circuit output voltage.167Test Specification.167.1Conditions of test.167.1.1Environment for tests.167.1.2Power supply limitations.16SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)47.1.3Test condition.177.1.4Test point.177.1.5Bit patterns.177.1.6Signal element timing.177.1.7Interchange circuits presentation.177.1.8Physical layer tests.177.1.8.1Verification of the electrical characteristics.177.1.8.2Identically implemented circuits.177.1.8.3Fixed state generators.187.2Test descriptions for connector characteristics and contact number assignments.187.2.125-pole connector.187.2.1.1Connector characteristics.187.2.1.2Contact number assignments.187.2.226-pole connector.187.2.2.1Connector characteristics.187.2.2.2Contact number assignments.187.2.2.2.1Connection to a DCE presenting ITU-T Recommendation V.10 or V.11 electricalcharacteristics.187.2.2.2.2Connection to a DCE presenting ITU-T Recommendation V.28 electrical characteristics.197.2.337-pole connector.197.2.3.1Connector characteristics.197.2.3.2Contact number assignments.197.2.434-pole connector.197.2.4.1Connector characteristics.197.2.4.2Contact number assignments.197.2.515-pole connector.197.2.5.1Connector characteristics.197.2.5.2Contact number assignments.207.2.650-pole connector.207.2.6.1Connector characteristics.207.2.6.2Contact number assignments.207.3Test descriptions for attachment to ITU-T Recommendation V.10 interchange circuits.207.3.1Generator characteristics.207.3.1.1Generator open circuit output voltage.207.4Test descriptions for attachment to ITU-T Recommendation V.11 interchange circuits.217.4.1Generator characteristics.217.4.1.1Generator open circuit output voltage.217.5Test descriptions for attachment to ITU-T Recommendation V.12 interchange circuits.227.5.1Generator characteristics.227.5.1.1Generator open circuit output voltage.227.6Test descriptions for attachment to ITU-T Recommendation V.28 interchange circuits.237.6.1Generator characteristics.237.6.1.1Generator open circuit output voltage.237.7Test descriptions for attachment to CCITT Recommendation V.35 interchange circuits.247.7.1Generator characteristics.247.7.1.1Generator open circuit output voltage.247.8Test case selection expression definition table.257.9Test case Index.26Annex A (normative):The Requirements Table (RT).28A.1Introduction to the RT.28A.2Format of the tables.28A.3Notations used in the RT.29A.3.1Status notations.29A.3.2Support answer notations.29A.4The Harmonized Standard Requirement Tables.29A.4.1Means of connection to the DCE.29A.4.2Connection to a DCE presenting an ISO 2110 (25-pole) connector.30SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)5A.4.3Connection to a DCE presenting an ISO/IEC 11569 (26-pole) connector.31A.4.4Connection to a DCE presenting an ISO 4902 (37-pole) connector.34A.4.5Connection to a DCE presenting an ISO 2593 (34-pole) connector.36A.4.6Connection to a DCE presenting an ISO 4903 (15-pole) connector.38A.4.7Connection to a DCE presenting an TIA/EIA-613 (50-pole) connector.40Annex B (normative):Physical layer implementation extra information for testing (PIXIT).42Bibliography.43History.44SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)6Intellectual Property RightsIPRs essential or potentially essential to the present document may have been declared to ETSI. The informationpertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be foundin SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respectof ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server(http://www.etsi.org/ipr).Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guaranteecan be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server)which are, or may be, or may become, essential to the present document.ForewordThis Candidate Harmonized European Standard (Telecommunications series) has been produced by ETSI ProjectDigital Terminals and Access (DTA).The present document has been produced by ETSI in response to a mandate from the European Commission issuedunder Council Directive 98/34/EC [4] (as amended) laying down a procedure for the provision of information in thefield of technical standards and regulations.The present document is intended to become a Harmonized Standard, the reference of which may be published in theOfficial Journal of the European Communities referencing the Council Directive 98/13/EC [3] on the approximation ofthe laws of the Member States concerning telecommunications terminal equipment, including the mutual recognition oftheir conformity ("the TTE Directive").Technical specifications relevant to the TTE Directive are given in annex A.National transposition datesDate of adoption of