SIST EN 60297-3-108:2015
(Main)Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series -- Part 108: Dimensions of R-type subracks and plug-in units
Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series -- Part 108: Dimensions of R-type subracks and plug-in units
IEC 60297-3-108:2014 provides dimensions and features for R-type subracks and plug-in units, i.e. ruggedized variants of the mechanical structures of the 482,6 mm (19 in) series, with enhanced vibration and shock resistance and/or improved EMC performance, for use in more harsh environment. This leads to a subrack standard which is externally compatible with IEC 60297-3-100 but internally largely incompatible with IEC 60297-3-101. R-type subracks, chassis integrated subracks and plug-in units incorporate dimensions and features which provide for a higher level of ruggedness, compared with IEC 60297-3-101 (test set-up and load definitions are selected from IEC 61587-1 and IEC 61587-5).
Key words: R-Type, Subracks, Plug-in unit
Bauweisen für elektronische Einrichtungen - Maße der 482,6-mm-(19-in-)Bauweise - Teil 3-108: Maße von Baugruppenträgern und steckbaren Baugruppen Typ R
Structures mécaniques pour équipements électroniques - Dimensions des structures mécaniques de la série 482,6 mm (19 pouces) - Partie 3-108: dimensions des bacs de type r et des blocs enfichables
IEC 60297-3-108:2014 donne les dimensions et caractéristiques des bacs de type R et des blocs enfichables, c'est-à-dire des variantes renforcées des structures mécaniques de la série 482,6 mm (19 pouces), avec une augmentation de la résistance aux vibrations et aux chocs et/ou une amélioration des performances CEM, pour utilisation dans un environnement plus sévère. Ceci donne lieu à une norme sur les bacs, qui est compatible d'un point de vue externe avec l'IEC 60297-3-100, mais largement incompatible d'un point de vue interne avec l'IEC 60297-3-101. Les bacs de type R, les bacs intégrés au châssis et les blocs enfichables comportent des dimensions et des caractéristiques qui fournissent un niveau plus élevé de robustesse, par rapport à l'IEC 60297-3-101 (les définitions relatives au montage d'essai et à la charge sont choisies dans l'IEC 61587-1 et l'IEC 61587-5).
Mots-clés: type R, bacs, bloc enfichable
Mehanske konstrukcije za elektronsko opremo - Mere mehanskih konstrukcij serije 482,6 mm (19 palcev) - 3-108. del: Mere okvirov vrste R in vtičnih enot
Ta del standarda IEC 60297 podaja dimenzije in lastnosti okvirov vrste R in vtičnih enot, tj. odpornejše različice mehanskih struktur serije 482,6 mm (19 in) z izboljšano odpornostjo na vibracije in udarce in/ali izboljšanim delovanjem elektromagnetne združljivosti, namenjene uporabi v ostrejših okoljih. S tem se pridobi standard okvira, ki je eksterno združljiv s standardom IEC 60297-3-100, interno pa večinoma nezdružljiv s standardom IEC 60297-3-101. Dimenzije in lastnosti okvirov tipa R, okvirov, vgrajenih v šasijo, in vtičnih enot nudijo večjo stopnjo trpežnosti v primerjavi s standardom IEC 60297-3-101 (priprava preskusa in opredelitve bremena so izbrane iz standardov IEC 61587-1 in IEC 61587-5).
General Information
Overview
EN 60297-3-108:2015 (CLC adoption of IEC 60297-3-108:2014) defines the mechanical dimensions and ruggedized features of R‑type subracks and plug‑in units for the 482.6 mm (19 in) equipment series. The standard specifies externally compatible mechanical interfaces for tougher environments - providing enhanced vibration/shock resistance and improved EMC performance for use where standard 19 in equipment is not robust enough.
