Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 4: Guidance for the assessment of conformity

This CEN Technical Specification gives guidance for the assessment of conformity to be included in the manufacturer's quality plan as part of the quality system.
This Technical Specification includes:
a)   requirements for materials, components and joints given in EN 13476-1, EN 13476-2 and EN 13476-3;
b)   requirements for the manufacturer's quality;
NOTE 1   It is recommended that the quality system conforms to EN ISO 9001:2000 [1].
c)   definitions and procedures to be applied if third party certification is involved.
NOTE 2   If third party certification is involved, it is recommended that the certification body is accredited to EN 45011 [2] or EN 45012 [3], as applicable.
This standard is applicable to:
a)   structured-wall pipes and fittings, which are intended to be used buried in ground outside the building structure only; reflected in the marking of products by “U”;
b)   structured-wall pipes and fittings, which are intended to be used buried in ground both outside (application area code “U”) and within the building structure (application area code “D”); reflected in the marking of products by “UD”.
In conjunction with EN 13476-2 and EN 13476-3 it is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints.

Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Rohrleitungssysteme mit profilierter Wandung aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) - Teil 4: Empfehlungen für die Beurteilung der Konformität

Diese Technische Spezifikation von CEN gibt Empfehlungen für die Beurteilung der Konformität, die im
Qualitätssicherungsplan des Herstellers als Teil des Qualitätssicherungssystems enthalten sein müssen.
Diese Technische Spezifikation enthält:
a) Anforderungen an Werkstoffe, Rohrleitungsteile und Verbindungen, die in EN 13476-1, EN 13476-2 und
EN 13476-3 festgelegt sind;
b) Anforderungen an die Qualität des Herstellers;
ANMERKUNG 1 Das Qualitätssicherungssystem sollte EN ISO 9001:2000 [1] entsprechen.
c) Definitionen und durchzuführende Verfahren bei Drittstellenzertifizierung.
ANMERKUNG 2 Bei Drittstellenzertifizierung wird empfohlen, diese durch eine, in Abhängigkeit der Anwendung nach
EN 45011 [2] bzw. EN 45012 [3] zugelassene Zertifizierungsstelle durchführen zu lassen.
Diese Norm gilt für:
d) Rohre und Formstücke mit profilierter Wandung, die ausschließlich für erdverlegte Anwendungen
außerhalb der Gebäudestruktur vorgesehen sind; auf dem Erzeugnis gekennzeichnet durch
Anwendungskennzeichen „U“;
e) Rohre und Formstücke mit profilierter Wandung, die für erdverlegte Anwendungen sowohl außerhalb
(Anwendungskennzeichen „U“) als auch innerhalb (Anwendungskennzeichen „D“) der Gebäudestruktur
vorgesehen sind; auf dem Erzeugnis gekennzeichnet durch „UD“.
In Verbindung mit EN 13476-2 und EN 13476-3 gilt sie für Rohre und Formstücke mit profilierter Wandung mit
oder ohne angeformte Muffe mit elastomeren Dichtringverbindungen sowie mit Heizelement-Stumpf-,
Extrusions- und Heizwendelschweißverbindungen.

Systemes de canalisations en plastique pour les branchements et les collecteurs d'assainissement sans pression enterrés - Systemes de canalisations a parois structurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylene (PP) et polyéthylene (PE) - Partie 4 : Guide pour l'évaluation de la conformité