this EN:22 October 1999Date of latest announcement of this EN (doa):31 January 2000Date of latest publication of new National Standardor endorsement of this EN (dop/e):31 July 2000Date of withdrawal of any conflicting National Standard (dow):31 July 2000SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)71ScopeThe present document specifies the technical characteristics to be provided by terminal equipment to be connected topublic networks presented at an ITU-T Recommendations V.10 [10], V.11 [11] (including X.26 [21] and X.27 [22]),V.12 [12], V.24 [13]/V.28 [14], V.35 [15] or V.36 [16] interface regardless of data rate. The objective of the presentdocument is to ensure that no disturbance occurs to the public network.The present document contains the minimum set of requirements derived from the above set of ITU-TRecommendations and is applicable for connection to X.21 [18] leased line and circuit switched, X.21 bis [19] leasedlines, X.25, Frame Relay and SMDS plus any other public network service that may be presented on the same electricalinterfaces.NOTE:Not all of the above services are available in all countries.A test is given for each requirement in the present document, including measurement methods. Requirements apply atthe public network interface of the terminal equipment, which may be stimulated to perform the tests by additionalequipment if necessary.Terminal equipment may be subject to additional or alternative requirements depending on its functionality, in particularif it supports a service that is considered to be a justified case for regulation of terminal interworking via thetelecommunications network.2ReferencesThe following documents contain provisions which, through reference in this text, constitute provisions of the presentdocument.· References are either specific (identified by date of publication, edition number, version number, etc.) ornon-specific.· For a specific reference, subsequent revisions do not apply.· For a non-specific reference, the latest version applies.· A non-specific reference to an ETS shall also be taken to refer to later versions published as an EN with the samenumber.[1]Council Directive 73/23/EEC of February 1973 on the harmonization of the laws of the MemberStates relating to electrical equipment designed for use within certain voltage limits (Low VoltageDirective.[2]Council Directive 89/336/EECof 3 May 1989 on the approximation of the laws of Member Statesrelating to electromagnetic compatibility.[3]Council Directive 98/13/EEC of 12 February 1998 relating to telecommunications terminalequipment and satellite earth station equipment, including the mutual recognition of theirconformity.[4]Council Directive 98/34/EC of 22 June 1998 laying down a procedure for the provision ofinformation in the field of technical standards and regulations.[5]ISO 2110 (1980): "Information technology - Data communication - 25-pole DTE/DCE interfaceconnector and contact number assignments".[6]ISO 2593 (1984): "Information technology - Telecommunications and information exchangebetween systems - 34-pole DTE/DCE interface connector and contact number assignments".[7]ISO 4902 (1980): "Information technology - Data communication - 37-pole DTE/DCE interfaceconnector and contact number assignments".SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)8[8]ISO 4903 (1989): "Information technology - Data communication - 15-pole DTE/DCE interfaceconnector and contact number assignments".[9]ISO/IEC 11569 (1992): "Information technology - Telecommunications and information exchangebetween systems - 26-pole interface connector mateability dimensions and contact numberassignments".[10]ITU-T Recommendation V.10 (1993): "Electrical characteristics for unbalanced double-currentinterchange circuits operating at data signalling rates nominally up to 100 kbit/s".[11]ITU-T Recommendation V.11 (1996): " Electrical characteristics for balanced double-currentinterchange circuits operating at data signalling rates up to 10 Mbit/s".[12]ITU-T Recommendation V.12 (1995): "Electrical characteristics for balanced double-currentinterchange circuits for interfaces with data signalling rates up to 52 Mbit/s."[13]ITU-T Recommendation V.24: "List of definitions for interchange circuits between data terminalequipment (DTE) and data circuit-terminating equipment (DCE)".[14]ITU-T Recommendation V.28 (1993): "Electrical characteristics for unbalanced double-currentinterchange circuits".[15]CCITT Recommendation V.35 (1984): "Data transmission at 48 kilobits per second using60-108 kHz group band circuits - Appendix II Electrical characteristics for balanceddouble-current interchange circuits".