Abstract

The purpose of this sub-part of this standard is to define the classes of environmental conditions and their severities to which equipment may be exposed during storage. Only severe conditions, which may be harmful to the equipment, are included. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. NOTE 1: Temporary storage during transport is included in Sub-part 1-2: Transportation. NOTE 2: If the equipment is packaged, the environmental conditions apply to the packaging protecting the equipment.

Status
Published
Publication Date
31-Jan-2006
Withdrawal Date
30-Sep-2003
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Feb-2006
Due Date
01-Feb-2006
Completion Date
01-Feb-2006

Buy Documents

Standard

SIST ETS 300 019-1-1 E1:2006

English language (17 pages)
Preview
Preview
e-Library read for
×1 day

SIST ETS 300 019-1-1 E1:2006 is the Slovene identical version of ETS 300 019-1-1 Edition 1 from the European Telecommunications Standards Institute (ETSI). It belongs to the Equipment Engineering (EE) series and specifies environmental condition classes for telecommunications equipment during storage. In practice, it tells designers, packagers, test labs, and buyers what storage environment the equipment should be able to withstand.

What does SIST ETS 300 019-1-1 E1:2006 specify?

SIST ETS 300 019-1-1 E1:2006 classifies storage environments and the severities that equipment may meet while it is stored. The scope focuses on severe conditions that can harm equipment, with severities chosen because they have a low probability of being exceeded, generally less than 1%.

The document is organized into five clauses: scope, normative references, definitions, environmental classes, and environmental conditions. Clause 4 sets out the storage classes, and Clause 5 gives the environmental parameters for those classes.

The standard also notes that temporary storage during transport belongs to Sub-part 1-2, and that packaged equipment is assessed through the packaging that protects it.

What are the key requirements of SIST ETS 300 019-1-1 E1:2006?

SIST ETS 300 019-1-1 E1:2006 gives four storage classes and ties each one to environmental severities. The practical point is that users must match the equipment and its packaging to the storage location, not just to the product itself.

Main class definitions in Clause 4

  • Class 1.1 - weatherprotected, partly temperature-controlled storage. This covers ordinary storage rooms with limited weather exposure and low mechanical stress.
  • Class 1.2 - weatherprotected, not temperature-controlled storage. This allows more variation, including openings to the open air, condensation, icing, and limited wind-driven precipitation.
  • Class 1.3 - non-weatherprotected storage. This is for storage directly exposed to open-air climate, precipitation, water jets, dust, and significant vibration and shock.
  • Class 1.3E - an extended version of 1.3 with severities taken from Clause 5.1. This gives a defined option when open-air storage needs a stated climatic basis.

Environmental parameters in Clause 5

  • Climatic conditions in Table 1 cover temperature, humidity, rain, solar radiation, air movement, condensation, precipitation, water from other sources, icing, and static load from climate. In practice, this is the core set used to judge whether stored equipment survives the site climate.
  • Biological conditions in Table 2 distinguish negligible exposure in Class 1.1 from mould, fungus, rodents, and other harmful animals in Classes 1.2, 1.3, and 1.3E.
  • Chemically active substances in Table 3 set long-term and maximum exposure levels for gases such as sulphur dioxide, chlorine, ammonia, ozone, and nitrogen oxides.
  • Mechanically active substances in Table 4 cover sand and dust, which matter for contamination and wear.
  • Mechanical conditions in Table 5 cover stationary vibration, non-stationary vibration including shock, and static load. Figure 4 gives the model shock response spectra used with the vibration and shock description.

What terms does SIST ETS 300 019-1-1 E1:2006 define?

SIST ETS 300 019-1-1 E1:2006 defines storage as a period when equipment is placed at a site for long periods and is not intended for use.

A weatherprotected location protects equipment from weather influences, while a totally weatherprotected location excludes direct weather influences completely.

A partly weatherprotected location reduces weather exposure but does not remove it entirely. A non-weatherprotected location gives no protection from direct weather influences.

Who uses SIST ETS 300 019-1-1 E1:2006?