La présente Spécification technique CEN donne des indications pour l'évaluation de la conformité à inclure
dans le plan qualité du fabricant, dans le cadre du système qualité.
La présente Spécification technique comprend :
a) les exigences relatives aux matières, composants, joints et assemblages données dans l'EN 13476-1,
l'EN 13476-2 et l'EN 13476-3 ;
b) les exigences relatives au système qualité du fabricant ;
NOTE 1 Il est recommandé que le système qualité soit conforme à l'EN ISO 9001:2000 [1].
c) les définitions et les procédures à appliquer en cas de certification par tierce partie.
NOTE 2 En cas de certification par tierce partie, il est recommandé que l'organisme de certification soit accrédité selon
l'EN 45011 [2] ou l'EN 45012 [3], selon le cas.
La présente norme s'applique aux :
d) tubes et raccords à parois structurées, destinés à être utilisés enterrés uniquement à l'extérieur du
bâtiment ; ceci se retrouve dans le marquage « U » des produits ;
e) tubes et raccords à parois structurées destinés à être utilisés enterrés, aussi bien à l'extérieur de la
structure du bâtiment (code de zone d'application « U ») qu'à l'intérieur de la structure du bâtiment (code de
zone d'application « D ») ; ceci se retrouve dans le marquage « UD » des produits ;
Conjointement à l'EN 13476-2 et à l'EN 13476-3, elle est applicable aux tubes et raccords à parois structurées
qui comprennent des assemblages avec ou sans emboîture intégrée à bague d'étanchéité en élastomère
ainsi que des assemblages soudés et des assemblages obtenus par fusion.

Cevni sistemi iz polimernih materialov za odvodnjavanje in kanalizacijo, ki delujejo po težnostnem principu in so položeni v zemljo - Cevni sistemi s strukturirano steno iz nemehčanega polivinilklorida (PVC-U), polipropilena (PP) in polietilena (PE) - 4. del: Navodilo za ugotavljanje skladnosti

General Information

Status
Withdrawn
Publication Date
02-Dec-2008
Withdrawal Date
13-Jun-2013
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
13-Jun-2013
Due Date
06-Jul-2013
Completion Date
14-Jun-2013

Relations

Buy Standard

Technical specification
TS CEN/TS 13476-4:2009
English language
23 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST-TS CEN/TS 13476-4:2009
01-januar-2009
&HYQLVLVWHPLL]SROLPHUQLKPDWHULDORY]DRGYRGQMDYDQMHLQNDQDOL]DFLMRNL
GHOXMHMRSRWHåQRVWQHPSULQFLSXLQVRSRORåHQLY]HPOMR&HYQLVLVWHPLV
VWUXNWXULUDQRVWHQRL]QHPHKþDQHJDSROLYLQLONORULGD 39&8 SROLSURSLOHQD 33 LQ
SROLHWLOHQD 3( GHO1DYRGLOR]DXJRWDYOMDQMHVNODGQRVWL
Plastics piping systems for non-pressure underground drainage and sewerage -
Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U),
polypropylene (PP) and polyethylene (PE) - Part 4: Guidance for the assessment of
conformity
Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -
leitungen - Rohrleitungssysteme mit profilierter Wandung aus weichmacherfreiem
Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) - Teil 4:
Empfehlungen für die Beurteilung der Konformität
Systemes de canalisations en plastique pour les branchements et les collecteurs
d'assainissement sans pression enterrés - Systemes de canalisations a parois
structurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylene (PP) et
polyéthylene (PE) - Partie 4 : Guide pour l'évaluation de la conformité
Ta slovenski standard je istoveten z: CEN/TS 13476-4:2008
ICS:
23.040.20 Cevi iz polimernih materialov Plastics pipes
91.140.80 Drenažni sistemi Drainage systems
93.030 Zunanji sistemi za odpadno External sewage systems
vodo
SIST-TS CEN/TS 13476-4:2009 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST-TS CEN/TS 13476-4:2009

---------------------- Page: 2 ----------------------

SIST-TS CEN/TS 13476-4:2009
TECHNICAL SPECIFICATION
CEN/TS 13476-4
SPÉCIFICATION TECHNIQUE
TECHNISCHE SPEZIFIKATION
July 2008
ICS 93.030

