Plastics piping systems for non-pressure underground drainage and sewerage - Polypropylene (PP) - Part 1: Specifications for pipes, fittings and the system

This Part of EN 1852 specifies the requirements for solid wall pipes, fittings and the system of polypropylene (PP) piping systems in the field of
- non-pressure underground drainage and sewerage outside the building structure (application area code "U"), and
- non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code "D") and outside the building structure.
This is reflected in the marking of products by "U" and "UD".
This standard covers PP materials without mineral modifiers.
It also specifies the test parameters for the test methods referred to in this standard.
This standard covers a range of nominal sizes, and pipe series and gives recommendations concerning colours.
NOTE 1   It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
In conjunction with Part 2 and Part 3 of EN 1852 it is applicable to PP pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage.
This standard is applicable to PP pipes and fittings with or without an integral socket.
NOTE 2   The fittings can be manufactured by injection-moulding or be fabricated from pipes and/or mouldings.
NOTE 3   Requirements and limiting values for application area code "D" are given in Table 3, Table 6 and Table 12.
NOTE 4   Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be connected to pipes and fittings conforming to this standard, when they conform to the requirements for joint dimensions given in clause 6 and to the requirements of Table 12.

Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Polypropylen (PP) - Teil 1: Anforderungen an Rohre, Formstücke und das Rohrleitungssystem

Dieser Teil der EN 1852 legt Anforderungen an Vollwandrohre, Formstücke und das Rohrleitungssystem aus Polypropylen (PP) für Abwasserkanäle und  leitungen fest, die in erdverlegten Schwerkraftentwässerungs¬systemen
   außerhalb der Gebäudestruktur (Anwendungskennzeichen U) sowie
   innerhalb der Gebäudestruktur (Anwendungskennzeichen D) und außerhalb der Gebäudestruktur
eingesetzt werden.
Die Wahl des Anwendungsgebietes wird durch die Kennzeichnung U bzw. UD der Rohrleitungsteile angezeigt.
Diese Norm gilt für Werkstoffe aus Polypropylen ohne mineralische Additive.
Sie legt auch die Prüfparameter für die Prüfverfahren fest, auf die in dieser Norm verwiesen wird.
Diese Norm enthält darüber hinaus Festlegungen für Nennweiten und Rohrserien und gibt Empfehlungen für die Auswahl der Einfärbung von Rohrleitungsteilen.
ANMERKUNG 1   Der Anwender bzw. Auftraggeber ist unter Berücksichtigung der eigenen Anforderungen sowie der geltenden nationalen Festlegungen und Verlegepraktiken für die entsprechende Auswahl dieser Kriterien verantwortlich.
Zusammen mit Teil 2 und Teil 3 der EN 1852 gilt dieser Teil für Rohre und Formstücke aus PP, ihre Verbindungen untereinander sowie mit Rohrleitungsteilen aus anderen Kunststoffen oder Rohrwerkstoffen, die für erdverlegte Abwasserkanäle und  leitungen vorgesehen sind.
Diese Norm ist anwendbar auf Rohre und Formstücke aus PP sowohl mit oder ohne angeformter Muffe.
ANMERKUNG 2   Die Formstücke können im Spritzguss, aus Rohren und/oder aus Spritzgussteilen hergestellt sein.
ANMERKUNG 3   Anforderungen und mögliche Einschränkungen für Anwendungsgebiete mit Anwendungskennzeichen D sind in Tabelle 3, Tabelle 6 bzw. in Tabelle 12 aufgeführt.

Systemes de canalisations en plastique pour les branchements et les collecteurs d'assainissement enterrés sans pression - Polypropylene (PP) - Partie 1 : Spécifications pour tubes, raccords et le systeme

