Non-destructive testing - Lighting in penetrant and magnetic particle testing, good practice

This Technical Report describes the good practices of lighting under UV-A radiation and in white light as used for penetrant testing (PT) and magnetic particle testing (MT) for improved probability of detection (POD).
This informative document deals with the irradiance and the illuminance used in PT and MT. It is intended for:
-   manufacturers, who are encouraged to supply the criteria and the restrictions on use of their products, as well as detailed characteristics for the appropriate choice and the optimum use of sources available on the market;
-   users, to enable them to make the best use of lighting sources for efficient inspection in working conditions;
-   supervision and training personnel, who may design and optimally arrange inspection areas, recommend the principles of visual ergonomics for ensuring inspector efficiency, comfort and safety.

Zerstörungsfreie Prüfung - Beleuchtung in Eindring- und Magnetpulverprüfung , bewährte Verfahren

Essais non destructifs - Bonnes pratiques d’éclairage lors des contrôles par ressuage et par magnétoscopie

Le présent rapport technique décrit les bonnes pratiques d’éclairage sous rayonnement UV-A et en lumière blanche utilisé en ressuage et magnétoscopie pour améliorer la probabilité de détection (POD).
Ce document à caractère informatif traite des éclairements énergétiques et lumineux utilisés en ressuage et magnétoscopie. Il est destiné à l’attention :
   des fabricants, qui doivent être incités à fournir les critères et les limites d’utilisation de leurs produits ainsi que les caractéristiques détaillées en vue du choix approprié et de l’utilisation optimale des sources disponibles sur le marché ;
   des utilisateurs, afin qu’ils puissent tirer le meilleur parti des sources d’éclairage pour des examens efficaces dans les conditions de travail ;
   du personnel d’encadrement et de formation, qui peut agencer et ordonnancer de façon optimale les zones d'examen, recommander les principes d’ergonomie visuelle assurant efficacité, confort et sécurité aux contrôleurs.

Neporušitvene preiskave - Osvetlitev pri preiskavah s penetranti in magnetnimi delci, dobra praksa

To tehnično poročilo opisuje dobre prakse osvetlitve pri sevanju UV-A in beli svetlobi, ki se uporablja pri preiskavah s penetranti in magnetnimi delci. Ta informativni dokument obravnava sevanje in osvetlitve, ki se uporabljajo pri preiskavah s penetranti in magnetnimi delci. Namenjen je:    – proizvajalcem, da predložijo kriterije in omejitve za uporabo svojih izdelkov ter podrobne značilnosti za ustrezno izbiro in optimalno uporabo virov, ki so na voljo na trgu,    – uporabnikom da bi najboljše izkoristili vire UV-A za učinkovit nadzor in v najboljših pogojih uporabe,    – centrom za nadzor in usposabljanje, ki lahko zavestno oblikujejo in optimalno uredijo področja nadzora ter priporočajo načela vizualne ergonomije za zagotovitev učinkovitosti, udobja in varnosti inšpektorjev.

General Information

Status
Published
Publication Date
22-Oct-2017
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
11-Jul-2017
Due Date
15-Sep-2017
Completion Date
23-Oct-2017

Overview

CEN/TR 17108:2017 - "Non‑destructive testing - Lighting in penetrant and magnetic particle testing, good practice" provides guidance on lighting best practices for penetrant testing (PT) and magnetic particle testing (MT). The Technical Report focuses on the use of UV‑A radiation and white light, addressing irradiance and illuminance criteria to improve the probability of detection (POD) during visual NDT inspections. It is intended for manufacturers, inspection personnel, supervisors and trainers involved in NDT lighting selection, layout and safety.