Key points:
- Targets R‑Type subracks (RA, RB) and chassis‑integrated subracks
- Focuses on ruggedness, EMC provisions and environmental test selections
- Externally compatible with IEC 60297‑3‑100 (basic 19 in dimensions) but internally largely incompatible with IEC 60297‑3‑101
Key Topics and Requirements
The standard covers technical topics and mandatory features that support ruggedized 19 in equipment design:
- Arrangement and mounting - front and rear mounting dimensions for RA and RB subracks; guide rails and mounting flanges
- Mechanical features - injector/extractor handle specifications, chassis/subrack mounting supports, and nomenclature
- Environmental and mechanical testing - static/dynamic load, seismic, vibration and shock considerations referenced to IEC 61587‑1 and IEC 61587‑5
- Electromagnetic shielding (EMC) - provisions and tests for shielding performance (see IEC 61587‑3)
- Thermal management - air ducting and forced‑air cooling guidance (Annex C)
- Printed circuit board and plug‑in unit interfaces - PCB envelope and front‑panel plug‑in unit dimensions
- Normative annexes - mounting support (Annex A), environmental tests (Annex B), thermal guidance (Annex C), and comparison with IEC 60297‑3‑101 (Annex D)
Applications and Who Uses It
EN 60297‑3‑108 is intended for organizations and professionals who design, specify or certify rugged 19 in electronic equipment, including:
- Mechanical and systems engineers designing ruggedized enclosures and subracks
- Product designers of telecom, transport, industrial control and defence equipment needing higher shock/vibration and EMC performance
- Rack and chassis manufacturers, integrators and OEMs requiring standardized interoperability at the front panel level
- Test laboratories and compliance engineers referencing environmental and EMC test setups
Using this standard helps ensure mechanical interchangeability where required, higher reliability in harsh environments, and clearer requirements for EMC, seismic and thermal performance.
Related Standards
- IEC/EN 60297‑3‑100 (basic 19 in dimensions)
- IEC/EN 60297‑3‑101 (standard subracks and plug‑in units) - internal incompatibility noted
- IEC/EN 61587 series (environmental, EMC and seismic tests)
- IEC 60297‑3‑105 and IEC/TS 62610‑2 (chassis and thermal guidance)
Keywords: R‑Type, Subracks, Plug‑in unit, 19 inch, 482.6 mm, ruggedized, EMC, vibration, IEC 60297, EN 60297‑3‑108, CLC.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2015
0HKDQVNHNRQVWUXNFLMH]DHOHNWURQVNRRSUHPR0HUHPHKDQVNLKNRQVWUXNFLMVHULMH
PPSDOFHYGHO0HUHRNYLURYYUVWH5LQYWLþQLKHQRW
0HFKDQLFDOVWUXFWXUHVIRUHOHFWURQLFHTXLSPHQW'LPHQVLRQVRIPHFKDQLFDOVWUXFWXUHVRI
WKHPPLQVHULHV3DUW'LPHQVLRQVRI5W\SH
VXEUDFNVDQGSOXJLQXQLWV
Bauweisen für elektronische Einrichtungen - Maße der 482,6-mm-(19-in-)Bauweise - Teil
3-108: Maße von Baugruppenträgern und steckbaren Baugruppen Typ R
Structures mécaniques pour équipements électroniques - Dimensions des structures
mécaniques de la série 482,6 mm (19 pouces) - Partie 3-108: dimensions des bacs de
type r et des blocs enfichables
Ta slovenski standard je istoveten z: EN 60297-3-108:2015
ICS:
31.240 Mehanske konstrukcije za Mechanical structures for
elektronsko opremo electronic equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 60297-3-108
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2015
ICS 31.240
English Version
Mechanical structures for electronic equipment - Dimensions of
mechanical structures of the 482,6 mm (19 in) series - Part 3-
108: Dimensions of R-type subracks and plug-in units
(IEC 60297-3-108:2014)
Structures mécaniques pour équipements électroniques - Bauweisen für elektronische Einrichtungen - Maße der
Dimensions des structures mécaniques de la série 482,6 482,6-mm-(19-in-)Bauweise - Teil 3-108: Maße von
mm (19 pouces) - Partie 3-108: dimensions des bacs de Baugruppenträgern und steckbaren Baugruppen Typ R
type r et des blocs enfichables (IEC 60297-3-108:2014)
(IEC 60297-3-108:2014)
This European Standard was approved by CENELEC on 2014-10-14. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60297-3-108:2015 E
Foreword
The text of document 48D/565/FDIS, future edition 1 of IEC 60297-3-108, prepared by SC 48D,
"Mechanical structures for electronic equipment", of IEC TC 48, "Electromechanical components and
mechanical structures for electronic equipment" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 60297-3-108:2015.
The following dates are fixed:
(dop) 2014-07-16
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2017-10-14
standards conflicting with the
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.
Endorsement notice
The text of the International Standard IEC 60297-3-108:2014 was approved by CENELEC as a European
Standard without any modification.