La présente partie de l'EN 1852 spécifie les exigences pour les tubes à paroi compacte, les raccords et le système de canalisations en polypropylène (PP) destinés à être utilisés pour :
- les branchements et des collecteurs d'assainissement enterrés sans pression à l'extérieur de la structure du bâtiment (code de zone d'application « U ») ; et
- les branchements et des collecteurs d'assainissement enterrés sans pression aussi bien à l'intérieur de la structure du bâtiment (code de zone d'application « D ») qu'à l'extérieur de celle-ci.
Ceci se retrouve dans le marquage « U » et « UD » des produits.
La présente norme couvre les matières PP sans modificateurs minéraux.
Elle spécifie également les paramètres d'essai pour les méthodes d'essai auxquelles se réfère cette norme.
La présente Norme couvre une gamme de dimensions nominales, une gamme de séries de tubes et donne des recommandations concernant les couleurs.
NOTE 1   Il est de la responsabilité de l'acheteur ou du prescripteur de procéder aux choix appropriés, prenant en compte les exigences particulières et les règlements nationaux et pratiques nationales appropriés.
Conjointement aux Parties 2 et 3 de l'EN 1852, elle s'applique aux tubes et aux raccords en PP, à leurs assemblages ainsi qu'aux assemblages avec des composants en d'autres matières plastiques ou non, destinés à être utilisés pour les systèmes de canalisations pour branchements et collecteurs d'assainissement enterrés sans pression.
La présente Norme européenne est applicable aux tubes et aux raccords en PP avec ou sans emboîture.
NOTE 2    Les raccords peuvent être fabriqués par moulage par injection ou peuvent être façonnés à partir de tubes et/ou de pièces moulées.
NOTE 3    Les exigences et les valeurs limites pour le code de zone d'application « D » sont données aux Tableau 4, Tableau 7 et Tableau 14.
[...]

Cevni sistemi iz polimernih materialov za odpadno vodo in kanalizacijo, ki delujejo po težnostnem principu in so položeni v zemljo - Polipropilen (PP) - 1. del: Specifikacije za cevi, fitinge in sistem

General Information

Status
Withdrawn
Publication Date
04-May-2009
Withdrawal Date
12-Feb-2018
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
13-Feb-2018
Due Date
08-Mar-2018
Completion Date
13-Feb-2018

Relations

Buy Standard

Standard
EN 1852-1:2009
English language
34 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 1852-1:2009
01-junij-2009
1DGRPHãþD
SIST EN 1852-1:1997/A1:2003
SIST EN 1852-1:1999
Cevni sistemi iz polimernih materialov za odpadno vodo in kanalizacijo, ki delujejo
po težnostnem principu in so položeni v zemljo - Polipropilen (PP) - 1. del:
Specifikacije za cevi, fitinge in sistem
Plastics piping systems for non-pressure underground drainage and sewerage -
Polypropylene (PP) - Part 1: Specifications for pipes, fittings and the system
Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -
leitungen - Polypropylen (PP) - Teil 1: Anforderungen an Rohre, Formstücke und das
Rohrleitungssystem
Systemes de canalisations en plastique pour les branchements et les collecteurs
d'assainissement enterrés sans pression - Polypropylene (PP) - Partie 1 : Spécifications
pour tubes, raccords et le systeme
Ta slovenski standard je istoveten z: EN 1852-1:2009
ICS:
23.040.01 Deli cevovodov in cevovodi Pipeline components and
na splošno pipelines in general
93.030 Zunanji sistemi za odpadno External sewage systems
vodo
SIST EN 1852-1:2009 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 1852-1:2009