Key Topics

  • UV‑A spectral characteristics
    • Importance of centroid wavelength near the absorbance peak of fluorescent dyes (around 360–370 nm) for efficient excitation.
    • Need to minimize unwanted visible violet emission (380–420 nm) that reduces contrast and increases visual noise.
    • Recommendation to specify a UV‑A/violet ratio in product documentation.
  • Filters and optics
    • Use of Wood filters or equivalent to reduce violet leakage and preserve inspection contrast.
  • Thermal management and stability
    • Cooling and temperature control for LED sources to avoid spectrum drift, power loss or increased violet output.
    • Design guidance for preventing unacceptable irradiance decrease during use.
  • Beam geometry and lighting patterns
    • Matching beam size, shape and edge profile to part size and inspection layout (large parts, clusters, trays).
    • Consideration of foveal and peripheral vision to maximize detection capability.
  • Visual ergonomics and workplace lighting
    • Recommendations on visible light levels before, during and after inspection to reduce visual fatigue and improve inspector performance.
    • Guidance for fixed inspection booths and on‑site inspections.
  • Measurements and instruments
    • Use and specification of radiometers and luxmeters for measuring irradiance and illuminance.
  • Health & safety
    • Eye protection, warning signage and precautions when using UV‑A sources; references to photobiological safety standards.

Applications and Who Uses This Standard

  • NDT technicians and inspectors - optimize inspection lighting for better defect detection in PT and MT.
  • Lighting and NDT equipment manufacturers - supply product data (spectral output, UV‑A/violet ratio, operating limits) and design robust thermal and filtering systems.
  • Quality managers and trainers - design inspection booths, set lighting procedures and train staff on visual ergonomics, safety and measurement methods.
  • Safety officers - implement protective measures in line with photobiological safety guidance.

Related Standards

CEN/TR 17108:2017 references and complements standards such as:

  • EN 170 (UV filters for eye protection)
  • EN 62471 (photobiological safety of lamps)
  • EN 12464‑1 (lighting of workplaces)
  • CEN/TR 16638 (PT and MT using blue light)
  • EN ISO 12706 / 12707 (PT and MT vocabularies)
  • ISO/CIE 19476 (illuminance/luminance meter characterization)

Keywords: CEN/TR 17108:2017, non‑destructive testing, NDT, penetrant testing, magnetic particle testing, UV‑A lighting, inspection lighting, irradiance, illuminance, visual ergonomics, probability of detection (POD).

Technical report

SIST-TP CEN/TR 17108:2017 - BARVE

English language
27 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST-TP CEN/TR 17108:2017 is a technical report published by the Slovenian Institute for Standardization (SIST). Its full title is "Non-destructive testing - Lighting in penetrant and magnetic particle testing, good practice". This standard covers: This Technical Report describes the good practices of lighting under UV-A radiation and in white light as used for penetrant testing (PT) and magnetic particle testing (MT) for improved probability of detection (POD). This informative document deals with the irradiance and the illuminance used in PT and MT. It is intended for: - manufacturers, who are encouraged to supply the criteria and the restrictions on use of their products, as well as detailed characteristics for the appropriate choice and the optimum use of sources available on the market; - users, to enable them to make the best use of lighting sources for efficient inspection in working conditions; - supervision and training personnel, who may design and optimally arrange inspection areas, recommend the principles of visual ergonomics for ensuring inspector efficiency, comfort and safety.

This Technical Report describes the good practices of lighting under UV-A radiation and in white light as used for penetrant testing (PT) and magnetic particle testing (MT) for improved probability of detection (POD). This informative document deals with the irradiance and the illuminance used in PT and MT. It is intended for: - manufacturers, who are encouraged to supply the criteria and the restrictions on use of their products, as well as detailed characteristics for the appropriate choice and the optimum use of sources available on the market; - users, to enable them to make the best use of lighting sources for efficient inspection in working conditions; - supervision and training personnel, who may design and optimally arrange inspection areas, recommend the principles of visual ergonomics for ensuring inspector efficiency, comfort and safety.

SIST-TP CEN/TR 17108:2017 is classified under the following ICS (International Classification for Standards) categories: 19.100 - Non-destructive testing. The ICS classification helps identify the subject area and facilitates finding related standards.