- 3 - EN 60297-3-108:2015
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60297-3-100 - Mechanical structures for electronic EN 60297-3-100 -
equipment - Dimensions of mechanical
structures of the 482,6 mm (19 in) series --
Part 3-100: Basic dimensions of front
panels, subracks, chassis, racks and
cabinets
IEC 60297-3-101 - Mechanical structures for electronic EN 60297-3-101 -
equipment - Dimensions of mechanical
structures of the 482,6 mm (19 in) series --
Part 3-101: Subracks and associated plug-in
units
IEC 60297-3-105 - Mechanical structures for electronic EN 60297-3-105 -
equipment - Dimensions of mechanical
structures of the 482,6 mm (19 in) series --
Part 3-105: Dimensions and design aspects
for 1U high chassis
IEC 61587-1 - Mechanical structures for electronic EN 61587-1 -
equipment - Tests for IEC 60917 and IEC
60297 series -- Part 1: Environmental
requirements, test set-up and safety aspects
for cabinets, racks, subracks and chassis
under indoor conditions
IEC 61587-3 - Mechanical structures for electronic EN 61587-3 -
equipment - Tests for IEC 60917 and IEC
60297 -- Part 3: Electromagnetic shielding
performance tests for cabinets, racks and
subracks
IEC 61587-5 - Mechanical structures for electronic EN 61587-5 -
equipment - Tests for IEC 60917 and IEC
60297 -- Part 5: Seismic tests for chassis,
subracks, and plug-in units
IEC/TS 62610-2 - Mechanical structures for electronic - -
equipment - Thermal management for
cabinets in accordance with IEC 60297 and
IEC 60917 series - Part 2: Design guide:
Method for the determination of forced air-
cooling structure
IEC 60297-3-108 ®
Edition 1.0 2014-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Mechanical structures for electronic equipment – Dimensions of mechanical
structures of the 482,6 mm (19 in) series –
Part 3-108: Dimensions of R-type subracks and plug-in units
Structures mécaniques pour équipements électroniques – Dimensions des
structures mécaniques de la série 482,6 mm (19 pouces) –
Partie 3-108: Dimensions des bacs de type R et des blocs enfichables
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 31.240 ISBN 978-2-8322-1790-0
– 2 – IEC 60297-3-108:2014 © IEC 2014
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 8
4 Arrangement overview . 8
5 RA – type subrack . 9
5.1 General . 9
5.2 RA–type subrack rear mounting dimensions . 11
6 RB–type subrack . 12
6.1 General . 12
6.2 RB–type subrack rear mounting dimensions . 13
7 R–type subrack guide rails . 13
8 Electromagnetic shielding provisions and mounting flanges . 14
9 Chassis integrated subrack . 15
9.1 General . 15
9.2 RA– C–type chassis/subrack . 16
9.3 RB–C–type chassis/subrack . 16
10 Front panel/plug-in unit compatible with RA – type subrack . 17
11 Front panel/plug-in unit compatible with RB – type subrack . 19
12 Injector/extractor handle . 20
13 Printed board dimensions . 20
14 Dimensions. 21
15 Nomenclature . 22
15.1 Reference plane (given in square boxes of figures) . 22
15.2 Dimensions of Table 1 . 22
Annex A (normative) Mounting support . 23
A.1 Chassis/subrack mounting support in cabinets . 23
Annex B (normative) Environmental tests. 24
B.1 Static and dynamic load test . 24
B.2 Seismic test . 24
B.3 Electromagnetic shielding performance test . 24
Annex C (normative) Thermal management . 25
C.1 Air ducting . 25
Annex D (informative) Comparison of IEC 60297-3-101 with IEC 60297-3-108 . 26
Figure 1 – Subrack application . 6
Figure 2 – Arrangement of a R-type subrack and plug-in units . 9
Figure 3 – RA–type subrack front mounting dimensions . 10
Figure 4 – RA–type subrack rear mounting dimensions . 11
Figure 5 – RB–type subrack front mounting dimensions . 12
Figure 6 – RB–type subrack rear mounting dimensions . 13
Figure 7 – R–type subrack guide rails . 14
IEC 60297-3-108:2014 © IEC 2014 – 3 –
Figure 8 – R–type subrack front attachment plane and mounting flanges . 15
Figure 9 – RA – C type chassis/subrack . 16
Figure 10 – RB–C – type chassis/subrack . 17
Figure 11 – Front panel/ plug-in unit compatible with RA – type subrack . 18
Figure 12 – Front panel/ plug-in unit compatible with RB – type subrack . 19
Figure 13 – Injector/extractor handle . 20
Figure 14 – Printed board dimensions . 21
Figure A.1 – Subrack/chassis mounting support . 23
Figure C.1 – Thermal management example . 25
Table 1 – Dimensions . 21
Table D.1 – Comparison of dimensions and features . 26
– 4 – IEC 60297-3-108:2014 © IEC 2014
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
MECHANICAL STRUCTURES
FOR ELECTRONIC EQUIPMENT –
DIMENSIONS OF MECHANICAL STRUCTURES
OF THE 482,6 mm (19 in) SERIES –
Part 3-108: Dimensions of R-type subracks and plug-in units
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60297-3-108 has been prepared by subcommittee 48D:
Mechanical structures for electronic equipment, of IEC technical committee 48: Electrical
connectors and mechanical structures for electrical and electronic equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
48D/565/FDIS 48D/570/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
IEC 60297-3-108:2014 © IEC 2014 – 5 –
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of IEC 60297 series, under the general title Mechanical structures for
electronic equipment – Dimensions of mechanical structures of the 482,6 mm (19 in) series
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 6 – IEC 60297-3-108:2014 © IEC 2014
INTRODUCTION
The purpose of this standard is to establish alternative dimensions and features for subracks
and associated plug-in units, compared with IEC 60297-3-101. These alternatives allow more
sturdy designs for the load bearing members of the subrack. In addition, the plug-in units are
with alignment pins and fastened with M3 screws. Chassis integrated subracks are also part
of this standard.
The main differing dimensions/features compared with IEC 60297-3-101 are:
a) The subrack height aperture is decreased in order to increase the dimension for the top
and bottom members (most critical load bearing parts).
b) Incorporated alignment between the subrack and the plug-in units. Injecting and extracting
provisions for plug-in units.
c) The mounting flanges of the subracks are recessable. This feature meets the mounting
requirements of heavy subracks and allows the positioning to the centre of gravity.
d) Chassis integrated subracks for optimized thermal management features.
e) Comparison of dimensions and features with IEC 60297-3-101 is shown in appendix D,
Table D.1. For an application image of the subrack based on this standard see Figure 1.
IEC 60297-3-101
Conventional form factor
and normal weight, for small to medium
volume applications, e.g. general industrial
computing and data processing
IEC 60297-3-107 IEC 60297-3-108
Small form factor and light weight, Heavy weight and large form
for large volume applications, e.g. factor, for large volume
embedded systems, applications, e.g. cloud-
mobile/ubiquitous computing computing servers, telecom
systems servers
Embed
...
Frequently Asked Questions
SIST EN 60297-3-108:2015 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series -- Part 108: Dimensions of R-type subracks and plug-in units". This standard covers: IEC 60297-3-108:2014 provides dimensions and features for R-type subracks and plug-in units, i.e. ruggedized variants of the mechanical structures of the 482,6 mm (19 in) series, with enhanced vibration and shock resistance and/or improved EMC performance, for use in more harsh environment. This leads to a subrack standard which is externally compatible with IEC 60297-3-100 but internally largely incompatible with IEC 60297-3-101. R-type subracks, chassis integrated subracks and plug-in units incorporate dimensions and features which provide for a higher level of ruggedness, compared with IEC 60297-3-101 (test set-up and load definitions are selected from IEC 61587-1 and IEC 61587-5). Key words: R-Type, Subracks, Plug-in unit
IEC 60297-3-108:2014 provides dimensions and features for R-type subracks and plug-in units, i.e. ruggedized variants of the mechanical structures of the 482,6 mm (19 in) series, with enhanced vibration and shock resistance and/or improved EMC performance, for use in more harsh environment. This leads to a subrack standard which is externally compatible with IEC 60297-3-100 but internally largely incompatible with IEC 60297-3-101. R-type subracks, chassis integrated subracks and plug-in units incorporate dimensions and features which provide for a higher level of ruggedness, compared with IEC 60297-3-101 (test set-up and load definitions are selected from IEC 61587-1 and IEC 61587-5). Key words: R-Type, Subracks, Plug-in unit
SIST EN 60297-3-108:2015 is classified under the following ICS (International Classification for Standards) categories: 31.240 - Mechanical structures for electronic equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
You can purchase SIST EN 60297-3-108:2015 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
The article discusses the standards and dimensions for R-type subracks and plug-in units in the field of electronic equipment. These variants are designed to be more rugged and resistant to vibrations, shocks, and electromagnetic interference. While externally compatible with the existing standard, they are mostly incompatible internally. The R-type subracks and plug-in units follow dimensions and features that provide a higher level of ruggedness compared to the previous standard. This is achieved through the selection of test set-up and load definitions from relevant standards.