---------------------- Page: 2 ----------------------

SIST EN 1852-1:2009
EUROPEAN STANDARD
EN 1852-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2009
ICS 23.040.01; 93.030 Supersedes EN 1852-1:1997
English Version
Plastics piping systems for non-pressure underground drainage
and sewerage - Polypropylene (PP) - Part 1: Specifications for
pipes, fittings and the system
Systèmes de canalisations en plastique pour les Kunststoff-Rohrleitungssysteme für erdverlegte drucklose
branchements et les collecteurs d'assainissement enterrés Abwasserkanäle und -leitungen - Polypropylen (PP) - Teil
sans pression - Polypropylène (PP) - Partie 1 : 1: Anforderungen an Rohre, Formstücke und das
Spécifications pour tubes, raccords et le système Rohrleitungssystem
This European Standard was approved by CEN on 14 February 2009.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the
official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2009 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 1852-1:2009: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 1852-1:2009
EN 1852-1:2009 (E)
Contents Page
Foreword . 4
1 Scope . 5
2 Normative references . 5
3 Definitions, symbols and abbreviations . 6
3.1 Definitions . 6
3.2 Symbols . 8
3.3 Abbreviations . 9
4 Material . 9
4.1 PP compound. 9
4.2 Reprocessable and recyclable material . 10
4.3 Melt mass-flow rate . 10
4.4 Resistance to internal pressure . 10
4.5 Thermal stability (OIT) . 11
4.6 Sealing ring retaining means . 11
5 General characteristics . 11
5.1 Appearance . 11
5.2 Colour . 11
6 Geometrical characteristics . 12
6.1 General . 12
6.2 Dimensions of pipes . 12
6.2.1 Outside diameters . 12
6.2.2 Outside diameters with close tolerances (CT) . 12
6.2.3 Length of pipes . 13
6.2.4 Chamfering . 14
6.2.5 Wall thicknesses . 14
6.3 Dimensions of fittings . 15
6.3.1 Outside diameters . 15
6.3.2 Design lengths . 15
6.3.3 Wall thicknesses . 16
6.4 Dimensions of sockets and spigots. 17
6.4.1 Diameters and lengths of elastomeric ring seal sockets and spigots . 17
6.4.2 Wall thicknesses of sockets . 19
6.5 Types of fittings . 20
7 Mechanical characteristics . 23
7.1 Mechanical characteristics of pipes . 23
7.1.1 General requirements . 23
7.1.2 Additional mechanical requirements . 23
7.2 Mechanical characteristics of fittings . 24
8 Physical characteristics . 24
8.1 Physical characteristics of pipes . 24
8.2 Physical characteristics of fittings . 25
9 Performance requirements . 25
10 Sealing rings . 26
2

---------------------- Page: 4 ----------------------

SIST EN 1852-1:2009
EN 1852-1:2009 (E)
11 Marking . 26
11.1 General . 26
11.2 Minimum required marking of pipes . 27
11.3 Minimum required marking of fittings . 27
11.4 Additional marking . 28
Annex A (normative) Geometrical characteristics of pipes following S-series 11,2 . 29
A.1 General . 29
A.2 Wall thickness of pipes . 29
A.3 Wall thickness of sockets. 30
Annex B (informative) General characteristics of PP pipes and fittings . 31
B.1 General . 31
B.2 Material characteristics . 31
B.3 Ring stiffness . 31
B.4 Creep ratio . 31
B.5 Chemical resistance . 32
B.6 Abrasion resistance . 32
B.7 Hydraulic roughness . 32
B.8 Diametric deflection . 32
Annex C (informative) Product standards of components that can be connected to components
conforming to this standard . 33
Bibliography . 34


3

---------------------- Page: 5 ----------------------

SIST EN 1852-1:2009
EN 1852-1:2009 (E)
Foreword
This document (EN 1852-1:2009) has been prepared by Technical Committee CEN/TC 155 “Plastics piping
systems and ducting systems”, the secretariat of which is held by NEN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by September 2009, and conflicting national standards shall be
withdrawn at the latest by September 2009.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 1852-1:1997.
The System Standards are based on the results of the work undertaken in ISO/TC 138 "Plastics pipes, fittings
and valves for the transport of fluids", which is a Technical Committee of the International Organization for
Standardization (ISO).
The System Standards are supported by separate standards on test methods to which references are made
throughout the System Standard.
The System Standards are consistent with general standards on functional requirements and on
recommended practice for installation.
EN 1852 consists of the following parts, under the general title Plastics piping systems for non-pressure
underground drainage and sewerage − Polypropylene (PP)
 Part 1: Specifications for pipes, fittings and the system (the present standard);
 Part 2: Guidance for the assessment of conformity (CEN Technical Specification);
 Part 3: Guidance for installation (CEN Technical Specification).
This part of EN 1852 includes Annex A (normative): Geometrical characteristics of pipes following S-series
11,2, Annex B (informative): General characteristics of PP pipes and fittings and Annex C (informative):
Product standards of components that can be connected to components conforming to this standard.
Plastics piping systems made of PP with mineral modifiers (PP-MD) are covered by EN 14758-1 [1].
The main change in the revised document is: EN 1852 gave wall thicknesses for two different E-modulus and
S-series, and for E-modulus above 1 700 MPa the designation PP-HM was used. In this revised document the
following changes are made:
 new S-series for SN 8 are introduced replacing the previous S-series;
 the previous S-series 11,2 for SN 8 is given in Annex A;
 new ring stiffness class SN 16 is introduced;
 the wall thickness table for fittings is modified;
 designation PP-HM is no longer used;
 impact resistance (staircase method) test temperature changed from 0 °C to −10 °C.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
4