English Version
Plastics piping systems for non-pressure underground drainage
and sewerage - Structured-wall piping systems of unplasticized
poly(vinyl chloride) (PVC-U), polypropylene (PP) and
polyethylene (PE) - Part 4: Guidance for the assessment of
conformity
Systèmes de canalisations en plastique pour les Kunststoff-Rohrleitungssysteme für erdverlegte drucklose
branchements et les collecteurs d'assainissement sans Abwasserkanäle und -leitungen - Rohrleitungssysteme mit
pression enterrés - Systèmes de canalisations à parois profilierter Wandung aus weichmacherfreiem
structurées en poly(chlorure de vinyle) non plastifié (PVC- Polyvinylchlorid (PVC-U), Polypropylen (PP) und
U), polypropylène (PP) et polyéthylène (PE) - Partie 4 : Polyethylen (PE) - Teil 4: Empfehlungen für die Beurteilung
Guide pour l'évaluation de la conformité der Konformität
This Technical Specification (CEN/TS) was approved by CEN on 20 October 2007 for provisional application.
The period of validity of this CEN/TS is limited initially to three years. After two years the members of CEN will be requested to submit their
comments, particularly on the question whether the CEN/TS can be converted into a European Standard.
CEN members are required to announce the existence of this CEN/TS in the same way as for an EN and to make the CEN/TS available
promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force (in parallel to the CEN/TS)
until the final decision about the possible conversion of the CEN/TS into an EN is reached.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2008 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TS 13476-4:2008: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
Contents Page

Foreword. 3
Introduction . 4
1 Scope. 5
2 Normative references . 5
3 Terms, definitions and abbreviations . 5
3.1 Terms and Definitions . 6
3.2 Abbreviations . 7
4 Requirements . 8
4.1 General . 8
4.2 Testing and inspection . 8
4.2.1 Material specifications. 8
4.2.2 Grouping, for the purposes of this standard the following groups shall apply. . 11
4.2.3 Type tests (TT). 12
4.2.4 Batch release tests (BRT). 15
4.2.5 Process verification tests (PVT). 18
4.2.6 Audit tests (AT) . 19
4.2.7 Indirect tests (IT) . 21
4.2.8 Inspection records and test records. 21
Annex A (informative) Survey of test regime. 22
Bibliography . 23

2

---------------------- Page: 4 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
Foreword
This document (CEN/TS 13476-4:2008) has been prepared by Technical Committee CEN/TC 155 “Plastics
piping systems and ducting systems”, the secretariat of which is held by NEN.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This standard is a part of a System Standard for plastics piping systems of particular materials for specified
applications. There are a number of such System Standards.
System Standards are based on the results of the work being undertaken in ISO/TC 138 “Plastics pipes,
fittings and valves for the transport of fluids”, which is a Technical Committee of the International Organization
for Standardization (ISO).
They are supported by separate standards on test methods to which references are made throughout the
System Standard.
The System Standards are consistent with general standards on functional requirements and on
recommended practice for installation.
EN 13476 consists of the following Parts under the general title Plastics piping systems for non-pressure
underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride)
(PVC-U), polypropylene (PP) and polyethylene (PE):
 Part 1: General requirements and performance characteristics;
 Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system,
Type A;
 Part 3: Specifications for pipes and fittings with smooth internal and profiled external surface and the
system, Type B;
 Part 4: Guidance for the assessment of conformity (this Technical Specification);
1)
 Part 5: Guidance for installation (CEN/TS). .
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to announce this Technical Specification: Austria, Belgium, Bulgaria, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.


1
The feasibility of this project is under study.
3

---------------------- Page: 5 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
Introduction
This Technical Specification gives guidance for the assessment of conformity. It is intended to serve as a
guide for the assessment of conformity of products covered by EN 13476-1, EN 13476-2 and EN 13476-3.
It can be used integrally and/or be used for inclusion of conformity assessment in the manufacturer's quality
plan as part of the quality system for attestation purposes. The use of this Technical Specification does not
presume the involvement of a third party.
It can also be used to support the elaboration of national third party certification procedures for products
conforming to EN 13476-1, EN 13476-2 and EN 13476-3. It is the responsibility of the manufacturer to choose,
or not to choose for the involvement of a third party for certification purposes.
4