SIST ETS 300 019-1-1 E1:2006 is used by telecom equipment manufacturers, environmental test laboratories, packaging engineers, and quality managers. It is also useful for buyers and specifiers who need to state storage conditions in procurement or acceptance requirements.

Its main use is to decide whether a product, package, or storage site is suitable for storage, and what climate, dust, moisture, vibration, and chemical exposure must be considered.

What changed in SIST ETS 300 019-1-1 E1:2006 from the previous edition?

SIST ETS 300 019-1-1 E1:2006 is identified as the Slovene standard identical to ETS 300 019-1-1 Edition 1. The history shown on the document page lists the first edition from February 1992.

Which standards are used with SIST ETS 300 019-1-1 E1:2006?

SIST ETS 300 019-1-1 E1:2006 cites ETR 035 for environmental engineering guidance and terminology. It uses IEC Publication 721-3-1 as the basis for the storage classes, IEC Publication 68-2-27 for shock, and IEC Publication 721-2-4 for solar radiation and temperature effects.

The foreword also places this part within ETS 300 019-1, which covers classification of environmental conditions, and ETS 300 019-2, which covers the corresponding environmental tests.

What does the SIST ETS 300 019-1-1 E1:2006 document contain?

SIST ETS 300 019-1-1 E1:2006 contains climatograms for the storage classes, together with tables for climatic, biological, chemical, dust, and mechanical conditions. It also includes a model shock response spectrum figure that supports the vibration and shock description.

For practical work, those tables and figures are used when specifying storage limits, checking packaging, setting test conditions, or writing procurement and quality documents.

Buy Documents

Standard

SIST ETS 300 019-1-1 E1:2006

English language (17 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

IMP NDT d.o.o.

Non-destructive testing services. Radiography, ultrasonic, magnetic particle, penetrant, visual inspection.

SA Slovenia Verified

Inštitut za kovinske materiale in tehnologije

Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

SIST ETS 300 019-1-1 E1:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-1: Classification of environmental conditions; Storage". This standard covers: The purpose of this sub-part of this standard is to define the classes of environmental conditions and their severities to which equipment may be exposed during storage. Only severe conditions, which may be harmful to the equipment, are included. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. NOTE 1: Temporary storage during transport is included in Sub-part 1-2: Transportation. NOTE 2: If the equipment is packaged, the environmental conditions apply to the packaging protecting the equipment.

The purpose of this sub-part of this standard is to define the classes of environmental conditions and their severities to which equipment may be exposed during storage. Only severe conditions, which may be harmful to the equipment, are included. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. NOTE 1: Temporary storage during transport is included in Sub-part 1-2: Transportation. NOTE 2: If the equipment is packaged, the environmental conditions apply to the packaging protecting the equipment.

SIST ETS 300 019-1-1 E1:2006 is classified under the following ICS (International Classification for Standards) categories: 19.040 - Environmental testing; 33.050.01 - Telecommunication terminal equipment in general. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST ETS 300 019-1-1 E1:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-februar-2006
,QåHQLULQJRSUHPH (( ±2NROMVNLSRJRMLLQSUHVNXVLYSOLYRYRNROMDQD
WHOHNRPXQLNDFLMVNRRSUHPR±GHO.ODVLILNDFLMDRNROMVNLKSRJRMHY±
6NODGLãþHQMH
Equipment Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 1-1: Classification of environmental conditions;
Storage
Ta slovenski standard je istoveten z: ETS 300 019-1-1 Edition 1
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN ETS 300 019-1-1
TELECOMMUNICATION February 1992
STANDARD
Source: ETSI TC-EE Reference: DE/EE-1019-1-1
ICS: 33.080
Environment, test, equipment
Key words:
Equipment Engineering (EE);
Environmental conditions and environmental tests for
telecommunications equipment
Part 1-1: Classification of environmental conditions
Storage
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
F-06921 Sophia Antipolis CEDEX - FRANCE
Postal address:
650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
Office address:
c=fr, a=atlas, p=etsi, s=secretariat - secretariat@etsi.fr
X.400: Internet:
Tel.: +33 92 94 42 00 - Fax: +33 93 65 47 16
Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the
foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1992. All rights reserved.
New presentation - see History box

Page 2
ETS 300 019-1-1: February 1992
Whilst every care has been taken in the preparation and publication of this document, errors in content,
typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to
"ETSI Editing and Committee Support Dept." at the address shown on the title page.