---------------------- Page: 6 ----------------------

SIST EN 1852-1:2009
EN 1852-1:2009 (E)
1 Scope
This part of EN 1852 specifies the requirements for solid wall pipes, fittings and the system of polypropylene
(PP) piping systems intended for use for:
 non-pressure underground drainage and sewerage outside the building structure (application area code
"U"), and
 non-pressure underground drainage and sewerage for both buried in ground within the building structure
(application area code "D") and outside the building structure.
This is reflected in the marking of products by "U" and "UD".
This standard covers PP materials without mineral modifiers.
It also specifies the test parameters for the test methods referred to in this standard.
This standard covers a range of nominal sizes, and pipe series and gives recommendations concerning
colours.
NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects,
taking into account their particular requirements and any relevant national regulations and installation practices or codes.
In conjunction with Part 2 and Part 3 of EN 1852 it is applicable to PP pipes and fittings, their joints and to
joints with components of other plastics and non-plastics materials intended to be used for buried piping
systems for non-pressure underground drainage and sewerage.
This standard is applicable to PP pipes and fittings with or without an integral socket.
NOTE 2 The fittings can be manufactured by injection-moulding or be fabricated from pipes and/or mouldings.
NOTE 3 Requirements and limiting values for application area code "D" are given in Table 4, Table 7 and Table 14.
NOTE 4 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can
be connected to pipes and fittings conforming to this standard, when they conform to the requirements for joint dimensions
given in Clause 6 and to the requirements of Table 14.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 681-1, Elastomeric seals ― Materials requirements for pipe joint seals used in water and drainage
applications ― Part 1: Vulcanized rubber
EN 681-2, Elastomeric seals ― Materials requirements for pipe joint seals used in water and drainage
applications ― Part 2: Thermoplastic elastomers
EN 728, Plastics piping and ducting systems ― Polyolefin pipes and fittings ― Determination of oxidation
induction time
EN 744:1995, Plastics piping and ducting systems ― Thermoplastics pipes ― Test method for resistance to
external blows by the round-the-clock method
EN 1053, Plastics piping systems ― Thermoplastics piping systems for non-pressure applications ― Test
method for watertightness
5

---------------------- Page: 7 ----------------------

SIST EN 1852-1:2009
EN 1852-1:2009 (E)
EN 1055:1996, Plastics piping systems ― Thermoplastics piping systems for soil and waste discharge inside
buildings ― Test method for resistance to elevated temperature cycling
EN 1277:2003, Plastics piping systems ― Thermoplastics piping systems for buried non-pressure applications
― Test methods for leaktightness of elastomeric sealing ring type joints
EN 1411:1996, Plastics piping and ducting systems ― Thermoplastics pipes ― Determination of resistance to
external blows by the staircase method
EN 12061, Plastics piping systems ― Thermoplastics fittings ― Test method for impact resistance
EN 12256, Plastics piping systems ― Thermoplastics fittings ― Test method for mechanical strength or
flexibility of fabricated fittings
EN ISO 472:2001, Plastics ― Vocabulary (ISO 472:1999)
EN ISO 580:2005, Plastics piping and ducting systems ― Injection-moulded thermoplastics fittings ―
Methods for visually assessing the effects of heating (ISO 580:2005)
EN ISO 1043-1:2001, Plastics ― Symbols and abbreviated terms ― Part 1: Basic polymers and their special
characteristics (ISO 1043-1:2001)
EN ISO 1133, Plastics ― Determination of the melt mass-flow rate (MFR) and the melt volume-flow rate
(MVR) of thermoplastics (ISO 1133:2005)
EN ISO 1167-1, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids ― Determination
of the resistance to internal pressure ― Part 1: General method (ISO 1167-1:2006)
EN ISO 2505:2005, Thermoplastics pipes ― Longitudinal reversion ― Test method and parameters
(ISO 2505:2005)
EN ISO 3126, Plastics piping systems ― Plastics components ― Determination of dimensions
(ISO 3126:2005)
EN ISO 9969, Thermoplastics pipes ― Determination of ring stiffness (ISO 9969:2007)
CEN/TS 14541:2007, Plastics pipes and fittings for non-pressure applications ― Utilisation of non-virgin
PVC-U, PP and PE materials
3 Definitions, symbols and abbreviations
3.1 Definitions
For the purposes of this document, the terms and definitions given in EN ISO 472:2001, EN ISO 1043-1:2001
and the following apply.
3.1.1
application area code
code used in the marking of pipes and fittings to indicate the application area for which they are intended, as
follows:
U: application area code for the area more than 1 m from the building to which the buried piping system
is connected
D: application area code for the area under and within 1 m from the building where the pipes and the
fittings are buried in ground and are connected to the soil and waste discharge system of the building
6