---------------------- Page: 6 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
1 Scope
This CEN Technical Specification gives guidance for the assessment of conformity to be included in the
manufacturer's quality plan as part of the quality system.
This Technical Specification includes:
a) requirements for materials, components and joints given in EN 13476-1, EN 13476-2 and EN 13476-3;
b) requirements for the manufacturer's quality;
NOTE 1 It is recommended that the quality system conforms to EN ISO 9001:2000 [1].
c) definitions and procedures to be applied if third party certification is involved.
NOTE 2 If third party certification is involved, it is recommended that the certification body is accredited to EN 45011 [2]
or EN 45012 [3], as applicable.
This standard is applicable to:
d) structured-wall pipes and fittings, which are intended to be used buried in ground outside the building
structure only; reflected in the marking of products by “U”;
e) structured-wall pipes and fittings, which are intended to be used buried in ground both outside
(application area code “U”) and within the building structure (application area code “D”); reflected in the
marking of products by “UD”.
In conjunction with EN 13476-2 and EN 13476-3 it is applicable to structured-wall pipes and fittings with or
without an integral socket with elastomeric ring seal joints as well as welded and fused joints.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 13476-1:2007, Plastics piping systems for non-pressure underground drainage and sewerage ―
Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and
polyethylene (PE) ― Part 1: General requirements and performance characteristics
EN 13476-2:2007, Plastics piping systems for non-pressure underground drainage and sewerage ―
Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and
polyethylene (PE) ― Part 2: Specifications for pipes and fittings with smooth internal and external surface and
the system, Type A
EN 13476-3:2007, Plastics piping systems for non-pressure underground drainage and sewerage ―
Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and
polyethylene (PE) ― Part 3: Specifications for pipes and fittings with smooth internal and profiled external
surface and the system, Type B
3 Terms, definitions and abbreviations
For the purposes of this standard, the following definitions, symbols and abbreviations given in
EN 13476-1:2007, EN 13476-2:2007 and EN 13476-3:2007 together with the following apply.
5

---------------------- Page: 7 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
3.1 Terms and Definitions
3.1.1
certification body
impartial body, governmental or non-governmental, possessing the necessary competence and responsibility
to carry out certification of conformity according to given rules of procedure and management
3.1.2
inspection body
impartial organization or company, approved by a certification body as possessing the necessary competence
to verify and/or to carry out initial type testing, audit testing and inspection of the manufacturer's factory
production control in accordance with the relevant European Standard
3.1.3
testing laboratory
laboratory that measures, tests, calibrates or otherwise determines the characteristics of the performance of
materials and products
3.1.4
quality system
organisational structure, responsibilities, procedures, processes and resources for implementing quality
management (see EN ISO 8402:1995 [4])
3.1.5
quality plan
document setting out the specific quality practices, resources and sequence of activities relevant to a
particular product or range of products
3.1.6
type testing (TT)
3.1.6.1
general type testing (TT)
tests performed to prove that the material, component, joint or assembly is capable of conforming to the
requirements given in the relevant standard
3.1.6.2
preliminary type testing (PTT)
type testing carried out by or on behalf of the manufacturer
3.1.6.3
initial type testing (ITT)
type testing carried out by or on behalf of a certification body for certification purposes
3.1.6.4
batch release test (BRT)
test performed by the manufacturer on a batch of components, which has to be satisfactorily completed before
the batch can be released
3.1.7
process verification test (PVT)
test performed by the manufacturer on compounds, components, joints or assemblies at specific intervals to
confirm that the process continues to be capable of producing components conforming to the requirements
given in the relevant standard
6

---------------------- Page: 8 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
NOTE Such tests are not required to release batches of components and are carried out as a measure of process
control.
3.1.8
audit test (AT)
test performed by or on behalf of a certification body to confirm that the compound, component, joint or
assembly continues to conform with the requirements given in the relevant standard and to provide
information to assess the effectiveness of the quality system
3.1.9
indirect test (IT)
test performed by the manufacturer different from that specified for that particular characteristic, having
verified its correlation with the specified test
3.1.10
witness testing (WT)
testing accepted by the certification body for initial type testing and/or audit testing which is carried out by or
on behalf of the manufacturer and supervised by a representative of the certification body, qualified in testing
3.1.11
material
defined type of polymer or additive or constituent thereof
3.1.12
compound (blend)
recipe which defines types of polymer, additives and constituents at specified dosage levels
3.1.13
material batch or compound batch
clearly identifiable quantity of a particular material or compound
3.1.14
production batch
clearly identifiable collection of units, manufactured consecutively under the same conditions, using material
or compounds conforming to the same specification
3.1.15
lot
clearly identifiable sub-division of a batch for inspection purposes
3.1.16
sample
one or more units of product drawn from a batch or lot, selected at random without regard to quality
NOTE The number of units of product in the sample is the sample size.
3.1.17
group
collection of similar components from which samples are selected for testing purposes
3.2 Abbreviations
NOTE To avoid any misunderstanding the following abbreviations are kept the same for each language. For the
same reason, the terms are given in the three languages (“en” for English, “fr” for French and “de” for German).
7