Page 3
ETS 300 019-1-1: February 1992
Contents
Foreword.5
1 Scope .7
2 Normative references .7
3 Definitions. 7
4 Environmental classes .7
4.1 Class 1.1: Weatherprotected, partly temperature-controlled storage locations.7
4.2 Class 1.2: Weatherprotected, not temperature-controlled storage locations.9
4.3 Class 1.3: Non-weatherprotected storage locations; class 1.3E: non-weatherprotected
storage locations - extended. 11
5 Environmental conditions. 13
5.1 Climatic conditions. 13
5.2 Biological conditions . 14
5.3 Chemically active substances. 14
5.4 Mechanically active substances. 15
5.5 Mechanical conditions. 15
History. 17

Page 4
ETS 300 019-1-1: February 1992
Blank page
Page 5
ETS 300 019-1-1: February 1992
Foreword
This multi-part European Telecommunication Standard (ETS) has been produced by the Equipment
Engineering (EE) Technical Committee of the European Telecommunications Standards Institute (ETSI).
This standard is concerned with the environmental conditions and environmental tests for
telecommunications equipment and comprises two main parts, each with subdivisions:
- ETS 300 019-1: "Classification of environmental conditions".
This part of the standard, Part 1, specifies different standardised environmental classes covering
climatic and biological conditions, chemically and mechanically active substances and mechanical
conditions during storage, transportation and in use.
- ETS 300 019-2: "Specification of environmental tests".
This part of the standard specifies the test requirements for the different environmental classes.
Each part of the standard is divided into sub-parts. Sub-part 1-0 will form a general overview of Part 1.
This sub-part, Sub-part 1-1, deals with storage.
This part of the standard (Part 1) was submitted to Public Enquiry as prETS 300 019 Part B. The original
Part A is to be published as ETSI Technical Report ETR 035 entitled: "Equipment Engineering (EE);
Environmental engineering Guidance and terminology".

Page 6
ETS 300 019-1-1: February 1992
Blank page
Page 7
ETS 300 019-1-1: February 1992
1 Scope
The purpose of this sub-part of this standard is to define the classes of environmental conditions and their
severities to which equipment may be exposed during storage. Only severe conditions, which may be
harmful to the equipment, are included. The severities specified are those which will have a low probability
of being exceeded; generally less than 1 %.
NOTE 1: Temporary storage during transport is included in Sub-part 1-2: Transportation.
NOTE 2: If the equipment is packaged, the environmental conditions apply to the packaging
protecting the equipment.
2 Normative references
This ETS incorporates, by dated or undated reference, provisions from other publications. These normative
references are cited at the appropriate places in the text and the publications are listed hereafter. For
dated references, subsequent amendments to, or revisions of any of these publications apply to this ETS
only when incorporated into it by amendment or revision. For undated references the latest edition of the
publication referred to applies.
[1] ETR 035: "Equipment Engineering (EE); Environmental engineering Guidance
and terminology".
[2] IEC Publication 721-3-1: "Storage".
[3] IEC Publication 68-2-27: "Test Ea: Shock".
[4] IEC Publication 721-2-4: "Solar radiation and temperature".
3 Definitions
In this sub-part of this standard, the following definitions apply:
Storage: The equipment is placed at a certain site for long periods but is not intended for use during these
periods.
Weatherprotected location: A location at which the equipment is protected from weather influences.
- Totally weatherprotected location: Direct weather influences are totally excluded.
- Partly weatherprotected location: Direct weather influences are not completely excluded.
Non-weatherprotected location: A location at which equipment is not protected from direct weather
influences.
4 Environmental classes
The classes shown in parentheses, e.g. (1C1), may be selected for special applications.
4.1 Class 1.1: Weatherprotected, partly temperature-controlled storage locations
This class is a combination of classes 1K3/1Z2/1B1/1C2(1C1)/1S2/1M2 in IEC Publication 721-3-1 [2].
This class applies to weatherprotected partly temperature controlled storage. Humidity is usually not
controlled. The climatogram is shown in figure 1.
Heating may be used to raise low temperatures especially where there is a significant difference between
the conditions of this class and the open-air climate. Building construction is designed to avoid extremely
high temperatures.
Page 8
ETS 300 019-1-1: February 1992
This class applies to storage locations:
- where equipment may be exposed to solar radiation and heat radiation. It may also be exposed to
movements of the surrounding air due to draughts in buildings, e.g. through open windows. It is not
subjected to precipitation and water from sources other than rain;
- without particular risks by biological attacks. This includes protective measures, e.g. special
package design, or storing at locations of such construction that mould growth, attacks by animals
etc. are not probable;
- with normal levels of contaminants experienced in urban areas with industrial activities scattered
over the whole area, and/or with heavy traffic;
- without special precautions to minimise the presence of dust or sand, but not situated in proximity to
dust or sand sources;
- with vibration of low significance and insignificant shock.
The conditions of this class may occur in ordinary storage rooms for frost-resistant products.