You can purchase SIST-TP CEN/TR 17108:2017 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2017
Neporušitvene preiskave - Osvetlitev pri preiskavah s penetranti in magnetnimi
delci, dobra praksa
Non-destructive testing - Lighting in penetrant and magnetic particle testing, good
practice
Zerstörungsfreie Prüfung - Beleuchtung in Eindring- und Magnetpulverprüfung ,
bewährte Verfahren
(VVDLVQRQGHVWUXFWLIV%RQQHVSUDWLTXHVGpFODLUDJHORUVGHVFRQWU{OHVSDUUHVVXDJHHW
SDUPDJQpWRVFRSLH
Ta slovenski standard je istoveten z: CEN/TR 17108:2017
ICS:
19.100 Neporušitveno preskušanje Non-destructive testing
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

CEN/TR 17108
TECHNICAL REPORT
RAPPORT TECHNIQUE
June 2017
TECHNISCHER BERICHT
ICS 19.100
English Version
Non-destructive testing - Lighting in penetrant and
magnetic particle testing, good practice
Essais non destructifs - Bonnes pratiques d'éclairage Zerstörungsfreie Prüfung - Beleuchtung in Eindring-
lors des contrôles par ressuage et par magnétoscopie und Magnetpulverprüfung, bewährte Verfahren

This Technical Report was approved by CEN on 28 May 2017. It has been drawn up by the Technical Committee CEN/TC 138.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TR 17108:2017 E
worldwide for CEN national Members.

Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Fluorescent techniques, inspection booth, lights and visual ergonomics . 5
4.1 Lights: UV-A beam spectral characteristics . 5
4.1.1 General . 5
4.1.2 Symmetry of the spectrum around the centroid wavelength . 5
4.1.3 Unwanted visible light of the UV-A spectrum: limitation of the emission > 380 nm . 6
4.1.4 Radiometric specifications: UV-A/violet ratio . 6
4.1.5 Thermal management (cooling), sustaining performances . 8
4.2 UV-A beam geometrical characteristics . 9
4.2.1 General . 9
4.2.2 Geometric consideration for use . 9
4.2.3 Large parts . 10
4.2.4 Small parts . 10
4.3 Identification and repair . 11
4.4 Health and safety when using UV-A sources . 11
4.4.1 Precautions for use . 11
4.4.2 Warning panels . 11
4.4.3 Eyewear . 13
4.5 Visual ergonomics . 14
4.5.1 General . 14
4.5.2 Visual adaptation, general . 14
4.5.3 Visible light before inspection . 15
4.5.4 Visible light during inspection . 16
4.5.5 Visible light after inspection: focus recovery/preserving . 17
4.5.6 Transition zones: avoid visual tiredness . 18
4.5.7 General irradiance . 18
5 Colour and luminous contrast method . 18
5.1 White beam spectral characteristics . 18
5.2 Viewing of coloured materials: choosing the source. 19
5.3 Precautions for use . 20
5.3.1 High-luminance type LED sources . 20
5.3.2 Eyewear . 22
5.4 Illuminance levels of the inspection area and of the surrounding area: visual
ergonomics . 23
5.4.1 General . 23
5.4.2 Fixed inspection areas . 23
5.4.3 On-site inspections . 23
5.4.4 Case study . 23
6 Measurements . 25
6.1 Radiometers and luxmeters characteristics/specifications . 25
6.2 Irradiance measurement . 25
7 Actinic Blue . 26
European foreword
This document (CEN/TR 17108:2017) has been prepared by Technical Committee CEN/TC 138 “Non-
destructive testing”, the secretariat of which is held by AFNOR.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
1 Scope
This Technical Report describes the good practices of lighting under UV-A radiation and in white light
as used for penetrant testing (PT) and magnetic particle testing (MT) for improved probability of
detection (POD).
This informative document deals with the irradiance and the illuminance used in PT and MT. It is
intended for:
— manufacturers, who are encouraged to supply the criteria and the restrictions on use of their
products, as well as detailed characteristics for the appropriate choice and the optimum use of
sources available on the market;
— users, to enable them to make the best use of lighting sources for efficient inspection in working
conditions;
— supervision and training personnel, who may design and optimally arrange inspection areas,
recommend the principles of visual ergonomics for ensuring inspector efficiency, comfort and
safety.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
EN 170, Personal eye-protection — Ultraviolet filters — Transmittance requirements and recommended
use
EN 12464-1, Light and lighting — Lighting of work places — Part 1: Indoor work places
CEN/TR 16638, Non-destructive testing — Penetrant and magnetic particle testing using blue light
EN 62471, Photobiological safety of lamps and lamp systems (IEC 62471)
EN ISO 12706, Non-destructive testing — Penetrant testing — Vocabulary (ISO 12706)
EN ISO 12707, Non-destructive testing — Magnetic particle testing — Vocabulary (ISO 12707)
ISO/CIE 19476 (CIE S 023/E), Characterization of the performance of illuminance meters and luminance
meters
3 Terms and definitions
For the purpose of this document, the terms and definitions given in EN ISO 12706, EN ISO 12707 and
the following apply.
3.1
centroid wavelength
mathematically weighted mean output wavelength sharing in two equal parts the spectrum emitted by
a source
3.2
colour rendering index
CRI
degree of agreement between the colour appearance of objects illuminated by the considered source
and that of the same objects illuminated by a reference illuminant, under specified viewing conditions
3.3
colour temperature
Tcp
temperature of a planckian (or black body) radiator, the radiation of which has the same chromaticity
as a given stimulus, expressed in Kelvin (K)
3.4
LEDs
light-emitting diodes
3.5
maculopathy
impaired function of the macula which degrades colour vision and leads to a decrease of visual acuity
3.6
mesopic vision
twilight or medium vision between the photopic vision and the scotopic vision
3.7
photopic vision
daytime or high-luminance vision where only the cone optic cells are active
Note 1 to entry: In photopic vision, the 555 nm wavelength (green-yellow) is the human eyes maximum
sensitivity.
3.8
scotopic vision
night-time or in low luminance vision where only the rod optic cells are active
Note 1 to entry: In scotopic vision, the 505 nm (blue-green or turquoise.) wavelength is the human eyes maximum
sensitivity.
4 Fluorescent techniques, inspection booth, lights and visual ergonomics
4.1 Lights: UV-A beam spectral characteristics
4.1.1 General
UV-A LED lamps technology needs to be understood since they are used for lighting in NDT methods
using fluorescent materials, ISO 3059 deals with requirements but the following clauses provide
technical explanation and guidance for the use of UV-A lamps in NDT.
4.1.2 Symmetry of the spectrum around the centroid wavelength
The optical brighteners used in penetrants and some fluorescent pigments used in the MT detection
media usually absorb 80 % of the radiation energy between 340 nm and 380 nm. Therefore for UV-A
LEDs a symmetrical, Gaussian emission spectrum around the peak output wavelength is recommended.