---------------------- Page: 9 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
AT en : audit test
fr : essai d'audit
de : Überwachungsprüfung
BRT en : batch release test
fr : essai de libération de campagne de fabrication
de : Freigabeprüfung einer Charge
IT en : indirect test
fr : essai indirect
de : indirekte Prüfung
ITT en : initial type testing
fr : essais de type initiaux
de : Erst-Typprüfung
PTT en : preliminary type testing
fr : essais de type preliminaries
de : vorausgehende Typprüfung
PVT en : process verification test
fr : essai de vérification du procédé de fabrication
de : Prüfung zur Prozessüberwachung
TT en : type test
fr : essai de type
de : Typprüfung
WT en : witness testing
fr : essais de témoins
de : Prüfung unter Aufsicht
4 Requirements
4.1 General
4.1.1 Materials, components, joints and assemblies shall conform to the requirements given in EN 13476-1,
EN 13476-2 and EN 13476-3, as applicable.
4.1.2 Components and/or assemblies shall be produced by the manufacturer under a quality system that
includes a quality plan.
4.2 Testing and inspection
4.2.1 Material specifications
NOTE In the following clauses it is defined when a modification of a compound is to be considered as a change of
compound.
4.2.1.1 Compound specification PVC
For the purposes of this standard the compound specification consists of a recipe/compound that defines
types of PVC and additives and their dosage levels.
8

---------------------- Page: 10 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
The dosage level of ingredients of a compound shall not exceed the tolerance bands given in Table 1. If any
level exceeds the dosage band or if a type is changed, this variation in formulation constitutes a change in
compound.
The use of reprocessable and/or recyclable material with agreed specification shall be considered as a
change in compound when the change in addition exceeds the tolerance bands given in Table 2.
The values of the parts X to be added to 100 parts of PVC resin shall be specified by the manufacturer in their
quality plan.
Table 1 ― Material specification PVC compound
Ingredients Type Band
+3
PVC resin Nominal K value: as specified units
0
Type and content of stabiliser or 1) Pb X : ± 25 %
1
masterbatch 2) Ca-Zn
3) Sn
4) Ca-Sn
5) others
Lubricants All X : ± 50 % for X < 0,2
2 2
X : ± 0,1 parts for X > 0,2
2 2
0
Mineral modifiers 1) CaC0 X : parts
3 3 −6
0
2) others X : %
4,1 −50
0
X : %
4,n −50
Impact modifiers All X : ± 1 part
5
Flow agents All X : ± 25 % for X < 2
6 6
X : ± 0,5 parts for X > 2
6 6
Pigments No requirement
Others To be separately specified by the X : ± 12,5 %
7,1
manufacturer
X : ± 12,5 %
7,n

Table 2 ― Specification of PVC reprocessable and recycling material
Ingredients Type Band
0
b
External reprocessable and With or without an agreed X :
8
−X
8
recyclable material from pipes and specification
See limitations in B.2.1 of
fittings
a
External and internal layers
EN 13476-2:2007 and /or
EN 13476-3:2007.
0
a b
External reprocessable and With an agreed specification X :
9 −X
9
recyclable material
a
 The specification shall be declared by the manufacturer to the certification body.
b
 Provided the tolerances of Table 1 are still met.