Page 9
ETS 300 019-1-1: February 1992
Figure 1: Climatogram for class 1.1 - Weatherprotected, partly temperature-controlled storage
locations
4.2 Class 1.2: Weatherprotected, not temperature-controlled storage locations
This class is a combination of classes 1K4/1Z2/1Z3/1Z5/1B2/1C2(1C1)/1S3/1M2 in IEC Publication 721-
3-1 [2].
This class applies to weatherprotected storage having neither temperature nor humidity control. The
location may have openings directly to the open air, i.e. it may be only partly weatherprotected. The
climatogram is shown in figure 2.
This class applies to storage locations:
- where equipment may be exposed to solar radiation and temporarily to heat radiation. They may
also be exposed to movements of the surrounding air due to draughts, e.g. through doors, windows
or other openings. They may be subjected to condensed water, dripping water and to icing. They
may also be subjected to limited wind-driven precipitation including snow;
- where mould growth, or attacks by animals, except termites, may occur;
- with normal levels of contaminants experienced in urban areas with industrial activities scattered
over the whole area, and/or with heavy traffic;

Page 10
ETS 300 019-1-1: February 1992
- in areas with sources of sand or dust, including urban areas;
- with vibration of low significance and insignificant shock.
The conditions of this class may occur in:
- unattended buildings;
- some entrances of buildings;
- some garages and shacks.
Figure 2: Climatogram for class 1.2: Weatherprotected, not temperature-controlled storage
locations
Page 11
ETS 300 019-1-1: February 1992
4.3 Class 1.3: Non-weatherprotected storage locations; class 1.3E: non-weatherprotected
storage locations - extended
1)
Class 1.3 is a combination of classes 1K8/1Z1/1Z4/1B2/1C2/1S3/1M3(1M4) in IEC Publication 721-3-1
1)
[2]. Class 1.3E is a combination of classes 1Z1/1Z4/1B2/1C2/1S3/1M3(1M4) in IEC Publication 721-3-1
[2] and the severities given in subclause 5.1.
This class applies to storage which is not protected from direct weather influences. The climatogram is
shown in figure 3.
This class applies to storage locations:
- which are directly exposed to an open-air climate including solar radiation, movement of the
surrounding air, precipitation and water jets;
- where mould growth, or attacks by animals but excluding termites, may occur;
- with normal levels of contaminants experienced in urban areas with industrial activities scattered
over the whole area, and/or with heavy traffic;
- in areas with sources of sand or dust, including urban areas;
- with significant vibration and shock, e.g. transmitted from machines or passing vehicles in the
vicinity, etc.
...