The optical brighteners used in penetrants and some fluorescent pigments used in the MT detection
media have an absorption peak between 360 nm and 370 nm. The centroid wavelength of the UV-A
source shall be close to the peak absorption so that the radiation is more efficient to excite the dyes of
the fluorescent penetrants and the pigments of the fluorescent detection media.
These conditions are met when the centroid wavelength is close to the central wavelength (emission
peak).
4.1.3 Unwanted visible light of the UV-A spectrum: limitation of the emission > 380 nm
The eye is sensitive to wavelengths greater than 380 nm. The 380 nm to 420 nm area (violet light and
extreme violet) is emitted as a stray light by most of UV-A source.
This violet can cause, as UV-A, visual blue haze by exciting some proteins in the eye.
Vision of the direct violet and indirect blue haze effect leads to increasing the noise which impairs the
detection of indications.
Manufacturer shall minimize the emission of violet light by carefully selecting the LEDs, the filter, and
using a well-controlled thermal management system to prevent any drift leading to an increase of
unwanted violet output.
This visible violet to which the eye is sensitive is not fully filtered by Wood filters nor by all the UV-
blocking goggles; this comes at the cost of the contrast at the inspection stage on all types of metal parts
(except yellow metals that naturally absorb violet and blue).
Bright surfaces strongly reflect violet light, requiring the inspector to guide the relative position of the
parts to avoid this reflection; matt surfaces turn to a purplish colour background regardless of the
orientation of the beam.
4.1.4 Radiometric specifications: UV-A/violet ratio
Violet light is the 380 nm 420 nm area.
In order to take into account the data described in the previous clause, the manufacturer or the supplier
shall state the measurements relevant to the UV-A/ violet ratio in the product data sheet (user manual,
procedure, product manual, etc.).
The result may be given in the form of a ratio calculated by analysing the spectrum with a
spectrophotometer positioned at the beam centre, then, by discriminating the UV-A area up to 380 nm
and the violet area, 380 nm to 420 nm.
For professional purposes, UV-A sources should be used so as to minimize their effect, as follows:
— a Wood filter or similar, to remove violet as much as possible, shall be an integral part of the source.
Key
X wavelength (nm)
Y relative scale
1 green curve: UV-A spectra with Wood filter in the violet range
2 purple curve: UV-A spectra without Wood filter in the violet range
Figure 1 — Example of reduction of the violet light 380 nm to 420 nm by a source fit with a Wood
filter
Key
X wavelength (nm)
Y relative irradiance
1 central wavelength: 368,9 nm
2 centroid wavelength: 369,5 nm
3 full width half maximum: 10,9 nm
NOTE The left side in light violet colour corresponds to UV-A and the right side in dark violet colour to visible
violet
Figure 2 — Example of measured spectrum
4.1.5 Thermal management (cooling), sustaining performances
A poor thermal management will cause beam instability, spectrum shift with violet increase and power
loss.
In case of LED sources, the elements ensuring the extraction of calories shall be maintained in an
optimal operation condition (e.g. dust filter replacement, removing dust deposits on coolers, renewal of
thermal paste during LED maintenance etc.).
An automatic circuit-breaker system shall be built-in to take action in case of overheating; leading to a
non-compliance of the beam (wavelength shift beyond 370 nm and violet versus UV-A ratio increase for
LEDs).
Regarding LED sources: during their use, no decrease of power, likely to reduce the irradiance without
notice by the operator, shall ever be acceptable as a means to prevent overheating.
For UV source not intended to be used continuously the manufacturer shall state the maximum time to
be used.
4.2 UV-A beam geometrical characteristics
4.2.1 General
The variety of inspection circumstances and the variety of part sizes and localizations, such as large
individual parts or grapes of small sized parts, need our attention to choose adequate lighting scenari; a
good choice leads to visual performance enhancement and better POD.
4.2.2 Geometric consideration for use
The pattern and the beam size of the source in use should be fitted to the surface of the area inspected
on the parts and the arrangement thereof (if parts are displayed as “clusters” or as “trays” of several
parts). The way the human eye works and, particularly, the roles of the fovea and of the peripheral
vision shall be taken into account during inspection.
Therefore, several types of beam patterns should be considered: wide or narrow, with sharp or
progressive edges to adapt the beam to the spatial conditions and orientation on the inspection zone to
use the full capability of detection of the human vision.
A practical test of the source for the specific application is always helpful before choosing the beam
pattern.
The field of vision may be considered as three areas:
1) The fovea is the central area of the macula (see Figure 3). It is located on the optical axis of the eye
where only the cone optic cells are tightly present. At this level, the vision is more accurate and
more detailed than for the rest of the retina;
2) The near peripheral vision utilizes rod and cone sensors and provides a more general vision
capability. This is a much wider area of the visual field than the foveal region;
3) The far peripheral vision is the remaining angular range of vision.

