This part of IEC 60364 covers requirements for low-voltage generating sets. Particular
requirements for supplies for safety services are given in clause 556 while clause 559 applies
to the selection and erection of luminaires and lighting installations intended to be part of the
fixed installation. Electrical standby supply systems, other than for safety services, are outside the scope of this standard. This part of IEC 60364 does not apply for installations in hazardous areas (BE3). NOTE 1 Requirements of the public supply undertaking should be ascertained before a generating set is installed in an installation which is connected to the public supply. NOTE 2 For additional requirements for hazardous areas, see the IEC 60079 and IEC 61241 series.
Installations électriques des bâtiments - Partie 5-55: Choix et mise en oeuvre des matériels électriques - Autres matériels
Traite des prescriptions relatives aux groupes générateurs. Des prescriptions particulières pour l'alimentation des installations de sécurité sont données à l'article 556 alors que l'article 559 traite du choix et de la mise en uvre des luminaires et des installations d'éclairage destinées à faire partie de l'installation fixe. [
]Cette version française découle de la publication d'origine bilingue dont les pages anglaises ont été supprimées. Les numéros de page manquants sont ceux des pages supprimées. [
] Cette version consolidée comprend la première édition (2001) et son amendement 1 (2001). Il n'est donc pas nécessaire de commander l'amendement avec cette publication.
Električne inštalacije zgradb - 5-55. del: Izbira in namestitev električne opreme - Druga oprema
General Information
Relations
Overview
IEC 60364-5-55 - Installations électriques des bâtiments (Partie 5-55) covers the selection and erection of “other equipment” in building electrical installations, with particular emphasis on groups générateurs (generating sets / generators). This part of the IEC 60364 series provides requirements and guidance to ensure safe, reliable installation and integration of generators and associated equipment into fixed electrical installations. The published consolidated version includes the first edition (2001) and Amendment 1 (2001).
Key topics and requirements
The standard addresses high-level requirements related to:
- Groups générateurs (generators and generating sets) - prescriptions for selection, siting and integration into building electrical systems.
- Supply of safety installations - specific provisions for powering safety circuits and installations (see article 556 for these particular requirements).
- Luminaires and lighting installations - guidance on the choice and installation of luminaires and fixed lighting systems intended to be part of the building installation (see article 559).
- Selection and erection principles for “other” equipment not covered elsewhere in Part 5: ensuring compatibility, protection, and safe operation within the fixed installation.
- Compliance and documentation - requirements to document equipment selection and connection arrangements consistent with the IEC 60364 series.
Note: This consolidated French-language publication derives from the original bilingual edition; missing pages correspond to removed English pages.
Practical applications
IEC 60364-5-55 is used to:
- Define safe installation practices for on-site generating sets (standby, emergency or prime power).
- Ensure correct supply arrangements for safety-critical systems (fire detection, emergency lighting, ventilation).
- Guide selection and installation of luminaires and fixed lighting within building electrical work.
- Support compliance checks during design reviews, construction inspections and commissioning of electrical installations.
Who should use this standard
- Electrical designers and consulting engineers specifying generator installations and fixed lighting.
- Electrical contractors and installers performing selection and erection of generators and luminaires.
- Building services and facility managers responsible for emergency power and safety systems.
- Inspectors, testing authorities and compliance officers validating installations against IEC 60364 requirements.
- Manufacturers and suppliers of generating sets and fixed lighting equipment referencing installation guidance.
Related standards
- IEC 60364 series (general rules for electrical installations of buildings) - consult other parts of IEC 60364 for complementary requirements on earthing, protection and wiring systems.
- National adoptions (e.g., SIST IEC 60364-5-55:2006) may include local application rules.
Keywords: IEC 60364-5-55, electrical installations, generators, groups générateurs, luminaires, emergency power, selection and erection, building electrical equipment, electrical safety standard.
Frequently Asked Questions
SIST IEC 60364-5-55:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment". This standard covers: This part of IEC 60364 covers requirements for low-voltage generating sets. Particular requirements for supplies for safety services are given in clause 556 while clause 559 applies to the selection and erection of luminaires and lighting installations intended to be part of the fixed installation. Electrical standby supply systems, other than for safety services, are outside the scope of this standard. This part of IEC 60364 does not apply for installations in hazardous areas (BE3). NOTE 1 Requirements of the public supply undertaking should be ascertained before a generating set is installed in an installation which is connected to the public supply. NOTE 2 For additional requirements for hazardous areas, see the IEC 60079 and IEC 61241 series.
This part of IEC 60364 covers requirements for low-voltage generating sets. Particular requirements for supplies for safety services are given in clause 556 while clause 559 applies to the selection and erection of luminaires and lighting installations intended to be part of the fixed installation. Electrical standby supply systems, other than for safety services, are outside the scope of this standard. This part of IEC 60364 does not apply for installations in hazardous areas (BE3). NOTE 1 Requirements of the public supply undertaking should be ascertained before a generating set is installed in an installation which is connected to the public supply. NOTE 2 For additional requirements for hazardous areas, see the IEC 60079 and IEC 61241 series.
SIST IEC 60364-5-55:2006 is classified under the following ICS (International Classification for Standards) categories: 91.140.50 - Electricity supply systems. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST IEC 60364-5-55:2006 has the following relationships with other standards: It is inter standard links to SIST IEC 60364-5-55:2006/A2:2009, SIST IEC 60364-5-55:2006/A1:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase SIST IEC 60364-5-55:2006 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2006
(OHNWULþQHLQãWDODFLMH]JUDGEGHO,]ELUDLQQDPHVWLWHYHOHNWULþQHRSUHPH
'UXJDRSUHPD
Electrical installations of buildings - Part 5-55: Selection and erection of electrical
equipment - Other equipment
Installations électriques des bâtiments - Partie 5-55: Choix et mise en oeuvre des
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...