---------------------- Page: 8 ----------------------

SIST EN 1852-1:2009
EN 1852-1:2009 (E)
NOTE In code D application areas, the existence of hot water discharge in addition to the external forces from the
surroundings is usual.
3.1.2 Geometrical definitions
3.1.2.1
nominal size DN/OD
numerical designation of the size of a component, which is a convenient round number approximately equal to
the manufacturing dimension of the outside diameter, in millimetres
3.1.2.2
nominal outside diameter
d
n
specified outside diameter, in millimetres, assigned to a nominal size DN/OD
3.1.2.3
outside diameter
d
e
value of the measurement of the outside diameter through its cross section at any point of a pipe or spigot end
of a fitting, rounded up to the next greater 0,1 mm
3.1.2.4
mean outside diameter
d
em
value of the measurement of the outer circumference of a pipe or spigot end of a fitting in any cross section,
divided by π (≈ 3,142), rounded to the next greater 0,1 mm
3.1.2.5
mean inside diameter of a socket
d
sm
arithmetical mean of a number of measurements of the inside diameter of a socket in the same cross section
3.1.2.6
wall thickness
e
value of the measurement of the wall thickness at any point around the circumference of a component
3.1.2.7
mean wall thickness
e
m
arithmetical mean of a number of measurements of the wall thickness, regularly spaced around the
circumference and in the same cross section of a component, including the measured minimum and the
measured maximum values of the wall thickness in that cross section
3.1.2.8
pipes series S
number for pipe designation (see ISO 4065:1996 [2])
3.1.2.9
standard dimension ratio SDR
numerical designation of a pipe series, which is a convenient round number approximately equal to the ratio of
the nominal outside diameter, d , and the minimum wall thickness, e
n min
7

---------------------- Page: 9 ----------------------

SIST EN 1852-1:2009
EN 1852-1:2009 (E)
3.1.2.10
nominal ring stiffnesss SN
numerical designation of the ring stiffness of a pipe or fitting, which is a convenient round number, relative to
2
the determined stiffness in kilonewtons per square metre (kN/m ), indicating the minimum ring stiffness of a
pipe or fitting
3.1.2.11
design length
Z
length of a fitting (e.g. the main pipe of a branch) excluding any spigot or socket length. In case of a change in
direction (e.g. in case of a bend or the service pipe of a branch), it is the length from one end to the
intersection of the straight axis of this end with the straight axis of the other end of the fitting, excluding any
spigot or socket length (see the dimensions Z and Z in e.g. Figure 7 and Figure 11)
1 2
3.1.3 Material definitions
3.1.3.1
virgin material
material in a form such as granules or powder that has not been subjected to use or processing other than
that required for its manufacture and to which no reprocessable or recyclable material has been added
3.1.3.2
own reprocessable material
material prepared from rejected unused pipes or fittings, including trimmings from the production of pipes or
fittings, that will be reprocessed in a manufacturer’s plant after having been previously processed by the same
manufacturer by a process such as moulding or extrusion, and for which the complete formulation is known
3.1.3.3
external reprocessable material
material comprising either one of the following forms:
a) material from rejected unused pipes or fittings or trimmings there from, that will be reprocessed and that
were originally processed by another manufacturer
b) material from the production of unused PP products other than pipes and fittings, regardless of where
they are manufactured
3.1.3.4
recyclable material
material comprising either one of the following forms:
a) material from used pipes or fittings which have been cleaned and crushed or ground
b) material from used PP products other than pipes or fittings which have been cleaned and crushed or
ground
3.1.4
solid wall pipe
smooth internal and external surface with same compound/formulation throughout the wall
3.2 Symbols
A : length of engagement
C : depth of sealing zone
d : outside diameter
e
8