Key
1 fovea / macula
2 near peripheral vision
3 far peripheral vision
Figure 3 — Illustration of the vision areas
Key
4 UV-A wide type beam with progressive edge
5 UV-A narrow type beam with sharp edges
Figure 4 — UV-A beam patterns
4.2.3 Large parts
For large parts, the peripheral vision is used to guide the central vision towards points on which
attention should be focused; a wide-pattern beam with progressive edges will then be preferred.
Figures 5a and 5b give an example of NDT application: inspection of large areas; an indication seen in
the near peripheral vision “catches the eye” and initiates the movement of the eye towards a vision by
the fovea.
a) Intermediate casing of civil aeroengine b) Aircraft structural component
Figure 5
4.2.4 Small parts
When inspecting specific areas of large parts or small parts one by one, the foveal vision prevails; the
eye is used almost exclusively for its central vision.
A medium-wide uniform beam pattern with sharp edges is the optimal configuration as the right
illumination conditions will be reached inside the beam.
Figure 6 shows an example of NDT application: thorough inspection of small to medium-sized parts,
analysis of indications.
Figure 6 — Carbide ball bearings and nut (aeronautical parts)
4.3 Identification and repair
Each series of the type of source gets a unique trade name.
Any change made to the source likely to modify the data described in this document shall require a
change in the identification of the series of source type.
The characteristics of a repaired source shall be identical to those of the series of the original type
source. Otherwise, any deviation shall be documented.
4.4 Health and safety when using UV-A sources
4.4.1 Precautions for use
The triplet UV-A/O /infrared shall be avoided as much as possible in order to limit the fluorescence
fading of the indications especially for PT. This situation occurs when the area under inspection is
irradiated by a spectrum containing UV-A and infrared radiations, and hot air-flow coming from the
source further directed towards the same area.
For discharge lamps, the cooling air-flow when existing should not be directed towards the part in the
axis of the optical beam as UV-A and infrared radiations are present.
Cumulative doses of extreme violet (near UV-A) are one of the causes for maculopathy, retinal diseases
and early cataract.
4.4.2 Warning panels
In order to warn operators against the hazards inherent to UV-radiation, warning signs are placed:
a) at the entrance of the area where UV-A radiation is emitted (pictograms and wording warning
against hazards and indicating suitable protective equipment);
b) visible in the vicinity of the UV-A source, as a reminder.
Figure 7 — Examples of warning signs: UV-blocking safety goggles shall be worn

Figure 8 — Examples of warning signs: Warning Non-ionizing UV radiation
When wearing protective equipment is mandatory, it shall be mentioned in every relevant documents.

Key
X wavelength (nm)
Y spectral efficiency
Figure 9 — Spectral weighing function Suv(λ) for UV radiation hazard according to the
IEC/EN 62641
4.4.3 Eyewear
As specified in 4.1.3, violet glare impairs the quality of detection and the operator’s comfort. Any means
to lower the visibility of violet is allowed, if this does not prevent the proper viewing of indications
(specific violet-non-reflective goggles, for instance).
The UV-A radiation shall be blocked by personal protective equipment such as goggles or eyeshade, as
described in EN 170.
Some suppliers make available violet blocking lenses, keeping the colour of the glass in class 0 -
previously class A - (no colour) or treated-in-the mass lenses. Such lenses are recommended for
spectacle wearers with correction.
For inspectors without any visual correction, simple UV-blocking polycarbonate safety glasses are
suitable for UV-A protection (preventing blue haze due to fluorescence inside the eye itself). As regards
violet-blocking goggles, only models with a specific additive to polycarbonate are satisfactory.

a) Goggles fully blocking U
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.