[16]ITU-T Recommendation V.36: "Modems for synchronous data transmission using 60-108 kHzgroup band circuits".[17]ITU-T Recommendation X.2 (1996): " International data transmission services and optional userfacilities in public data networks and ISDNs".[18]ITU-T Recommendation X.21 (1992): "Interface between Data Terminal Equipment and DataCircuit-terminating Equipment for synchronous operation on public data networks".[19]ITU-T Recommendation X.21 bis: "Use on public data networks of Data Terminal Equipment(DTE) which is designed for interfacing to synchronous V-Series modems".[20]ITU-T Recommendation X.25 (1996): "Interface between Data Terminal Equipment (DTE) andData Circuit-terminating Equipment (DCE) for terminals operating in the packet mode andconnected to public data networks by dedicated circuit".[21]ITU-T Recommendation X.26: "see ITU-T Recommendation V.10".[22]ITU-T Recommendation X.27: "See ITU-T Recommendation V.11".[23]TIA/EIA-613: "High Speed Serial Interface for Data Terminal Equipment and Data Circuit-Terminating Equipment".3Definitions and abbreviations3.1DefinitionsFor the purposes of the present document, the following terms and definitions apply:ITU-T Recommendation X.25 [20] network: PSPDN network which offers a ITU-T Recommendation X.25 [20]DTE/DCE interface providing the (E) facilities for user classes of service 8-11 as defined inITU-T Recommendation X.2, [17].All other definitions are as given in the ITU-T series of Recommendations.SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)93.2AbbreviationsFor the purposes of the present document, the following abbreviations apply:acalternating currentdcdirect currentDCEData Circuit terminating EquipmentDTEData Terminal EquipmentEMCElectroMagnetic CompatibilityRTRequirements TableIUTImplementation Under TestPIXITProtocol Implementation eXtra Information for TestingPSPDNPacket Switched Public Data NetworkTBRTechnical Basis for RegulationTETerminal EquipmentVoopen-circuit generator voltage4Safety and EMC requirements4.1Safety requirementsThere are no safety requirements contained within the present document.NOTE:Safety requirements are imposed under the Low Voltage Directive (73/23/EEC) [1] and articles 5 (a) and5 (b) of Directive 98/13/EEC [3].4.2EMC requirementsThere are no EMC requirements contained within the present document.NOTE:General EMC requirements are imposed under EMC Directive (89/336/EEC) [2] and article 5 (c) ofDirective 98/13/EEC [3].5Applicability of StandardThe requirements in the present document are applicable to DTE intended to be connected to DCE interfaces on publicnetworks providing one or more of the following services:-circuit switched data transmission service;-packet switched data transmission service;-leased circuit data transmission service;-frame relay data transmission service, orany other service presented via an ITU-T V series interface.SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)106Electrical, mechanical, and access control protocolrequirementsThe requirements of this clause apply at the means of connection to the DCE.6.1General characteristics6.1.1Generator presentations6.1.1.1Balanced generatorIn the case of balanced terminal equipment generators, points A and B are defined as the two physical connections, onthe means provided for connection to the DCE, to which the output of a terminal generator is connected, and point C isthe physical connection on the means of connection to the DCE to which the terminal equipment signal ground mayoptionally be connected (see figure 2).6.1.1.2Unbalanced generatorIn the case of unbalanced terminal equipment generators, point A is defined as the physical connection on the meansprovided for connection to the DCE, to which the output of a terminal generator is connected, and point C is the physicalconnection on the means of connection to the DCE to which the signal ground associated with that generator isconnected.6.2Connector characteristics and contact number assignmentsThe means of connection to the DCE should conform to either subclauses 6.2.1, 6.2.2, 6.2.3, 6.2.4, 6.2.5 or 6.2.6.A manufacturer employing an alternative means of connection shall declare details of this arrangement in a formatsimilar to the Requirements Table (RT) contained in annex A. This declaration shall include details of circuit allocationand, information about the ITU-T V series Recommendations against which compliance is to be assessed. Complianceof such alternative connection characteristics shall be checked in a way similar to the tests described in subclause 7.2, ifappropriate.6.2.1Attachment to a DCE interface presented