9

---------------------- Page: 11 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
4.2.1.2 Material specification PP
For the purposes of this document the compound specification consists of a recipe/compound having a
polypropylene with specific product name and grade and additives with known dosage level.
When the masterbatch is used it shall be considered a change of compound when modifications exceed the
tolerance bands given in Table 3.
The use of reprocessable and/or recyclable material with the agreed specification shall be considered as a
change in compound when the change in addition exceeds the tolerance bands given in Table 4.
Table 3 ― Compound specification PP masterbatch
Ingredients Type Band
Stabiliser Per individual type X : ± 25 %
1
0
Mineral modifiers Per individual type X :
2,1
−X
2,1
0
X :
2,n
−X
2,n
Pigments No requirement

Table 4 ― Specification of PP reprocessable and recycling material
Ingredients Type Band
0
a b
External reprocessable and With an agreed specification  X :
3 −X
3
recyclable material
External and internal layers See limitations in D.2.1 of
EN 13476-2:2007 and/or
EN 13476-3:2007.
0
a b
External reprocessable and With an agreed specification  X :
4
−X
4
recyclable material
Specified intermediate layers See limitations in D.2.2 of
EN 13476-2:2007 and/or
EN 13476-3:2007.
a
The specification shall be declared by the manufacturer to the certification body.
b
Provided the tolerances of Table 3 are still met.

4.2.1.3 Compound specification PE
For the purposes of this standard the compound specification consists of a recipe/compound having a
polyethylene with specific product name and grade and additives with known dosage level.
When masterbatch is used it shall be considered a change of compound when modifications exceed the
tolerance bands given in Table 5.
The use of reprocessable and/or recyclable material with the agreed specification shall be considered as a
change in compound when the change in addition exceeds the tolerance bands given in Table 6.
10

---------------------- Page: 12 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
Table 5 ― Compound specification PE masterbatch
Ingredients Type Band
Stabiliser Per individual type X : ± 25 %
1
0
Mineral modifiers Per individual type X :
2,1
−X
2,1
0
X :
2,n
−X
2,n
Pigments No requirement

Table 6 ― Specification of PE reprocessable and recycling material
Ingredients Type Band
0
a b
External reprocessable and With an agreed specification  X :
3 −X
3
recyclable material
External and internal layers See limitations in F.2.1 of
EN 13476-2:2007 and/or
EN 13476-3:2007.
0
a b
External reprocessable and With an agreed specification  X :
4
−X
4
recyclable material
Specified intermediate layers See limitations in F.2.2 of
EN 13476-2:2007 and/or
EN 13476-3:2007.
a
 The specification shall be declared by the manufacturer to the certification body.
b
 Provided the tolerances of Table 5 are still met.

4.2.2 Grouping, for the purposes of this standard the following groups shall apply.
4.2.2.1 Size group
A group of nominal sizes DN. Three size groups are defined as given in Table 7.
Table 7 ― Definition of size groups
Size group number DN/OD or DN/ID
1 ≤ 200
2 > 200 and ≤ 500
3 > 500 and ≤ 1 200

4.2.2.2 Fitting group
A group of fitting types having a similar design. Three fitting groups are defined as follows:
 Fitting group 1: Bends;
 Fitting group 2: Branches;
 Fitting group 3: Other fittings.
Push-fit fittings and fusion fittings shall be considered separately for each group.
11

---------------------- Page: 13 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
4.2.3 Type tests (TT)
4.2.3.1 General
Type tests shall demonstrate that products conform to all requirements for the characteristics given in Table 8,
Table 9 and Table 10 as applicable.
Type test shall be carried out on products manufactured using virgin material and in case reprocessable
and/or recyclable material according to Table 2, Table 4 or Table 6 is also intended to be used on products
manufactured using the maximum amount of reprocessable or recyclable material, which is intended to be
used unless the addition is in accordance with B.3, D.3 or F.3 of EN 13476-2:2007 and/or EN 13476-3:2007,
as applicable. In addition, relevant type tests shall be carried out whenever there is a change in design, in
compound including use of reprocessable or recyclable material, see, Table 8, Table 9 or Table 10 and/or in
the production method, other than routine in-process adjustments and to extensions of the product range as
indicated in the same tables.
In the case of change of compound or extended use of reprocessable or recyclable material the type testing
(TT) can be carried out by the manufacturer on the characteristics specified for such occasions in column M of
Table 8, Table 9 or and Table 10, as applicable. An audit test shall be made within 6 months to verify the
result of the TT.
12