---------------------- Page: 10 ----------------------

SIST EN 1852-1:2009
EN 1852-1:2009 (E)
d : mean outside diameter
em
d : nominal outside diameter
n
d : mean inside diameter of a socket
sm
e : wall thickness
e : mean wall thickness
m
e : wall thickness of a socket
2
e : wall thickness in the groove area
3
l : effective length of a pipe
L : length of spigot
1
M : length of spigot of a plug
R : radius of swept fittings
Z : design length of (a part of) a fitting
α : nominal angle of a fitting
3.3 Abbreviations
CT : close tolerance
DN : nominal size
DN/OD : nominal size, outside diameter related
MFR : melt mass-flow rate
OIT : oxidation induction time
PP : polypropylene
S : pipes series
SDR : standard dimension ratio
SN : nominal ring stiffness
TIR : true impact rate
4 Material
4.1 PP compound
The compound for pipes and fittings shall be PP base material without mineral modifiers, to which are added
those additives that are needed to facilitate the manufacture of components conforming to the requirements of
this standard.
NOTE PP-based materials with mineral modifiers (PP-MD) are covered in EN 14758-1 [1].
9

---------------------- Page: 11 ----------------------

SIST EN 1852-1:2009
EN 1852-1:2009 (E)
4.2 Reprocessable and recyclable material
In addition to virgin material the use of the manufacturer’s own reprocessable material obtained during the
production and testing of products conforming to this standard is permitted.
External reprocessable and recyclable material of pipes and fittings with agreed specification is permitted
according to the rules in CEN/TS 14541 provided it originates from products in accordance with this European
Standard and national standards replaced by this European Standard. Such materials can only be used for
S 20 and S 16 and S 12,5/SN 8.
4.3 Melt mass-flow rate
Pipes and fittings shall be made from materials with an MFR as follows:
MFR (230/2,16) ≤ 1,5 g/10 min.
The MFR of the base material shall be tested in accordance with EN ISO 1133, using the test parameters:
temperature 230 °C and loading mass 2,16 kg.
Materials for pipes and fittings for butt fusion joints shall be designated by the following classes with regard to
the MFR:
Class A: MFR ≤ 0,3 g/10 min;
Class B: 0,3 g/10 min < MFR ≤ 0,6 g/10 min;
Class C: 0,6 g/10 min < MFR ≤ 0,9 g/10 min;
Class D: 0,9 g/10 min < MFR ≤ 1,5 g/10 min.
Only pipes and fittings made from materials of the same or an adjacent MFR-class may be fused together.
4.4 Resistance to internal pressure
When tested in accordance with the test method as specified in Table 1, using the indicated parameters, the
material shall have characteristics conforming to the requirements given in Table 1.
The material shall be tested in the form of a pipe.
10

---------------------- Page: 12 ----------------------

SIST EN 1852-1:2009
EN 1852-1:2009 (E)
Table 1 — Material characteristics (long-term behaviour)
Characteristic Requirements Test parameters Test method
Resistance to No failure during End caps Type A or type B EN ISO 1167-1
internal pressure the test period Test temperature 80 °C
Orientation free
Number of test pieces 3
Circumferential (hoop) stress 4,2 MPa
Conditioning period 1 h
Type of test Water-in-water
Test period 140 h
End caps Types A or B
Test temperature 95 °C
Orientation free
Number of test pieces 3
Circumferential (hoop) stress 2,5 MPa
Conditioning period 1 h
Type of test Water-in-water
Test period 1 000 h

4.5 Thermal stability (OIT)
The OIT test shall be carried out on components intended for jointing by fusion or welding.
The test shall be carried out in accordance with EN 728 using a test temperature of 200 °C. The oxidation
induction time of the material shall not be less than 8 min.
4.6 Sealing ring retaining means
Sealing rings may be retained using means made from polymers other than PP.
5 General characteristics
5.1 Appearance
When viewed without magnification, the following requirements apply.
The internal and external surfaces of pipes and fittings shall be smooth, clean and free from grooving,
blistering, impurities and pores and any
...