on a 25-pole connector6.2.1.1ConnectorThe means of connection to the DCE shall be a male connector conforming to ISO 2110 [5].NOTE:This requirement is based upon subclause 1.2 of ITU-T Recommendation X.21 bis [19].Compliance shall be checked by the test given in subclause 7.2.1.1.Justification: Directive 98/13/EEC [3], article 5 (d).6.2.1.2Contact number assignmentsOn the means of connection to the DCE, the presentation of the interchange circuits shall be in accordance withannex A, tables A.2 and A.3.NOTE:This requirement is based upon subclause 1.2 of ITU-T Recommendation X.21 bis [19] and ISO 2110 [5].Compliance shall be checked as described in subclause 7.2.1.2.Justification: Directive 98/13/EEC [3], article 5 (d).SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)116.2.2Attachment to a DCE interface presented on a 26-pole connector6.2.2.1ConnectorThe means of connection to the DCE shall be a male connector conforming to ISO/IEC 11569 [9].NOTE:This requirement is based upon ISO/IEC 11569 [9].Compliance shall be checked by the test given in subclause 7.2.2.1 as appropriate.Justification: Directive 98/13/EEC [3], article 5 (d).6.2.2.2Contact number assignmentsOn the means of connection to the DCE, the presentation of the interchange circuits shall be in accordance withannex A, tables A.6 and A.7 or tables A.10 and A.11.NOTE:This requirement is based upon ISO/IEC 11569 [9].Compliance shall be checked as described in subclause 7.2.2.2 as appropriate.Justification: Directive 98/13/EEC [3], article 5 (d).6.2.3Attachment to a DCE interface presented on a 37-pole connector6.2.3.1ConnectorThe means of connection to the DCE shall be a male connector conforming to ISO 4902 [7].NOTE:This requirement is based upon subclause 1.2 of ITU-T Recommendation X.21 bis [19].Compliance shall be checked by the test given in subclause 7.2.3.1 as appropriate.Justification: Directive 98/13/EEC [3], article 5 (d).6.2.3.2Contact number assignmentsOn the means of connection to the DCE, the presentation of the interchange circuits shall be in accordance withannex A, tables A.13 and A.14.NOTE:This requirement is based upon subclause 1.2 of ITU-T Recommendation X.21 bis [19] and ISO 4902 [7].Compliance shall be checked as described in subclause 7.2.3.2 as appropriate.Justification: Directive 98/13/EEC [3], article 5 (d).6.2.4Attachment to a DCE interface presented on a 34-pole connector6.2.4.1ConnectorThe means of connection to the DCE shall be a male connector conforming to ISO 2593 [6].NOTE:This requirement is based upon subclause 1.2 of ITU-T Recommendation X.21 bis [19].Compliance shall be checked by the test given in subclause 7.2.4.1 as appropriate.Justification: Directive 98/13/EEC [3], article 5 (d).SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)126.2.4.2Contact number assignmentsOn the means of connection to the DCE, the presentation of the interchange circuits shall be in accordance withannex A, tables A.17 and A.18.NOTE:This requirement is based upon subclause 1.2 of ITU-T Recommendation X.21 bis [19] and ISO 2593 [6].Compliance shall be checked as described in subclause 7.2.4.2 as appropriate.Justification: Directive 98/13/EEC [3], article 5 (d).6.2.5Attachment to a DCE interface presented on a 15-pole connector6.2.5.1ConnectorThe means of connection to the DCE shall be a male connector conforming to ISO 4903 [8].NOTE:This requirement is based upon subclause 2.2 of ITU-T Recommendation X.21 [18].Compliance shall be checked by the test given in subclause 7.2.5.1 as appropriate.Justification: Directive 98/13/EEC [3], article 5 (d).6.2.5.2Contact number assignmentsOn the means of connection to the DCE, the presentation of the interchange circuits shall be in accordance withannex A, tables A.23 and A.24.NOTE:This requirement is based upon subclause 2.2 of ITU-T Recommendation X.21 [18] and ISO 4903 [8].Compliance shall be checked as described in subclause 7.2.5.2 as appropriate.Justification: Directive 98/13/EEC [3], article 5 (d).6.2.6Attachment to a DCE interface presented on a 50-pole connector6.2.6.1ConnectorThe means of connection to the DCE shall be a male connector conforming to TIA/EIA-613 [23].NOTE:This requirement is based upon subclause 2.2 of ITU-T Recommendation X.21 [18].Compliance shall be checked by the test given in subclause 7.2.6.1 as appropriate.Justification: Directive 98/13/EEC [3], article 5 (d).6.2.6.2Contact number assignmentsOn the means of connection to the DCE, the presentation of the interchange circuits shall be in accordance withannex A, tables A.27 and A.28.NOTE:This requirement is based upon subclause 2.2 of ITU-T Recommendation X.21 [18] andTIA/EIA-613 [23].Compliance shall be checked as described in subclause 7.2.6.2 as appropriate.Justification: Directive 98/13/EEC [3], article 5 (d).SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)136.3Electrical requirementsFor a particular terminal implementation, the generator requirements of the present document apply only to the extentthat they are relevant to a particular generator. For instance, where, in a particular terminal implementation, a particulargenerator circuit, in normal operation, is fixed in one of the binary states, only those requirements relevant to that fixedbinary state shall apply.NOTE:It is possible for particular interchange circuits of a TE to be intended for connection to more than onetype of interchange circuit which could be presented by a DCE (e.g. to both ITU-T RecommendationsV.10 [10] and V.28 [14]).Where an interchange circuit, presented by the TE, to which a particular section of subclause 6.3 applies,is intended to be connected additionally to interchange circuits presented by a DCE which conform toother sections of subclause 6.3, the requirements of that section of subclause 6.3 relevant to thosecharacteristics also apply.Additionally, for a particular DTE-DCE interface, not all signals may be employing the same interchangecircuit characteristics. It is the interchange characteristic of the individual signals presented by thenetwork that dictate which sections of subclause 6.3 apply.6.3.1Requirements for attachment to ITU-T Recommendation V.10interchange circuitsThe requirements of this subclause apply to interchange circuits, presented by the TE on the means for connection to theDCE, that are intended for connection to circuits presented by the DCE that conform toITU-T Recommendation V.10 [10].6.3.1.1Generator open circuit output voltageWhen a 3 900 W non-reactive impedance is connected between points A and C, for each binary state, the magnitude ofthe voltage between points A and C shall be less than or equal to 12,0 V. GACRVoIVoI <= 12,0VR = 3 900 WNOTE:This requirement is based upon ITU-T Recommendation V.10 [10] subclauses 5.2.1 and 6.3.
Figure 1Compliance shall be verified in accordance with the test specified in subclause 7.3.1.1.Justification: Directive 98/13/EEC [3], article 5 (d).6.3.2Requirements for attachment to ITU-T Recommendation V.11interchange circuitsThe requirements of this subclause apply to interchange circuits, presented by the TE on the means for connection to theDCE, intended for connection to circuits presented by the DCE that conform to ITU-T Recommendation V.11 [11].SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)146.3.2.1Generator open circuit output voltageWhen a 3 900 W non-reactive impedance is connected between points A and B, for each binary state (see figure 2):a)the magnitude of the voltage between points A and B shall be less than or equal to 12,0 V;b)the magnitude of the voltage between either points A or B and point C shall be less than or equal to 12,0 V. G£££12,0V12,0V12,0VR = 3 900WNOTE:This requirement is based upon ITU-T Recommendation V.11 [11] subclauses 5.2.1 and 6.3.
Figure 2Compliance shall be verified in accordance with the test specified in subclause 7.4.1.1.Justification: Directive 98/13/EEC [3], article 5 (d).6.3.3Requirements for attachment to ITU-T Recommendation V.12interchange circuitsThe requirements of this subclause apply to interchange circuits, presented by the TE on the means for connection to theDCE, that are intended for connection to circuits presented by the DCE that conform toITU-T Recommendation V.12 [12].6.3.3.1Generator open circuit output voltageWhen connected as shown in figure 3, the magnitude of the voltage between points A and C shall be less than or equalto 1,5 V. GACVo|Vo| <=1,5VNOTE:This requirement is based upon ITU-T Recommendation V.12 [12] subclause 4.1.1.
Figure 3Compliance shall be verified in accordance with the test specified in subclause 7.5.1.1.Justification: Directive 98/13/EEC [3], article 5 (d).SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)156.3.4Requirements for attachment to ITU-T Recommendation V.28interchange circuitsThe requirements of this subclause apply to interchange circuits, presented by the TE on the means for connection to theDCE, that are intended for connection to circuits presented by the DCE that conform toITU-T Recommendation V.28 [14].6.3.4.1Generator open circuit output voltageWhen connected as shown in figure 4, the magnitude of the voltage between points A and C shall be less than or equalto 25,0 V. GACVo|Vo| <=25,0VNOTE:This requirement is based upon ITU-T Recommendation V.28 [14] subclause 4.