---------------------- Page: 14 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
Table 8 ― Characteristics of pipes that require type testing
Reference to clauses and Sampling procedure (minimum
a
Testing relevant to
tables of sampling)
Characteristic
EN 13476-2 EN 13476-3 N D M P E Generally per design family
one calculation or
PVC content 4.2.1 4.2.1 + − + − −
determination/compound
one calculation or
PP content 4.3.1 4.3.1 + − + − −
determination/compound
one calculation or
PE content 4.4.1 4.4.1 + − + − −
determination/compound
Melt mass-flow rate
Table 2 or 3 Table 2 or 3 + − + − − one sample/compound
(MFR-value)
Resistance to internal
Table 1, 2 or 3 Table 1, 2 or 3 + − + − − one sample/compound
b
pressure
c
Thermal stability (OIT) Table 2 or 3 Table 2 or 3 + − + − − one sample/compound
Density Table 3 Table 3 + − + − − one sample/compound
Appearance 6 6 + + + + + one sample/size group
Colour 6 6 + − + − + one sample/size group
7.2; Tables 5, 6, 7 7.2; Tables 5, 6,
Dimensions + + − + + one sample/size/stiffness class
and 8 and 7
Vicat softening
Table 9 Table 8 + − + − − one sample/compound
temperature
Resistance to
Table 9 Table 8 + − + − + one sample/size group/compound
dichloromethane
Longitudinal reversion
Table 9, 11 or 13 NA + + + + + one sample/size group

Type A1 and A2 pipes
Oven test, Type B pipes NA Table 8, 10 or 12 + + + + + one sample/size group
Impact resistance Table 15 or Table 14 or
(round the clock Annex G as Annex G as + + + + + one sample/size group/compound
method) applicable applicable
Impact strength Annex H if Annex H if
+ + + + + one sample/size group/compound
d
(staircase method) applicable applicable
one sample/size group/SN class
Ring stiffness Table 15 Table 14 + + + + +
and for each compound
Table 15 or Table 14 or
one sample/size group/SN class
Ring flexibility
Annex I as Annex I as + + + + +
and for each compound
applicable applicable
e
Creep ratio Table 15 Table 14 + + + + + /design family /compound
Tensile strength of
Table 15 Table 14 + + + + + /size/compound
seam
Marking Table 19 Table 18 + − − − + one sample/size group
a
N: new system
D: change of design (only for characteristics affected by the change)
M: change of compound
P: change of production method (only for characteristics affected by the change)
E: extension of the product range (except the products already covered by the minimum sampling procedure)
b
To be tested in pipe form with an optional diameter.
c
Only applicable for components for fused joints.
d
Only for pipes intended also to be installed at temperature below -10 °C. If this test is required, then the round-the-clock method is not
necessary.
e
By design family is understood designs with the same ratio between the neutral diameter of the pipe wall and the max. distance to the
outer or inner profile.

13

---------------------- Page: 15 ----------------------

SIST-TS CEN/TS 13476-4:2009
CEN/TS 13476-4:2008 (E)
Table 9 ― Characteristics of fittings that require type testing
Reference to clauses and Sampling procedure (minimum
a
Testing relevant to
tables of sampling)
Characteristic
Generally per design family
EN 13476-2 EN 13476-3 N D M P E
one calculation or
PVC content 4.2.1 4.2.1 + − + − −
determination/compound
one calculation or
PP content 4.3.1 4.3.1 + − + − −
determination/compound
one calculation or
PE content 4.4.1 4.4.1 + − + − −
determination/compound
Melt mass-flow rate
Table 2, 3 or Table 2, 3 or
+ − + − − one sample/compound
b
4 4
(MFR-value)
Resistance to internal Table 1, 2, 3 Table 1, 2, 3
+ − + − − one sample/
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.