記事のタイトル:SIST EN 60297-3-108:2015 - 電子機器のための機械構造 - 482.6 mm(19インチ)シリーズの機械構造の寸法--Part 108:Rタイプのサブラックとプラグインユニットの寸法 記事の内容:このIEC 60297の一部では、より過酷な環境で使用するために、優れた振動および衝撃耐性や改良されたEMC性能を備えた、482.6 mm(19インチ)シリーズの機械構造のRタイプのサブラックとプラグインユニットの寸法と特徴を提供しています。これにより、IEC 60297-3-100と外部的に互換性がありますが、IEC 60297-3-101とは内部的にはほとんど互換性がありません。Rタイプのサブラック、シャーシ統合サブラック、およびプラグインユニットは、IEC 60297-3-101と比較してより頑丈なレベルを提供する寸法と特徴を取り入れています(試験設定と負荷定義はIEC 61587-1およびIEC 61587-5から選択されます)。
この記事は、SIST EN 60297-3-108という規格について説明しています。この規格は、482.6 mm(19インチ)シリーズに属するRタイプのサブラックやプラグインユニットの寸法と特徴を提供しています。これらの耐衝撃性や電磁干渉(EMC)性能が向上した頑丈なバリエーションは、より過酷な環境で使用するために適しています。IEC 60297-3-100とは外部的に互換性がありますが、IEC 60297-3-101とは大部分が内部的には互換性がありません。Rタイプのサブラック、シャーシ統合サブラック、およびプラグインユニットは、IEC 60297-3-101で指定されたものよりも頑丈に設計されており、テストの設定と負荷定義はIEC 61587-1およびIEC 61587-5から選択されます。
이 문서는 SIST EN 60297-3-108 표준에 대해 논의하고 있습니다. 이 표준은 482.6 mm (19 인치) 시리즈에 속하는 R 타입 서브랙과 플러그인 유닛의 크기와 기능을 제공합니다. 이러한 견고한 변형은 향상된 진동 및 충격 저항성과 향상된 EMC(전자기적 상호작용) 성능을 갖추고 있어 더욱 힘든 환경에서 사용하기에 적합합니다. 이 표준은 IEC 60297-3-100과 외부적으로 호환되지만, IEC 60297-3-101과 대부분 내부적으로 호환되지 않습니다. R 타입 서브랙, 샤시 통합 서브랙 및 플러그인 유닛은 IEC 60297-3-101에서 지정된 것보다 더 견고하게 설계되었으며, 테스트 설정 및 부하 정의는 IEC 61587-1 및 IEC 61587-5에서 선택됩니다.
제목: SIST EN 60297-3-108:2015 - 전자 장비용 기계 구조물 - 482.6mm (19인치) 시리즈 기계 구조물의 차원 -- Part 108: R 유형 서브랙과 플러그인 유닛의 차원 내용: 이 IEC 60297의 일부는 강화된 진동 및 충격 저항성 및/또는 개선된 EMC 성능을 갖춘, 보다 가혹한 환경에서 사용하기 위한 482.6mm (19인치) 시리즈의 기계 구조물의 R 유형 서브랙과 플러그인 유닛의 차원과 기능을 제공합니다. 이는 IEC 60297-3-100과 외부적으로 호환되지만 IEC 60297-3-101과 대부분은 내부적으로 호환되지 않는 서브랙 표준을 가져옵니다. R 유형 서브랙, 샤시 통합 서브랙 및 플러그인 유닛은 IEC 60297-3-101에 비해 보다 견고한 수준을 제공하기 위해 차원과 기능을 포함합니다 (시험 설정 및 하중 정의는 IEC 61587-1 및 IEC 61587-5에서 선택됩니다).
The article discusses a standard, SIST EN 60297-3-108, which provides dimensions and features for R-type subracks and plug-in units that are part of the 482.6 mm (19 in) series. These ruggedized variants have enhanced vibration and shock resistance and improved electromagnetic compatibility (EMC) performance, making them suitable for use in more challenging environments. While externally compatible with the IEC 60297-3-100 standard, they are largely internally incompatible with the IEC 60297-3-101 standard. The R-type subracks, chassis integrated subracks, and plug-in units are designed to be more resilient than those specified in IEC 60297-3-101, with their test set-up and load definitions selected from IEC 61587-1 and IEC 61587-5.








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...