Figure 4Compliance shall be verified in accordance with the test specified in subclause 7.6.1.1.Justification: Directive 98/13/EEC [3], article 5 (d).6.3.5Requirements for attachment to CCITT Recommendation V.35interchange circuitsThe requirements of this subclause apply to interchange circuits, presented by the TE on the means for connection to theDCE, that are intended for connection to circuits presented by the DCE that conform toCCITT Recommendation V.35 [15].6.3.5.1Generator open circuit output voltageWhen terminated with a 3 900 W non-reactive impedance connected between points A and B (see figure 5), for eachbinary state:a)the magnitude of the voltage between points A and B shall be less than or equal to 1,2 V;b)the magnitude of the voltage between either points A or B and point C shall be less than or equal to 1,2 V.SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)16 G£££1,2V1,2V1,2VR = 3 900WNOTE:This requirement is based upon CCITT Recommendation V.35 [15] annex 2 subclause 5.2.3.
Figure 5Compliance shall be verified in accordance with the test specified in subclause 7.7.1.1.Justification: Directive 98/13/EEC [3], article 5 (d).6.3.6Requirements for attachment to ITU-T Recommendation V.36interchange circuitsThe requirements of this subclause apply to interchange circuits, presented by the TE on the means for connection to theDCE, that are intended for connection to circuits presented by the DCE that conform to ITU-T Recommendation V.36[16].6.3.6.1Generator open circuit output voltageInterchange circuits that conform to ITU-T Recommendation V.36 [16] have electrical characteristics conforming toeither ITU-T Recommendation V.10 [10] and/or ITU-T Recommendation V.11 [11]. The manufacturer shall declarewhich interchange circuits exhibit which characteristics, and these shall be verified in accordance with the requirementsspecified in subclauses 6.3.1.1 and 6.3.2.1.Justification: Directive 98/13/EEC [3], article 5 (d).7Test Specification7.1Conditions of test7.1.1Environment for testsAll tests shall be performed at:a)an ambient temperature in the range 15°C to 35°C;b)a relative humidity in the range of 5 % to 75 %.The tests shall not be performed outside the operating limits for the terminal equipment as stated by the client.7.1.2Power supply limitationsFor apparatus that is directly powered from the mains supply all tests shall be carried out within ±5 % of the normaloperating voltage.If apparatus is powered by other means and those means are not supplied as part of the apparatus, e.g. batteries,stabilized ac supplies, dc, etc., all tests shall be carried out within the power supply limit declared by the supplier. If thepower supply is ac., the tests shall be conducted within ±4 % of the stated frequency as declared by the supplier.SIST EN 301 401 V1.2.6:2004
ETSIETSI EN 301 401 V1.2.6 (1999-10)177.1.3Test conditionAll requirements apply and tests are carried out with the terminal in the "power on" condition unless otherwise stated.7.1.4Test pointTests shall be carried out at the point of connection to the DCE on the means provided by the terminal equipment forconnecting to the DCE.In order to carry out these tests the client shall provide a means of connecting the terminal equipment to a DCE (e.g. acable) which is representative of the means of connecting to a DCE intended to be used by, or supplied with theapparatus.The definition of points A, B, and C in respect of generators is contained in subclause 6.1.1.7.1.5Bit patternsIt may be necessary in certain instances, for the tester to send specified bit patterns to the terminal equipment to ensurethat a particular state is maintained. The applicant shall inform the test laboratory of such cases and specify the nature ofthe bit patterns to be sent.7.1.6Signal element timingFor some terminal equipment it may be necessary to provide Signal Element Timing in order to carry out the testsspecified in the present document. Where this is necessary it shall be at a data signalling rate appropriate for theequipment under test. The applicant shall inform the test laboratory of such cases and specify the nature of the SignalElement Timing to be supplied.7.1.7Interchange circuits presentationThe tester shall assume that the interchange circuits are presented on the means for connection to the DCE on the polesof the connector as declared in the RT in annex A.7.1.8Physical layer tests7.1.8.1Verification of the electrical characteristicsVerification of the electrical characteristics shall be based upon either:a)the tests described in subclauses 7.2, 7.3, 7.4, 7.5, 7.6, or 7.7 as appropriate; orb)by agreement between the client and the test laboratory, the submission by the client to the test laboratory of adeclaration of conformance, including circuit diagrams, component specifications, and other relevantinformation. The test laboratory shall, on the basis of the evidence accompanying the declaration, be responsiblefor satisfying itself that the declaration gives assurance of conformity not less than that achieved by method a)above.7.1.8.2Identica
...