SIST EN 12809:2003/A1:2005/AC:2006
(Amendment)Residential independent boilers fired by solid fuel - Nominal heat output up to 50 kW - Requirements and test methods
Residential independent boilers fired by solid fuel - Nominal heat output up to 50 kW - Requirements and test methods
Specifies requirements relating to the design, manufacture, construction, performance (efficiency and emission), safety, instructions and marking together with associated test methods and test fuels for type testing residential independent heating and hot water boilers fired by solid fuel.
Heizkessel für feste Brennstoffe - Nennwärmeleistung bis 50 kW - Anforderungen und Prüfungen
Chaudieres domestiques a combustible solide destinées a etre implantées dans le volume habitable - Puissance calorifique nominale inférieure ou égale a 50 kW - Exigences et méthodes d'essai
Grelni kotli na trdna goriva - Imenska grelna moč do 50 kW - Zahteve in preskusne metode - Popravek AC k dopolnilu A1
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Heizkessel für feste Brennstoffe - Nennwärmeleistung bis 50 kW - Anforderungen und PrüfungenChaudieres domestiques a combustible solide destinées a etre implantées dans le volume habitable - Puissance calorifique nominale inférieure ou égale a 50 kW - Exigences et méthodes d'essaiResidential independent boilers fired by solid fuel - Nominal heat output up to 50 kW - Requirements and test methods97.100.30Grelniki na trdo gorivoSolid fuel heaters91.140.10Sistemi centralnega ogrevanjaCentral heating systemsICS:Ta slovenski standard je istoveten z:EN 12809:2001/A1:2004/AC:2006SIST EN 12809:2003/A1:2005/AC:2006en,de01-november-2006SIST EN 12809:2003/A1:2005/AC:2006SLOVENSKI
STANDARD
SIST EN 12809:2003/A1:2005/AC:2006
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 12809:2001/A1:2004/ACJune 2006Juin 2006Juni 2006ICS 91.140.10English versionVersion FrançaiseDeutsche FassungResidential independent boilers fired by solid fuel - Nominal heat output upto 50 kW - Requirements and test methodsChaudières domestiques à combustiblesolide destinées à être implantées dans levolume habitable - Puissance calorifiquenominale inférieure ou égale à 50 kW -Exigences et méthodes d'essaiHeizkessel für feste Brennstoffe -Nennwärmeleistung bis 50 kW -Anforderungen und PrüfungenThis corrigendum becomes effective on 21 June 2006 for inco
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.